GE (NW) NAVY NAGAR
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR, MAINTENANCE AND REPLACEMENT OF STEEL TUBULAR POLES, LIGHT BRACKETS, SOLAR STREET LIGHTS, JUNCTION BOXES, FEEDER PILLAR BOXES, AND OTHER ALLIED WORKS AT OLD AND NEW NAVY NAGAR UNDER GE(NW) NAVY NAGAR, COLABA, MUMBAI
2026_MES_788641_1
8675/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) NAVY NAGAR, COLABA
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
Yes
GE (NW) NAVY NAGAR
₹99,800
Yes
9 Sept 2026
9 Sept 2026
2 Oct 2026
9 Sept 2026
30 Sept 2026
23 Sept 2026
9 Sept 2026 - 30 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. | 25 | Each | - | - |
| 2 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 100 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. | 25 | Each | - | - |
| 3 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 100 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. | 18 | Each | - | - |
| 4 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. | 10 | Each | - | - |
| 5 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 100 lumens/Watt) min wattage 250 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. | 10 | Each | - | - |
| 6 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 100 lumens/Watt) min wattage 350 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. | 11 | Each | - | - |
| 7 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 100 lumens/Watt) min wattage 400 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. | 10 | Each | - | - |
| 8 | Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats of aluminium paint over a coat of red oxide primer all as directed incl dismantling old one .
NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item. | 30 | Each | - | - |
| 9 | Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) including two coats of aluminium paint over a coat of red oxide primer all as directed incl dismantling old one.
NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item. | 15 | Each | - | - |
| 10 | Supply, laying and commissioning, testing armoured heavy duty electric cable with copper conductor, 1100 volts grade of size 4 sqmm 4 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles/bottle lugs and taking out old u/s damaged cables. | 350 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
TENDERDOCUMENT.pdf
Tender Documents • 0.87 MB
BOQ_883992.xls
BOQ • 2.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .