Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC 00 C O PARMOD SINGH BAKTA BARHI CHINTAMAN SITAMARHI BIHAR 843315 | SITAMARHI | BIHAR | 843315 | ₹16.3 L Quoted ₹16.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹16.9 L+₹10,113 (0.60%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | ₹16.9 L+₹10,113 (0.60%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹21.4 L+₹4.6 L (27.4%)Rejected-Finance B 17 SHRIRAM INDUSTRIAL ESTATE G D AMBEKAR ROAD WADALA MUMBAI CITY MAHARASHTRA 400031 | MUMBAI | MAHARASHTRA | 400031 | ₹21.4 L+₹4.6 L (27.4%) | L3 | Rejected-Finance BEING L3 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Apr 2022, 6:00 pmClosed
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR AND MAINTENANCE LT EXTERNAL ELECTRIC SUPPLY AND DISTRIBUTION SYSTEM AND REPAIR/ MAINT TO LT PANEL,APFC PANELS,FEEDER PILLAR BOX AND ALLIED WORKS AT AFS SITR R UNDER GE AF THANE
2022_MES_516091_1
8188/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹40,000
Yes
2 Jun 2022
31 Mar 2022
29 Apr 2022
31 Mar 2022
28 Apr 2022
16 Apr 2022
31 Mar 2022 - 16 Apr 2022
Amount
Disconnecting of LT supply and opening bus bar chamber / Cable box chamber of outdoor/ indoor LT kiosks / Panel , removing of burnt out lugs, MCB / isolators of any capcity/ size and cleaning of bus bar with CTC solutions, insulating the bus bar by taping with RYB colours, necessary nuts bolts of existing size and refixing after rapairs,complete all as specified and directed by Engineer in charge. (Note: Aluminium lugs of size and MCCB as mentioned below shall be measured and paid separately under relevent item of Sch A as supply only.)
Supply only aluminum lugs suitable for Cable of the following sizes:- Make : Denson/Raychem / M-Seal/ Birla-3M
Of size 10 Sqmm to 16 Sqmm
Of size 25 Sqmm.
Of size 35 Sqmm
Of size 50 Sqmm.
Of size 70 Sqmm.
Of size 95 Sqmm.
Of size 120 Sqmm.
Of size 150 Sqmm.
Cutting/Trimming of tree branched not exc 10 cm girth touching /approaching the LT/HT Over head line (having each span of 45 mtr) upto 3 mtr width on each side with cutting machine or manually to clear the LT/HT line including disposal of trimmed branches 100 mtrs away inside the cantonment area & cleaning site ,complete all as specified and directed by Engg-in-Charge. ( Note : All tools and plant required for cutting shall included in quoted rates)
S&F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying withrequirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in white and blue colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, struts & mass concrete including necessary form work and fair finishing to exposed surfaces complete all as specified and directed by Engineer-in-charge
M&L for preparation of old painted surfaces of PCC pole and applying two coats of synthetic enamel paint in blue and white colour in alternate strips of 30 cm each upto 1.50 metre height from top of PCC coping and applying two coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number with white synthetic enamel paint in 80mm high letters, over black synthetic enamel paint base of size 20cm x 20cm including applying two coats of white wash to coping of poles all as specified and directed by Engineer-in-Charge. Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces.
S&F in repair changeover switch & disconnectors 100 Amps,4Pole, 415 Volts, 50 Hz, Staggered terminals site convertible dual shaft position all as specified and directed.
Taking down Defective street light of LED of Capacity 25/30/60/90/120 W, flood light and bldg security light fitting of any type from their existing postion ie. Poles and bldg and re-fixing the same after carried out repairs ie. replecement of LED driver and SPD,PVC Wire etc all as specified and directed by Engr In Chrarge. Note: LED Driver,SPD and 3 core cable for replacement shall be measured and paid separatly under relevent item of Sch 'A' as supply only.
Supply only Surge protection device (SPD) of capacity 8 KV with phase ,neutral and earth wire in incoming and out going both sides ,complete all as specified and as directed by Engr-in-charge. Make: Bajaj/Havells/Crompton
Supply only Surge protection device (SPD) of capacity 5 KV with phase ,neutral and earth wire in incoming and out going both sides ,complete all as specified and as directed by Engr-in-charge. Make: Bajaj/Havells/Crompton
Supply only LED driver 30/45 W LED Street light Fitiing ,complete all as specified and as directed by Engr-in-charge. .Make: Bajaj/Havells/Shakti/C&S/CG/Plilips
Supply only LED driver 60 W LED Street light Fitiing ,complete all as specified and as directed by Engr-in-charge. Make: Bajaj/Havells/Shakti/C&S/CG/Plilips
Supply only LED driver 90 W LED Street light Fitiing complete all as specified and as directed.Make: Bajaj/Havells/Shakti/C&S/CG/Plilips
Supply only LED driver 120 W LED Street light Fitiing complete all as specified and as directed.Make: Bajaj/Havells/Shakti/C&S/CG/Plilips
Supply, fixing and testing LED Flood light fitting of 120 Watt in repair/replacement of existing high mast lights including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report .Make: Havells, helonix, C&S, Bajaj, philips, Wipro
All as per Item No 16 above but 200 Watt
All as per Item No 16 above but 150/160 Watt
Supply, fixing and testing LED street light fitting of 45 Watt in repair/replacement of existing high mast lights including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report .Make: Havells, helonix, C&S, Bajaj, philips, Wipro
All as per Item No19 above but 60 Watt
All as per Item No19 above but 90 Watt
All as per Item No 19 above but 120 Watt
Supply, fixing and testing Post top lantern of 25/45 Watt in repair/replacement of existing lights including LED lamps, acrylic, canopy totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report including suitable size of GI pipe for post with PCC 1:3:6 complete all as specified and as directed by the Engr- in- Charge. Make: Crompton, helonix, Havells, philips, C&S, Bajaj, Wipro, Shakti
M&L Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
M&L security light bracket made with GI pipe 40 mm dia light grade minium length 1.5 mtr long with 105 degree angle including necessary MS clamp made with 25mm x 6 mm and suitable MS studs and bolts, duly painted with two coats of aluminium paint over a coat of red oxide primer ,complete all as specified and as directed by the Engr- in- Charge. Rate - Including fixing clamp and anchor fasterner for GI Steel tubing.
Supply and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing ,complete all as specified and as directed by Engr-in-charge. .Make: Sintex/Hensel
M & L for connecting 1100 volt grade heavy duty cable PVC insulated copper conductor, served with inner sheathing of PVC tap and over all PVC sheathed in service connction for street light from FRP junction box to street light of size 3 core 1.5 Sqmm . ,complete all as specified and as directed by Engr-in-charge. Make: Paragon/HPL/Havells
Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB's.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMF panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage. (Notes :-This items includes the cost of cleaning & rewiring of panel. Spare parts required shall be measured and paid for separately under respective items as supply only)
Supply only in replacement of AIPFC microprocessor based relay 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge. Make- L&T/EPCOS/Siemens
Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of capacitor duty contactor 3 phase suitable upto 10 KVAR capacity duty contactor 1NO1NC 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T
Supply only in replacement of capacitor duty contactor 3 phase suitable upto 16 KVAR capacity duty contactor 1NO1NC 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T
Supply & fixing in repair of MCB 6 to 32 Amps, 3 Pole,10 KA coplete all as specified and directed by Enginner-in-Charge.
Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of current transformer of ratio 100/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement indictor lamp assembly LED type complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing Start/stop push button complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of digital type voltmeter 96 mm x96 mm, of range 0-500 Volts,Class-I complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of digital type ammeter 96 mm x96 mm, of range 0-200 Amps,Single Phase complete all as specified and as directed by Engineer-in-Charge.
M& L for preparation of existing painted surface of panel board/feeder pillar box (inddor/outdoor type), area not exeeding 10 Square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machine inclusive of wiriting SM/MES No/ Name of feeder etc (not exceeding of height 5 cm each) including welding of broken panel, tightening electric connection of switch gear and cleaning of vegetation all around the panels upto one meter from all sides complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement heavy duty TPN bus bar chamber 100 Amps,4 way fixed with hinges and locking arrangments for 4 Nos incoming/outgoing connection each bus bar fixed on wall complete all as specified and directed by Engineer-in-Charge. Make- Havells
M&L for fixing MS sheet 2mm thick to existing LT panels / feeder pillar box including necessary straightening /correcting the distorted parts, cuttings, welding / riveting,drilling bend to shape as required, welding of hinges, sliding door bolts, locking arrangement, nut, bolts, washers etc and appying two coats of synthetic enamedled paint over a coat of red oxide primer to match with the existing surfaces comlepte including butt hinges sliding door bolts and taping , thimbling disconnecting all incoming and outgoing complete all as specified and as directed by Engineer-in-charge. Note :- Supply only butt hinges and sliding door bolts shall be measured and paid seperately.
S&F in replacement 100mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
S&F in replacement 250mm long mild steel sliding door boltsclip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts,four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in-Charge.
Material and labour for carrying out repair/maintenance through manufacturer or authorised service center of Auto servo control voltage stabilizer 300KVA capacity located at HQ area . (i)Opening of stabilizer and maintanance of spare parts,fixing of new/repaired parts after repair in place of defective parts,repairing the defective control system etc and assembling complet all as specified and directed. (ii) Testing of stabilizer after repair on existing location to desired and rated output. Note:- All defective parts maint and cost of labour for maint is deem too be included in unit rate .
Supply Synchronising motor low speed instant start,stop high torque input voltage 250 Volt single phase 50HZ,60RPM type of following capacity ,Make:-AE,ME,Vintec
Supply Crontol relay AC 230 Volt, 250 ohms, 1 pin with base plate 24V DC. Make:-AE,ME,Vintec
Supply Gunmetal brush assembly for 100 KVA stabilizer.Make:-AE,ME,Vintec
Supply Variable voltage wound coil single phase.Make:-AE,ME,Vintec
M&L for hardcore of broken stone boulder, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
Providing and deployement of manpower for Cleaning and removing vegetation from electric substation and surrounding area with the helper of labour upto proper satifaction of Engineer-in-Charge complete all as specified and as directed. (Note -1. Each Jobs includes cleaning the area of 3 Nos of Substation & 2 DG sets Installation Approx total 1500 Sqm Area 2. Necessary tools, plant & safety equipments shall be arranged by the contractor in his own cost.)
Excavation in trenches, not exceeding 1.5m wide and n.exc 10 sqm on plan and n.exc 1.5m depth and getting out in hard/dense soil complete all as specified and as directed
Returning filling in including spreading levelling, watering & well ramming in layers not exceeding 25 cm in soil.complete all as specified and as directed.
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and as directed
Supply, spreading in trenches fine dry river sand for cable protection and removing down getting by hand complete all as specified and as directed
Supply and laying un reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and as directed.
Relaying un reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and as directed.
Taking out old unserviceable underground cable PVC insulated, PVC sheathed armored heavy duty aluminum conductor LT 1100 v grade, fixed on pole, wall and trenches etc after disconnecting of any size including cable cover complete all as specified and as directed
Supply & laying XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with aluminum conductor, 1100 V grade, of the following sizes: Make:Polycab/Havells/CCI/Gloster/KEI
(a) 2 core x 10 Sqmm
(b) 4 core x 16 Sqmm
(c) 3½ core x 25 Sqmm
(d) 3½ core x 35 Sqmm
(e) 3½ core x 50 Sqmm
(f) 3½ core x 70 Sqmm
(g) 3½ core x 185 Sqmm
(h) 3½ core x 240 Sqmm
M & L for Boring of road crossing in any kind of soil/rock strata , complete all as specified and directed by Engr-in-charge.
Supply & laying GI pipe light graded of size 40 mm dia in trenches and fixing on wall / pole with help of suitable size MS clamp for cable protection all as directed.
Supply & laying GI pipe light graded of size 80 mm dia in trenches and fixing on wall / pole with help of suitable size MS clamp for cable protection all as directed.
Supply & laying GI pipe light graded of size 50 mm dia in trenches and fixing on wall / pole with help of suitable size MS clamp for cable protection all as directed.
Saviour Security Systems
Urja Techniques India Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .