| 1 | L1₹49.6 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹50.0 L+₹8,286 (0.17%)Rejected-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹50.0 L+₹8,641 (0.17%)Rejected-Finance | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹50.0 L+₹9,016 (0.18%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-Finance rejected being L4 | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
30 Jan 2021, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
REPAIR MAINT OF ELECTRICAL FITTINGS AND FIXTURES INCLUDING REPAIR MAINT OF CONTROL PANEL OF AC PLANT COMPREHENSIVE MAINTENANCE AT NIRBHAY AND RUSTOM II AIR CONDITIONING PLANT AND MISC ALLIED WORKS AT ADE DEBEL BANGALORE
2021_MES_410642_1
8986
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D East Bangalore
D b (i) c (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹96,000
Yes
4 Mar 2021
8 Jan 2021
2 Feb 2021
8 Jan 2021
30 Jan 2021
23 Jan 2021
9 Jan 2021 - 20 Jan 2021
Amount
M & L for Periodical maintenance and servicing on monthly basis of Air Handling Unit (AHU) floor mounted of any make and model like checking and cleaning of air filter ,motor including checking proper electrical connection, checking/tightening of all nut and bolt , checking of solonoid valve etc, a checking of proper functioning of electrical control panel, checking/cleaning of pre filter with soap solution and complete removing of dust particle (twice in a month), and routine checking to ensure smooth running of AHU including preparation of monthly inspection report in the register as per proper format for each AHU plant installed at following locations complete all as specified and as directed. (a) AHU 48 TR -02 Nos at Nirbhay hanger (b) AHU 45 TR -02 Nos at RUSTOM-II Note:- The maintenance of all AHU (Total 04 Nos ) shall be catered as each job.
M & L for Periodical maintenance on monthly basis of cassette type AC upto 4 TR of any capacity like checking for proper electrical connection, checking/tightening of V belt, checking refrigerant pipe line, arresting refrigerant gas leakage if any, checking of proper functioning of electrical control panel, checking/cleaning of pre filter (twice in a month), cleaning of out door unit with soap solution and routine checking to ensure smooth running of package AC plants including preparation of monthly inspection report in the register as per proper format for each plant installed at following locations complete all as specified and as directed. (a) Cassette type AC upto 4 TR at Rustom II- Total 17 Nos (b) Cassette type AC upto 4 TR at Rustom II- Total 12 Nos Note:- The maintenance of all Casette type AC (Total 29 Nos ) shall be catered as each job.
M & L for Periodical maintenance of Central AC plants with air cooled screw chiller of any capacity like checking for proper electrical connection by a auth rep of OEM of AC plant checking/tightening of V belt, checking refrigerant pipe line, arresting refrigerant gas leakage if any, checking of proper functioning of electrical control panel, checking/cleaning of pre filter (twice in a month), cleaning of out door unit with soap solution and routine checking to ensure smooth running of Centre AC plants including preparation of monthly inspection report in the register as per proper format for each plant installed at following locations complete all as specified and as directed (a) Central type AC 120 TR + 60 TR as standby at RUSTOM II (b) Central type AC 120 TR + 60 TR as standby at NIRBHAY Note: Replacement of minor unserviceable spare parts upto costing Rs 1000 per month shall be given by contractor
M & L for taking down and disconnecting of all existing LT Cables of any sizes / of any capacity from LT Panel board with out any damaging to other equipments and reconnection of the same after complete the job all as specified and as directed.
Supply and fix in replacement of FASD starter of cap 30 HP to 40 HP complete with auxilary contract,Relay , timer, for compressor including making all connection and control wiring with compressor as per existing all as specified and directed . Make : Schneider/Seimens/ABB/L&T
Supply and fix in replacement of FASD starter of cap 7.5 HP to 15 HP complete with auxilary contract,Relay , timer, for compressor including making all connection and control wiring with compressor as per existing all as specified and directed . Make : Schneider/Seimens/ABB/L&T
(g) MCB 3 Pole 63 Amp 25 KA, 415 Volt, 50 HZ including making connection for heater and interlocking wiring complete as per existing -02 Nos ( These MCB will be assemble in single compartment) Make : Schneider/Seimens/ABB/L&T&T (j) Indication : Green (ON) & Red (OFF) for main ACB (l) Complete internal wiring with suitable copper condutor wires - 1 Lot Note : (i) All termination of existing cable should be provided with Aluminium lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item. (ii) The rate quoted by the contractor is deemed to be inclusive for disconnecting unserviceable panel after taking out existing LT Cables from unserviceable panel/duct/trenches and reconnectiong the existing cables to new panel including keeping safe unserviceable panel in custody. iii) Before installing/commissiong drawing of panel shall be approved by GE.
Taking down the existing steel rolling shutters from brackets with connecting rod for servicing and fixing only suspension shaft of 50mm dia GI pipe heavy grade, helical springs, bearings etc., servicing for free movement and smooth function of rolling shutter and fixing unit in original position etc., complete, area not exc 10 Sq m each.
All as item No.09 above but area exc 10 Sqm and n.exc 20 Sqm
All as item No.09 above but exc 20 Sqm
Taking down collapsible steel gates/shutters consisting of channel, pickers, pivoted flat bars, top and bottom runners for servicing and checking its function including fixing only new wheels, top and bottom channels, cleaning and greasing of wheels and channels etc., complete and fixing in its original position complete area exc 4.00 Sqm and n.exc 10 Sqm each.
Supply only 50 mm dia galvanised iron pipe heavy duty (ISI marked) suitable for suspension shaft for rolling shutter (length exc 2m and not exc 6 m)
Supply only helical spring for counter balancing the rolling shutter made out of high tension springs, 115mm bore and 600mm long.
Supply only bearing for rolling shutter 75 to 100 mm dia (Make:SKF)
S&F inter-locking lath sections formed from cold rolled steel strips of 1.25mm thick, suitable for rolling shutter, including removing existing damaged laths from rolling shutters and painted with matching paint of existing laths of the shutter complete.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6 mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.3 of SSR part I and earth wire protected by galvanized pipe light grade 40 mm bore and thorugh test point including necessary earth work and excavation in any type of strata, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chember with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed and testing on completion.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 25 x 4 mm complete all as specified and as directed
(g) Indication : Green (ON) & Red (OFF) for main ACB (h) Complete internal wiring with suitable copper condutor wires - 1 Lot Note : (i) All termination of existing cable should be provided with Aluminium lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item. (j) Before installing/commissiong drawing of panel shall be approved by GE.
Supply and fixing in replacement of MCCB 250 Amps from the existing panel/Sub station after removing all electrical connections, unscrewing and fixing new MCCB in existing panel of capacity 4 pole 250 Amps, 415 Volts, 36 KA all as directed. Make L&T/Standard/Legrand/Havells
Supply and fixing in replacement of MCCB 100 Amps from the existing AC control panel after removing all electrical connections, unscrewing and fixing new MCCB in existing panel of capacity 3 pole 100 Amps, 415 Volts, 25 KA all as directed. Make L&T/Standard/Legrand/Havells
Supply and fixing in replacement of MCCB 63 Amps from the existing AC control panel after removing all electrical connections, unscrewing and fixing new MCCB in existing panel of capacity 4 pole 100 Amps, 415 Volts, 25 KA all as directed. Make L&T/Standard/Legrand/Havells
Supply and fix in replacement of single phase preventor 415 volt VSP-3 Ser No 8 F 7037 all as specified and directed.
Supply and fix in replacement of Start /Stop Push putton in the existing panel including making connectiion as per existing all as specified and directed.
Supply and fix in replacement PHASE CT for measuring the LT current in the existing LT AC conrol panel including making all connection all as specified and directed.
Supply and fix in replacement auxilarry relay suitable for FASD starter upto 30 HP including making all connection as per existing make and model all as specified and directed.
