Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹52.1 L+₹2.3 L (4.54%)Rejected-Finance NO 422 CHURCH STREET NEW THIPPASANDRA BANGALORE 560075 | BANGALORE | BANGALORE | KARNATAKA | 560075 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹52.7 L+₹2.8 L (5.59%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹53.4 L+₹3.5 L (7.03%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹53.7 L+₹3.8 L (7.60%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
27 Sept 2021, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
RENOVATION BLDG NO P 29 OF B4 SHED AT GTRE AND WIDENING OF ROADS WITH CONNECTED WORKS AT CEMILAC UNDER GE I RD EAST BANGALORE
2021_MES_471529_1
8107
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D East Bangalore
D a (i) b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹98,000
Yes
27 Oct 2021
30 Aug 2021
29 Sept 2021
30 Aug 2021
27 Sept 2021
15 Sept 2021
31 Aug 2021 - 8 Sept 2021
Amount
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed
Material and labour for PCC, 75 mm thick, 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in sub base for floor complete all as specified and as directed.
M & L 75 mm thick plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) finished even & smooth, using extra cement, as in floors, complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), rmoving servicable tiles to store and rubbish off the premises
Removing of demolition materials to a distance exc. 5 KM, but n.exc 10.0KM and depositing out side MD land complete all as directed
M&L Vitrified ceramic tiles double charged of size 10 mm thick light shade, area of each tile exceeding 0.36 sqm and not exceeding 0.42 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed
M&L Vitrified ceramic tiles double charged of size 10 mm thick light shade, area of each tile exceeding 0.36 sqm and not exceeding 0.42 sqm, in skirting. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed plaster in cement mortar 1:4 complete all as specified and as directed
M&L industrial antistatic series 600 x 600 x 10mm tiles, mat finishing of light/dark colured shade in floors (to meet industrial safety norms) and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed Make: Johnson Endura or equavalent
M & L cement concrete in foundations, filling and mass-concrete 1:5:10, type E2 (using 40 mm graded crushed stone aggregate) complete all as specified and as directed
Material and Labour for providing the sealant (pouring grade) in the existing 10mm wide & 40mm deep groove/joint after preparation of joint as per manufacture instructions along with application of primer as per manufacture instructions. (a) Thioflex 600 shall be of M/s FOSROC/ MASTERFLEX TM 700i of BASF or equivalent in CIPY. (b) Primer 7E shall be M/s FOSROC or equivalent in BASF/CIPY. Note :- Application of Epoxy and sealant shall be carried out by authorised applicator of manufacture.
Material and Labour for 2mm thick epoxy resin based floor topping after priming the surface solvent base epoxy resin primer designed for maximum absorption and adhesion as per manufacture specification including preparation of floor by wire brushing or light grit blasting to remove laitance, dust and cleaning the same to achieve mechanical key between the floor and coating system and applying epoxy putty mixed with suitable fillers to cover the worn out areas all as specified and directed. Note :- (a) Floor topping shall be Nitoflor SL 2000 of M/s FOSROC/MASTERTOP TM 1215 PLUS of BASF or equivalent in CIPY. (b) Primer shall be Nitoprime 25 of M/s FOSROC or equivalent in BASF/CIPY. (c) Epoxy putty shall be Nitoflor FC 140/150 of M/s FOSROC or equivalent in BASF/CIPY.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M & L rendering 10 mm thick in cement mortar 1:6 finished even and smooth without using extra cement over surfaces other than fair complete all as specified and directed
M&L preparing new plastered surfaces of walls and applying two coats of oil bound distember over a coat primer over and including one coat of 2mm wall care putty and preparation with sand paper to receive primer coat complete all as specified.
M & L rendering 15 mm thick in CM 1:4 in finished even and smooth without using extra cement over surfaces other than fair complete all as specified and directed (WPC shall be measured and paid separately in appropriate item)
Supply only integral water proofing compound.
M&L for preparing old painted surfaces of walls and applying two coats of oil bound distember over a coat primer over and including one coat of 2mm wall care putty and preparation with sand paper to receive primer coat complete all as specified.
M&L applying 2 coats of Exterior emulsion weather proof paint for new/old surfaces over a coat of primer incl prepration of new surface / i removal of existing treatment on wall surfaces including cornices, plasters etc by scrapping down with wire brushes and washing down and removing existing loose finishes particles etc all as specified and directed (Make/Brand Name : Asian Paints/Apex ultima, Berger Paints/Weather coat All Guard, Jenson /Nicholson/Safe Guard).(ht Upto 8 Mtr including all necessary scaffolding)
M & L Cement concrete 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in surface channels and drains complete all as directed
Demolition of Reinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L for providing precast cover slab in 1:2:4, type B-1 (using 20 mm Graded stone aggregate) complete all as specified and as directed
M&L for MS TMT bars 6 to 8 mm mm dia and over, cut to length, bent to shape required, and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed
M&L Mild steel, 1 mm thick corrugated black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
S & F Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in near cement slurry in floors including screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed
M&L Steel rolling shutter with moter oprated (Motor taken in E/M Schdule) thickness of lath in 1.0 mm including top cover,anchring rod ,hasp and staple and one shop coat of primer erected in position including taking down old shutters as directed by Engr-in Charge complete.
Taking down Steel rooling shutters and refixing in same opening after greasing ,oiling making good smooth functionand painting one coat of synthetic enamel paint any size of shutter , complete all as specified and directed.
Taking down heavy duty specially provided MS door shutter including taking out pintel hinges/specially made hinge component and locking arrangement by welding of size not exceeding 3 sqm each complete all as specified and directed
Taking down chowkhats or frame exceeding 1.5 Sq. m but not exceeding 4 Sq. m each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified.
Taking down chowkhats or frame n.exceeding 1.5 Sq. m each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified.
S&F Anodised aluminium frame for doors window and ventilatore with one or more rebates including joining cleat forfixing etc. complete all as specified
S&F Anodised aluminium window and ventilators shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified
S&F Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified
S & F sheet glass 5.5 mm thick ordinary quality tinted in exc 0.5 Sqm in each pan with rubber beading as in doors and partion complete all as specified and as directed
S&F Prelaminated particle board 12 mm thick, exterior grade,prelaminated both side with decorative choice lamination &other side balancing white lamination,fixed with screws to timber frame work as in aluminium door and partion complete all as specified and as directed
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aparture 1.40mm and fixed with aluminium wire snaples, complete complete all as specified and as directed
S & F sheet glass mm thick ordinary quality tinted exc 0.5 Sqm in each pan 4 mm thick with rubber beading as in window complete all as specified and as directed
S & F in repairs Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed (Aluminium extruded section body) complete all as specified and as directed
S&F welded steel wire fabric n. exc 4 kg/Sqm fixed with wood or steel member complete.
Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mps as in roof covering fixed with self tapping screws as specified.(Height up to 15Mtr and above/factory type bldg/Hangar)
S&F pre-painted galvalume aluminium zinc coating GI based Plain sheet 0.50 mm thick of any colour having tensile strength of 550 Mps as in roof covering fixed with self tapping screws as specified.(Height up to 15Mtr and above/factory type bldg/Hangar)
Supply & fix Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed
Demolition of brick work or stone masonary/boulder masonary, built in cement mortar including all quions, arches, pillars etc but excluding ashar facings, dressed stone work and precast article etc and depositing of debris out side MD Land all as specified and directed.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc., to store and rubbish not exc. 50m
M&L Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and as directed
Dismantling of water tanks and removing to store 1000 ltrs.
S & F 1000 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed
Taking down steel tubing and connections 15 mm dia
Taking down steel tubing and connections 20 mm dia
Taking down steel tubing and connections 25 mm dia
S & F 25 mm GI tubes, `medium grade', galvanised, with all fitting; laid in floors and fixed in walls and ceiling etc complete all as specified and as directed
S & F 20 mm GI tubes, `medium grade', galvanised, with all fitting; laid in floors and fixed in walls and ceiling etc complete all as specified and as directed
Supply and fix tubes medium grade, galvanized, with all fittings and fixed complete to walls and ceiling or laid in floors 15 mm bore complete all as specified and as directed
S & F 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms)
S & F 25 mm gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixedn complete all as specified and as directed
S & F fancy type 20 mm bib taps, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed
Demolition RCC pipe set in cement mortar any dia of pipe
S & F 450 mm Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed
Dismantling boarding any description, fixed in any position with nails complete
Providing and fixing of false ceiling system with fine fissured edge tiles having humidity resistance(RH) of 95% NRC 0.34, light reflectance approx 84%, Thermal conductivity K=0.052- 0.057 W/MK, colour white, fire performance of class-I as per BS 476 part 6&7 in module size 600x600x16 mm thick suitable for green building application with recycled content of 38-41% with Armstrong silhoette profile exposed grid system with 15 mm white flanges incorporting a 6 mm central reveal in white/black colour. Silhoutte, main runners & cross Tees to have mitred ends & "birdsmouth" notches to provide mitred cruciform junctions. The Tee sections have a galvanizing of 170 grms per m2 & passed through 500 hrs of salt Test.The main runner spaced at 1200 mm c/c should be securely fixed to the structural soffit using Armstrong suspension system at 1200 mm maximum c/c. The first/last Armstrong suspension system at the end of each main runner should not be greater than 450 mm from adjacent wall (Make :Armstrong/Saint Gobain or equavalent).
Dismantling of structural steel work including doors,gate framed trusses Exc.10 but n.exc 15 m Span and similar work.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
S&F Joist, channel, angle or tee sections fixed independently without connecting plates etc. complete all as specified, conforming Fe 410W (Gde E-250) Quality B complete all as specified and as directed
M & L Preparation of new or previously untreated surfaces & priming with red oxide and applying two coats of synthetic enamel paint of any description, over 10 cm in width or girth, not otherwise described complete all as specified and as directed.
Supply and erection aluminium base Roof ventilator containing 42 blades with grease free ball bearings fixing with self tapping screws with sealant complete all as specified and as directed
Preparation of old painted steel and iron based surfaces of any description over 10cm width of girth and applying one coat of synthetic enamel paint complete all as specified.
Surface Excavation, n exc 30cm deep and averaging 15 cm deep and getting out soft/loose soil complete
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
Rolling and consilidating formation in cutting with power roller 8 to 12 Ton to required level gradient and camber complete all as specified and as directed
M & L for Soling (or sub base) 150 mm thick (spred thickness) with broken boulders or quarried stone interstices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed
M & L for 75mm thick (compacted thickness) WBM with coarse aggragate (limestone, sand stone, flint or quartzite) of grading 2 (63 to 40mm size) spread, rolled and consolidated to gradient and camber required with power roller 8 to 12 Ton complete all as specified and as directed
M&L for Premix bituminous,macadam binder content 4% by weight of total mix laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less rolled and consolidated with 8 to 12 tone power roller, complete all as specified and as directed
M/L preparing surfaces by brushing with wire brushed for removing caked mud etc sweeping with brooms and finally fanning to cleaned surface with gunny bags to remove all loose dirt etc from unsurfaced water bound macadam complete all as specified and directed.
Applying evenly a premix /tack coat with bituminous primer (using paving bitumen ) 10 Kg per ten Sqm complete all as specified and as directed.
M&L Preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc and applying evenly a priming/tack coat with bituminous primer at 05 kg per 10 sq metre complete all as specified and directed.
M & L Bituminous premix asphaltic semi-dense concrete 25 mm consolidated thickness with 5.5% binder content of paving bitumen any penetration by weight of total mix, rolled and compacted to required camber and gradient complete all as specified and directed by Engr-in-Charge.
M&L for 2.5mm thick road marking strip (Retro reflective) of specified shade/ colour using hot thermoplastic material by fully /semi automatic thermoplastic material applicator machine filled with profile shoe - glass beads dipensers propane tank complete all as specified and as directed.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for
Refixing of old kerb stone with cement mortor (1:4) including necessory PCC complete all as specified and directed.
M&L for pre-cast cement concrete type B1, 1:2:4 (using 20mm graded stone aggregates) as in kerb stone of over all size 450 x 350 x 150mm thick including chamfers, weatherings, throating etc and setting in cement mortor 1:4 complete with joints to match complete all as specified and as directed.
Preparation of new concrete surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Refixing of MS work obtain from (above Item no 82) frame work complete all as directed
S&F Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors,ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F Convex mirror 60cm dia with rain protection, polycarbonate materials and fixing mirror in stainless steel pipe 40mm dia height of pipe 1200mm - 1500mm, inside ground minimum 60 cm with cement concrete 1:3:6 making good surface including removing excavated material/debris including all necessary fittings complete all as specified and as directed by Engineer-in-Charge
Taking down carefully aluminium point wiring (light,fan, socket or power) complet with fittings such as switch,socker, celingrose and making good the disturbed surfaces of wall/celing ect,complete all as specifed and directed
Point wiring complete with Multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed,FRLSH cable , 1100 volts grade conforming to IS 694 multistranded , drawn in and including rigid PVC surface type conduit / casing capping on walls/ floors/ ceiling etcwith and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly, cutting chasis to the wall s/ floors/ ceiling and repairing with existing surface after work ,complete all as specified and directed.
One light point controlled by one switch
One fan/exhaust fan point controlled by one switch
All as per ser item No 86 above, but using 4 sqmm PVC insulated unsheathed, multistranded copper conductor cable with 4 sqmm continuous earth conductor for one 3 pin 15 amps socket outlet on an independent board
Supply and fixing of switch modular 1 way 6 amps, 1 module with frame and cover 230 volts complete all as specified
Supply & fix ceiling rose surface backlite three terminal complete all as directed
Supply and fixing of switch modular 1 way 16 amps, 1 module with frame and cover 230 volts complete all as specified
Supply and fixing of socket modular 6/16 Amps 2/3 pin combined 2 module with frame and cover 230 volts grade complete all as specified
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories 230V, 1200mm sweep. Minimum air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless motor (BLDC) complete all as specified and as directed.
Supply & fix LED tube light along with fixture 1 x 20 W complete all as specified and as directed.
M&L for submain wiring with 2 runs of 4.0 sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. Note : 2 runs of 4 sqmm PVC insulated unsheathed copper conductor and 1 run of 4.0sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
M&L for submain wiring with 2 runs of 6.0 sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of 6.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. Note : 2 runs of 6 sqmm PVC insulated unsheathed copper conductor and 1 run of 6.0sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
Supply and fix MCCB 160 amps 25 KA breaking capacity with Thermal based release 4 pole 415 volts 50 HZ sutable enclosure fixed on wall/panel all as specified all as specified and as directed
Supply & install pedestal type angle iron frame with legs made of 25x5mm upto 1.5mtr height including fixing arrangements on floor grouting with suitable size of bolt nuts for mounting sheet metal enclosure for accomodating 32 amps rating MCCB complete all as specified and as directed compising the following. (a) sheet metal enclosure suitable for mounting MCCB 32 amps capacity 01.no
Supply and laying XLPE insulated armoured 1100 volts Grade LT UG Cable of following sizes :-
(a) 25 Sqmm , 4 Core for High bay light fitting
(b) 16 Sqmm , 4 Core for flood light fitting
Supply and fix in replacement of DOL stater upto 02 HP complete including making connection all as specified and as directed
Supply and fix 14 SWG, 50mm GI. Hot Dip/powder coated perforated typle tray for XLPE cable along wall to DB, 75 mm including all acessories TEE/SADDLES/fitting items etc .all as specified by Enger-in -charge
Supply and fix entire drum assembly, consisting of round pipe, brackets, flange assembly, roller chains etc., automated with suitable motor for lifting of capacity 800 kg of motor model : CS-600 (imported make) operated with push button switch all as specified and directed by Engr-in-charge. Size of rolling shutter required - Breadth 3260 mm and height 4260 mm
M & L for taking out existing old vintage/unserviceable LT panel board with all unserviceable control switches complete after taking proper shut down of electric supply and disconnecting all in coming/ out going connections & keeping in safe custody complete all as specified and as directed.
M & L for taking down existing old/existing ceiling fan any sweep from the ceiling and kept in safe custody and making good the disturbed surfaces of ceiling etc complete all as specified and as directed
M & L for re fixing ceiling fan any sweep on ceiling after reparing/servicing in work shop by rewinding/servicing and replacement of bush, bearing, rubber bush, nuts, bolts and washers, and small spares as required and making ceiling fan serviceable including three core flexible wire from ceiling rose to fan all as specified and as directed Note : Ceiling fan dismantled against item No 108 will be re fixed
Earthing complete with 600x600x6.00MM thick GI earth plate electrode buried directly in ground not less than 2.25 mtr below GL with the top edge of the plate at a depth not less than 1.5 mtr from GL, connected to GI earth lead of 4.0 mm dia by means of nuts, bolts, washers, checknuts etc, made out of galvanised iron or steel, earth wire protected by galvanised iron pipe, connected to main switch board complete including necessary earth work,excavation,PCC chamber, watering pipe, funnel, wire mesh, RCC chamber cover etc all as specified and directed in EP No:3 of SSR Part-I
Siddivinayaka Constructions
Shiva Shakthi Electrical Enterprises
B C MOHAN
R R Constructions
Meghana and Gowda Enterprises
G K CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .