Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC RATU RD PISKA MORE LAXMI NAGAR DISTT RANCHI JHARKHAND 834 005 | RANCHI | RANCHI | JHARKHAND | 834005 | L1 | Accepted-AOC The L1 bidder is techno-commercially eligible and the rate quoted is reasonable and justified, which has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹9.2 L+₹36,491.50 (4.12%)Rejected-Finance MAHAVIR NAGAR BUKBUKA KHALARI DISTT RANCHI JHARKHAND 829205 | RANCHI | JHARKHAND | 829205 | L2 | Rejected-Finance L2 |
Tender Value
₹8.1 L
EMD Value
₹10,200
Closing Date
14 Oct 2024, 5:00 pmClosed
SO EnM NK
GM OFFICE, NK AREA
(A) Repairing of primary control of FLP type 315 KVA, 3.3kV/550V TSU, Electrotechnika FLP Sl. No. 1053 installed at 40L/6MD (B) Repairing/ reconditioning of 04 No. VCB panel, 1250 A, Make Meditron 3.3kV installed at CRO Sub-stn in Churi Colliery.
2024_CCL_318360_1
GM (NK)/EnM/e-NIT/2024-25/ 166
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Churi Colliery
As per NIT
2 documents required · 2 mandatory
₹10,200
16 Jan 2025
30 Sept 2024
15 Oct 2024
30 Sept 2024
14 Oct 2024
30 Sept 2024
30 Sept 2024 - 5 Oct 2024
Amount
Primary control of FLP type 315 KVA, 3.3kV/550V TSU, Electrotechnika FLP Sl. No. 1053
Vaccum interruptor Type VL32597-13 400A 3.3kV
Epoxy Cast Drive Insulator for vi
Epoxy Cast Housing for vi
DMC moulded support insulator for isolator
Copper Galla connector
Copper Net Terminal
Labour charge for fixing of above spares includig ON-OFF Mechamism overhauling.
VCB Panel No. 6 Outgoing panel controlling TB2 UG
Auxilary switch 8NO+8NC
Numerical Over current and Earth Fault Relay 30/C & 1 E/F
Master trip Relay
Trip Neutral Close switch
Closing coil / Trip coil 110V dc
ON Off mechanism overhauling with required spares
Labour charges for fixing of Item Sl. No. 10 to 15
VCB Panel No. 4 Controlling Over head line UG 1250A
Ammeter (96 sqmm)
Volt meter (96 sqmm)
Test terminal Block
Closing coil 110V dc
Micro Processor Based Earth Leakage relay (300-12000mA) 100 MM dia CBCT
Indicating Lamp
Insulator complete set for VCB Panel
Vaccum Bottle 1250A-26KA
ON Off mechanism overhauling with required spares
Labour charges for fixing of Item Sl. No. 19 to 26
VCB Panel No. 3 Outgoing TSU 3.3kV/550V 1200A
Push Button with contact block
Indicating Lamp
Drive insulator
Busbar Spout
Circuit spout
Trip Neutral Close switch
Test terminal Block
Auxilary switch 2NO+2NC
Resin Cast Current Transformer 200/100/5A
ON Off mechanism overhauling with required spares
Labour charges for fixing of Item Sl. No. 30 to 38
VCB Panel No. 5 Attached with Capacitor Bank 1 & 2
Trip Neutral Close switch
Micro Processor Based Earth Leakage relay (300-12000mA) 100 MM dia CBCT
Numerical Over current and Earth Fault Relay 30/C & 1 E/F
Master trip Relay
Closing coil 110V dc
Ammeter (96 sqmm)
Under and over voltage relay
ON Off mechanism overhauling with required spares
Labour charges for fixing of Item Sl. No. 42 to 48
Total impact of GST for the purpose of CTC
M/S NIRAJ ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .