Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹12.9 L+₹1.1 L (9.39%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹13.9 L+₹2.1 L (18.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹14.0 L+₹2.3 L (19.3%)Rejected-Finance MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
2 Oct 2021, 6:00 pmClosed
GE (AF) Jammu
Air Force Station Jammu
CA NO GE/AFJ-03/2021-22 MANNING AND OPERATION OF E/M INSTALLATION FOR ELECTRIC SUPPLY,WATER SUPPLY AND DG SET AT SHASHITAR UNDER GE (AF) JAMMU
2021_MES_448190_2
CA NO GE/AFJ-03/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Shashitar under GE (AF) Jammu
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Jammu
₹40,000
Yes
14 Oct 2021
11 Sept 2021
4 Oct 2021
11 Sept 2021
2 Oct 2021
18 Sept 2021
Amount
Manning and operation of Electrical and Water Supply installation at shashitar round the clock with deployment of operating staff in three shifts (8 hours in each shift) per day from 0600 hrs to 1400 hrs (Ist Shift), 1400 hrs to 2200 hrs (2nd Shift), 2200 hrs to 0600 hrs (3rd Shift) including attending of electrical complaints and carrying out minor electrical repair work to keep installation functional and for providing trouble free electric/ water supply services to user and cleaning of installation and surronding area complete with following duties:
(a) Operation of DG Set in case of power failure from SED and attending and rectifying day to complaints of electric & water supply (b) Operation of Pump House and water supply installation including pumping of water to overhead tanks and opening/ closing of valves for distribution to unit area all as directed by Engineer - in - Charge. (c) Periodical inspection and maintenance of recores thereof Electrical and water supply Installation Machines. (d) Periodical checking of earthing of electrical equipments and maintaining records thereof. (e) Operations of GODs and replacement of GOD fuses if required. (f) Filling of diesel/ POL in the DG Set and Maintenance of daily log sheet and record of DG Set and Sub Stn. (g) Checking and Repairing Street Light and Security light fittings (Labour Only) (h) Inspection and Maintenance of Earthing Pits (j) Any other work necessary for restoration of elect/water supply all as specified and directed by Engr in Charge:-
1. Operating staff required as under :-
(a) Electrician (Skilled) - 01 Per Shift
(b) Helper for Electrician - 01 Per Shift
Note :- (i) Electrician should be technically qualified (having Govt approved ITI qualified having minimum two years experience/ a person having seven years experience in the relavant trade/ Ex - service man of the relevant trade and original certificate to this effect to be verified by Engineer-in-Charge before handing over the site) and Contractor has to provide them all the required electrical T & P and safety equipments (Shorting rod, HT PVC globs, Safety Belts, Ladder, crash halmet, etc) and Bicycle/vehicle to attend the complaint.
(ii):- The personnel employed by the Contractor must have Aadhar number and bank account. (iii):- Contractor Shall install & Maintain digital Bio-metric attendance systems at the installation as required to record the attendance of the personnel and authorised admin for Bio matric machine will be the concern JE E/M Incharge of the installation all as directed by Engineer Incharge. Expenditure in this effect shall be included in quoted rate. (iv)- It is an express condition of the contract that payment of wages to tradesmans/workers deployed at site of work shall be made through bank account of individuals only. The contractor deposit/ distribute the payment in first week of every month and will confirm to Engr-in-Charge by submitting the bank transaction document from bank. The salary paid to the trademen /worker shall not be less than minimum wages/fair wages as notified time to time by Govt. (v):- Contractor shall follow the updated Govt Labour Act strictly.
M & L for Repair, maintenece and servicing of Split type Air conditioner/Window type unit of any capacity upto 2 TON outer and inner unit both of any make including cleaning the dust from body with blower, cleaning of condenser and cooling coil, checking all connections including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor, fan/blower drum, main control board PCB, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of warn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-Charge. (Note: Spares parts replaced shall be measured & paid under saperate item)
Replacement of old unseviceable / damage hermatic sealed compressor with new hermatic sealed unit 2 Ton , capacity and any specifications, including taking down unsv hermatic sealed unit complete all as specified and directed by Engineer-In-Charge.
Repalcement of old unsv/damage PCB with new PCB for split air conditioner of capacity 2 ton and any type any specification including taking down old unsv PCB, complete all as specified and directed by Engr -in - charge .
M & L for Detecting the gas leakage, rectifying the defects including repair to condensor coil/evaporator coil by means of welding, soldring etc, vacumizing and charging, topping up fresh freon Gas and commissioning and testing for split type/window type AC all as specified and directed by Engineer In Charge
Supply and fixing of Distribution board sheet steel phosphated powder painted for MCB / DB with copper bus bar and neutral link earthing stud (confirming to IS - 13032, IS - 8623) SPN 8 Way 240 Volts double door and taking down old/unsv DB any way complete all as specified.
Supply and fixing of Distribution board sheet steel phosphated powder painted for MCB / DB with copper bus bar and neutral link earthing stud (confirming to IS - 13032, IS - 8623) SPN 12 Way 240 Volts double door including taking down old/ unsv DB any way complete all as specified.
Supply and fixing MCB single pole and neutral 240 volts, 50 Hz of rating 32 amps, with rupturing capacity 10 KA `C' series including providing thimble for cables and taking down old/ unsv mcb any cap and rating. , complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB single pole 240 volts, 50 Hz of rating 06 to 32 Amps, with rupturing capacity 10 KA `C' series including providing thimble for cables and taking down old /unsv mcb any cap and rating. complete, all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCCB having current ratings 63 Amps with rupturing cap 16 KA , AC 415 Volts three pole all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge.
Supply, laying in trenches or fixed to wall/ pole or passing through pipes jointing, testing and commissioning of XLPE insulated, screened PVC bedded, galvanised steel strip armoured heavy duty (1100 volts grade) electric cable with aluminium conductor of size 35 Sqmm 3.5 Core including taking out old LT Cable of any size complete all as specified and directed by Engineer-in-Charge. Make : Havells/ CCI/ Gloster
Supply, laying in trenches or fixed to wall/ pole or passing through pipes jointing, testing and commissioning of XLPE insulated, screened PVC bedded, galvanised steel strip armoured heavy duty (1100 volts grade) electric cable with aluminium conductor of size 10 Sqmm 4 Core including taking out old LT Cable of any size complete all as specified and directed by Engineer-in-Charge. Make : Havells/ CCI/ Gloster
Supply and laying of DWC(Double wall corrugated) HDPE pipe ISI marked IS 14930 Par-II of outer dia 50 mm and inner dia 38 mm with smooth internal and profiled external surface for non-pressure underground cables including all connected accessories like coupler "O"ring etc for protection of cables complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
NATIONAL TRADING COMPANY
M/S GRD ENGINEERS
M/S KIRAN CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .