Executive Engineer
Township Division, BBMB, Talwara Township
Renovation of House No 2T8 3 No T7 10 No T6 type houses by providing and fixing tiles and interior exterior including construction of boundary wall in T8 and T7 type house along with construction of 2 No Guard Room with toilets
2023_BBMB_95242_1
NIT NO. 166/2022-23
Open Tender
Civil Works
Tender cum Auction
270 days
Talwara Township
terms and conditions attached
2 documents required · 2 mandatory
₹2,360
₹1.9 L
27 Mar 2023
16 Jan 2023
10 Feb 2023
16 Jan 2023
10 Feb 2023
16 Jan 2023
16 Jan 2023 - 10 Feb 2023
Amount
Nicking cement concrete surface (over 28 days old including preparation and laying slurry) [CSR item No.-10.31]
Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. ( CSR item No. 30.95)
Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. ( CSR Item NO. 30.94)
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Soluble Salt Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Soluble salt Print Penetration should be up to 1 to 2 mm after the tiles are fired & polished ).[ CSR 14.112]
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.{ CSR No. 14.125}
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.[CSR item No.-6.6)
Earth filling under floors with surplus soil containing more than 40% gravel or kankar excavated from foundation & taken only from outside the building plinth in 15 cm layers including ramming watering and consolidation lead upto 30 metres ( CSR Item No. 6.8(ii)
Cement concrete 1:6:12( b)With stone aggregate 40mm gauge (ii) mixing by mechanical means using concrete mixer volumetric type ( CSR Item No. 10.8(b) (ii)
Cement Concrete 1:8:16 with 40mm gauge stone aggregate using concrete mixer volumetric type [CSR item No. 10.6 (b) ii
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth [CSR item No. 11.3( i)]
Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded [CSR item No. 10.26]
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. (CSR Item Npo. 11.4(i)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. ( CSR Item No. 10.15( A &C-1-2020)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.( CSR Item No. 9.8)
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete CSR Item No. 18.18
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. CSR Item No.13.55)
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 ( CSR Item No. 13.45)
Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 ( CSR Item No. 13.51)
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) CSR Item No. 13.74)
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. CSR Item No. 13.75 (a)UPVC 110 mm bend
Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. CSR Item No. 13.76 a) UPVC 110 mm bend
1.2 meter high G.I. barbed wire fencing with 1.8 meter angle iron posts 40x40x6mm placed every 3 meters centre to centre 0.6 meter below ground level, every 15th post, end post, corner post suitably strutted and provided with 9 horizontal lines and two diagonals interwoven with horizontal wires fixed with GI staples, turn buckles etc. including foundation concrete 1:2:4 of size 0.30x0.30x0.75m for each post complete as per technical clause 808 of MORT&H specifications [CSR item No.24.43.a)]
12.5 mm thick cement plaster 1:5 [CSR item No. 15.10]
Scraping (CSR Item No. 8.31 © Cement plaster
Cement concrete 1:2:4 with stone ballast or single using concrete mixer volumetric type [CSR item No. 10.13a (ii) A&C-1
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pilasters buttresses etc [CSR item No. 9.2]
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish. [ CSR Item No. 16.65 ]
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade.[CSR item No. 16.10] A &C-1
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.[CSR item No. 16.18]
Scraping ( CSR Item No. 8.31) (a)White wash and colour wash ( Same as qty No. 15
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete CSR Item No. 18.24 (c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Red meranti Normal (15 to 16 kg per cft. Approx.) doors shutter with 12mm thick phenol Bonded BWP ply (Anchor Kit ply, Nova teak , or National or any other ISI approved quality) I/C hinges, screws, chocks & cords etc. Complete fixed in position (Single leaf) (CSR Item No. 17.10 (x) (ii) 35 mm thick
Supplying openable steel windows, of standard rolled steel Z sections, joints mitered and Electrically flash-welded, with iron fittings including necessary iron handles, Peg-stay catchers bolts, iron plugs and pressed steel projected hinges and glazing clips, complete (Excluding glazing ) and finished with two coats of ready mixed paint red lead non setting primer (CSR Item No.18.20) b) Above one sqm Area
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (CSR Item NO. 18.4)
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. (CSR Item No.18.25 b) Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete(CSR Item No. 17.43(a)ISI designation no I (Size of door up to 700mm)
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : (CSR Item No. 17.49 (a) 300X16 mm
Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge.[ CSR item No. 13.91]
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footoaths). ( CSR Item No. 14.137)
Cement concrete 1:6:12 ( CSR Item No. 10.8 b (ii)
Dismantling concrete ( CSR Item NO. 8.6 b)
Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ( CSR Item No. 13.27 (iii) b)0.60 mm (+ 0.05 %) thick
Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) (CSR Item No. 18.11 (a)
Cement Pointing 1:3 deep Variety (CSR Item 15.60 )
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade (CSR Item No. 16.13) A &C-1
Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fitting complete in all respects15mm internal diameter pipe line. [CSR item No.28.63(a)]
-do- 20mm internal diameter pipe line.[CSR item No.28.63(b)]
Cutting Chase in brick walls in cement or in floor for embedding G.I or C.I pipes line and making good the same to its original condition.(CSR—30.85) a. Size 75x75 mm.
Providing, fixing and jointing G.I. Union couplings (of approved made with the approval EIC) as per IS 1879 in G.I. pipe lines complete in all respect. 20mm i/d G.I. Union [CSR item No. 28.40(b)]
Providing, fixing and jointing G.I. Union couplings (of approved made with the approval EIC) as per IS 1879 in G.I. pipe lines complete in all respect. 15mm i/d G.I. Union [CSR item No. 28.40(a)]
Providing, fixing and jointing ISI Marked Gun-Metal peat valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. pipe lines laid in the ground or inside buildings including all carriages complete. 20 mm I/D Gun metal peat valve heavy pattern[CSR item No.-28.43(b)]
Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B- Class including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete 15mm i/d [CSR Item No. 28.35(a)]
-do- 20mm i/d.[CSR Item No. 28.35(b)]
Providing and fixing in position C.P brass extension piece 25mm long to 50 mm long of approved make (To the Approval of Engineer-in-charge) with various fixtures complete in all respect ( CSR 30.64 B)( i)
Providing & Fixing in postion stop cock /Angle valve of approved make (to theapproval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Concealed stop cock with flange.CSR 30.66 (b)
Providing & Fixing in postion stop cock /Angle valve of approved make (to theapproval of Engineer-in-charge ) complete in all respect C.P.brass 15mm stop cock Male and female end CSR 30.66 (a)
Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. brass wall mixer without telephonic shower CSR 30.46(b)
Providing and fixing in position C.P. brass overhead shower arm chrome round or square with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. CP Brass rain Fall Shower arm 18" length square chrome CSR 30.56D(V)
Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity.(without cistern fitting) with P trap or S trap of approved make (to the approval of the (Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware Floor Mounted One Piece EWC rim less type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting)size 69x36x74 cm with P trap or S trap and seat cover complete in all respect CSR 30.3 (b)
Providing and fixing stainless steel Health faucet complete in all respect. (CSR- 30.24)
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 550 mm x 400 mm x 815 mm CSR item no 30.32 (ii)
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash h36nd basin complete in all respect( CSR item no. 30.43(i)Vitreous chinaware standard white pedestal for wash hand basin
Providing and fixing in position C.P brass basin mixer without pop-up waste system with 450 mm long flexible hose of approved make (to the approval of Engineer-in-charge) instead of C.P. brass pillar tap complete in all respect. CSR item no. 30.38
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect .C.P. brass Bib cock foam flow without flange CSR 30.65A(ii)
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. [CSR item No. 30.80]
Providing and fixing in position 5mm thick beveled edge mirror of superior glass(of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P brass screws and washers and S/S studs on top complete in all respect (as required by the Engineer-in-charge)(CSR-30.61(a)) Size 600mmx 450mm
Providing and fixing P.V.C Waste Pipe Collapsible 32mm complete in all respect. (CSR-30.20)
Providing and fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) complete in all respect. (CSR-30.72) (b) PVC tube connection of size 15mm x 450mm with C.P Brass nut.
Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect .C.P. brass toilet paper holder CSR 30.57 (a)
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste Coupling 30.47 (c)
Providing & fixing in position C.P brass Sink mixer swivel spout (Wall mounted) of approved make (to the approval of Engineer in- charge) complete in all respect. CSR 30.50
Providing and fixing in position towel rails /ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P brass towel ring CSR 30.58 (b)
Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs and C.P brass screws complete in all respect.CP brass Acrylic Shelf size 560 mm x 130mm CSR 30.59 (a)
Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs and C.P brass screws complete in all respect. C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm CSR 30.59 (b)
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws Complete in all respect. CSR 30.60.
Providing and fixing in position C.P. brass Tumbler Holder of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect CSR 30.22
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws Complete in all respect. C.P. brass towel bracket (610mm long) CSR. 30.58 (d)
Providing and fixing in position C.P/ Aluminum Khunti of approved make (to the approval of Engineer-in-charge) fixed into wall with C.P brass screws and rawl plugs etc. complete in all respect. C.P. brass khunti with 6 pegs [(CSR- 30.63)c]
Providing and fixing in position storage type automatic electric water heater pressure non pressure type thermostatically controlled single phase vertical wall mounted of approved make (to the approval of engineer-in-charge) with thermostats, inner container of stainless steel complete with 1 mtr three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.(CSR 30.101(a) 25 Ltr capacity water heater.
Providing and placing in position on terrace ( at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and base support for tank. (CSR-30.97A (i)) Triple layer Tanks.
Providing and fixing in position G.I tank Nipple of approved make (to the approval of Engineer-in-charge) complete in all respect. G.I tank nipple 20 mm i/d (CSR-30.98(b))
Providing and fixing in position automatic brass ball cock in Tanks. brass ball cock with rod and plastic ball 20mm i/d(CSR-30.96B) (ii)]
Providing and fixing jet spray with 2'-6" long PVC pipe. (CSR Item No30.8 (a)With C.P. Brass nut
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.(CSR Item No. 30.4)
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. CSR Item No. 28.18 (iv) 110mm o/d pipe of 10 Kgf. / sqcm
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. CSR Item No. 28.12(d) 40mm i/d
Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5 sq.mm 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc. complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lungs) required for suitable number of modules (Modular accessories) for having step type electronic fan regulators (Two Module) 100 watt, bell push, 6 Amp. 2/ 3 universal socket (Shuttered), 16/20Amp.combined universal socket (Shuttered) , 6/10 Amp switches, 16/20 Amp. Switches (with indicator) etc. and covered with frame plate etc. PVC connector ( For fan box and call bell), steel hooks, sheet metal fan box ( 1.6mm thick shape hexagonal), circular junction boxes ( Four way PVC 1.6” deep for walls & 3” deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable ( ISI Marked) 1sq.mm 11000 v grade( For 6 Amp wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases ( with finishing the surface):- CSR Item 34.02 Wiring fan point without fan box.
Wiring light point.
Wiring call bell point
Wiring 3 pin 6 Amp. Wall socket point
Wiring 3 pin 16/20 Amp. Power plug control point.
Wiring light with double control switches.
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface) CSR Item No. 34.01 ix) Wiring AC supply terminal having 1 No. 25Amp. Universal socket (shuttered) erected at AC height and 1No. motor starter 25Amp. erected at switch height.
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): CSR Item No. 34.01(Xi) Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): (a) Wiring TV socket point (one module)
Wiring Telephone RJ11 socket point (one module).
Wiring Networking socket point RJ45 (one module)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge: (CSR Item 34.09) i) Overall 1 sq.mm (Un sheathed).
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications: CSR Item No. 34.12 (X) Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: A ) MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: (CSR ITem No. 34.16)ii)MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB double pole 50/63 amp (Breaking capacity 10 kA, curve-c
MCB TNP, 63amp. (Breaking capacity 10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc: (csr Item No. 34.17)viii) TP&N Horizontal Double Door Distribution Board 12 way each
SPBN Horizontal double door distribution board 12 way.
Bidder Name
Amount in Words
RAM PARSHAD VERMA GOVT CONTRACTOR
sanjiv kumar govt contractor
Rahul Verma Govt. Contractor
Rahul Verma Govt. Contractor
sanjiv kumar govt contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .