Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC VEENA SADAN PLOT NO 63 VARANGAON ROAD SUNDAR NAGAR BHUSAWAL 425201 | BHUSAWAL | JALGAON | MAHARASHTRA | 425201 | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹26.5 L+₹75,953 (2.95%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹29.7 L+₹3.9 L (15.2%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
23 Mar 2023, 6:00 pmClosed
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
SPECIAL REPAIRS TO 21 UNITS OF STAFF QUARTERS OF KV VARANGAON UNDER GE (S) AHMEDNAGAR
2023_MES_582950_1
8960/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Bhusawal
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹63,000
Yes
28 Mar 2023
25 Feb 2023
25 Mar 2023
25 Feb 2023
23 Mar 2023
9 Mar 2023
25 Feb 2023 - 2 Mar 2023
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
Taking down cement plaster on brick/ stone/ concrete wall including raking out joints, hacking for key scrubbing down with water etc all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames), area exc 1.50 sqm but n exc 4 sqm each and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and as directed.
Taking up or down 15mm bore existing steel tubing and connections complete all as specified and as directed
Taking up or down 20mm bore existing steel tubing and connections complete all as specified and as directed
Excavating in trenches, n exc 1.50m wide and n exc 1.50m in depth; for foundations, laying of pipes, cables etc. or for shafts, manholes, pits not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in any type of soil (Soft/loose/hard/dense) all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils all as specified and as directed
Removing excavated soil to distance exc 250m and not exc 500m and depositing where directed at a level not exc 1.50m above the starting point all as specified and as directed.
M&L for PCC, 1:4:8, type D2 using 40 mm graded stone aggregates as in foundations, filling and mass concrete all as specified and as directed
M&L for PCC, 1:3:6, type C2, using 40mm graded stone aggregates as in foundations, filling, mass concrete and surfacfe channel all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc.all as specified and as directed.
M&L for 25mm (Average) thick PCC 1:2:4, type B0, using 12.5mm graded stone aggregates for filling depressions of roof surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC, 1:2:4, type B1 using 20mm graded stone aggregates as in window or door cills, steps, string courses, copings, apex stones, bed plates, pintle blocks, etc. with plain fair faces including necessary formwork, chamfers, weatherings, throating etc. all as specified and as directed.
M&L for precast RCC, 1:2:4, type B-1, using 20mm graded stone aggregates as in landings, cover slabs (for manholes etc) and similar small articles including forms moulds, finishing with plain fair surfaces and set in cement mortar 1:4 all as specified and as directed. Note : Reinforcement will be measured and paid seperately.
M&L for brick work with sub class B bricks, old size, straight or curved on plan, exc 6m mean radius, built in cement mortar 1:6 all as specified and as directed.
M&L for brick work with sub class B bricks, old size, straight or curved on plan, exc 6m mean radius, built in cement mortar 1:4 all as specified and as directed.
M&L for cutting holes in brick walls built in cement mortar or cement lime mortar for inserting hold fasts, depth of embedded portion of hold fast exc half brick but not exc one brick and making good the dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperature 1.40 mm, fixed with stainless steel staples to steel / wooden frames, complete all as specified and as directed.
M&L for mild steel framed work such as grills grating etc with end of bars shoulderd and/or riveted .welded or forged into spikes.framedguard bars iron doors.ladders framed balusters , walk ways. railings, frame work of water tanks and similar work conforming to Fe 290 Gde E-165 all as specified and as directed.
S&F mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
S&F factory made steel windows with side hung shutter including box type hinges, steel handle and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F factory made steel windows with side hung shutter including box type hinges, steel handle and steel peg stay complete without glazing bars, complete all as specified and as directed.
M&L in repairs, for water proofing treatment to RCC roof slab, including parapet, comprising with the following treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish n exceeding 100 mtr distance from starting point. (ii) Screed bed or bedding layer of 10 mm thick cement mortar 1:4 with mixing of WPC @ 3% by weight of cement or as per manufacturers instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm. Note: Water proofing compount shall be measured & paid seperatly.
Supply only water proofing compound complete, ISI mark all as specified and as directed.
M&L for 75mm thick PCC 1:4:8, type D2, using 40mm graded stone aggregates as in sub base of flooring complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and any size confirming to IS 15658-2006 of 60mm thickness, M -35 grade with grey cement and pigment, laid over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; etc complete all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick surface/ concrete surfaces, finished even and fair complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortar 1:6 on other than fair faces of brick surface/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
S&F plain sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.50Sqm in each pane complete all as specified and as directed.
M&L for preparation new surfaces of walls and applying two coats exterior acrylic emulsion (weather coat) paint of any tint over a coat of exterior acrylic primer complete all as specified and as directed.
M&L for complete removal of existing treatment from walls including removing nails, making good holes and cracks etc brooming down or steel wire brushing, scrapping down and applying two coats of exterior acrylic emulsion paint of any tint over one coat of exterior acrylic primer on walls complete all as specified and as directed. Note : For item No 33 & 34 : The cost of scaffolding, safety measures etc shall deemed to be included in the unit rate quoted.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for 15 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings, concealed in wall or laid in floors etc complete all as specified and as directed.
Refixing old steel tubing 15mm bore, with and including provision of new fittings (connections) in new or old position (walls, ceiling, floors, etc), concealed in wall complete all as specified and as directed.
M&L for 20 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings, or laid in floors etc complete all as specified and as directed.
Refixing old steel tubing 20mm bore, with and including provision of new fittings (connections) in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 1000 litres capacity, tripple layered, hoisted and fixed in position and connecting including dismantling existing water tank all as specified and as directed.
S&F in repairs, ball valves high pressure PTMT with epoxy coated aluminium ball rod and high density plastic ball screwed for 20mm bore iron pipe (Minimum weight 210 gms) complete all as specified and as directed.
S&F in repairs, gate valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or unions and fixed to 20 mm bore pipe, complete all as specified and as directed.
S&F in repairs, 75mm dia, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls all as specified and as directed.
S&F in repairs, 75mm dia PVC (SWR) bends, any radius with access door all as specified and as directed.
S&F UPVC pipes 100mm dia for weep holes/ in boundary wall all as specified and as directed.
Bhirud Electric Stores
CHAUDHARY AND ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .