Loading…
Loading…
Tender Value
₹2.6 Cr
EMD Value
₹2.8 L
Closing Date
18 Mar 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any work of Signal or Telecom involving trenching, laying & testing of Signal or Telecom cables OR Any other miscellaneous outdoor S&T work.
9 conditions · 2 needing a document upload
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V & Annexure- V(A)of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home page of IREPS portal for works tenders before submitting the e-tender. 1.General Instruction for E-Tenders on works contract--Chapter- I 2.Special Condition-General- Chapter-II
Opening of e-tender : 1. The e-tenders will be opened online using the IREPS portal anytime after tender closing time. No representative is required to be present for opening of e-tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders through the website after the opening of the tender. 2. The earnest money cost is to be paid through online banking facilities through the online portal and by giving the other details online on website www.ireps.gov.in. Note: For more details refer to Cl: 4 & 12 of General Instruction-Chapter-I for Submission of EMD and opening of e-tender.
Asansol Division: Replacement of Low Insulation/defective Signalling Cable.
50-SDSTE-ASN-2025-26
50-SDSTE-ASN-2025-26
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹2.8 L
18 Mar 2026
23 Feb 2026
4 Mar 2026
69 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,59,78,284.8 | ||
| — | 15.00 | — | — | ||
| Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC- 77/2012 revision 3 With latest Amdt. Inspection: RDSO | — | — | — | 32,775 | |
| — | 15.00 | — | — | ||
| Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost. | — | — | — | 14,340 | |
| — | 80.00 | — | — | ||
| Excavation of trench as per cable route plan in all kinds of soil (1.2 mtr. Depth and 0.3 mtr. to 0.6 mtr width at bottom) and refilling of the trench without bricks and final back filling, ramming and consolidation of soil as well as the disposal of the soil, if any. Note:- Payment will be made as per actual work done on pro-rata basis, if the required depth is not available at site. If the depth of trench is not uniform in a span of 100 M or shorter lengths if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment. Prior permission should be taken from field Officer before laying of cable if the depth of trenching is less than 1 mtr. and duly mentioning location, length etc. in site register. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. For all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. | — | — | — | 1,06,62,352.8 | |
| — | 220.00 | — | — | ||
| Laying of S&T cable of various core sizes as per cable route and cable core plan approved by Railway and meggering of all main & Tail cables. The work to be done as per instruction of Rly. site engineer. Note: All materials (except cable) required for the execution of the work shall be supplied by the contractor. | — | — | — | 19,55,793.4 | |
| — | 1500.00 | — | — | ||
| Excavation of trench of 1.2 mtr. depth from rail flange/road level and 0.3 mtr. to 0.6 mtr. wide, earth work and backfilling after placing DWC/RCC/GI pipe ( placing of DWC/RCC/GI pipe covered separately) , re-instatement of track while track crossing for laying of cables. The ballast disturbed to be screened and dressed and road tarred immediately. This work to be done as per instruction of Rly. Site engineer. All materials (except cable, DWC/RCC/GI Pipe) required for the execution of the work shall be supplied by the contractor. Note: If required depth can not be achieved at particular location, then alternative location to be selected as per instruction of Rly. site engineer | — | — | — | 2,04,630 | |
| — | 2000.00 | — | — | ||
| Transportation of HDD machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) three (03) nos. of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum - 02 nos. Note: - cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer. | — | — | — | 35,16,000 | |
| — | 300.00 | — | — | ||
| Cutting of platform / floor surface/ wall surface for a depth of 20 cm & width of 10 cm & refilling / reconditioning/repairing the surface after laying of pipe, cable. Cutting to be done with machine in proper manner & restore the same as before. | — | — | — | 71,598 | |
| — | 2500.00 | — | — | ||
| Digging of cable trench to a trench depth of not less than 30cms in rockey terrain , concreting the trench with 150 mm thick concrete with 1 cement 2 sand 4 graded stone aggregate 20 mm normal size. All the materials to be supplied by contractor | — | — | — | 6,05,125 | |
| — | 500.00 | — | — | ||
| Boring under Road/Railway track for crossing of s&t cables. Boring to be done for crossing road/rail at minimum 1 mtr. depth & after boring min. 4" dia-meter G.I pipes are to be inserted & cable to be laid through the pipes. GI pipe, cable will be supplied by Rly. For this work, tools , accessories, required materials to be supplied by contractor. | — | — | — | 2,96,350 | |
| — | 130.00 | — | — | ||
| Repair of pucca roads to original state in level crossing area after cable laying. It includes supply of required materials for the work. | — | — | — | 33,280 | |
| — | 6275.00 | — | — | ||
| Supply of Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (2-meter-long) along with collars as per IS No. 458/2003 of NP type. Inspection : RITES | — | — | — | 42,60,725 | |
| — | 12550.00 | — | — | ||
| Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately). | — | — | — | 2,76,100 | |
| — | 2000.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 or Latest with socket & coupling. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: RITES | — | — | — | 21,08,000 | |
| — | 2000.00 | — | — | ||
| Laying & Fixing of Medium class GI pipes 50/100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. | — | — | — | 1,96,000 | |
| — | 50.00 | — | — | ||
| Cement concrete work for miscellaneous items/purpose in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm..Aggregate, cement & sand etc. to be supplied by the contractor for this work. | — | — | — | 1,79,800 | |
| — | 20.00 | — | — | ||
| Masonry work for cutting of the wall for insertion of cable along with repairing of wall with brick, sand and cement & painting / whitewashing after laying of cables as per instruction of site engineer. All masonry item to be supplied by the firm except cable | — | — | — | 5,325.6 | |
| — | 10000.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: Consignee | — | — | — | 90,000 | |
| — | 500.00 | — | — | ||
| Supply and fixing of RCC Cable Route Marker as per ER Drawing No. SI- S&T/1/2024(Sheet-1) and ER technical policy circular no. 108. Inspection: Consignee | — | — | — | 2,08,500 | |
| — | 10.00 | — | — | ||
| Supply of colour light signal post 4.6 mtrs. and ladder 4.5 mtrs. With bases for ladder and post as per RDSO SPEC. NO. IRS-S-6-81 and DRG. NO. SA-23153/ADV/AIT-1. All drawing should be as per latest. Note: - this includes signal post, base, ladder, ladder base, platform, rail guard & blanking off. Inspection: Consignee . | — | — | — | 1,59,500 | |
| — | 10.00 | — | — | ||
| Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips as per DRG. NO. S&T/C-42(NKG). | — | — | — | 80,650 | |
| — | 10.00 | — | — | ||
| Supply of CLS (colour light signal) unit FRP 3 Aspect complete without lens, lamps and signal transformer as per Drg. No. SA 23002/A/M(ADV.) or latest & RDSO/SPN/194/2006 or latest and as per FRP Spec. no RDSO/SPN/151/1997 or latest .Signal unit to be compatible to LED lighting unit. Inspection: Consignee. | — | — | — | 2,73,090 | |
| — | 10.00 | — | — | ||
| Installation, erection and wiring of CLS 3 aspect unit FRP , post, ladder & base complete including paying out of tail cable from location box as per Rly. site engineer. Note:- This includes installation, erection & wiring of signal unit includes fixing, wiring of LED signal lighting unit, current regulator and this also includes protection of unit from rain water. For Installation, erection and wiring all materials including nuts, bolts to be supplied by contractor except Signal post, ladder, base, unit, earth pipe & LED lighting unit. Signal post, ladder, base, unit, LED lighting unit will be supplied by Rly. | — | — | — | 23,520 | |
| — | 10.00 | — | — | ||
| Supply of full size apparatus case(Large) (as per DRAWING NO.RDSO/S-11500. This includes supply of location box (GKP type)with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg .No. 3377 as per RDSO drawing No. RDSO/S-11500. Inspection: Consignee | — | — | — | 1,39,160 | |
| — | 10.00 | — | — | ||
| Casting, concreting, curing and plastering of concrete foundation for full size location box (GKP type)with Cement, sand, Stone Chips in the ratio 1:3:6 and erection of full size apparatus case(location box) as per Drg. NO.S&T/C-6/98(NKG). All materials required for this purpose including holding down bolts, nuts, washer, concreting materials etc. are to be supplied by the contractor. Materials to be inspected by Rly. Site Engineer and the work will be executed as per instruction of Rly. site engineer. Note:-location boxes to be painted with anti corrosive paints ( Asian paint/Berger/Shalimar) as per IS:-9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. | — | — | — | 35,320 | |
| — | 10.00 | — | — | ||
| Fixing of slotted angle, Bakelite strip, hylam sheet, fixing and wiring of terminals, relays, fuse with base etc. and fixing of shelves in Full size steel Apparatus cases(location box) with termination, dressing & bunching of cables/wires, earthling of cables and wiring with necessary lettering as required including supply of wires, slotted angles, ferrules for marking, misc. materials as required per location box. All materials except relay, terminal strips, bakelite strip, fuses with base, charger, D type resistance, B type choke, SSDAC equipment, surge arrester, battery and hardwood shelves to be supplied by the contractor. Wires to be procured from RDSO approved firm and to be inspected by consignee. This includes sand filling and plastering over sand filling. NOTE: All locations to be provided with lamp/holder, switch for lighting as desired by Site Engineer. This should include all Terminations of Cable complete. Cable conductors are to be terminated with proper lugs and required bussbar and other terminals to be supplied by the contractor. | — | — | — | 48,300 | |
| — | 10.00 | — | — | ||
| Painting full size apparatus case (out side & inside) of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. Required lettering outside of location box to be done. NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) | — | — | — | 2,600 | |
| — | 60.00 | — | — | ||
| Alteration/modification in the existing location boxes (full size),fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 1,66,920 | |
| — | 730.00 | — | — | ||
| Supply of fuse, non-deteriorating (2A/6A/10A/16A) type, cylindrical (IRS-S-78/92) [quantity as per Rly. Engineer will be informed during supply]. Inspection: RDSO | — | — | — | 44,530 | |
| — | 300.00 | — | — | ||
| Supply of fuse base (PBT) to spec. no. IRS-S-75/2006(REV-2) or latest, DRG.NO.SA- 23748. Inspection: -RDSO. | — | — | — | 53,400 | |
| — | 10.00 | — | — | ||
| Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. | — | — | — | 53,700 | |
| — | 3000.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) as per RDSO Spec. No. RDSO/SPN/189/2004 Ver. 3.0 with latest amendment. The colour will be decided by Engineer - in -Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3).Inspection: RDSO | — | — | — | 1,65,000 | |
| — | 300.00 | — | — | ||
| Supply of end plate 2.5 mm / 0.91 in width to use with above Disconnect type Terminal Block. Inspection: Consignee | — | — | — | 3,000 | |
| — | 200.00 | — | — | ||
| Supply of end stopper 10mm/0.0394 in width to use with above Disconnect type Terminal Block. Inspection: Consignee | — | — | — | 2,000 | |
| — | 100.00 | — | — | ||
| Supply of steel Carrier Rails of size 35mm x 7.5mm, 1mm/0.039in thickness un- slotted type for placing disconnect type terminals. .Inspection: Consignee | — | — | — | 10,900 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument_SnT.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
GCC Correction Slip
ATTACHMENT
GCC Correction Slip2
ATTACHMENT
mergedGCCCorrectionslip3456.pdf GCC correction slip3456
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf GCC Correction Slip 7 8 9 10
ATTACHMENT
2018-CE-I-CT-9dtd.pdf
ATTACHMENT
Annexure-C.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14.07.2022.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
mergedGCCCorrectionslip3456.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf
ATTACHMENT
AllAnnexure.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
Modified_Cable_cut_JPO_NO._94.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .