Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.9 LAccepted-AOC B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | L1 | Accepted-AOC BEING A L1 BIDDER | |
| 2 | L2₹59.9 L+₹130 (<0.01%)Rejected-Finance | L2 | Rejected-Finance other than L1 bidder | |
| 3 | L3₹72.6 L+₹12.7 L (21.2%)Rejected-Finance | L3 | Rejected-Finance other than L1 bidder | |
| 4 | Rejected-Technical 283 ALIEN MARKET SADAR KABARI BAZAR MEERUT CANTT UP | - | Rejected-Technical not Approved due to adverse remark in HQ CECC WLR for QE Sep 2025 |
| Sl No | Description | Qty | Unit | BEHAL TRADERS L1 | sony engineering works L3 | JYOTI ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for Providing and injecting chemical Imidacloprid 30.5% SC emulsifiable concentrate for Post Constructional Anti termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. | 75 | Per Rm | 70 ₹5,250 | 140 ₹10,500 | 30 ₹2,250 Lowest |
| 2.00 | M & L for Anti termite Treatment of soil under existing floors using Imidacloprid 30.5% SC emulsifiable concentrate @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors all as specified . | 190 | Sqm | 80 ₹15,200 | 89 ₹16,910 | 30 ₹5,700 Lowest |
| 3.00 | Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for including cutting of reinforcement to facilitate demolition (Parapet wall) complete all as specified and directed. | 2 | Cum | 500 ₹1,000 | 600 ₹1,200 | 200 ₹400 Lowest |
| 4.00 | M&L for reinforced cement concrete 1:2:4 type B-1 using 20 mm graded aggregate (nominal mix ) in slabs supported on walls, beams and columns in floor, roofs, conopies, chajja and in shelves and the like. | 1 | Cum | 7,000 ₹7,000 | 4,900 ₹4,900 | 4,000 ₹4,000 Lowest |
| 5.00 | M&L for precast reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landing, cover slab etc set in cement mortar 1:4 complete all as specified and directed.
Note:- Reinforcement shall be measured and paid separately. | 1 | CUM | 7,000 ₹7,000 | 4,350 ₹4,350 | 4,000 ₹4,000 Lowest |
| 6.00 | S&F TMT bars 10 mm dia & over as in reinforcement of columns, beams, RCC, slabs, chajjas, lintels etc cut to length bent to shape required including cranking, bending, spirally hoping for columns, hooking ends and welding the new reinforcement with old steel bars complete. | 250 | Kg | 85 ₹21,250 | 95 ₹23,750 | 75 ₹18,750 Lowest |
| 7.00 | S&F 8mm dia TMT bars, cut to length bent to shape required including cranking bending spirally for hoping for columns, chajjas to parapets etc hooking ends and binding with mild steel wire not less than 0.90mm dia complete. | 40 | Kg | 90 ₹3,600 | 95 ₹3,800 | 80 ₹3,200 Lowest |
| 8.00 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pilasters, buttresses, etc.; vertical or to better, fair finishes.
Complete | 15 | Sqm | 300 ₹4,500 Lowest | 400 ₹6,000 | 300 ₹4,500 Lowest |
| 9.00 | M&L Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. | 8 | Sq.m | 300 ₹2,400 Lowest | 400 ₹3,200 | 300 ₹2,400 Lowest |
| 10.00 | M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 43 grade and two part of course sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guniting is done with polycretes admixture @ 2% by weight of cement all as per manufacturers instructions (polycretes admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. | 50 | Sqm | 800 ₹40,000 | 750 ₹37,500 | 500 ₹25,000 Lowest |
Tender Value
₹75.8 L
EMD Value
₹1.4 L
Closing Date
9 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NEW DELHI
HQ CWE NEW DELHI
SPL REPAIR TO BLDG NO P-58, 20 X STEWARDS QTRS INCL MISC CONNECTED WORKS AT ABHM UNDER GE NEW DELHI
2026_MES_748447_1
CWE-ND/62/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE NEW DELHI
₹1.4 L
20 Apr 2026
14 Jan 2026
11 Feb 2026
14 Jan 2026
9 Feb 2026
4 Feb 2026
M & L for Providing and injecting chemical Imidacloprid 30.5% SC emulsifiable concentrate for Post Constructional Anti termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.
M & L for Anti termite Treatment of soil under existing floors using Imidacloprid 30.5% SC emulsifiable concentrate @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors all as specified .
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for including cutting of reinforcement to facilitate demolition (Parapet wall) complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 using 20 mm graded aggregate (nominal mix ) in slabs supported on walls, beams and columns in floor, roofs, conopies, chajja and in shelves and the like.
M&L for precast reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landing, cover slab etc set in cement mortar 1:4 complete all as specified and directed. Note:- Reinforcement shall be measured and paid separately.
S&F TMT bars 10 mm dia & over as in reinforcement of columns, beams, RCC, slabs, chajjas, lintels etc cut to length bent to shape required including cranking, bending, spirally hoping for columns, hooking ends and welding the new reinforcement with old steel bars complete.
S&F 8mm dia TMT bars, cut to length bent to shape required including cranking bending spirally for hoping for columns, chajjas to parapets etc hooking ends and binding with mild steel wire not less than 0.90mm dia complete.
M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pilasters, buttresses, etc.; vertical or to better, fair finishes. Complete
M&L Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 43 grade and two part of course sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guniting is done with polycretes admixture @ 2% by weight of cement all as per manufacturers instructions (polycretes admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M& L for fixing rebar of required length & diameter for structural connection in RCC slab, Beams and similar situations including power drilling holes of appropriate diameters in reinforced or plain concrete upto depth minimum 100 mm or as per manufacturers specification, fixing the reinforcement in position using epoxy Arcylate based anchoring adhesive at all heights and levels, 16 mm dia hole suitable for inserting 12 mm dia reinforcement bars all as specified & directed.
M& L for fixing rebar of required length & diameter for structural connection in RCC slab, Beams and similar situations including power drilling holes of appropriate diameters in reinforced or plain concrete upto depth minimum 100 mm or as per manufacturers specification, fixing the reinforcement in position using epoxy Arcylate based anchoring adhesive at all heights and levels, 14 mm dia hole suitable for inserting 10 mm dia reinforcement bars all as specified & directed.
S&F TMT bars 5 mm dia upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with with mild steel wire (annealed) not less than 0.9mm dia or securing with clips including U-shaped stirrups with necessary welding required at site and all as directed by Engr-in-Charge.
M&L for followings :- (i) Removing plaster & finishes all around the columns, slabs & beams (on all visible side of column, beams, lintel etc to full height to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. Supply & applying of rust removing chemical to remove rust from existing reinforcements. (The Engr-in-charge may order sand blasting if rust is visible) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for Providing & Pouring Micro concreting M-40 grade :- (I) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed including M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strata surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairly rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer complete all as specified and directed.
Expose the first joint of masonry structure at ground level horizontally. The plaster must be knocked off at least 50 cm beyond the visibly penetrated area. Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. Drilling Holes: Drilling holes 10mm diameter in masonry structure along the side of the joint as per manufacturer's instructions so as to cross the brick/block at the intervals spacing of 15-30cm depending on extent of rising dampness as per recommendation of engineer in charge. Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. Install latex polymer packer injection packers 9.8mm diameter, 10cm long in the holes and tighten. Fix the packer securely using sealant. Cutting of Packers: Cut the packers after completion of grouting without damaging structural elements.
Supply and apply of a 3 part, very low viscous, elastic polyacrylic injection resin with a versatile and adjustable reaction time having Mixed viscosity : 3-11 M.pa.s at +20 Deg C, Reaction time : adjustable according to ambient temperature and execution requirement between 8-50 mins, pH – 9-10, tested as per Wissbau No. 2002-094-(1A) – Function test with re-injectible hose system. The holes should be drilled until a depth of approx 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump injection of polymer resin compound at >20 bar into or behind fissures or into masonry joint which are allowing water to infiltrate into unwanted areas. If voids in masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout. When movement stops or polymer compound appears at the packer move to the next packer and inject. If the dampness is heavy, inject similarly at next joint line. Chemical use Fosroc or equivalent.
Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars, etc, built in cement mortar complete all as specified and directed.
M&L Brick work with sub class "B" bricks , straight or curved on plan exc 6 m mean radius built in cement mortar (1:6),(up to two story Bldg) complete all as specified.
M&L Brick work with sub class "B" bricks , straight or curved on in half brick thick wall built in cement mortar (1:4),(up to two story bldgs.) complete all as specified.
M & L for dismantling of any type of roof tile with old app or any type of roof treatment on roof surface laid bedded and pointed in any mortar
M & L for Demolition of mud in roof, any thickness, including plastering and leaping upto two storey bldg incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as directed by Engr in charge and specified.
M&L for cement concrete 1:2:4 type B0 (using 12.50 mm graded stone aggregate) as in levelling coarse over RCC slab to bring the desired slope up to forustoried Bldg, using water proofing compound as per manufacturer instruction complete all as specified & directed. Note:- Water proofing compound shall be measured and paid separately.
Supply only integral water proofing admixture of approved quality.
M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm over 15 mm thick screed bed in cement mortar 1:4 on roof surface or concrete surfaces, finished even and smooth (without using extra cement) mixed with WPC and paste the membrane with torching method complete all as specefied and directed NOte : WPC shall be measured and paid separately
S & F for PCC roof Tiles (250 mm x 250 mm x 25 mm) on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with Fixit Epoxy Tile Grout (Make Dr fixit 404 fevimate TG or equivelent ), including rubbing and polishing of the surface complete, including providing skirting up to 250 mm height along the parapet walls in the same manner all as directed
M & L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete as directed.
Demolition of stone slab and tiles of any description or thickness on steps, jambs, pillars, walls, cooking platform, floors, aprons, skirting etc laid bedded and pointed in any mortar complete all as specified and directed
M&L for colour marble work (greeen) 18mm thick (table rubbed and polished) in steps, riser, jambs, pillars, window cills, and like including including 20mm thick screed bed in CM 1:6 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including rounded edges with shade of Udaipur green complete all as specified and directed.
Same as item No 30 but in vertical surface, skirting, with 12mm thick plaster as backcoat in cement mortar (1:3) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding upto bricks or concrete exposed surface (but not backing) laid bedded and jointed in any mortar and removal of old tiles from premises complete all as specified and directed.
M&L for super gloss vetrified floor tiles of size (600mm X 1200x8-9mm), in floors etc. set and jointed over screed, plaster or RCC surface, using a cement based Polymer modified tile adhesive conforming to IS 15477:2019 type 1 & EN 12004 C1T with green pro certificate. The adhesive shall be sourced from an approved manufacturer with in-house production facilities and ISO certification. The adhesive to be mixed thoroughly and applied with a bed thickness ranging from 3 mm to 12 mm, evenly spread & combed using notched trowel and gently press using rubber mallet. Tiles shall be gently pressed into place using a rubber mallet, maintaining a uniform joint spacing as directed by engr-in-charge , followed by grouting using epoxy quartz technology-based grout to ensure a durable, stain-resistant, and aesthetically finished surface. (Screed bed shall be measured and paid separately)
All same as per item Sl No 33 above but as in skirting/dado etc over and including renderning 10 mm thick cement mortar 1:4 complete all as specified. (Note : skirting shall be flashed with the wall surface)
All same as item No 33 but for 600x600 mm matt finished ceramic tiles in floors etc complete all as specified and directed..
M&L for 15mm thick screed bed in CM 1:6 complete all as specified and directed..
M&L for decorative digital design glazed coloured walls tiles of size 600x1200x8-9mm mm thick, for works on vertical surfaces such as skirting/dados of 1st quality over screed, plaster or RCC surface, using a cement based Polymer modified tile adhesive conforming to IS 15477:2019 type 1 & EN 12004 C1T with green pro certificate. The adhesive shall be sourced from an approved manufacturer with in-house production facilities and ISO certification. The adhesive to be mixed thoroughly and applied with a bed thickness ranging from 3 mm to 12 mm, evenly spread & combed using notched trowel and gently press using rubber mallet. Tiles shall be gently pressed into place using a rubber mallet, maintaining a uniform joint spacing as directed by engr-in-charge , followed by grouting using epoxy quartz technology-based grout to ensure a durable, stain-resistant, and aesthetically finished surface Note : Plaster as backing coat shall be measured and paid separately
S&F in repair vitreous china wash down water closet (EWC) white complete with provision of lime concrete bed incl valveless syphonic action type PVC low level flushing dual action ( 2 ltrs and 7-8 ltrs ) cistern with inlet ball valve float & handle incl. brackets of 10 ltrs capacity complete with plastic water closet seat white closed pattern with flat bottom & cover & mild steel chromium plated or aluminium hinges device & flush pipe of polythene of low or high density of PVC 32mm dia for low level PVC cistern.
S&F ABS chromium plated Health Faucet including flexible pipe of 15 mm bore and 1.20M long with and including 15 mm bore complete all as specified and directed.
S & F in repair Vitreous China counter type Wash Basin of size (approx 490 x 380 x 175 mm) including necessary waste pipe and push type coupling, brackets and cutting for and pinning in ends of brackets, complete.
M&L for PVC mirror cabinet of size 330 mm x 430 mm with openable single looking mirror with PVC inner & outer shelves of any colour, including taking down old looking mirror & wooden cupboard mirror complete (fixed in repairs) all as specified and directed.
S&F as in repair chromium plated shower rose of size 125 x 125 mm square (ABS Chrome plated with rub it cleaning system) with or without swivel joints any type including chromium plated shower arms length 200mm fixing to steel pipe and union completed.
S&F in repair fancy type glass corner 300mm radius of 10mm thick toughened glass with CP railing fixed with screws fancy type complete all as specified .
S&F Brass chromium plated wash hand basin mixer suitable for counter type WHB, fancy type, for mixing hot & cold water, single hole, screwed down for iron pipe, bore of pipe 15mm, complete all as specified & directed.
S& F 15 mm bore 2-in-1 (shower and spout) brass CP wall mixer for mixing hot & cold water with shower band pipe screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair brass chromium plated angle valve with cup suitable for 15mm bore pipe, complete all as specified
S&F brass chromium plated towel rail 20mm dia D type 60cm long between flanges of brass chromium plated all as specified
S&F in repair fancy type stainless steel towel ring
S&F in repairs Good quality Connection pipe (PVC) 15 mm dia and 450/600mm long complete all as specified.
Dismantling of floor of size not exceeding 1.50 Sqm mtr for EWC water closet and removing out the cinder/concrete from sunken portion, , grinding any sharp edges etc all as specified and directed with following: (a) Cleaning of RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc. (b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite. (c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified. (d) M&L for providing 40 mm dia GI pipe spout projecting at least 150 mm beyond outer face of wall. (e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed. (f) The area of Each WC portion is n.exc 1.50 Sqm each. (g) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account. (h) Same treatment shall be done all around of sunken on vertical surface upto 250mm (j) 72 hrs Ponding test shall be carried out for sunken treatment before payment.
Taking down (Door) chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete.
Taking down (Door) chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4.00 Sqm each (without taking off shutters from the frames) complete.
S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkhat of size 65x 125 mm of double rebates comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and non toxic additives ( max toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge. Note: For WPC solid door/windows frames, minus 5mm tolerance in dimension i.e. depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and factory paste WPC/PVC lipping of min 1.2mm thick and wide as thick of shuttrs shall be provide at edge of shutter/door and similar with bonding adhesive as per manufacturer's direction and edge shall be moulding as per direction of Engr in charge and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineering- Charge. (Note: stainless steel butt hinges shall be paid separately under relevant item).
Providing 30mm thick FACTORY-MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of Density 650 Kg /cum Manufactured by an ISO-9001-2015 certified Company, Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (Confirming as per IS:4020). WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and factory paste. The door should be water proof, termite proof, fire retardant and having screw holding capacity and factory paste WPC/PVC lipping of min 1.2mm thick and wide as thick of shuttrs shall be provide at edge of shutter/door and similar with bonding adhesive as per manufacturer's direction and edge shall be moulding as per direction of Engr in charge. Door to be fixed to frame with 3 nos. SS butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through Other hardware should be fixed with 19*6mm size steel screws etc. Complete as per direction of Engineer-in-charge, manufacturer's specification & drawings.” Note: Fixture/fittings shall be measured & paid under relevant item
S&F aluminium window as per TD drg No. CEDZ/TD-316 with following specifications :- (i) Outer frame of size 40mmx114mm with 1.1mm thickness, corner 45 degree cut & aluminium welded. (ii) Center mullion of size 40mmx65mm. (i) Welded shutter (02 Nos) of size 40mmx60mmx1.1mm thickness 45 degree cut mechanically joint with 6mm allen key bolt clamp with 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock, aluminium kobra hinges 2 Nos per shutter. (iv) 12mm SS 202 grade round bar safety grill at 100mm cc distance modified to 150mm cc distance in front of handle, welded at both ends with 6mm SS 202 grade round bar. (v) Welded wiremesh shutter (2 Nos) of size 40mmx18mmx1.1mm thickness 45 degree cut with 0.45mm nominal dia of SS wire mesh, SS 75mm long hinges & PVC magnet. (vi) Entire window shall be powder coated with pure polyster coat of any shade as approved by GE. (vii) Windwo shall have provision for installation of window AC/Desert Cooler and provision of windwo glass shutter, wiremesh, grill and necessary fittings and locking arrangements for subject portion will be modified as per ground requirement during the execution as per directions of Engr-in-charge. (viii) Window shall be installed with silicone, complete all as specified and directed by Engr-in-charge.
Dismantling wrought iron or mild steel/ iron work of any description (steel window & Grill) complete all as specified and directed.
M & L for Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, welded or forged into spikes, framed guard bars, window frames, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work fixed in position including holdfasts or screws confirming to Fe.290.Gde-E-165 complete all as specified.
S& F Square Spot Welding M S Jali of Mesh size 30x30mm and 2.6 mm dia fix to ms frame all as specefied and directed
M&L providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement
S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putty / rubber beading as in aluminium door / window shutter, in square n exc 0.5 Sqm in each pane.
S&F stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed tinned tacks or galvanised wire staples .
M & L for preparation of new Steel surfaces of any description not otherwise described over 10 cms width or girth and apply two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer all as specified.
M & L for preparation of old Steel surfaces of any description not otherwise described over 10 cms width or girth and apply one coats of synthetic enamel paint all as specified.
S&F 150mm long (size) butt hinges, stainless steel AISI 304 grade with brass/bronze hinge pin complete
S&F 100mm long (size) butt hinges, stainless steel AISI 304 grade with brass/bronze hinge pin complete
S&F 75 mm long L Bihari concealed type auto closing hinges incl stainless screw, complete all as specified & directed.
S&F stainless steel AISI 304 grade barrel tower bolt 100mm long, extruded section, etc. complete all as specified and directed.
S&F stainless steel AISI 304 grade barrel tower bolt 200mm long, extruded section, etc. complete all as specified and directed.
S & F 30mm matalic Multipurpose Furniture Lock with duel keys for Drawers and Cabinets, Safety Lock for Wardrobe, , fixed ss with screws complete.
S&F 200mm long, stainless steel , sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, and fixing bolts and sliding bolts and fixed with locking arrangement , complete all as specified.
S&F Stainless steel 150mm long extruded fancy D' type type SS handle for door fixed with nuts , screw and washer complete all as specified.
S&F heavy duty door magnet stopper is constructed of high quality virgin plastic, solid, sturdy and rust-Proof for hold and clatch fixing to back side of door shutter including all fixing items complete all as specified and directed.’ Make Godrej, Link, Dorset, KAFF’
S&F 100mm long extruded fancy D' type type SS handle for kitchen cup boards shutters, pvc door fixed with nuts , screw and washer complete all as specified.
S&F 150 mm ordinary helical door springs incl roller & roller plate complete of mild steel.
Demolition of cement concrete unreinforced of any description and in any position not other wise specifically provided as in drain copings and similar situations incl removing the unserviceable material out side the MOD land complete all as specified & directed.
M&L cement concrete 1:4:8 type D-2 (40mm graded stone aggregate) as in sub base , and mass concrete complete all as specified.
Cement concrete 40mm thick type B-1, 1:2:4 (using 20mm graded stone aggregate) in floors pavings etc finished even & smooth with out using extra cement.
M & L for Cement concrete 1:3:6 type C1 using 20mm graded stone aggregate in plinth protection, 75mm thick, finished fair and even without using extra cement, complete.
Taking up or down 15 mm bore GI tubing and connections including cleaning for re-fixing complete all as specified and directed.
-Ditto- as per item No 81 above here-in-before but for 20mm dia.
-Ditto- as per item No 81 above here-in-before but for 40/50mm dia.
Supplying and laying of CPVC 20mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl brass coupling fittings complete all as specified complete with fitting as required.
Supplying and laying of CPVC 25 mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl brass coupling fittings complete all as specified complete with fitting as required.
Supplying and laying of CPVC 32 mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl brass coupling fittings complete all as specified complete with fitting as required.
M&L for cutting chases on brick or concrete surface for concealed water tubing or girth n.exc 10cm including making good of disturved surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed.
Dismantling water tanks of capacity exceeding500 litres but not exceeding 1000 litres complete.
S&F 1000 ltr capacity rotational moulded four layered polyethylene water storage tanks (cylindrical vertical with closed top) white colour hoisted and fixed in position all as specified.
As per item no 92 above but except water tank incl making connection with fitting for inlet & outlet pipe.
S&F in repair PTMT ball valves high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20mm dia.
Dismantling of cast iron pipe of any dia (soil/waste/vent) with fittings etc fixed to walls, ceiling, on floors & from trenches if required including taking out any type of joints complete all as specified.
S & F PVC (SWR) pipes single socketed, 110 mm bore in any length with rubber ring joints including bend, 'L', Tee,branch pipe, Y etc, stack clamps fixed to walls/floors (Note Bldg G+1 and 20 Nos toilet cum bath)
S & F PVC (SWR) pipes single socketed, 75 mm bore in any length with rubber ring joints, including bend, 'L', Tee,branch pipe, Y etc, stack clamps fixed to walls/floors (Note Bldg G+1 and 20 Nos toilet cum bath)
S&F in repair 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair Salt Glazed Stone Ware (SGSW) gully traps square or round mouthed type size 125x100mm including excavation/earth work, bed concrete, surrounding concrete and CI grating, complete all as specified.
Taking down cement plaster from brick or concrete surface incl racking out joints hacking for key and scrubbing down with water complete including removal of rubbish off the premises, complete all as specified and directed.
M&L for readymix plaster 15mm thick on brick or concrete surfaces of walls, chajja, balconies,beams , columns, manholes etc and similar work finished even & smooth without using extra cement including necessary scaffolding, form work, safety precuation for multi storey of bldgs complete all as specified & directed.
M&L for preparation of brick or concrete surface clean and free of dust, oil, paint, loose particles, demolding agents, organic products etc and applying 15mm thick exter surface treatment as in two layers (15mm base layers and 5mm final layer) as under :- (a) Base coat (15mm thick) : Apply in two or more coats to achieve average 15mm thick of water vapour permeable mortar, UNOFIN CLASSIC basecoat Render or equivalent brand of Make Sika, Fosroc for weather resistant & high performance façades with CSIV compressive strength, Flexural Strength ≥ 2.5 N/mm2 and water vapour permeability ≤μ15 as per EN 998-1 and finished even & rough marks to anchore with final layer. It should be includes the reinforcement of weaker points/areas (change in the substrate material, slabs, pillars, roller blind boxes, around the openings/windows, doors, etc.), with fibreglass mesh to avoid cracks as per manufacturer’s recommendations or as per direction of Engr in Charge (b) Final layer (5mm thick) Finishing with the rainwater resistant and water vapour permeable rendering mortar, UNOFIN PRIME COARSE Render or equivalent brand of Make Sika, Fosroc, applied in two or more coats to achieve 5mm thick for rainproof/weather resistant & decorative facades with a CSII Compressive Strength class, Flexural Strength ≥ 2.5 N/mm2, resistance to water absorption as W2 (C ≤ 0.2 Kg/m2. min0.5), water vapour permeability ≤μ15 as per EN 998-1 all as per manufacturer's recommendations and finished even and smooth all as per specification and direction Note : 1. Size and specification of fiberglass mess shall be as per manufacturer's recommendations 2. Contractor shall be provide authorised applicatore and no exter cost shall be provided in this account 3. work shall be executed up to three storey bldgs. 4. Including steel scaffolding and safety 5. Cost of above mentioned shall also included in quoted rates.
M&L for preparation of old distempered surfaces of wall by complete removal of existing treatment from wall surfaces and applying two coats of distemper oil emulssion, white or tinted over one coat of primer and 1.5mm thick wall care putty all as specified & directed.
M&L for preparation of new plastered wall surfaces and applying two coats of distemper oil emulssion, white or tinted over one coat of primer including 1.5mm thick wall care putty complete all as specified & directed. .
M&L for preparation of old distempered surfaces by complete removal of existing treatment from ceiling surfaces and applying two of distemper oil emulssion, white or tinted over a coat of primer paint over wall care putty min 1mm thick compete all as specified & directed.
M&L for preparation of new plastered ceiling surfaces and applying two coats of distemper oil emulsion white/tinted over one coat of primer over wall care putty min 1mm thick complete all as specified & directed.
Note : (a) All work shall be done mechanically through authorised applicator only. (b) Authorised applicator of paint manufactures shall have valid authorisation letter from the manufacturer (minimun regional HQs) issued not earlier than 30 days days from start date of the said finishing work.(c) The contractor shall provide application,testing and certification of finishes by paint manufacturing firms/their authorised applicators.(d) Cost of above mentioned shall also included in quoted rates.
S&F structural mild steel work as in roof trusses, rafter, purlins, crane gantries, rails and fastenings and heavy bracket framingetc (beam, tee, angle, channel or flat section) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet with approved profile and 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engr-in-Charge.
S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Plain Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with density not less than 650 kg/cbm Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free. Water/ Moisture Proof, Fire Retardant and fixing with stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen & Cabinets.
S&F High Gloss Finish Liner Laminate /High-Pressure Laminate (HPL) Sunmica of 1.0 mm thick of multi colour/design as approved by GE to be fixed to wpc/wood/plywood surface with preparation of new surface and apply best adhesive for pasting as per manufacture instruction all as specified and directed
S&F factory past WPC/PVC lipping of min 1.2mm thick shall be at edge of shutter and similar with bonding adhesive as per manufacturer's direction and edge shall be moulding as per direction of Engr in charge
M&L for Solid PVC Door frame of size 50 mm x 95 mm made out of 5 mm single side prelam PVC sheet reinforced with M.S tube supplying and fixing in opening as per specification and drawing.
S&F for factory made solid PVC moulded door shutters (with particle board core), 28 to 30mm thick (Stiles) with 2, 4, or 6 raised panel (as ordered) design with 2mm thick moulded prelam PVC sheet on the front face and 2mm prelam PVC sheet on back face, supply and fixing in frame at site as per the specification and drawing.
S&F for 20mm thick CNC Cut WPC jali with MS frame of 25x25x1.5mm with two coat of glossy deco paint for Plumbing Duct Cover, Shaft Cover, For Exterior use to provide solutions for exterior facade and elevational treatment for the building with waterproof, rusting proof with pigmented nature helps the color, unbreakabe including all fiting and fixing arrangement. The design and shape shall be porvided as per approved by Engineer in Charge and fixed with all as specefied and directed Note : MS frame shall be measured and paid separately
S&F in repair stainless steel drapery curtain rods gold or antique silver 25mm nominal dia and minimum wall thickness 1.20mm of SS-304 grade of approved brackets design as approved fixed in brick/ concrete wall with same finished knobs/latto on each end of curtain rod including taking down old pelmet, complete all as specified and directed.
S&F WPC Fluted Wall/ceiling panel of sise 125x 25mm square and 3mm thick holow tongue and grove type of multi colour as directed by GE for commercial uses panel suitably placed in wall/ceiling with louver cladding clips GI Galvanized Iron Steel clamp buckle interlocking Hanging Bracket Silverss@ specing 300mm c/c fixed to wall/celing with ss screw and plug complete all as specified and as directed
M&L for 2nd class soft Wood plain fillets, square, rectangular or triangular in section, secured with nails cross sectional area exc 35 sqcm but not exc 50 Sqcm on surfaces of any description wall or ceiling or any frame , width or girth complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m deep for foundation and getting out in soft/loose soil all as directed and specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25 cm soft/ loose soil all as directed and specified.
Removing excavated materials n exc 50 m and depositing where directed at a level n exc 1.50 mtr above the starting point all as directed.
Demolition and breaking up drain pipes salt glazed stone ware pipes 150 mm dia (internal) set in cement mortar.
Material and labour HDPE Black DWC Sewerage and Drainage Pipe 150 mm dia in trenches and jointed with using rubber gasket and pipe joint lubricant for both end and 150 to 200 mmd wide color joint socket shall be provided to cover the joint all around as per specification and manufacture instruction all as directed and specified.
M&L PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified and as directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete PU coating and glossy finished paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand including demolition/dismanlting complete.
M&L for precast reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in cover slab etc including necessary form work, set in cement mortar 1:4 complete all as specified and directed.
M&L for cement concrete chequered tiles 300X300X25 mm thick PU qtoted (glazed finish) with grey cement with pigment, set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces as in floors over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
TO CARRY OUT THIRD PARTY AUDIT OF THE ACCN UNDER CONSTRUCTION AS PER THE SCOPE ELABORATED BELOW:- (a) Seepage intrusion Assessment though inspection and thermal Imaging technology of 20 Nos Single living stewards accn including att toilet entry passage and verandah or balconies, mumty, staircase along with stepwise solution recommendations through a report. (b) Scope of work :- (i) To identify the source of leakage, seepage/dampness in the structure through concealed/open pipes of sanitary, plumbing and water supply already laid in the structure. (ii) To identify the source of seepage / dampness in the structure through masonry joints in the structure. (iii) To identify the source of seepage / dampness in the structure through joints of tiles laid in floor/ wall in the structure. (iv) To identify the presence of dampness/ moisture in shaft area adjacent to sanitary pipe stacks. (v) To check the alignment of all sanitary, plumbing and water supply pipe lines. To check the firm tightness of the joints in pipe lines of sanitary, plumbing and water supply lines. (vi) To check the slope provided in the sanitary/ plumbing lines. (vii) To check the proper sealing/ jointing of traps and pipe connection. (viii) To check the leakage through joints of water supply lines/ fittings. (ix) To check the proper sealing/jointing of traps and pipe connection. (x) To check the leakage through joints of water supply lines/ fittings. (xi) To check the leakage through joints of wall mixture, stop cock, angle valve, shower arms, bib cocks and other plumbing fittings. (xii) A detailed report of cause/source of leakage, seepage/ dampness in the structure and its rectification shall be carried out by the competent technical expertee for nature of work required. (xiii) In addition to visual inspection latest equipment available in the market/ field of engineering IR/ thermal camera, moisture meter, borescope, inspection mirror, digital meter, pressure pump, air pressure garge etc. for detection/ finding the sources of leakage/ seepage through concealed pipes and its joint shall be used. Contd/-.........
Note : - (a) The work shall be carried out by the agency having ISO certified company, Member of Home Inspection Association of India and having similar nature of work experience for minimum 15 years or specialised in the nature of work. (b) A detailed report shall be prepared and submitted for the cause of leakage/ seepage and nature of repair work remedial action carried out to arrest such leakage/ seepage. (c) Coloured photographs shall be submitted for all location of leakage/ seepage. (d) The inspection is carried out physically in minimum three time ie before commencement, during execution (after laying of GI/CI pipe and before PCC or coverup) and after completion of the work. (e) Mod of payment (i) Ph-I - 80% of the payment will be released after checking result of suggested rectification after submission of report as per included items related to block. (ii) Ph-II – Balance 20% of the payment will be release after physical checking of one months of the physical completion of the work
Taking down carefully old point wiring with aluminium/ copper conductor (Light / Fan/ Socket/ power Point ) complete including fixture and fittings such as switches, light fittings,ceiling rose, pendent holders, bell, regulators and socket,light fittings etc .removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surface & wall/ floor complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed multi stranded FRLSH type copper conductor cable of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded FRLSH type copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly in and including PVC concealed conduit 25 mm dia medium grade ISI marked and its accessories including provn of new factory made pressed steel modular switch/terminal box of suitable size and new modular front & back plates of approved colour/model of suitable size for housing the modular switches, sockets, fan regulators for the following :- NOTE : minimum thickness of the MS sheet of sunken box should be 1mm . Make of wire Polycab ,RR kabel ,Finolex.
One light/fan point controlled by one no, one way 5 Amp switch.
One light point controlled by two nos, two way 6 Amp switches.
One bell/buzzer point controlled by one bell push button.
One three pin socket outlet 5 amps point controlled by one no, one way switch on independent board.
One three pin 5 Amp socket outlet point controlled by one no, one way switch on same board.
All as per item No. 2 here in before but with 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 amp socket out let point on independent board.
Note for item No 2 & 3:- (i) Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate.
(ii) No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required.
(iii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion.
S&F modular switch 230/250 volts grade one way (as catered in point wiring above) of following rating :-
One way 6 Amp one module rating IP 20
Modular Bell push switch 6 Amp . 1 module rating IP 20
One way 16 Amp one module rating IP 20
All as per item No. 4 here in before but 2 way 6 Amp IP 20 rating.
S&F modular socket out let shuttered type flush mounting type, 230/250 volts grade (as catered in point wiring above) of following ratings:-
2/3 Pin 6 Amp combined 2 module type IP 20 rating.
2/3 Pin 16 Amp combined 2 module type IP 20 rating.
Supply & fix Call bell ding dong AC 230 volt single pole complete all as specified.
Supply and fixing of Modular MCB SP 16 Amps 240V 3 KA, C Curve, fitted in main switch board, including 2.5 sqmm wire connecting power socket & modular MCB complete all as secified and directed by Engr-In-Charge incl taking out sheet metal enclosure.
Supply and fixing in replacement of factory made SPN DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way SPN 220 Volts, with suitable busbar, neutral link & earth link suitable for complete all as specified.
Supply and fix in replacement of factory made VTPN DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TPN as incomer & MCB SP/SPN as out going complete all as specified & directed Note:- Cost of MCCB 4 pole 100 Amp , breaking capacity 25 KA is included in unit rate quoted by contractor.
S&F in replacement of MCBs, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) :-
Note : Make of the MCB should be the same as that of DB
MCB SP 6 to 32 Amps.
MCB DP 32 Amps.
S&F in replacement of LED Tube light of 20 watt 230 volt (approx size 4 ft) box type complete with LED tube light 20 watt & all accessories internally prewired including connecting up with three core sheathed flexible copper conductor cable of suitable size having min P.F>0.95, minimum efficacy 120 lumen/watt IP 20 rating complete all as specified.
S&F in replacement of wall mounted LED light bulkhead type 6-7 Watt, complete all as specified and directed.
Supply and fix sensor based LED building security light fitting 90 Watt 230 V AC outdoor type with excellent thermally managed pressure die cast aluminium housing, integrated PC Lens, LM 80 Certified LED, External photo sensor for automatic on/off, sensor mounting backside the luminaries and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete all specified and as directed.
Taking down/ dismantelling ceiling fan,size 1200mm including fan blade complete and deposit to MES store in safe custody.
Supply and fixing remote controlled BLDC ceiling fan 1200 mm sweep, with remote, having minimum CMM 215 and RPM 340, operating at 230 volts, 50Hz, having full copper motor & powder coated ribbed aluminium blades for higher air delivery, longer life complete with all the accessories including making arrangements to hanging of fan to ceiling with proper hook, nut,bolts & remote stand complete all as specified & directed by Engineer-in-charge. Note:- The ceiling fan with complete accessories to be safely deposited to MES store yard.
Supply and fix Exhaust fan AC single phase 230/240 v of size 250 mm sweep, with minimum CMH-800, 1200 RPM Engineering thermoplastic body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including hole making, Louver complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of UNSV Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:-2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
M & L for replacement of unsv plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc.
S&F in replacement aesthetically designed Wall mounted decorative wall LED light of 15 W fixture with opal diffuser to give glare free light including suitable LED lamp of 15 W, complete all as specified & directed.
M & L Sub main wiring with two single core 1.5 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 1.5 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:-2(two) Runs of 1.5 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 1.5 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
S&F ceiling rose 3 terminal / PVC insulated body ISI Marked all as specified.
Supply and fixing electric water heater of capacity 25 litre, BEE 5 Star rated heating element upto 2 KW with glass line inner tank with whirlflow technology , Mg anode rod, IPX4 high strength polymer body complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. Note:-1. The contractor needs to submit manufacturing warranty of geyser of minium two years to Engr-in-charge.
Supply and fixing in replacement of LED DOWNLIGHTER CIRCULAR TYPE 10 WATT , 220V AC decorative box type with driver, holder including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-charge.
stage.html
html • 0.05 MB
techsummary_838179.pdf
BOQ Comparative Chart
xlsx
finsummary_838179.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
tender62upl.pdf
Tender Documents • 1.79 MB
BOQ_838179.xls
BOQ • 5.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .