Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-Finance | L1 | Accepted-Finance Qualified as Rank L1 | |
| 2 | L2₹28.3 L+₹1.6 L (6.08%)Rejected-Finance C 5 156 YAMUNA VIHAR EAST DELHI DELHI 110053 | NORTH EAST DELHI | DELHI | 110053 | L2 | Rejected-Finance Rank L2 | |
| 3 | L3₹30.0 L+₹3.3 L (12.5%)Rejected-Finance | L3 | Rejected-Finance Rank L3 | |
| 4 | L4₹31.2 L+₹4.5 L (16.9%)Rejected-Finance | L4 | Rejected-Finance Rank L4 | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹28.8 L
EMD Value
₹57,696
Closing Date
2 Apr 2026, 3:00 pmClosed
Executive Engineer(E)
Executive Engineer (E), PWD HMED SW (NCTD), Ist floor, Samaj Sadan, DAP Lines, Vikas Puri, New Delhi
ARMO vrs E and M Services at DGD under SD-II, HMED SW, DDUH, New Delhi (SH SITC of Split Type Air Conditioner for vrs AAM Under Pradhan Mantri Ayushman Bharat Health Infrastructure Mission (PM-ABHIM)/ National Health Mission under phase IV)
2026_PWD_289261_1
163/EE(E)/PWD HMED SW/2025-26
Open Tender
Electrical Works
Works
60 days
South West
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹57,696
10 Apr 2026
25 Mar 2026
2 Apr 2026
25 Mar 2026
2 Apr 2026
25 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (outdoor ambient temperature). | |||||
| 1.01 | Inverter Type - Cooling only
1.5 TR with 5 Star BEE Rating | - | Each | - | - |
| 2SITC of Following Capacity Automatic Line Voltage Corrector wall mounted with digital display stabilizer having input voltage 140 to 280 volts & output voltage 220 ± 5% with TDR and Low & High Voltage Trip. i/c less credit of old dismantle material as where basis | |||||
| 2.01 | 4 KVA | - | Each | - | - |
| 3Providing and fixing powder coated Heavy Duty wall mounted stand for outdoor units of Split Air Condenser complete as required. | |||||
| 4SITC of hard drawn copper suction and discharge refrigeration pipe of size 5/8"and 3/8" suitable for 1.5 TR / 2 TR STAC duly insulated by nitrile rubber along with 3 core x 2.5 Sq.mm. copper cable & than inserted in the PVC flexible pipe with necessary support as required as per site requirement., testing i/c less credit of old dismantle material complete etc as reqd. | |||||
| 5Supplying and fixing of 25mm dia. medium class PVC drain Pipe on surface/ recess in the existing WTAC/ STAC at various locations of the hospital building etc. as required | |||||
| 6Supplying and laying of PVC insulated PVC Sheathed copper conductor cable of size 3 core x 4 sq mm copper flexible along with copper pipe or in air for connection indoor and outdoor unit etc. as reqd. | |||||
| 7Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. | |||||
| 8Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
BOQ_384133.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .