| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹6.2 L+₹11,030 (1.81%)Rejected-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹6.4 L+₹26,713 (4.37%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹7.2 L+₹1.1 L (17.8%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical GST NOT FILED |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
25 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
REPAIR TO LIGHTENING PROTECTION, DISTRIBUTION FEEDERS AT VARIOUS BLAST PENS AT 8 FBSU
2021_MES_484742_1
GE(AF) AWA-28/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹20,000
Yes
11 Dec 2021
28 Oct 2021
27 Nov 2021
28 Oct 2021
25 Nov 2021
12 Nov 2021
60 days
Amount
Taking down the existing aluminum/copper strip of any size and type from the top of blast pens/ground/equipment (roof/down conductor) and keeping in shafe custody (for serviceable strips to re-use ), complete all as specified and directed.
Galvanized iron strip 25x4mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints, complete all as specified and directed.
Aluminium strip 25x3 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/jointing and nut bolts jointing at all joints, complete all as specified and directed.
Copper strip 20x3 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing and nut bolts jointing at all joints, complete all as specified and directed.
Copper strip 32 x 6 mm earthing lead laid in trenches/GI pipe for making grid/loop of earthing pit complete all as required at site , complete all as specified and directed.
Refixing only of strip (serviceable strips as obtained from taking down) of any type & size but including saddles/insulators with screws for fixing, complete all as specified and directed.
Replacement of saddle/insulator for strip with fixing arrangement in roof/wall of building having configuration upto G+5 for run of strips on it, complete all as specified and directed.
Replacement of single pointed air termination aluminum rod 12mm dia, 300mm long to fix on wall/roof/pipes with suitable MS clamp, nuts, bolts and washers as required at site , complete all as specified and directed. (Note: MS/PCC work shall be measured and paid seperately).
Brazing in repair work for copper strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness, complete all as specified and directed.
Brazing in repair work for aluminum strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness, complete all as specified and directed.
Replacement of GI tubing 40mm bore light grade in trenches/floor/fixed along pole for cable/earth strip protection with proper size of MS clamp, nut, bolts and washers , complete all as specified and directed.
Plain cement concrete 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in foundation etc. to support the pipe/angle including breaking of existing, complete all as specified and directed.
Dismantling of PCC earth pit chamber and making PCC chamber of size as per electrical plate No. 3 of SSR-2009 Part-I with PCC (1:2:4) type B1 and 40 mm thick cover of RCC (1:2:4, type B-I , using 20 mm graded crushed stone aggregate) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle, including excavation and earth work as required at site, complete all as specified and directed.
Replacement of RCC cover of earth pit of size as per electrical plate No. 3 of SSR-2009, Part-I complete with 40 mm thick cover of RCC (1:2:4, type B-I , using 20 mm graded crushed stone aggregate) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handlecomplete all as specified and directed .
Replacement of funnel with wire mesh suitable for each pit, complete all as specified and directed.
Common salt, nitrates etc for recharging of earthing pits by filling in earthing pits complete all as specified and directed . (Note:- Recharging materials shall be soluble in water and to be filled/poured in earth pit after mixing in water in appropriate quantity.)
Plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm bolted with GI nuts, bolts & check nuts and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm bore GI pipe light grade for earth strip protection complete including provision of concrete pit in PCC 1:2:4 type B-I , using 20 mm graded crushed stone aggregate with 40 mm thick cover of RCC (1:2:4, type B-I , using 20 mm graded crushed stone aggregate) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing complete all as specified and directed.
Plate earthing complete with copper plate electrode 60 cm x 60 cm x 3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including copper earthing strip 20x3 mm bracing/bolted with GI nuts, bolts & check nuts and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm bore GI pipe light grade for earth strip protection completeincluding provision of concrete pit in PCC 1:2:4 type B-I , using 20 mm graded crushed stone aggregate with 40 mm thick cover of RCC (1:2:4, type B-I , using 20 mm graded crushed stone aggregate) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing , complete all as specified and directed.
Installation, testing and commissioning of Chemical Earthing complete with copper plate electrode of size 900mmx600mmx5mm, buried directly in ground vertically to a depth not less than 4.5 meter below normal ground level and complete size of pit 1.2mx1.2mx5.1m, earth plate electrode connected to and including copper earth strip 32 x 6 mm as main earthing lead by means of tinned copper / brass bolts, nuts, check nuts and washers besides brazing at all joints as directed and protected with 40mm dia light grade GI pipe from electrode and upto including the earth test point, 20 mm dia watering pipe light grade GI pipe including funnel, wire mesh, alternate layers of thickness 150mm each of charcoal, common salt, magnesium sulphate/chemical as per manufacturer recommendation around copper electrode plate including one layer of each below and above the plate, including excavation in any type of soil, removal of surplus soil, PCC pit chamber in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 50mm thick in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm dia MS deformed bars @ 75mm c/c both way including MS angle iron frame of 40mmx40mmx3mm complete including testing all as specified. all as specified and directed .
Maint free earthing pit for Equipement/lightening protection comprising of 3 Nos copper bounded earthing Electrode Compound filled , Length 3000mm internal strip size 50X6 Copper bonding electrode diameter 80 mm Make : True Power/ JMV/ Powertrac. Fixed in Three different earth pit of size 3.3 mtr deep placed in a triangular position at a distance 3 mtr each, earth pit filled with charcoal, common salt, magnesium sulphate/chemical as per manufacturer recommendation, earth electrodes inter connected using copper strip of size 20 mm x3 mm and one test point made of copper plate of size 75x75x3mm thick connecting to all three earth pits using copper strip of size 20x3 mm all as required including boring hole and removal of surplus soil , refilling of vegetation soil and fixing FRP Earthing chamber cover on earthing pit & test points, complete all as required and directed.
Moduler box made of FRP / impact resistance plastic & heat resistant materials including provision of MCB SP 6A, connector terminal block 4 pole suit for fixing cable conection and fixing to pole with suitable sizes of clamps, nuts and bolts. MS works duly painted with two coat of synthetic paint with one coat of primer,in replacement,complete all as specified and directed.
Replacement of energy saving, environment friendly, long life, die-cast aluminium housing IP65 flood light luminaire 150watts, 230 volts, 50Hz including LEDs lamp and driver including connecting, complete all as specified and directed. Make:- Havells cat part No. JETA PROPLUSFL150WLED757LTG or equivalent in Crompton/Philips.
Replacement of LED flood light luminaire with high power LED as light source in die-cast housing with IP65 protection 50W including LEDs lamp and driver including connecting to existing power cable, complete all as required and directed. Make:- Havells cat part No. JETA COMPECTOFL50WLED757LTG or equivalent in Crompton/Philips.
Replacement of integral LED aviation light comprising of aluminium housing with polycarbonate enclosure 240 Volt, 50 Hz provided over head tanks / Blast pans / Saft pans/Bldg complete with lamp, driver and all acessories including reducer if required to fix , complete all as specified and directed. Make: Bajaj Cat Part No BGAV 302 LED or equivalent in Crompton/Havells.
Factory made load line DB's double door made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way TPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete with & including one No. MCCB 100 Amps 3 pole 25 kA fixed type for incoming, in replacement, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out in soft/loose soil complete all as specifed and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil, complete all as specified and directed.
Stop valves 20 mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
Note :- An amount of Rs. 12,396.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S Gh Qadir and Sons
FG CONSTRUCTION
M/S BASHIR AHMAD AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .