Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.0 L+₹3.9 L (9.60%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹45.2 L+₹4.2 L (10.2%)Rejected-Finance KOHLI NO 17509 GALI KHADDAR BHANDAR WALI BHI WALA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹45.9 L+₹4.8 L (11.8%)Rejected-Finance 1227 MODEL TOWN MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹46.2 L+₹5.1 L (12.5%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s BALDEV SINGH L8 | M/s BHUPINDRA ENGINEERING WORKS L3 | M/s Vee Kay Associates L5 | M/s VISHAL ELECTRIC STORE L4 | Rasvinderpalandco L1 | REYANSH GARG AND COMPANY L2 | GUPTA AND ENGINEERS L7 | KAY VEE CONSTRUCTIONS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for repair, maintenance and restoration of LED light fitting any wattage such as street lights, security lights, flood lights or any other type of external led light fitting, whether fixed in position on poles, high masts, buildings/structures or other supports, including carrying out the work in position or taking down the light fitting to ground level wherever required, inspection and testing of all components, parts, wiring and electrical connections, identification and rectification/replacement of defective components such as electronic drivers, connectors, terminals and other minor components, checking and tightening of loose connections, tightening of loose fitting, replacement of nut bolt, checking and rectification of incoming and outgoing wires at junction boxes, minor repair of wiring and connections, minor repair and maintenance of street light control timer, junction box and associated fittings, including refixing and securely restoring the light fitting to its original position after completion of repair, testing for proper functioning and illumination, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: (i) The quoted unit rate shall be deemed to include the cost of all labour, tools, tackles, lifting/access arrangements, taking down and refixing of light fittings, and all minor consumables and components, including electronic drivers, connectors, terminals, lugs, insulation tape and other incidental items required for completion of the work.
(ii) Only the repaired light fitting shall be measured and paid for under this item. No separate payment shall be admissible for inspection, checking, tightening of loose connections, tightening of fittings, or minor repairs carried out in junction boxes, timer/control boxes or other common control arrangements serving one or more light fittings, the cost of which shall be deemed to be included in the quoted unit rate.
(iii) In case replacement of an MCB is required, the same shall be measured and paid for separately under the relevant BOQ item. | 295 | Each job | 150 ₹44,250 | 150 ₹44,250 | 150 ₹44,250 | 150 ₹44,250 | 120 ₹35,400 Lowest | 123 ₹36,285 | 200 ₹59,000 | 125 ₹36,875 |
| 2.00 | Material and labour for repair, maintenance and restoration of light fitting other than LED any wattage such as street lights, security lights, whether fixed in position on poles, buildings/structures or other supports, including carrying out the work in position or taking down the light fitting to ground level wherever required, inspection and testing of all components, parts, wiring and electrical connections, identification and rectification/replacement of defective components such as choke (ballast), igniter, capacitor, lamp, lamp holder, connectors, terminals and other minor components, checking and tightening of loose connections, tightening of loose fitting, replacement of nut bolt, checking and rectification of incoming and outgoing wires at junction boxes, minor repair of wiring and connections, minor repair and maintenance of street light control timer, junction box and associated fittings, including refixing and securely restoring the light fitting to its original position after completion of repair, testing for proper functioning and illumination, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: (i) The quoted unit rate shall be deemed to include the cost of all labour, tools, tackles, lifting/access arrangements, taking down and refixing of light fittings, and all minor consumables and components, including choke (ballast), igniter, capacitor, lamp, lamp holder, connectors, terminals, lugs, insulation tape and other incidental items required for completion of the work.
(ii) Only the repaired light fitting shall be measured and paid for under this item. No separate payment shall be admissible for inspection, checking, tightening of loose connections, tightening of fittings, or minor repairs carried out in junction boxes, timer/control boxes or other common control arrangements serving one or more light fittings, the cost of which shall be deemed to be included in the quoted unit rate.
(iii) In case replacement of an MCB is required, the same shall be measured and paid for separately under the relevant BOQ item. | 5 | Each job | 250 ₹1,250 | 250 ₹1,250 | 250 ₹1,250 | 235 ₹1,175 | 150 ₹750 | 130 ₹650 Lowest | 280 ₹1,400 | 275 ₹1,375 |
| 3.00 | Supply and fixing in replacement of energy-efficient LED security light fitting/street light of 60 Watt, complete with pressure die-cast aluminium housing/body with top-opening driver cover for easy maintenance, heat-resistant clear toughened glass and suitable optical system for uniform distribution of light, complete with LED module, LED driver and all necessary internal components, terminals, connectors. The work shall include taking down and removing the existing defective/obsolete light fitting of any make and condition, whether fixed in position on poles, high masts, buildings/structures or other supports, fixing the new LED light fitting on the existing suitable bracket/support, making necessary electrical connections, proper alignment and adjustment, testing for satisfactory illumination and ensuring proper and safe functioning of the complete fitting, complete in all respects as specified and directed by the Engineer-in-Charge.
Technical specification :-
(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range: Minus 10°C to Plus 50°C (d) Power factor: Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) | 94 | Each | 5,500 ₹5,17,000 | 4,600 ₹4,32,400 | 4,600 ₹4,32,400 | 5,000 ₹4,70,000 | 4,150 ₹3,90,100 Lowest | 5,220 ₹4,90,680 | 5,000 ₹4,70,000 | 4,500 ₹4,23,000 |
| 4.00 | Supply and fixing in replacement of energy-efficient LED security light fitting/street light of 45 Watt, complete with pressure die-cast aluminium housing/body with top-opening driver cover for easy maintenance, heat-resistant clear toughened glass and suitable optical system for uniform distribution of light, complete with LED module, LED driver and all necessary internal components, terminals, connectors. The work shall include taking down and removing the existing defective/obsolete light fitting of any make and condition, whether fixed in position on poles, high masts, buildings/structures or other supports, fixing the new LED light fitting on the existing suitable bracket/support, making necessary electrical connections, proper alignment and adjustment, testing for satisfactory illumination and ensuring proper and safe functioning of the complete fitting, complete in all respects as specified and directed by the Engineer-in-Charge.
Technical specification :-
(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range: Minus 10°C to Plus 50°C (d) Power factor: Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) | 100 | Each | 300 ₹30,000 Lowest | 3,850 ₹3,85,000 | 3,800 ₹3,80,000 | 4,000 ₹4,00,000 | 3,950 ₹3,95,000 | 4,420 ₹4,42,000 | 6,000 ₹6,00,000 | 4,000 ₹4,00,000 |
| 5.00 | Supply and fixing in replacement of energy-efficient LED wide-angle flood light fitting of 120 W capacity, complete with suitable LED driver, epoxy powder-coated pressure die-cast aluminium alloy housing/body and front cover of clear heat-resistant toughened glass, suitable for outdoor applications, including LED module, optical system, heat dissipation arrangement, terminals, connectors, gaskets and all necessary internal components and accessories. The work shall include taking down and removal of existing defective/unserviceable flood light fitting of any make and condition, wherever fixed, and fixing the new flood light on the existing suitable bracket/support, replacement of nut-bolts if required, including necessary electrical connections, proper alignment and adjustment for required wide-angle illumination, testing and commissioning, complete in all respects as specified and directed by the Engineer-in-Charge.
Technical specification :-
(a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : More than 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) | 30 | Each | 5,000 ₹1,50,000 Lowest | 10,500 ₹3,15,000 | 10,500 ₹3,15,000 | 11,500 ₹3,45,000 | 9,500 ₹2,85,000 | 9,520 ₹2,85,600 | 12,000 ₹3,60,000 | 11,000 ₹3,30,000 |
| 6.00 | Material and labour for electric connection of street light with and including by using two core (2x1.5sqmm) high-conductivity multistranded annealed copper (Class 5 flexible) flat/round cable, PVC insulated and overall PVC sheathed, 1100 volt Conforming to IS 694 : 2010, from junction box to light fitting drawn through existing protection pipe, including taking down old connection wire of any size and condition complete all as specified and as directed.
Note :- Protection pipe where required shall be measured and paid separately under appropriate item of BOQ. | 2,400 | RM | 100 ₹2,40,000 | 60 ₹1,44,000 | 60 ₹1,44,000 | 75 ₹1,80,000 | 65 ₹1,56,000 | 35 ₹84,000 Lowest | 65 ₹1,56,000 | 100 ₹2,40,000 |
| 7.00 | Supply and fixing in replacement security light fitting bracket made out of GI tubing light grade 50mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel/PCC pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. | 100 | Each | 500 ₹50,000 | 400 ₹40,000 | 400 ₹40,000 | 390 ₹39,000 | 350 ₹35,000 | 256 ₹25,600 Lowest | 500 ₹50,000 | 500 ₹50,000 |
| 8.00 | Supply and fixing in replacement security light fitting bracket made out of GI tubing light grade25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel/PCC pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. | 50 | Each | 350 ₹17,500 | 320 ₹16,000 Lowest | 320 ₹16,000 Lowest | 400 ₹20,000 | 325 ₹16,250 | 321 ₹16,050 | 1,000 ₹50,000 | 350 ₹17,500 |
| 9.00 | Material and labour for preparation and painting of existing steel tubular poles of any height upto 9 m, including all brackets, clamps, supports and other connected steel components of any description, by thoroughly cleaning the existing surface, removing dust, dirt, rust, loose/peeling paint and other loose particles using sandpaper, clean cloth, dry paint brush and other suitable means, and applying one coat of suitable aluminium paint over the entire exposed height of the pole, including brackets/clamps and connected steelwork. The work shall further include marking and painting of 5 Nos. alternate black and yellow strips, each 300 mm wide, from 1.50 m height above PCC coping, using one coat of suitable synthetic enamel paint in black and yellow colours and applying one coat cement-based paint to the exposed PCC pedestal surface,. The pole number shall also be marked in red synthetic enamel paint in letters and figures of not less than 100 mm height at a suitable visible location, complete in all respects as specified and directed by the Engineer-in-Charge. | 571 | Each Job | 1,050 ₹5,99,550 | 1,050 ₹5,99,550 | 1,050 ₹5,99,550 | 1,100 ₹6,28,100 | 950 ₹5,42,450 | 850 ₹4,85,350 | 800 ₹4,56,800 Lowest | 1,100 ₹6,28,100 |
| 10.00 | Material and labour for preparation and painting of existing PCC poles, including cleaning and preparation of the surface by removing dust, dirt by suitable means, and applying one coat cement-based paint to the exposed PCC pedestal surface, painting of the lower portion of the pole up to 1.50 m height above PCC coping with two coats of suitable synthetic enamel paint in alternate black and white strips, each strip being 300 mm wide, comprising 05 Nos. strips. The pole number shall also be marked in red synthetic enamel paint in letters and figures of not less than 100 mm height at a suitable visible location, complete in all respects as specified and directed by the Engineer-in-Charge. | 120 | Each Job | 425 ₹51,000 | 420 ₹50,400 | 420 ₹50,400 | 450 ₹54,000 | 450 ₹54,000 | 358 ₹42,960 Lowest | 500 ₹60,000 | 450 ₹54,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Sept 2026, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
REPAIR/MAINTENANCE OF SECURITY LIGHT AND CONNECTED ITEMS AT BHISIANA IN TECH AREA UNDER GE (AF) BHISIANA
2026_MES_786153_1
GE/BHI/TOKEN-34/2026-27
Open Tender
Civil Works
Item Rate
244 days
GE (AF) BHISIANA
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) BHISIANA
₹80,000
Yes
GE (AF) BHISIANA
15 Oct 2026
24 Aug 2026
16 Sept 2026
24 Aug 2026
14 Sept 2026
7 Sept 2026
24 Aug 2026 - 4 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for repair, maintenance and restoration of LED light fitting any wattage such as street lights, security lights, flood lights or any other type of external led light fitting, whether fixed in position on poles, high masts, buildings/structures or other supports, including carrying out the work in position or taking down the light fitting to ground level wherever required, inspection and testing of all components, parts, wiring and electrical connections, identification and rectification/replacement of defective components such as electronic drivers, connectors, terminals and other minor components, checking and tightening of loose connections, tightening of loose fitting, replacement of nut bolt, checking and rectification of incoming and outgoing wires at junction boxes, minor repair of wiring and connections, minor repair and maintenance of street light control timer, junction box and associated fittings, including refixing and securely restoring the light fitting to its original position after completion of repair, testing for proper functioning and illumination, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: (i) The quoted unit rate shall be deemed to include the cost of all labour, tools, tackles, lifting/access arrangements, taking down and refixing of light fittings, and all minor consumables and components, including electronic drivers, connectors, terminals, lugs, insulation tape and other incidental items required for completion of the work.
(ii) Only the repaired light fitting shall be measured and paid for under this item. No separate payment shall be admissible for inspection, checking, tightening of loose connections, tightening of fittings, or minor repairs carried out in junction boxes, timer/control boxes or other common control arrangements serving one or more light fittings, the cost of which shall be deemed to be included in the quoted unit rate.
(iii) In case replacement of an MCB is required, the same shall be measured and paid for separately under the relevant BOQ item. | 295 | Each job | - | - |
| 2 | Material and labour for repair, maintenance and restoration of light fitting other than LED any wattage such as street lights, security lights, whether fixed in position on poles, buildings/structures or other supports, including carrying out the work in position or taking down the light fitting to ground level wherever required, inspection and testing of all components, parts, wiring and electrical connections, identification and rectification/replacement of defective components such as choke (ballast), igniter, capacitor, lamp, lamp holder, connectors, terminals and other minor components, checking and tightening of loose connections, tightening of loose fitting, replacement of nut bolt, checking and rectification of incoming and outgoing wires at junction boxes, minor repair of wiring and connections, minor repair and maintenance of street light control timer, junction box and associated fittings, including refixing and securely restoring the light fitting to its original position after completion of repair, testing for proper functioning and illumination, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: (i) The quoted unit rate shall be deemed to include the cost of all labour, tools, tackles, lifting/access arrangements, taking down and refixing of light fittings, and all minor consumables and components, including choke (ballast), igniter, capacitor, lamp, lamp holder, connectors, terminals, lugs, insulation tape and other incidental items required for completion of the work.
(ii) Only the repaired light fitting shall be measured and paid for under this item. No separate payment shall be admissible for inspection, checking, tightening of loose connections, tightening of fittings, or minor repairs carried out in junction boxes, timer/control boxes or other common control arrangements serving one or more light fittings, the cost of which shall be deemed to be included in the quoted unit rate.
(iii) In case replacement of an MCB is required, the same shall be measured and paid for separately under the relevant BOQ item. | 5 | Each job | - | - |
| 3 | Supply and fixing in replacement of energy-efficient LED security light fitting/street light of 60 Watt, complete with pressure die-cast aluminium housing/body with top-opening driver cover for easy maintenance, heat-resistant clear toughened glass and suitable optical system for uniform distribution of light, complete with LED module, LED driver and all necessary internal components, terminals, connectors. The work shall include taking down and removing the existing defective/obsolete light fitting of any make and condition, whether fixed in position on poles, high masts, buildings/structures or other supports, fixing the new LED light fitting on the existing suitable bracket/support, making necessary electrical connections, proper alignment and adjustment, testing for satisfactory illumination and ensuring proper and safe functioning of the complete fitting, complete in all respects as specified and directed by the Engineer-in-Charge.
Technical specification :-
(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range: Minus 10°C to Plus 50°C (d) Power factor: Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) | 94 | Each | - | - |
| 4 | Supply and fixing in replacement of energy-efficient LED security light fitting/street light of 45 Watt, complete with pressure die-cast aluminium housing/body with top-opening driver cover for easy maintenance, heat-resistant clear toughened glass and suitable optical system for uniform distribution of light, complete with LED module, LED driver and all necessary internal components, terminals, connectors. The work shall include taking down and removing the existing defective/obsolete light fitting of any make and condition, whether fixed in position on poles, high masts, buildings/structures or other supports, fixing the new LED light fitting on the existing suitable bracket/support, making necessary electrical connections, proper alignment and adjustment, testing for satisfactory illumination and ensuring proper and safe functioning of the complete fitting, complete in all respects as specified and directed by the Engineer-in-Charge.
Technical specification :-
(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range: Minus 10°C to Plus 50°C (d) Power factor: Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) | 100 | Each | - | - |
| 5 | Supply and fixing in replacement of energy-efficient LED wide-angle flood light fitting of 120 W capacity, complete with suitable LED driver, epoxy powder-coated pressure die-cast aluminium alloy housing/body and front cover of clear heat-resistant toughened glass, suitable for outdoor applications, including LED module, optical system, heat dissipation arrangement, terminals, connectors, gaskets and all necessary internal components and accessories. The work shall include taking down and removal of existing defective/unserviceable flood light fitting of any make and condition, wherever fixed, and fixing the new flood light on the existing suitable bracket/support, replacement of nut-bolts if required, including necessary electrical connections, proper alignment and adjustment for required wide-angle illumination, testing and commissioning, complete in all respects as specified and directed by the Engineer-in-Charge.
Technical specification :-
(a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : More than 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) | 30 | Each | - | - |
| 6 | Material and labour for electric connection of street light with and including by using two core (2x1.5sqmm) high-conductivity multistranded annealed copper (Class 5 flexible) flat/round cable, PVC insulated and overall PVC sheathed, 1100 volt Conforming to IS 694 : 2010, from junction box to light fitting drawn through existing protection pipe, including taking down old connection wire of any size and condition complete all as specified and as directed.
Note :- Protection pipe where required shall be measured and paid separately under appropriate item of BOQ. | 2,400 | RM | - | - |
| 7 | Supply and fixing in replacement security light fitting bracket made out of GI tubing light grade 50mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel/PCC pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. | 100 | Each | - | - |
| 8 | Supply and fixing in replacement security light fitting bracket made out of GI tubing light grade25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel/PCC pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. | 50 | Each | - | - |
| 9 | Material and labour for preparation and painting of existing steel tubular poles of any height upto 9 m, including all brackets, clamps, supports and other connected steel components of any description, by thoroughly cleaning the existing surface, removing dust, dirt, rust, loose/peeling paint and other loose particles using sandpaper, clean cloth, dry paint brush and other suitable means, and applying one coat of suitable aluminium paint over the entire exposed height of the pole, including brackets/clamps and connected steelwork. The work shall further include marking and painting of 5 Nos. alternate black and yellow strips, each 300 mm wide, from 1.50 m height above PCC coping, using one coat of suitable synthetic enamel paint in black and yellow colours and applying one coat cement-based paint to the exposed PCC pedestal surface,. The pole number shall also be marked in red synthetic enamel paint in letters and figures of not less than 100 mm height at a suitable visible location, complete in all respects as specified and directed by the Engineer-in-Charge. | 571 | Each Job | - | - |
| 10 | Material and labour for preparation and painting of existing PCC poles, including cleaning and preparation of the surface by removing dust, dirt by suitable means, and applying one coat cement-based paint to the exposed PCC pedestal surface, painting of the lower portion of the pole up to 1.50 m height above PCC coping with two coats of suitable synthetic enamel paint in alternate black and white strips, each strip being 300 mm wide, comprising 05 Nos. strips. The pole number shall also be marked in red synthetic enamel paint in letters and figures of not less than 100 mm height at a suitable visible location, complete in all respects as specified and directed by the Engineer-in-Charge. | 120 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
BOQ_880959.xls
BOQ • 0.29 MB
TenderDocToken34.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .