Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Tender fees and Earnest money as per tender document not uploaded |
Tender Value
₹2.0 L
EMD Value
₹4,080
Closing Date
25 Oct 2022, 2:30 pmClosed
CUSTODIAN JAMMU
CUSTODIAN JAMMU
Internal Electrification to 04 Nos Additioanl rooms with attached bathroom at Tawi Mahal Banquest Hall on EP Land at Udheywala Jammu
2022_CEPS_192716_2
01 of 2022-2023
Open Tender
Electrical Works
Item Rate
10 days
Jammu
Please refer Tender documents.
3 documents required · 3 mandatory
₹700
Yes
As per eNIT
₹4,080
Yes
27 Oct 2022
17 Oct 2022
25 Oct 2022
17 Oct 2022
25 Oct 2022
17 Oct 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Cost of earthing wire and PVC Conduit excluded)
Group A
Group B
Group C
Wiring for light / power plug with 2x4 sq.mm. FRLS PVC insulated, copper conductor, single core cable in surface/recessed medium class PVC conduit along with 1 No. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required
Wiring for light/power plug with 3x2.5 sq.mm FRLS PVC insulated, copper conductor, single core cable in surface/recessed steel conduit along with 2 nos. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required
A. 2x4.0 sq.mm+ 1x4.0 sq.mm. earth wire
B. 2x10 sq.mm+ 1x6 sq.mm. earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
A. 5/6 A Switch
B. 5/6 A 5-pin Socket outlet
C. 15/16A Switch
D. 15/16A 6-pin Socket outlet
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required.
Installation, testing and commissioning of pre-wired, flourescent fitting/compact flourescent fitting of all types, with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable and earthing etc, as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable, incuding providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I.pipe, 15 mm dia, heavygauge including painting etc. as required.(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Supplying and fixing 5 amps. to 32 amps. rating, 240/415 volts, 'C' curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
A. Single pole
B. Double pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required : (In Rooms for AC)
Supplying and fixing following rating, four pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required :
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Note :All Wires/MCB's,SPN etc used in above items to be of Havells, V-Guard or Great White Make Only All Wires used in above items should be of Havells/V-Guard/ Great White make only
Supply of following duty and sizes of Exhaust Fans complete with motor, capacitor, terminal block, shuttered louvers etc. complete as required.
300 mm sweep 1400 r.p.m (LMR)
Supply of following sizes of ceiling fans complete with fan motor, capacitor of required rating, terminal block, standard down rod, wiring of down rod, fixing hooks with nuts & bolts, rubber bush, shrouding caps etc. complete as required.
1200 mm dia sweep (LMR)
Supply of Ornamental Type Fancy looking Wall mounted Bracket containing upto 2CFL/LED Lamps per Fitting, complete withh all accessories (LMR)
Providing and Fitting roof mounted MS Round Box/ Fan Box/ Concealed Box in RCC Slab incl accessories (LMR)
Supply of following of prewired light fittings/ light tracks, complete with all accessories such as side holders, ballast, wherever required, complete factory wired with copper conductor as required with lamp.
Make : HAVELL'S OR EQUIVALENT
Lamp : 7 W Round LED PANEL (LMR)
Lamp : 12 W Round LED PANEL (LMR)
Make : HAVELL'S OR EQUIVALENT
Lamp : 1X28W T5 (SLIM) (LMR)
Make : HAVELL'S OR EQUIVALENT
Lamp : 7 W LED Bulb (LMR)
SHARAT PURI CONTRACTORS
M/s delta generation
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .