Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹3.3 L+₹37,094 (12.5%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Tenderer | |
| 3 | L3₹4.0 L+₹1.1 L (35.9%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Tenderer | |
| 4 | L4₹5.5 L+₹2.5 L (84.2%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Tenderer | |
| 5 | L5₹6.2 L+₹3.3 L (109.9%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Tenderer |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
20 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE(I) CIF(R) C/O 56 APO
REPAIR/ MAINTENANCE OF INTERNAL ELECTRIFICATION AND CONNECTED WORKS AT HQ CIF(R) UNDER AGE(I) CIF (R)
2025_MES_704726_1
AGE(I)/R-10/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) CIF(R)
Class E and above and category b(i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹17,000
Yes
12 Jun 2025
19 Apr 2025
27 May 2025
19 Apr 2025
20 May 2025
5 May 2025
Amount
Taking down carefully copper/aluminium point wiring (light/Fan socket or power) with complete fittings such as switch, sockets Ceiling rose pendent holders regulators etc. Removing old/UNSV material from site and making good the old disturbed surface.
M&L for point wiring concealed type with PVC insulated unsheathed copper cable FRLSH 1.5 sqmm multi stranded two single copper conductor in and including suitable size PVC conduit pipe 20 mm dia complete with all accessories and with 1.5 sqmm PVC insulated copper cable FRLSH continous earth wire, re-recessed mounting pressed steel GI sheet box 2 mm thick suitable for modular switch/socket of adequate size including iner and outer white cover plate of modular complete all as specified and directed including making good the distrubed surface and matching with existing surfaces for followings :-
One light/fan point controlled by one way switch by one way switch 5 Amp 240 Volt
One three pin socket outlet 5 Amps independent board complete
One 3 pin 5 Amp socket out let on the same board with other switches with cables 1.5 sqmm
All as per item No 2 here in before but point wiring with 2.5 sqmm copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
S & F in replacement of modular switch single pole one way 6 Amps 1 module complete all as specified and directed
S & F in replacement of modular socket 6 A-2/3 pin combined 2 module complete all as specified and directed.
S & F in replacement of modular switch single pole one way 16 Amps 1 module complete all as specified and directed
S & F in replacement of modular socket 6 A/16 amp -3/5 pin combined 2 module complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor cable PVC insulated unsheathed cable 1100 volt grade enclosed and including PVC casing and capping with fittings and accessories fixed to walls/ceiling by means of PVC rowl plugs fasteners with cadmium plated screws all as per IS including hard wood board PVC board and 3mm thick laminated sheet top covers including 1.5 Sqmm copper PVC insulated unsheathed continuous earth wire and connected to common earth dolly for the following:-
One light/fan/5 ampsocket independent/bell point controlled by one switch 5 Amp.
One three pin socket outlet 5 Amps independent board complete
One 3 pin 5 Amp socket out let on the same board with other switches
All as per item No 8 here in before but point wiring with 2.5 sqmm copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
Supply and Fixing in replacement of switch piano, flush type single pole, one way 6 Amp, complete all as specified and directed.
Supply and Fixing in replacement of socket outlet 5 pin, 6 Amps flush type 230 volts AC, complete all as specified and directed.
Supply and Fixing in replacement of switch piano, flush type single pole, one way 15 Amp, complete all as specified and directed.
Supply and Fixing in replacement of socket outlet 2 in 1, 6 pin, 6/16 amp flush type, complete all as specified and directed.
S&F of ceiling rose, surface bakelite 65x50mm three terminals PVC/Polycarbonate complete all as specified and as directed
Material and labour in replacement PVC/polycarbonate lamp holder insulated body with back plate batten/angle type for batten fitting complete all as specified.
Supply and Fixing in replacement fan regulator modular, electronic step type heavy duty, 120 watt, 230 volts complete all as specified and as directed.
Supply and Fixing in replacement ultra modern recess mounting luminaire (yellow/white colour) with high performonging LEDs suitable for mounting with armstrong/grid ceiling of site 2' X 2' 34W and connecting up with three core copper conductor cable of suitable size, omplete all as specified and as directed. Make :Havells Cat Part No. Cat part No PLANO2X2PLR34WLED840S or equivalent cat part of make as specified in list of make here-in-after.
Supply and Fixing in replacement basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver wall mounted LED Batten 20 watt LED, extruded aluminium heat sink provided for effcient heat dissipation and integrated electronic driver, omplete all as specified and as directed. Make :Havells Cat Part No. Cat part No LUMILINEBS20WLED830SPCWH or equivalent cat part of make as specified in list of make here-in-after.
Supply and fixing in replacement LED Bulbs white /warm white (as per demand) in colour of 9/10 Watt,B-22 base Cap, complete all as specified and directed.
Supply and fixing in replacement of Modular bell push, flush type. 6 Amp 1 module, complete all as specified and directed.
Supply and fixing in replacement of bell push, flush type. 5 Amp, complete all as specified and directed.
Supply and fixing in replacement of basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver wall mounted LED batten 10 watt LED, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed.
Supply and fixing in replacement of sheet metal enclosure MCB distribution board SPN 12 way 240 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
Supply and fixing in replacement of sheet metal enclosure MCB distribution board SPN 8 way 240 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
Supply and fixing in replacement of sheet metal enclosure MCB distribution board SPN 4 way 240 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
Supply and fixing in replacement of sheet metal enclosure MCB distribution board TPN 4 way 240 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
Supply and fixing in replacement of MCB single pole 6 to 32 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 40 to 63 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply and fixing in replacement of MCB TPN 63 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed.
M&L in replacement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and one run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 6 sqmm cable and one run of 6.00 sqmm earth wire with PVC casing and caping shall be measured as one unit.
M&L in replacement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as one unit.
M&L in replacement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 2.5 Sq mm and one run of 2.5 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 2.5 sqmm cable and one run of 2.5 sqmm earth wire with PVC rigid conduit shall be measured as one unit.
S&F in replacement 1.5 Sqmm three core multi stranded copper conductor (FRLSH) cable PVC insulated unsheathed cable 1100 volt grade conforming to IS-694,complete all as specified.
S & F in replacement of LED lights 18 watt recess mounted square type size 185X185mm including connection with 1.5 sqmm PVC insulated copper wire, omplete all as specified and as directed. Make :Crompton Cat Part No. Cat part No LSDSSD-18-CDL/NW/WW or equivalent cat part of make as specified in list of make here-in-after.
S & F in replacement of LED lights 16 watt surface mounted round type size 205mm cut out dia including connection with 1.5 sqmm PVC insulated copper wire, omplete all as specified and as directed. Make :Crompton Cat Part No. Cat part No LSDMAGICRMN-16W or equivalent cat part of make as specified in list of make here-in-after.
S & F in replacement LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 22,417.00 during AOC Note:- Tenderers shall not quote for this Schedule
Rakesh Kumar Malia (BID ID -3294150)
M/s Chopra Constructions (BID ID -3296499)
MEELU ENTERPRISES (BID ID -3296393)
M/S PARSHOTAM KUMAR GUPTA (BID ID -3301295)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .