Directorate of Municipal Administration
Rajendra Kumar D R
9353478746
Construction of 6 MLD SBR Technology sewage treatment plant in Kallegowdanapallya in Tiptur CMC Limit
DMA/2025-26/OW/WORK_INDENT49383/CALL-2
DMA/2025-26/OW/WORK_INDENT49383/CALL-2
Open
Other Works
Two Tender Document System(Two Cover)
DMA City Municipal Council Tiptur
5 documents required · 5 mandatory
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
Work-done Certificate for having executed Similar Nature of work, total amount not less than 50 Percentage of amount put to the tender in last previous Five years in any of the Government/ Public Sector Undertaking
Should be valid Eligible Class registered Contractor in KPWD Civil Licence for Civil Work with in there registered jurisdiction
Liquid Assets and or Availability of Credit facility not less than 30 percentage of Amount put to the Tender Credit Lines Letter of Credits Certificates Unconditional from banks for Meeting the fund Requirement etc Usually 30 percentage of the amount of Contract with name of work or Indent number only
Annual Financial Turnover in the last 5 years period achieved in at least any two financial years an average annual financial turn over not less than the estimated cost With UIDN
GST Details, Income tax details PAN Card No issued by Income Tax Dept
₹1,590
₹1.5 L
9 Oct 2025
9 Oct 2025
27 Oct 2025
16 Oct 2025
Construction of 6 MLD SBR Technology sewage treatment plant in Kallegowdanapallya in Tiptur CMC Limit
Up gradation of SCADA System, Remote access of SCADA System ,DO and PH sensor for automatic regulation of aeration sequence /or rate of aeration , Integration of online continuous monitoring system of...
Ultrasonic Type Open Channel Rate of Flow at Edenhalli and Goraganhalli Wet Wells Measurement Type Non contact, Range 5m 10m 15m, Dead Band 350-500mm, Process Temp 20 to 70 C, Process Pressure -0.02...
Online Computerized Monitoring System
Real time calibration of BOD ,COD, TSS and Ph Value of inflow water and out flow water of STP
Nordac Decanter Driver Repair work
Frequency Inverter SK520E-151-340-O
Supply phases x Voltage (v) -3x400
PowerFI (kW) -1.500
HACH DO and Temperature Sensor LXV404.99.05502 None Digital Digital HART 100 - 240 VAC, no
Up gradation of Chlorination System Unit and Safety Equipment, Providing and Installation of Chlorinator Panels with 5kg pressure 2 nos , Necessary chlorine pipe line and valves.Safety devices Chlor...
Repair and Up gradation of Primary treatment unit and wet well Unit, Repair and Servicing of Mechanical Fine screen ,Grit Screw Unit, Grit Classifier Unit at STP
Repair and Servicing of Mechanical Course Screens Edenhalli and Goraganalli wet wells
Ultrasonic Type Open Channel Rate of Flow at Edenhalli and Goraganhalli Wet Wells Measurement Type: Non-contact Range 5m 10m 15m Dead Band 350 500mm, Process Temp 20 to 70 C, Process Pressure 0.02 to...
SBR Basins RAS and WAS pumps repair works , Pipe line works and Diffuser System and Aeration pipe line works , Aeration Motorized valve gates card replacement. And Inlet Motorized valve gates, RAS and...
Aeration Drop Pipe line replacement
Diffuser Membranes Other Pipe Line Works
Motorized Actuators Electronic cards
Make : Caira Euromatic Automation ,Model No : ATQ60-1 , Max Torque : 600 N M Rev: 1 r/min, Protection Level : IP 67, Power 3 Phase 415 v Model No : CS -300 Size- ...
Providing and Installation of Fire Fighting equipment in STP, Supplyandinstallationof9LtrFireExtinugisherAqueousFilm- FormingFoamType,StoredPressureType,PressureGauge,GrossWeight15.1Okg.emptyweight6.1...
SupplyingandinstallationofRUBBERMAT1mtrx1mtr-1Ommthick.completeincludingcostofmaterials,labour,usagechargesofmachinerycomplete as per specifications
Supplying of four bucket stand alongwith buckets. Complete
Installation of Solar System to offset energy requirements of STP, Supplying of Solar Panels of 5KVA with 4 Nos 150 AH Batteries with 6 Nos Solar Panels of 810 Wp
High Mast Pole 16 Mtrs Fabrication, Supplying, Erection, Testing and Commissioning of ...... ms long Polygon high mast with Single/Multiple telescopic sections having...
LT UG Cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-...
Laying of cable in Existing Trench/GI pipe/Stoneware/RCC Hume pipe using wooden/Aluminium Rollers as directed by departme...
Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130 1984 and Virgin PVC insulation sheathed suitable for work...
Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits depositing on bank upto a lead of 50 Mtr Supplying and Displaying necessary Danger Boards an...
Earth excavation
Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and su...
Base Concerete Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates...
Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Centering Work Centering, shuttering, formwork for foundation,sub structure of cross drainages. 5% of the finished concrete item rate
Providing and laying in position Reniforced cement concrete for all foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine ...
Rod Earthing 392) 51.04) Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal &...
Pothead Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up to 4C x 50 Sqmm
GI Pipe B - Class as per IS-1239 GI Pipe - 20 mm Dia
HDPE PLB Pipe 40/33 mm
MCB Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking...
LED Flood Lights 150 W Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with ...
MS Box For Street Lights Controling Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat diss...
Angle Frame Work Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of...
Hylum Sheet Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. Dimension 46x3...
Contactor Switch Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per...
Timer Switch Supplying and fixing Microprocessor based Electronic timer(without contactor, Din Mounting using necessary bolts, nutsand washers etc.,.) 3-120sec setting.
Fuse Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A
Wodden Board Supply and fixing polished wood board made of not less tha15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs scre...
Aluminium End Terminal (Lug) 25 Sqmm
Fixing charges Of Street Lights Fittings Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity w...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
EST.pdf
Others - Estimate • 0.78 MB
kw3 Jal Hi Amruth.doc
Tender Document • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].