Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.1 L+₹1.4 L (5.59%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | SenthooranP L1 | C SATHIYASEELAN L2 |
|---|---|---|---|---|---|
| 1.01 | Dismantling the Existing Buiding All round Brick Masonry in cement mortar walls under 3m high | 18 | m³ | 282.9 ₹5,093.33 Lowest | 298.7 ₹5,377.79 |
| 2.01 | Dismantling the Existing Roof Slab RCC by manual / by using deploying machineries | 4 | m³ | 4,304.4 ₹17,200.38 Lowest | 4,545.4 ₹18,163.42 |
| 3.01 | Charges for putting bore hole of size 23 cm of pile foundation up to hard stage of sand clay other bulb rate to fix all labour charges for boxing hire charges for boring set and all other T&P employed etc, complete. | 18 | m | 398.2 ₹7,167.6 Lowest | 420.5 ₹7,569 |
| 4.01 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete | 41 | m³ | 258.6 ₹10,601.45 Lowest | 273.1 ₹11,195.88 |
| 5.01 | Supplying and filling in foundation and basement with filling Quarry Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification. | 4 | m³ | 418.5 ₹1,675.23 Lowest | 441.9 ₹1,768.9 |
| 6.01 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification | 10 | m³ | 5,669.5 ₹56,716.15 Lowest | 5,987 ₹59,892.33 |
| 7.01 | Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. | 64 | m³ | 415.1 ₹26,568.05 Lowest | 438.3 ₹28,052.94 |
| 8.01 | Supplying, erecting with necessary supports for plain surface such as RCC Boxing side slab and silmilar RCC slab with all cross bracing etc., complete in all floors of any height ( the retrived materials ) should be taken back by the contractor the payment for cenetering shall be given after the concrete is laid ( For Rectangular or | 92 | m² | 1,387.8 ₹1,27,677.6 Lowest | 1,465.5 ₹1,34,826 |
| 9.01 | Supplying, erecting STEEL CENTERING for sides and soffits inc supports and strutting for plain surface such an reinforced cement concrete slasp rectangualar beams tee or el beams lintels , bed blocks staircase in all floors of any height (the retrived materials should be taken back by the contractor) the payment for cenetering shall be given by the concrete is laid ( RCC column footing plinth, beam and lintel sides ) | 95 | m² | 1,123 ₹1,06,685 Lowest | 1,185.9 ₹1,12,660.5 |
| 10.01 | Supplying, erecting STEEL CENTERING for sides and soffits inc supports and strutting for plain surface such an reinforced cement concrete slasp rectangualar beams tee or el beams lintels , bed blocks staircase in all floors of any height (the retrived materials should be taken back by the contractor) the payment for cenetering shall be given by the concrete is laid (bottom only) | 65 | m² | 1,156.6 ₹75,174.95 Lowest | 1,221.4 ₹79,386.73 |
Tender Value
₹25.7 L
EMD Value
₹25,689
Closing Date
25 Aug 2025, 3:00 pmClosed
The Commissioner Madurai Corporation
Aringar Anna Maligai, Thallakulam, Madurai.
Construction of new community hall building at AD colony in ward 45
2025_MAWS_592105_1
E7 / EST. 114 / 25-26 (MLA-S)
Open Tender
Civil Works
Lump-sum
Madurai
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹25,689
11 Sept 2025
13 Aug 2025
25 Aug 2025
13 Aug 2025
25 Aug 2025
13 Aug 2025
Amount
Dismantling the Existing Buiding All round Brick Masonry in cement mortar walls under 3m high
Dismantling the Existing Roof Slab RCC by manual / by using deploying machineries
Charges for putting bore hole of size 23 cm of pile foundation up to hard stage of sand clay other bulb rate to fix all labour charges for boxing hire charges for boring set and all other T&P employed etc, complete.
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete
Supplying and filling in foundation and basement with filling Quarry Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Supplying, erecting with necessary supports for plain surface such as RCC Boxing side slab and silmilar RCC slab with all cross bracing etc., complete in all floors of any height ( the retrived materials ) should be taken back by the contractor the payment for cenetering shall be given after the concrete is laid ( For Rectangular or
Supplying, erecting STEEL CENTERING for sides and soffits inc supports and strutting for plain surface such an reinforced cement concrete slasp rectangualar beams tee or el beams lintels , bed blocks staircase in all floors of any height (the retrived materials should be taken back by the contractor) the payment for cenetering shall be given by the concrete is laid ( RCC column footing plinth, beam and lintel sides )
Supplying, erecting STEEL CENTERING for sides and soffits inc supports and strutting for plain surface such an reinforced cement concrete slasp rectangualar beams tee or el beams lintels , bed blocks staircase in all floors of any height (the retrived materials should be taken back by the contractor) the payment for cenetering shall be given by the concrete is laid (bottom only)
Reinforced Cement concrete 1:1.5 :3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete. For Basement Floor
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 83/4"X41/4"X 21/4" including finishing, curing, etc., complete complying with standard specification - 100CFT For Basement Floor
Plastering with cement mortar 1:3, 10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Supply andand Delivery Fabrication of MS doors and windows with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangemets using 20mm squre MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles,plates,sheets,fabrication charges, cost of hold fast and transportation charges etc.,complete Fully Panelled Double Leaf-Door Size- (1.00m x 2.10 m)
Toilet Fully panelled Single leaf - Door (0.75 m x 2.10 m)
Ventilator (0.45 x 0.60m)
Fully panelled Double leaf - Window (without Ventilator) (1.20m x 0.90 m)
Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch and making good of the concealed portion with suitable colour for PVC concealed light / Fan Point (For electronic regulator) (5 Points Per Coil) SD -
Supply and fixing of single box type (philips / Havells / Eq) suitable for 4 feet 20W LED tube light with TW round blocks on wall or ceiling with 20W LED tube light with PVC unsheathed Copper leads from terminals to
Supply and fixing of 1200mm (48") sweep AC ceiling fan (Crompton / Havells / Usha / Equivalent) with 2 module 100W regulator complete with 300mm down rod on existing clamp SD 111
Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40 A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (lik
Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete SD 131
White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. - 100sq.m S.I.333
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
Painting with Ready Mixed Enamel Paint over the new Iron works of approved quality and colour with priming coat including the cost all materials etc., complete, in all floors.
Add GST 18%
C SATHIYASEELAN (BID ID -1438223)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .