| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | ₹7.6 L Quoted ₹7.9 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹10.3 L+₹2.4 L (30.1%)Rejected-Finance H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | ₹10.3 L+₹2.4 L (30.1%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹11.4 L+₹3.4 L (43.0%)Rejected-Finance | ₹11.4 L+₹3.4 L (43.0%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹11.4 L+₹3.4 L (43.0%)Rejected-Finance | ₹11.4 L+₹3.4 L (43.0%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹12.4 L+₹4.4 L (55.8%)Rejected-Finance 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | ₹12.4 L+₹4.4 L (55.8%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
2 Dec 2023, 6:00 pmClosed
GE PANAJI
Garrison Engineer Panaji Opposite of Kala Academy St Inez Road Goa 403001
REPAIR TO INTERNAL ELECTRIFICATION INCLUDING FANS GEYSERS AND REWIRING TO CERTAIN BUILDINGS REPLACEMENT OF LED FITTINGS CONTROL DBS AND CONNECTED ITEMS AT MADGAON INCLUDING ASC AND PONDA UNDER GE PANAJI GOA
2023_MES_614063_3
8999/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE PANAJI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER PANAJI
₹24,000
Yes
6 Feb 2024
11 Nov 2023
5 Dec 2023
11 Nov 2023
2 Dec 2023
18 Nov 2023
11 Nov 2023 - 14 Nov 2023
Amount
Taking down carefully copper/ aluminum point wiring of light, fan, socket 5/15Amps or power point complete including fittings such as switches, ceiling rose, pendant, regulator, socket, lamp holders, brackets, lamp fittings, tube light fittings etc including switch boards and making good the disturbed surfaces of wall/ceiling/floors etc so as to match with the existing surface complete all as specified and as directed.
Taking down carefully sub main wiring including copper/ aluminum/ GI earth continuity conductor and making good the disturbed surfaces complete all as specified and directed.
Taking down main/ sub main MCB DB with MCBs of any size and capacity along with teakwood boards and including all fittings/furniture carefully and making good the disturbed surfaces complete all as specified and directed.
Material and labour for point wiring for one light point controlled by one way switch complete with 1100Volts grade 1.50 Sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable (Make: Anchor/ Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) and fixing on wall/ ceiling including PVC board with cover (ISI marked) for mounting switches, sockets, regulators etc and providing one run of 1.5 sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable as earth continuity wire and connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and directed.
All as in Item No. 4 above but for one ceiling fan point controlled by one switch
All as in Item No. 4 above but for one exhaust fan point controlled by one switch
All as in Item No. 4 above but for one bell point controlled by one switch
All as in Item No. 4 above but for one 5 Amp independent socket point controlled by one switch
All as in Item No. 4 above but for one 5 Amp socket point controlled by one switch on same board
Material and labour for point wiring for 15 Amp independent socket point controlled by one switch complete with 1100Volts grade 2.50 Sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable (Make: Anchor/ Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) and fixing on wall/ ceiling including PVC board with cover (ISI marked) for mounting switches, sockets, regulators etc and providing one run of 2.5 sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable as earth continuity wire and connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of paris/ putty complete all as specified and directed.
Supply and fix switch flush type, single pole, one way, 5Amps, 240 Volts, white finish complete all as specified and directed.
Supply and fix switch flush type 15/16Amps, 240 Volts, single pole white finish complete all as specified and directed.
Supply and fix bell push, 5Amps, 240 Volts white finish complete all as specified and directed.
Supply and fix socket outlet, 5 pin, 5Amps, flush type, white finish complete all as specified and directed.
Supply and fix socket outlet, 2 in1, 3 pin, 5/15Amps, flush type universal, 240 Volt, white finish complete all as specified and directed.
Supply and fix electronic socket size, rotary, 5 speed step type regulator, 220-230Volts, and white finish complete all as specified and directed.
Supply and fix call bell, ding dong type, AC 230 Volts single pole
Supply and fix ceiling rose, surface bakelite of size 65mm x 20mm three terminals complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate suitable for angle/ batten fitting complete all as specified and directed.
Supply and fix the SPN 4 way double door metallic sheet metal enclosure for DB when MCBs to be used 240 Volts with 200 Amps rated bus bar complete fixed properly on/ in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
All as in Item No. 20 above but for SPN 8 way
Supply and fix sheet metal enclosure double door, vertical type for DB’s when MCCB’s to be used triple pole and neutral 4 ways, 415 Volts with 200 Amps rated bus bar fixed sunk/ flush to wall complete all as specified and directed.
Supply and fix MCB SP 240 volts, 6 Amp to 32 Amp, 10 KA capacity having C-series connected with suitable lugs including testing and commissioning complete all as specified and as directed. Make: Havell's/ Schneider/ L&T
All as in Item No. 23 above but for SPN 16 to 32 Amps
Supply and fix MCCBs 415V, 16KA, 4 Pole, 63 Amp complete all as specified and directed.
Material and labour for sub main wiring with two single core PVC-FRLS insulated unsheathed stranded copper conductor cable of size 4 Sqmm (Make: Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including heavy duty PVC casing/ capping with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) with one single core PVC-FRLS insulated unsheathed stranded copper conductor cable of size 4 Sqmm as a continuous earth wire complete all as specified and directed. Note: Two single core cables and one run of earth copper conductor/ casing capping will be measured and paid as one unit length.
Material and labour for sub main wiring with two single core PVC-FRLS insulated unsheathed stranded copper conductor cable of size 6 Sqmm (Make: Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including heavy duty PVC casing/ capping with accessories (Make: Prestoplast/ Pressfit/ Finolex/ Precision) with one single core PVC-FRLS insulated unsheathed stranded copper conductor cable of size 6 Sqmm as a continuous earth wire complete all as specified and directed. Note: Two single core cables and one run of earth copper conductor/ casing capping will be measured and paid as one unit length.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below natural ground level) with top edge of the plate not less than 1.5metre below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to main switch board/ main DB’s/ earth test point with and including necessary excavation and earth work in any type of strata, PCC 1:3:6, type C1 in chamber wall with 50mm thick, RCC cover 1:2:4, type B0 duly reinforced with 6 mm dia bar, @100mm both way with suitable lifting handle, charcoal dust and common salt mixed and packed in 150mm thick layer all around the earth plate, watering pipe of size 20mm dia medium grade, 0.63mm thick GI sheet funnel with wire mesh, GI protection pipe 15mm dia light grade up to 7.5m from electrode and engraving of earth marking on nearby structure/ building with cement motor 1:4 plate of size 200mm x 150mm x 15mm thick complete all as shown in electrical plate No. 5 of SSR Part-I complete all as specified and as directed. Note: - On testing if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Material and labour for cutting/ boring of PCC hard standing at a depth not more than 15cm deep and 15cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC 1:2:4 type B-0 or cement mortar 1:3 complete all as specified and as directed.
Supply and fix GI pipe light grade of size 15 mm bore for laying in trenches/ floors or walls including all fittings as required complete all as specified and as directed.
Material and labour for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/ pipe all as required at site complete all as specified and as directed.
Supply and fix 20/22 W LED tube light fitting for surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver of 22 Watts LED luminaires of make Havell’s cat No LHEXBTP7IN1S022 or equivalent in Bajaj/Crompton/Wipro complete all as specified and directed.
Material and labour for bracket made out of GI pipe 25 mm dia medium grade, 0.6 metre long bent to shape fixed with MS flat iron clamps made out of 40mm x 6mm thick, nuts, bolts complete all as specified and directed.
Material and labour for 30 W LED street light fitting energy saving and environmental friendly long life LED light made up of pressure versatile die-cast aluminium housing with LED as lighting source of capacity 30 W LED 5700 K of make Havells ENDURAPEARLSL30WLED757SASYTOPCMP or equivalent in Crompton/Bajaj/Wipro complete all as specified and directed.
Disconnecting and taking down ceiling fan of any sweep any make from any position at site, transporting to MES store Yard and dismantling blades, opening the stator and rotor of ceiling fan and providing new lubricating grease in bearing/ bushes, re-assembling, commissioning and testing complete and rehanging/ re-fixing/ placing fan at same location at site including providing nuts, bolts, locking bolts, blade's screws, split pin, rubber real, PVC connector, washers etc. as required complete all as specified and directed. Note: - All major repairs such as replacement of bush, bearing, condenser, shaft, connection wire, winding & painting will be measured and paid separately under appropriate item of Schedule.
Disconnecting and taking down exhaust fan of any sweep any make from any position at site, transporting to MES store Yard and dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/ bushes, re-assembling, commissioning and testing complete and rehanging/ re-fixing/ placing fan at same location/ other location at site, including providing nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers etc., as required complete all as specified and directed. Note: - All major repairs such as replacement of bush, bearing, condenser, shaft, connection wire, winding and painting will be measured and paid separately under appropriate item of Schedule.
Removing of burnt winding from ceiling fan 1200/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire as per existing, providing insulating paper, varnishing and testing on completion, including transportation of fan to contractor's work shop and bringing back to store etc. complete all as specified and directed.
Removing of burnt winding from exhaust fan 300mm sweep and rewinding the same with equal gauge of super enameled copper winding wire as per existing, providing insulating paper, varnishing and testing on completion, including transportation of fan to contractor's work shop and bringing back to store etc. complete all as specified and directed.
Removing of burnt winding from exhaust fan 400/450mm sweep and rewinding the same with equal gauge of super enameled copper winding wire as per existing, providing insulating paper, varnishing and testing on completion, including transportation of fan to contractor's work shop and bringing back to store etc. complete all as specified and directed.
Material and labour for painting of ceiling fans/Exhaust fan of 1200/1400mm sweep by scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod as preparatory work for painting of ceiling fan and painting with one coat of supper enameled white paint with spray painting and writing of MES No. with capital letter of size 20mm height and 3mm width with synthetic enameled black paint complete all as specified and directed.
Supply and fix gun metal bush suitable for ceiling fan/ exhaust fan all as per site requirement including removing the old one complete all as specified and directed.
Supply and fix capacitor with PVC clamp of 2.5 MFD capacity suitable to fans including removing the old one complete all as specified and directed..
Supply and fix capacitor with PVC clamp of 4 MFD capacity suitable to fans including removing the old one complete all as specified and directed.
Material and labour ceiling fan/ exhaust fan/ wall fan shaft complete of size and quality as per existing in repairs complete all as specified and directed.
Supply and fix ball bearing of No 6201 Suitable to ceiling fans including removing the old one complete all as specified and directed.
Supply and fix ball bearing of No 6202 Suitable to ceiling fans including removing the old one complete all as specified and directed.
Supply and fix PVC insulated three core wire copper conductor 1100volt grade of size 0.5 Sqmm suitable to fan including removing the old one complete all as specified and directed.
Supply and fix PVC insulated three core wire copper conductor 1100 Volt grade of size 1 Sqmm suitable to fan including removing the old one complete all as specified and directed.
Taking down ceiling fan, remove the down rod and providing new down rod made out of GI tubing medium grade cutting, threading and drilling holes both ends (dual arrangement), making holes 02 Nos. painting with two coats of synthetic enamel white colour paint, fixing the down road to the fan and re-hanging the fan including electric connections complete all as specified and directed. Note: - GI down rod shall be measured and paid for separately under appropriate item of schedule as supply only.
Supply and fixing Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B-22 base make Havell’s cat No LHFOAJE1TN1I060 or equivalent in Bajaj/Crompton/Wipro including taking out old fitting of any type complete all as specified and directed.
Taking down carefully existing storage type water heater (Geysers) of any make and capacity (25/ 50 litres) including disconnecting water connection (inlet and outlet) for repairing/ painting etc and refixing the same and connecting up after cleaning, repairing and painting complete all as specified and directed.Note: (a) Defect developed while taking out the geysers, such as leaking of joints, damaging of thread of pipe/ geyser and other GI fittings such as elbow, nipple, union, socket, etc shall be rectified/ replaced by the contractor at his own cost. (b) Replacing the PVC connection, heating element, thermostat and painting work shall be measured and paid separately under relevant item of schedule.
Material and labour for scrapping the old painted surfaces of geyser, cleaning and painting with two coats of white synthetic enamel paint over a coat of red oxide primer including writing MES with black paint with minimum 25mm size of letters for 25 liters capacity geysers complete all as specified and directed.
Taking out geyser inner tank from geyser body, 25/ 50 liter capacity making the tank leak proof by necessary brazing/ welding work, repair to collar, testing for leakage and fixing back to the body with collar gasket complete all as specified and directed.
Supply and fix heating element push type 1.5 KW/ 2KW ISI Marked fixed in repairs including removing the old one complete all as specified and directed.
Supply and fix geyser thermostat of ISI marked, suitable for 20 degree to 80 degree centigrade in 25/50 liter capacity geyser fixed in repairs including removing the old one complete all as specified and directed.
Supply and fix safety valve, vertical type made out of brass chromium plated, size 15mm, heavy duty fixed in repairs including removing the old one complete all as specified and directed.
Supply and fix non return valve, vertical type, made out of brass suitable for 15 mm GI pipe including cutting and threading of G.I. pipe and G.I. fittings such as socket, union, elbow, nipple, etc. fixed in repairs including removing the old one complete all as specified and directed.
Supply and fix PVC connection hot water grade 450mm long 15 mm dia with two Nos. coupling nut of brass, heavy duty fixed in repairs including removing the old one complete all as specified and directed.
Supply and fix heavy duty water connection pipe (flexible steel) 450mm long and 15mm dia with two Nos. coupling nut of brass, heavy duty fixed in repairs including removing the old one complete all as specified and directed.
Supply and fix flexible copper wire 3 core PVC insulated and PVC sheathed size 2.5 Sqmm x 3core including removing the old one complete all as specified and directed. Make : Plaza/ Finolex/ Polycab
Supply and fix sheet metal single pole and neutral enclosure for 2 pole and earth metal plug and socket for incorporating 20 Amp SPN MCB with and including 20 Amp SPN MCB including removing the old one complete all as specified and directed.
Supply and fix glass wool for 25/ 50 litre capacity geyser by taking out inner and outer tank and reassembling complete all as specified and directed.
Taking down the existing Electric KWH meter's SP/TP upto 60 Amps from any position including disconnecting the all incoming/ outgoing electrical connection, and refixing the same in same or other location as specified including necessary misc items required at site complete all as specified and directed.
Supply and fix SMC box with hinge type fitting arrangement moulded in engineering plastic, including taking down old unserviceable cupboards complete all as specified and directed. Make : HPL/ Havell’s / Sintex
Supply and fix teak wood board, close recessed type 50mm deep, well-seasoned, polished and finished of size 30cm x 25cm covered with additional mica top fixed in position, including PCC cement work if required at site complete all as specified and directed.
Taking down old unserviceable, rusted sheet metal metering box in any location and any position after disconnection all electrical connections, MCB DB's and Electric meters carefully and stacking at site for re-use including making good the disturbed surfaces and M & L for new Sheet Metal Enclosure (Meter Box) fabricated out of 2.0 mm thick CRCA sheet, double door type with proper locking arrangement partially engraved in the wall, suitable for housing 5 Nos. single phase energy meters and 01 No SPN DB/VTPN DB and re-fixing the all energy meters and connected accessories including misc items required at site complete all as specified and as directed.
Taking down old unserviceable, rusted sheet metal metering box in any location and any position after disconnection all electrical connections, MCB DB's and Electric meters carefully and stacking at site for re-use including making good the disturbed surfaces and M & L for new Sheet Metal Enclosure (Meter Box) fabricated out of 2.0 mm thick CRCA sheet, double door type with proper locking arrangement partially engraved in the wall, suitable for housing 9 Nos. single phase energy meters and 01 No SPN DB/VTPN DB and re-fixing the all energy meters and connected accessories including misc items required at site complete all as specified and as directed.
Sagar Constructions
PREETI ENTERPRISES
Kedar Electricals
elite enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .