Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.9 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹54.2 L+₹2.3 L (4.49%)Rejected-Finance | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹78.4 L+₹26.5 L (51.0%)Rejected-Finance B 12 10 EWS VILLAGE TOWN SECTOR 71 CITY NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 INDIA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L3 | Rejected-Finance NOT L1 BIDDER | |
| 4 | Rejected-Technical C 2 14A RAJU PARK KHANPUR NEW DELHI 110062 | NEW DELHI | NEW DELHI | DELHI | 110062 | - | Rejected-Technical DIS-QUALIFIED |
Tender Value
Refer Docs
Closing Date
27 Jun 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GC (MMG)
C-56/1, ANUSANDHAN BHAWAN, SECTOR 62, NOIDA - 2013019
REPAIR AND STRENGTHENING OF EXTERNAL STONE CLADDING EXTERNAL PLASTERING AND FIXING OF S S FRAME ANCHORS
2022_DIT_693137_1
9(5)/2022-MMG
Open Tender
Civil Works - Buildings
Works
120 days
CDAC NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
CDAC NOIDA
31 Aug 2022
6 Jun 2022
28 Jun 2022
6 Jun 2022
27 Jun 2022
22 Jun 2022
10 Jun 2022
120 days
GENERAL : All items of work contracted for shall be executed strictly in accordance with the description of the item in the Bill of Material; specifications read in conjunction with the appropriate Indian Standard specifications and conditions of the contract and established Engineering practices.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of G + 6/ G + 4 storied building/structure up to 30 meter height above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm diameter M.S. tube, placed 1.5 meter centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in- charge. The elevation area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - 1. This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 2. The staging area of additional Tubular Frames for supporting double scaffolding system, if required shall not be measured for payment purpose. 3. Labors working on the scaffolding should be provided with safety belts, helmets and they should wear the same while working. 4. Suitable nylon of adequate strength nylon net around the working area of the building including curtain covering shall be fixed to catch any falling objects. 5. Scaffolding shall be measured once only and the same shall be maintained till the work is completed. 6. The building is up to G + 6 storied and hence the contractor has to observe all safety procedure while working on heights as per IS 3696 (Part-I)-1987.
Dismantling the existing Dholpur or / Chima Pink Granite stone cladding in the exterior side of G + 6/ G + 4 storied building/structure up to 30 meter height above ground level, including window borders & sides laid in cement mortar at all levels of building including stacking serviceable stones for reusing and disposal of unserviceable material within 50 meters lead.
Removing cement mortar from serviceable stone slabs including cleaning the stones for reusing (net quantity of stacks of cleaned mortar materials will be measured)
Dismantling filling mortar / materials / plaster of stone cladding from the external wall surfaces on the exterior side of G + 6/ G + 4 storied building/structure up to 30 meter height above ground level, including raking out brick work joints, machine cutting cheema stone granite around windows, ventilators / structural glazing to match the plastering levels and cleaning the wall surfaces for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Stone work (machine cut edges) for wall lining etc. (veneer work) at all levels up to 27 metre height, backing filled with a grout of average 40 mm thick or more to match the wall cladding level surfaces in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone complete (The rate is inclusive of all materials & labours involved except scaffolding) for following:
Providing and fixing Dholpur Stone /Sand Stone matching with existing shade and finish - Exposed face machine cut and table rubbed with rough backing, 20 to 30 mm thick
Providing and fixing Chima Pink Granite stone matching with existing shade and finish - Exposed face machine cut and table rubbed with rough backing, 20 to 30 mm thick
Labour charges for fixing dismantled Serviceable Dholpur Stones including cutting to required sizes (Note: Dholpur stones will be issued free of cost).
Labour charges for fixing dismantled Serviceable Chima Pink Granite stone including cutting to required sizes (Note: Chima Pink Granite stone will be issued free of cost).
Providing and fixing Fire Tested & ETA approved Stainless Steel A2 (SS 304) frame Anchor of size10x140mm, Counter sunk head, of Hitachi Koki India, Fischer or HRD-CR2 10 Hilti India for anchoring stone cladding with their sheaths comprising of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade Hex head double threaded screw(sample to be pre-approved by the department) on external wall cladding of Anusandhan Bhawan Building comprising of G + 6 / G+4 upper floors for securing the existing Dholpur stone / Chima Pink stone of assorted sizes & 50/65 mm thickness (avg. with base mortar) for cladding of external wall surfaces to the RCC/PCC/Masonry members of the main structure behind including mechanical drilling of holes using Dual-mode SDS rotary hammer (hammer drilling and drilling) Sturdy motor with high load rating for maximum reliability carefully using 10/12 mm dia. hammer drill bit with 4 carbide cutting edges for drilling anchor holes into concrete with rebar to full length of the bolt, cleaning the drill holes with compressed air for removing dust, dirt etc., installing the Frame Anchor set and mechanical driving or the bolts @ 2 Nos. per slab or as required, 150 mm from the nearest edge, in the pattern specified by the Department taking every care not to break the stone slabs in the process not to damage the bolt head grooves (due to frequent slipping) etc. complete all as per specifications and as directed.
Providing 18 mm cement plaster for exterior walls of G + 6/ G + 4 storied building/structure up to 30 meter height above ground level, in two coats, under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including providing and mixing water proofing material in proportion recommended by the manufacturers.
Demolishing cement concrete for coping of parapet wall manually/ by mechanical means including disposal of material within 50 meters lead as per direction of Engineer - in - charge.
Providing and laying cement concrete1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) in parapets, coping, sills, fillets etc. up to sixth floor roof parapet level including the cost of centering, shuttering and finishing etc. complete.
Finishing walls with textured exterior paint on the exterior side of G + 6/ G + 4 storied building/structure up to 30 meter height above ground level,in required shade of approved brand and manufacture in two or more coats applied @ 3.28 ltr/10 sqm over and including priming coat of acrylic exterior primer applied @ 2.20kg/10 sqm including thoroughly cleaning all mortar dropping, dirt dust, algae, fungus or moth, grease and other foreign matter of brushing and washing, pitting in plaster shall make good, repairing surface imperfections such as cracks, holes using white cement etc. complete.
Providing cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand) mixed with water proofing material in cement per bag of plaster work in proportion recommended by the manufacturers and applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound including rounding off junction of stone cladding edge and vertical wall surface etc. complete all as directed.
Disposal of building rubbish/ malba/ stone slabs or similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead up to 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - Item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.
Providing and fixing top hung ventilator (Outwards opening) in Aluminum framework to the existing structural glazing up to 4th floor level with Concealed integrated friction stays ensure an outward opening also for large size sashes, with a secure opening fixation in any position, all aluminum work with powder coated aluminum (minimum thickness of polyester powder coating 50 micron ivory color) in existing panels of overall inside clear size 3Ft.-1inch X 2Ft.-4 inches approximately, providing and fixing ventilators frame of size as required as per site conditions along with shutter panel made with powder coated aluminum (minimum thickness of polyester powder coating 50 micron ivory color of matching shade) with extruded built up standard tubular sections/appropriate sections 1¾" X1¾" for shutter, L-Angle frame 1"X1.5" for ventilator, 2½"X2¼" / or existing box section as per site conditions and as directed, Providing and fixing toughened reflective window glass panes 6 mm thick of sapphire blue colour / matching shade of Saint Globin or equivalent approved brand and manufacture for ventilator shutter in each windows, providing fixing aluminum grill and framework in round shape to restrict pigeon’s entry in open position of ventilator including providing and filling joints between glass panels (6 to 8 mm) with two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant including double sided spacer tape so as to make the entire system fully water proof & dust proof including cost of all labour, T&P, Tubular M.S. Pipe double scaffolding, C.P. brass / stainless steel screws, dismantling carefully the existing glazing glass for ventilator locations and other incidental charges including wastage etc. repairs etc. complete all as directed. Note: (i) The size as shown for toughened glass is approximate, the Contractor shall take actual measurement at site and also note down the color / shade of the existing glass, before starting the work. The quoted rate shall be inclusive of cost of toughened glasses. (ii) The contractor’s workers shall follow all safety precautions while working at height. (iii) The quoted rate shall be inclusive of Tubular M.S. Pipe double scaffolding, dismantling and disposing off the existing damaged glazing glass, cost of all labour, T&P and other incidental charges including wastage etc. (iv) The mode of measurement of ventilators shall be as per actual area in elevation (Height X Breadth) fixed at site.
ABS INFRA
pramod bahl and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .