SE EUCC V LESA LUCKNOW
Lesa Bhawan Near Residency
For Construction of 33 kv Bay and other related work at 33/11 kv substation Ambedkar University Utrethiya Lucknow and other associated work
2020_MVVNL_428835_1
36/EUCC V/2019-20
Open Tender
Electrical Works
30 days
Ambedkar University Utrethiya Lucknow
as per tender document
2 documents required · 2 mandatory
₹1,180
A/c. No. 00500200000456 IFSC CODE. BARBOHAZARA BOB
₹4,000
3 Feb 2020
28 Jan 2020
3 Feb 2020
28 Jan 2020
3 Feb 2020
28 Jan 2020
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
33 KV 3x300 Sqmm XLPE cable
33 KV Termination Outdoor kit
33 KV VCB 800 Amp.
33KV Current Transformer 400/200/1
33 KV Control pannel single Circuit Feeder
33 KV Line Isolator
33 KV Bus Isolator
33 KV Lightening Arrester 400 Amp.
Disc Insulator B&S type 70 KN
Disc Fitting B&S type 70 KN for Panther Conductor
ACSR Panther Conductor for Bus Bar
MS Channel 125x65mm 3.5m long 4 Nos Pieces [email protected] Kg. Mtr. With wastage
MS Angle 75x75x6, 2.6M 2 Nos Total [email protected] Kg./M with wastage
MS channel 100x50 mm
MS Channel 125x65mm 3.5m long 2 Nos. 7M @ 13.1 Kg. Mtr.
MS Angle 75x75x6 2.6M long 2 Nos. [email protected] Kg./M
Rail 105 lb 9 mtr long
M.S.Channel 125x65x6 mm
M.S. Angle 65x65x6 mm
11KV Disc Insulator B &S. Type 7000 Kg
Disc Fittings 70 KN B&S
Cutting shaping, laying and welding of riser GI strip of size 50x6 mm in between earth mat/boring type earthing and equipments/structure/body of T/F for earthing. Two nos Riser for each structure equipment individually (Required GI strip will be provided by contractor).
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation of bolts for erection of 33KV VCB.
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt)
Fabrication of lightning arrestor/CT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.
Painting of all structures equipment.
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work including fabrication work if required for proper operation of equipment
33 KV VCB
33 KV Current Transformer 400/200/1 A
33KV lightning Arrestors
Bus/Line Isolator
Dragging of panels from following unloading place upto control room and placement, erection, grouting, commissioning and testing of the same as per RESPO Norms
33 KV control panel single feeder
Fabrication, erection, grouting and plinthing of following structure as per RESPO drawing (only MS channel ,Angle supplied by Deptt).
33KV Bus bar gantry
Stringing, sagging, jumpering of bus bar gantry with ACSR panther conductor 3Phase 3wire (required PG clamps will be provided by contractor).
Jumpering complete line bay with ACSR panther Cond. with required clamp, nut & Bolts from 33 KV existing bus bar & 33 KV cable complete work.(1 no. line bay)(required PG clamps will be provided by contractor).
Laying of single circuit 33 KV 3x300 sq mm XLPE cable in normal soil in switch yard as per norms. Cable trench should filled by fine sand.
Hoisting, jumpering, clamping of 33 KV 3x300 sq mm XLPE cable on cable stand/structure with proper jumpering with help of PG clamps (required PG clamps will be provided by contractor).
Construction of cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
Laying of copper control cable of following sizes its proper dressing, ferruling and connection with the system (cable will be provided by contractor).
2x2.5 sq mm
4x2.5 sq mm
6x2.5 sq mm
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing included in the job as per specification/norms for CT/LA and other.
Replacement of damaged lightening arrestor.
High pressure testing of cables
S M ENTERPRISES