Supply & Charging refrigerant gas R-22/407C/134a. Make- Fluron/Mettron/Refron
Supply and fix removable type factory made metalic pre filters of 20 micron of standard size with GI frame both side including taking out unserviceable metalic pre filters etc all as directed. Make- Aerosol/Dyna/Maf/Zonflower
Supply and fix factory made high performance bag filters of 99 micron down to 5 micron of standard size with multiple pockets and self supporitng filters bags with MS / GI anodised aluminium frame suitable for central AC Plant including replacement of bolts and nuts and taking down unserviceable bag filters etc all as directed. Make- Aerosol/Dyna/Maf/Zonflower
Supply and replacement of condenser safety valve up to 350PSI scaled of any size confirming of ISI including evacuating of refrigerant gas all as specified and as directed
Taking down carefully the existing aluminium point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets,ceiling rose, regulators and light fittings any type etc by unscrewing and taken away from site complete. Note :The cost of unserviceable materials will be charged from the contractor against schedule of credit.
M & L for point wiring with 1.5 sqmm (Nominal Area)PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, with non metalic rigid PVC medium duty conduit, Concealed type/ Surface type with accessories such as junction boxes, bends, tees etc. of suitable size of modular terminal box, modular frame, modular cover for mounting of switches, sockets fan regulators etc and including continuous earth wire PVC insulated 1.50 Sq mm copper stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for the following :-
(a) For one light point controlled by one switch
(b) For one fan point controlled by one switch through regulator
(c) For one three pin socket out let 5 amps on same board complete.
(d) For one three pin socket out let 5 amps on independent board complete.
(e) For one Exhaust fan point controlled by one switch
All as per item No 31 here in before, but with cable 2.50 sqmm (nominal area) multi stranded copper wire unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor, connecting to common earth and earth dolly complete.
Supply and fixing of Modular switch piano 6 A,230 V make legrand cat part 573400 or equivalent in anchor,crabtree, Havells
Supply and fixing of Modular switch piano 16 A,230 V make legrand cat part 573410 or equivalent in anchor,crabtree, Havells
Supply and fixing of Modular fan regulator step type 100 w,230 V make legrand cat part 373416 or equivalent in anchor,crabtree, Havells
Supply and fixing of Modular socket piano 6 A,230 V make legrand cat part 573470 or equivalent in anchor,crabtree, Havells
Supply and fixing of Modular socket piano 16 A,230 V make legrand cat part 573471 or equivalent in anchor,crabtree
Supply and fixing of ceiling rose surface type, 3 terminals 65x20mm complete all as specified
Supply and fixing of sheet metal enclosure powder coated, Distribution boards VTPN MCCB 125 A DB, double door, including Provision of TPN MCCB 125 Amps, 25ka as Incomer,8 way, 415V, Double door type IP 43 protection, shrouded Neutral Bar & Pan assembly with flexible link Cement spill protector, Door earthing, complete Make INDOASIAN, Model Optipro F1+ 24 or equivalent of HAVELLS/ L & T/ LEGRAND
Supply and fixing of sheet metal enclosure powder coated, Distribution boards VTPN MCCB 250 A DB, double door, Including Provision of TPN MCCB 250 Amps, 25ka as Incomer,8 way, 415V, Double door type IP 43 protection, shrouded Neutral Bar & Pan assembly with flexible link Cement spill protector, Door earthing, complete Make INDOASIAN, Model Optipro F2+ 24 or equivalent of HAVELLS/ L & T/ LEGRAND
S & F in replacement of Distribution Board, SPN 12 way, 240V, double door type.
S &F in replacement of Distribution Board, SPN 8 way, 240V, double door type.
S & F in replacement of Distribution Board, SPN 6 way, 240V, double door type.
S & F in replacement of Distribution Board, SPN 4 way, 240V, double door type.
S & F in replacement of Distribution Board, TPN 4 way, 240V, type. Double door type.
S & F in replacement of Distribution Board, TPN 6 way, 240V, type. Double door type.
S & F in replacement of Distribution Board, TPN 8 way, 240V, type. Double door type.
Supply and fixing of MCB, SP, 240V, upto 40 Amps 10KA rupturing capacity, 230 Volts
Supply and fixing of MCB, SPN, 240V, upto 40 Amps 10KA rupturing capacity, 230 Volts
Supply and fixing of MCB, TPN, 240V, upto 32 Amps 10KA rupturing capacity. 415 Volts
Supply and fixing of MCB, TPN, 240V, upto 63 Amps 10KA rupturing capacity, 415 Volts
M & L for earthing complete with copper earth plate of size 600 x 600 x 3.15 mm buried directly and preferably vertically in ground with top edge not less than 1.25M below ground level connected with copper earth strip of 20 x 3 mm connected to the earthing test point all as specified and all as directed by Engineer incharge including testing and submission of test reports. Note : The rates quoted are inclusive of copper earth strip upto the standard length as specified in the SSR part -1.However additional length will be measured & paid seperately in respective item.
M & L for copper earth continuity main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit of size 20 x 3 mm all as specified and directed.
Supply and fixing DLP U-PVC Cable trunking systems and acessories snap on trunking 80 x 50 mm supplied without cover, Legrand Cat no : 010412 80mmx50mm PVC Trunking
Supply and fixing of Flexible cover only, full cover size width 65 mm suitable for 80mmx50mm PVC Trunking Make : Legrand Cat no. : 010521
Supply and fixing of Industrial Socket Triple pole and earth enclosure with a three pin and Earth plug with socket complete with one Triple pole MCB. 32 Amps Capacity
Supply and fixing of Industrial Socket Triple pole and earth enclosure with a three pin and Earth plug with socket complete with one Triple pole MCB. 63 Amps Capacity
Supply and fixing of Suspended Linear in Sleek design luminaire 36 watts, Make : CG Model : TREND I, Cat No. : LCLP54-36-CDL or equivalent make in Havells/Wipro/philips
Supply and fixing of LED light 2' X 2' watts, 36 Watts, Slim panel with bright high efficient LED Model : AURA I, CAT REF : CCR-127-36-57-SL-NWH Make : CG or equivalent in HAVELLS/PHILIPS/ WIPRO
Supply and fixing of Flouroscent tube lights 36/40 watts slim type
Supply and fixing of LED tube lights 18/20/22 watts slim type
Supply and fixing of GI pipe bracket made of 40 mm dia bent for L shaped for fixing for fixing street light on pole with proper clamps, bolts & nuts etc all as specified and as directed as per site conditions.
Supply and fixing in replacement of choke 36/40 watts, electronic type
Supply and fixing in replacement of 8 way choke with connector
Supply and fixing in replacement of 36 watts, CFL 4 pin type
Supply and fixing in replacement of 18 watts, LED Lamp pin type
Supply and fixing in replacement of tube light starer 40 watts
Supply and fixing in replacement of tube light starer 110 watts
Supply and fixing in replacement of Switch piano, flush type single pole, one way 5 Amp
Supply and fixing in replacement of Switch piano, flush type single pole, one way 15 Amp
Supply and fixing in replacement of Socket outlet, 2 in 1, 3 pin, 5 Amps flush type
Supply and fixing in replacement of Socket outlet, 2 in 1, 3 pin, 5 & 15 Amps flush type
Supply and fixing in replacement of Modular switch piano 6 A,230 V
Supply and fixing in replacement of Modular switch piano 16 A,230 V
Supply and fixing in replacement of Modular socket piano 6 A,230 V
Supply and fixing in replacement of Modular socket piano 16 A,230 V
Supply & fixing in replacement of Switch socket combination 2 in 1, 3 pin, 5 & 15 Amp, Box type
Supply and fixing Conventional Smoke Detector with Baselow profile design,Low current draw, Wide opening voltage 8 to 30 V DC, Bi - colour LED detectorstatus indicator, tested and approved to EN54. Make : System Sensor, 2351E
Supply and fixing Conventional manual call point,Break glass unit, Alaram status is indicated by Red Colour LED, 24 DC.
Supply and fixing Conventional Hooter, Wall mount, 24 v DC, operating current 40mA, Piezo Electric Type.
Supply and fixing of Battery 12V, 7AH
Supply and fixing Conventional Response Indicators 24 V DC
Supply and fixing 2 Core x 1.50 Sq mm sheathed cable with PVC insulated with multi strand heavy duty copper conductor cable.
Supply and fixing 19mm PVC conduit with accessories.
Supply and fixing Electric/Zone /Module unit cards
Glacier Cooling Solutions Private Limited
Power and Telecom Systems
devan enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .