Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
19 May 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tata Power Delhi Distribution Limited
Development of Façades at existing TPDDL Buildings
200001938
TPDDL/ENGG/ENQ/200001938/26-27
Delhi
1 The bidder must have executed cumulative orders equal to 56 Lacs and one single order of at least 17 Lacs in last 5 years. Order copy/ Completion certificate shall be submitted in this regard. 2 The bidder must have all Statutory Compliance like Valid PAN, ESI registration, EPF registration, GSTN Registration. Bidder must submit the copy of all these Registration certificates. 3 The bidder should have average annual turnover of Rs.56 Lacs in last three financial years. Balance Sheet, profit and loss account statement/ CA Certificate for turn over shall be submitted along with the bid In addition to above, bidders shall also be evaluated on the basis of terms and conditions mentioned in the Special Conditions of Contract (SCC) of this tender document.
₹5,000
₹10 L
28 Apr 2026
28 Apr 2026
19 May 2026
Earth work in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil. as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level-1:1.5:3 (1 Cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centring and shuttering including struttting ,propping etc.and removal of form for : Foundations , footings , bases of columns etc for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centring and shuttering including struttting , propping etc.and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size (Recycled Concrete Aggregate (RCA) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement: a) 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) : 3graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs havingslope up to 15° landings, balconies,shelves, chajjas, lintels, bands,plain window sills, staircases and spiralstair cases above plinth levelup to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement, with 1:1.5:3(1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Centring and shuttering including struttting ,propping etc.and removal of form for : Shelves(Cast in Situ)
Laying and fixing in position HYSD bar reinforcement (FE-500grade) as per IS : 1786, for RCC in situ and precast work including cost of supplying, straightening, cutting, bending and binding with 16 gauge MS annealed binding wire, cement mortar spacer blocks etc. complete as per drawing, specifications, and as directed by the Engineer.All chairs, laps, spacers are payable, but as per actual measurement.a)Thermo -Mechanically Treated bars of SAIL, TISCO, IISCO or RINL.
Extra for additional height in centring, shuttering wherever required for RCC slab, beam etc., false ceiling with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 metre for every additional height of 1.0 metre or part thereof. (Plan area to be measured).a) Suspended floors, roofs, landing, beams and balconies
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 in superstructureabove plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry
Providing and laying autoclaved aerated cement blocks masonry with 100 mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 Kg/m3 conforming to IS 2185 (Part-3)in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. Granite stone of any colour and shade
Providing and fixing dry cladding upto 10 metre height with 30 mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). White sand stone - 30 mm thick gang saw cut stone
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in therequired pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).
Providing and fixing adjustable stainless steel cramps of approved quality,required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.a) In gratings, frames, guard bar, parking structure, railings, brackets, gates & similar works.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement : 4 coarse sand).
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
18 mm cement plaster in two coats under layer 12mm th cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6mm th cement plaster 1:3 (1cement : 3 coarse sand) finished rough with sponge.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. ( Rate for per 50 kg bag of cement used in cement plaster work)
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On Steel works
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete works
Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and ncluding priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and applying two or more coats of Premium Acrylic Smooth Exterior paint with Silicone additives of Asian Paint Apex Ultima or as approved with primer coat as recommended by Manufacturer and as directed by the engineer in charge.(for all heights including double scaffolding, cleaning, curing etc complete as per specifications and as directed by engineer-in-charge)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge. Nominal concrete: 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 met res lead as per direction ofEngineer-in-charge
Demolishing brick work manually /by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-In-charge.: In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area 3 sq. metres and below
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area beyond 3 sq. metres
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 m lead.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead:For thickness of tiles 10 mm to 25 mm
Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling aluminium/ Gypsum partitions, doors windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50m lead as directed by Engineer-in- Charge.
Disposal of building rubbish / malba similar unserviceable, dismantledor waste materials by mechanical means, including loading, transporting,unloading to approved municipaldumping ground or as approved by Engineer-in-charge, beyond 50 m initiallead, for all leads includingall lifts involved.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/ sqm)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Windows
Doors
Ventilations
Providing and Fixing of 6mm Exterior Grade HPL of make Greenlam /Mikasa FX 30103 Walapter Oak 6mm thick (1220x2440mm) over necessary MS Framework with Square Box Section 50x50x2.9mm Hot Dip Galvanised t. The Projection of HPL to be 500mm from the base structure fixed with MS Base Plate of size 200x200x10mm fixed with 12mm Fasteners. The HPL Sheet to be cut in necessary sizes as per site engineer and fixed with matching PVD Coated Rivits. Exterior CLAD HPL should be made under high pressure, using thermosetting Phenolic resin treated kraft layers, Amino plastic resin treated Exclusive & UV conforming Exterior Grade Decorative paper on both sides and UV protection layer above the décor papers on both sides. Clad should be resistant to wet conditions and meets permissible increase on mass, have density >1.35 gm /cm3, UV resistance of a minimum of 4 on a grey scale rating after 1500 hours, Resistance to artificial weathering including light fastness of a minimum rating of 4 (after 650 MJ/m2 radiant exposure). The product must conform to European Fire-Retardant norms of Bs1d0 when classified in accordance with EN 13501-1. The Fire-Retardant Additive must be Halogen free to protect the environment. (Base Rate of HPL - 325 Rs/ Sqft ) , Rate of M.S Frame work and scaffolding are included in the item )
Providing, fixing fabrication M.S Louvers of Size 100x200mm x 2mm thick M.S Tubes with Powder coating 50 micron in desired colour and shade on louvers in position. The M.S tube shall be installed on site with required size brackets at locations as indicated in tender drawings. Rate shall include supply and installation of M.S tubes with brackets and other required hardware. All complete inlcusive of accessories and fastners as required. All complete as per tender drawings and direction of Engineer-in-Charge.Shop drawings to be submitted by the Contractor before execution of fabrication work. Nothing extra shall be paid on account of its framing system M.S Vertical Louvers ( 100x200 mm )
Providing, fixing fabrication fins with extruded aluminum section with Powder coating 50 micron in desired colour and shade on fins in position. The aluminum extrusion shall be installed on site with mullion aluminum brackets at locations as indicated in tender drawings. Rate shall include supply and installation of flat bar to brackets which are off from unitised glazing inlcusive of accessories and fastners as required. 3mm thick profile of fins shall be as per per detail drawings and approved design shall be fixed on Aluminum faming. Fins shall be Fixed to the aluminum frame (with fixing details ) All complete as per tender drawings and direction of Engineer-in-Charge.Shop drawings to be submitted by the Contractor before execution of fabrication work. Nothing extra shall be paid on account of its framing system Aluminium Vertical Fin( 150x150 mm )
Providing and Fixing ( Drilling, cleaning, injecting chemical) Chemical rebar shear connectors straight or L type with ‘HIT HY-200 of HILTI’ or FISCHER / WURTH make with 20 x d embedment (where 'd' is the diameter of reinf bar) with shock approval, seismic rebar approval,100 years service life, fatigue and fire approvals.. Rate shall include for drilling hole in concrete / masonry with drilling machine, cleaning, grouting and fixing reinforcement for required length, injecting the hole by approved chemical resin hardener etc. complete and making good the surface of concrete/ masonry after inserting the rebar. rates shall also include for necessary drilling, cleaning, scaffolding, tools/ tackles, removal of wastage, etc. complete. 'HILTI' or other approved equivalent. No additional payment shall be made for extra drilling at location where reinforcement is encountered. For all floors/ all levels/ all heights. Rate to include pull testing of anchors @ 1% by the total application quantity at representative areas. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. DIAMETER RANGE BE FROM FROM 8MM TO 32MM
Providing and fixing of New TATA Power DDL ACP BASE Acrylic Logo on canopy /wall on MS Frame structure by using new MS members for fabrication etc. complete in all respect as per direction of EIC. Materials Descriptions. 1. ACP Sheet: 3mm White Eurobond or equiv make ACP sheet 2. Letters: 5mm thick imported white acrylic finish with laser cut, 2” rim right around for the letters, front & fully covered with acrylic. 3. Acrylic for the logos: 5mm white imported Acrylic for the logos. 4. Vinyl for the letters: LG/Avery or equiv brand vinyl to be used. 5. LEDs: 1Watt LED modules for the illumination with 5years warranty. 6. Power supply: UNION make 250watt LED converter or equiv 7. Wiring: Finolex brand Wires will be used for the wiring & connections.
1.0 CABINET STRUCTURE & FRAME WORK: Size 6.0 X 1.0M The box frames should be made from MS square pipe as basic structure acting as runners along the length, height & width of the box. The MS square hollow pipe has to be 16 gauge thickness for mainframe, verticals and for cross sections (bracings). The verticals should be spaced at 18’’ Box frames. 1.1 M.S structures:- The box frames size is 6.0 X 1.0M and frame should have MS square pipe as basic structure acting as runners along the length, height & width of the box. The MS square hollow pipe has to be in square cross section of 1.0 inch by 1.0 inch and 16 gauge thickness for mainframe, verticals and for cross sections (bracings) & anti rust paint on it. L angle shall be used for the supports & fixing for structure(*The depth of the framework shall measure 6 inches inner to inner and shall be covered with ACP of required colors). Post grinding the joints, the MS pipe has to be painted with zinc chromate primer and 2 coats of synthetic enamel paint of white shade 1.2 FRAME WORK SUPPORT: The sign cabinet should be provided with suitable arrangements for fixing to existing wall surface or existing supporting structures available with suitable clamps, brackets, anchor bolts etc.. The arrangements should be adequate to support the weight of the cabinet and to keep it firmly in position. Nothing extra will be paid for fixing the cabinet in position 2.ACP SHEET WORKS :-FASTNERS: The fasteners used shall be uniform and at such spacing that it does not spoil the appearance of the signage looking from the bottom or the sides. The head of the screw shall have capping. of stainless steel.as per the guidelines. Top panel of the main frame box should be covered with ACP sheet in approved shade . The side and bottom panels of the box should also be of same material and finished in a similar manner. Side panels should be suitably machine-pressed/punched to make fins/slits to dissipate the heat generated when the sign is back lit. The slits should be such that water should not enter inside. The cutting and bending of sheets shall be done in a machine to get uniform straight edges
Fixing of Acrylic of TATA POWER logo & letters ( each letter of size 1M height height & different width’s as under: Letters sizes approx as/drawing with back lit LED’s placed over sun board base over and above ACP base ,SIDE EDGES(4’’) :-5 mm transparent white acrylic sheet with laser cut(using AMADA Laser cutting m/c) & 4inches manual Raising all around .( pl see photos attached) with details.ACRYLIC SHEETS & ITS TECHNICAL PARAMETERS( to be used forTATA POWER in capital letters) :- Front: a. 5mm White imported (Mitsubishi/equivalent) acrylic cutting on laser cutting machine. b. The illumination percentage of 040 white acrylic is 51(min) c. Flexi bond make 25mm Sun board for the Round logo and back of the Letetrs. ( (sheets Cutting shall be on CNC router machine only).Acrylic letters of “TATA POWER ” shall have 5 mm thickness Imported white color with laser cuts , 2’’ rim right around the letters ,front and fully covered with acrylic materials. the LED’s for back lit, replacing the Vinyl. Pasting new vinyl stickers over the ACRYLIC substrate shall be undertaken with all care and techniques such as using pre mask tapes to the vinyl before initiating the fixing of the same over the acrylic sheets, it shall be ensured that vinyl is properly aligned to the acrylic without any gaps at the outer edges, there are no air bubbles, etc., The workmanship shall be of high standards and engineering.Buffing for Stainless steel to be done on existing LOGO . Vinyl for the logo: The vinyl( LG/Avery/3M or equiv) for the round logo & also for Nine Letters of” TATA POWER ” with glossy /Mat lamination.
Scaffolding Installation charges SAFETY AT SITE: The signage solution providers shall duly assess the site condition for fixing scaffoldings securely by appropriate means using necessary clamp, hooks, fasteners and including minor civil works necessary at site. The entire signage so fixed at site shall withstand high wind pressures depending upon the actual locations / floor in which it is installed
Installation of complete unit , assembling and handling charges with testing , commissioning. Please note that It shall also be the responsibility of the signage solution provider for the safety of the installation, the signage till they are billed and accepted by the TATA POWER . While executing the work the labour force used shall comply to labour laws and all necessary safety measures shall be undertaken like using scaffolds, ladders, safety belts, helmets, gloves, appropriate tools are only utilised. Suitable precautions shall be taken against overhead power lines, slippery surface or such other hazards which may be in the close proximity to the premises / site. Any damages to the signage during the process of installation will result in rejection of the signage and the same shall be replaced at their own cost.
Dismantling polycarbonate staircase roof and steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead.
Dismantling MS platform, by detaching from the existing main gallery and stacking the serviceable as directed. Nominal dimension of platform 2.0 x 1.5 mt.
Providing and fixing railing, rectifying railing as required and as directed, in staircase, passages etc. with MS flats, plates, tube, solid bar sections one end welded to horizontal flat to adopt handrail, and other end embedded in concrete/concrete block of size 10x10x15 cm in brick work / RCC work alongwith base shoe as required all complete with Aliphatic Weather Resistant Polyurethane, brush application, coverage 10-12 sq.mt. per kg, over a priming coat as required.(Mild steel shall be as per IS:2062)
Providing and fixing Luxalon SL-4 Louvers in 84R Plain Panel manufactured by M/s. Hunter Douglas India Pvt. Ltd. of approved colour consisting of panel 84 mm wide x 16mm deep x 0.6mm thick with round edges panel length up to 6mtrs coil coated on a continuous paint line double baked and roll formed from enameled corrosion Resistance Aluminium Alloy AA3005 (Al.Mg.) for higher strength and good Roll forming characteristics. Panels shall be clipped to baked enameled Aluminium SL-4 panel stringer 33mm wide and 86mm deep x 0.95 mm thick in a standard length of 5mtrs made of double baked enameled Aluminium Alloy AA5050 (Al.Mg.) to hold the panel in a module of 86mm . The prongs on SL–4 stringers shall be to accommodate an angle of 21.30 Degrees between two panels.. The carrier shall be fixed to a suitable structure by means of rigid fixing details. All properties and specifications shall comply with ECCA directives and more specifically EN 1396:1996a) Paint Finish: -Panel shall be stove enamelled and finished with Luxacote, a patented special three layered coating system (consisting of first a conversion layer of thickness 800-2000mg/sq mtr, a polyurethane basecoat of 16-20 microns, and a special top coat of polyamide particles of 8-12 microns thick to provide excellent abrasion and damage resistance) in a continuous coil coating process of the approved colour on the exposed side and the reverse side with epoxy
Providing and fixing aerodynamic shallow double face convex design, corrosion Resistance Aluminium Alloy, aluminium Façade Fin Louvres, sun control and architectural feature louvres, 350 ~400mm nominal width fixed louvres, height varying from 3.0 mtrs to 7.0 mtrs, ALSTONE make or equivalent, shall be color coated suitable to weathering, shall be fixed to appropriate runners/ carriers. The carrier shall be fixed to a suitable structure by means of rigid fixing details as recommended by the manufacturer. One side surface area of the feature louvres shall be considered for payment.
Providing and laying RCC bands of M25 concrete in new brick work appropriate for bonding to the existing brick work, by inserting reinforcement to existing wall by REBAR system shall be 115 thick, inclusive of reinforcement, shuttering, and including 4 nos Rebar for each RCC band by using HY- 200 CHEMICAL OF HILTI, complete in all respects.
Dismantling old plaster, raking out joints and cleaning the surface for new plaster including disposal of rubbish to the dumping ground within 50 metres lead, rendering with new plaster 15/18mm thick plaster in cement mortar 1:6( 1 cement: 6 coarse sand) including chipping of rough surface and making the rendered surface as good and complete as the rest of the retained plastered surface. This is a composite item of dismantling and rendition, area of such item of work limited to 25.00 sq.mts.
Providing single skin colour coated Aluminium Troughed Industrial roofing sheets, 1044 mm wide, 0.71mm thick, 125mm pitch & 38mm depth having 8 no of pitches, as per IS 1254 & 737, for roofing, side cladding, with necessary flashings, gutter ec. complete including all accessories and fastening arrangement.
Providing and fixing 65 cm over all profiled plain G.S sheet (0.8 mm thick) gutter, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete.
Providing of flashing over sheet roofing wherever required of same approved colour etc 0.5mm thick as required for the completeness of work.
Providing and laying damp proof course 40mm th.with cement concrete 1:2:4 ( 1cement: 2 coarse sand: 4 graded stone aggregate12.5mm nominal size including mixing waterproofing material 'Impermo' or equiv. in cement conc. @ 1kg/ 50kg of cement,and applying residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg /sq.m. on DPC after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Providing and laying in position machine batched, machine mixed and vibrated cement concrete of specified grade for reinforcement cement concrete structural elements, including the cost of finishing excluding reinforcement. including admixtures in recommended proportions. (as per IS 9103) to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of engr. in charge -M-15 grade reinforcement cement concrete.Minimum cement content shall be 280kg/ cu.m..a) bed blocks.
Providing, fabrication, fixing and embedding in concrete/brick work such as plates, bolts, nuts sleeve and other embedded parts including making provision in shuttering painting with two coats of anticorrosive or other approved paint over a coat of approved primer etc. all complete.
Providing and fixing G.I. chicken wiremesh on concrete and masonary joints as per direction of the EIC
CIRCUIT/ SUB-MAIN WIRING IN PVC CONDUIT : WIRING FOR CIRCUIT SUBMAIN WIRING ALONGWITH EARTH WIRE WITH THE FOLLOWING SIZES OF PVC INSULATED COPPER CONDUCTOR,SINGLE CORE CABLE IN SURFACE/ RECESSED PVC CONDUIT AS REQUIRED 2 X 2.5 SQ. MM + 1 X 2.5 SQ. MM EARTH WIRE.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 15/16 amp switch.
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING 18W/20W LED DOWN LIGHTERS LUMINAIRE OF PHILLIPS/SYSKA/HAVELLS/CROMPTON/BAJAJ MAKECOMPLETE INCLUDING CONNECTIONS WITH COPPER CONDUCTOR AND EARTHING ETC AS REQD.
POINT WIRING IN PVC CONDUIT, WITH MODULAR TYPE SWITCH : WIRING FOR LIGHT POINT/ FAN POINT/ EXHAUST FAN POINT/ CALL BELL POINT WITH 1.5 SQ.MM FR PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE IN SURFACE / RECESSED PVC CONDUIT, WITH MODULAR SWITCH, MODULAR PLATE, SUITABLE GI BOX AND EARTHING THE POINT WITH 1.5 SQ.MM. FR PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE ETC AS REQUIRED.GROUP-B
Providing and fixing profile light including controller etc complete as per direction of engineer incharge
P/F Flexible LED strip with 15 W LED 2700 K Indoor
SITC of 12 W surface COB LED Cylindrical spot light for ceiling ,complete with all accessories etc as required Philips make
Providing and fixing of Focus light 7 wt of Phillips make as per direction of engineer incharge.
S/F modular boxes, base & cover plate : Supplying and fixing following size/ modules, G.I. box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200 mm X 75mm).
S/F modular boxes, base & cover plate : Supplying and fixing following size/ modules, G.I. box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200 mm X 150 mm).
S/F PVC CONDUIT : SUPPLYING AND FIXING OF FOLLOWING SIZES OF PVC CONDUIT ALONG WITH ACCESSORIES IN SURFACE/RECESS INCLUDING CUTTING THE WALL AND MAKINGGOOD THE SAME IN CASE OF RECESSED CONDUIT AS REQUIRED. 25MM
SITC of 5 W surface LED wall washer light decorative as specifications including all
Rectification in electrical cable routing and re-laying by installing the existing cables in cable trays. The same shall be done by supply, fabrication and installation of G.I factory built in perforated type cable trays with cover complete with all bends, tees, elbows, reducers etc. of various width in one/ two or three tier fashion either on one side of the wall or on two sides of the wall or at other places and paint afterward if required. (All bends & tees shall be of factory built in of same make as that of tray).a) 50 mm tray, 2mm thick, 50mm collar with 2.5mm thick cover
Rectification in electrical cable routing and re-laying by installing the existing cables in cable trays. The same shall be done by supply, fabrication and installation of G.I factory built in perforated type cable trays with cover complete with all bends, tees, elbows, reducers etc. of various width in one/ two or three tier fashion either on one side of the wall or on two sides of the wall or at other places and paint afterward if required. (All bends & tees shall be of factory built in of same make as that of tray).b) 150 mm tray, 2mm thick, 50mm collar with 2.5mm thick cover
Rectification in electrical cable routing and re-laying by installing the existing cables in cable trays. The same shall be done by supply, fabrication and installation of G.I factory built in perforated type cable trays with cover complete with all bends, tees, elbows, reducers etc. of various width in one/ two or three tier fashion either on one side of the wall or on two sides of the wall or at other places and paint afterward if required. (All bends & tees shall be of factory built in of same make as that of tray).c) 300 mm tray, 2mm thick, 50mm collar with 2.5mm thick cover
Rectification in electrical cable routing and re-laying by installing the existing cables in cable trays. The same shall be done by supply, fabrication and installation of G.I factory built in perforated type cable trays with cover complete with all bends, tees, elbows, reducers etc. of various width in one/ two or three tier fashion either on one side of the wall or on two sides of the wall or at other places and paint afterward if required. (All bends & tees shall be of factory built in of same make as that of tray).d) 450 mm tray, 2mm thick, 50mm collar with 2.5mm thick cover
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
S0056-28-04-2026 05-25-18 PM-Tender 200001938_TPDDL-ENGG-ENQ-200001938-FY 26-27.pdf
Tender Document • 0.78 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Annexure I BoQ.pdf
Tender Document • 0.65 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Annexure I BoQ.xlsx
Tender Document • 0.04 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Facade Corp off-1.pdf
Tender Document • 0.07 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Facade corp off-2.pdf
Tender Document • 0.12 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Facade corp off-3.pdf
Tender Document • 0.12 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Facade Corp off.jpg
Tender Document • 9.96 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Facade view CVl-III (2).jpg
Tender Document • 0.14 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Facade view CVL-III.jpg
Tender Document • 0.16 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Inderpuri View 1.jpg
Tender Document • 0.15 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Inderpuri view 2.jpg
Tender Document • 0.15 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Inderpuri-1 (2).pdf
Tender Document • 0.06 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Inderpuri-2 (2).pdf
Tender Document • 0.05 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Inderpuri-3 (1).pdf
Tender Document • 0.05 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Inderpuri-4 (1).pdf
Tender Document • 0.06 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Inderpuri-5 (1).pdf
Tender Document • 0.06 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_Inderpuri-6 (1).pdf
Tender Document • 0.09 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_TPDDL-CIVIL LINE FACADE DRAWNGS (16-04-2026)_page-0001.pdf
Tender Document • 0.06 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_TPDDL-CIVIL LINE FACADE DRAWNGS (16-04-2026)_page-0002.pdf
Tender Document • 0.06 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_TPDDL-CIVIL LINE FACADE DRAWNGS (16-04-2026)_page-0003.pdf
Tender Document • 0.06 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_TPDDL-CIVIL LINE FACADE DRAWNGS (16-04-2026)_page-0005.pdf
Tender Document • 0.07 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_TPDDL-CIVIL LINE FACADE DRAWNGS (16-04-2026)_page-0006.pdf
Tender Document • 0.08 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_TPDDL-CIVIL LINE FACADE DRAWNGS (16-04-2026)_page-0009.pdf
Tender Document • 0.07 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Concept drawings_Concept drawings_TPDDL-CIVIL LINE FACADE DRAWNGS (16-04-2026)_page-0010.pdf
Tender Document • 0.06 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_GCC-Service.pdf
Tender Document • 2.98 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Other Approved Makes.pdf
Tender Document • 0.17 MB
S0056-28-04-2026 05-25-18 PM-Tender 200001938_Safety Bid.pdf
Tender Document • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .