Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2 L
Closing Date
23 Dec 2021, 4:30 pmClosed
xen rew kathua
xen rew kathua
Repair of one Additional class room at MS Dhanu Parole kalan
2021_RDPR_153739_9
e-NIT No. 220 REW/K of 2021 Dated 17/12/2021
Open Tender
Civil Works
Item Rate
30 days
duggain
sbd
2 documents required · 2 mandatory
₹500
Yes
xen rew kathua
Exempted
1 Jan 2022
17 Dec 2021
24 Dec 2021
18 Dec 2021
23 Dec 2021
18 Dec 2021
Amount
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) (Including all leads and lifts carriages of material by MT/HL)
12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
15mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.(Including all leads and lifts carriages of material by MT/HL)
Providing and fixing strips in joints of terrazzo/ cement concrete floors. Glass strips 40 mm wide and 4 mm thick
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws Second class deodar wood 30mm thick
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).Second class deodar wood (30MM THICK SHUTTER)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 12 mm thick Marine plywood conforming to IS: 710
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
250mm x 10mm
100mm x 10mm
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Double rubber stopper
Providing and fixing oxidized M.S. casement stays (straight peg type) with necessary screws etc. complete of 300 mm weighing not less than 200 gms
Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 cement : 4 fine sand) L.M.R.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Refer CPWD DSR E&M 2018 Item No. 1.10.1).
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Refer CPWD DSR E&M 2018 Item No. 1.14).
2 x 2.5sqmm + 1 x 2.5 sqmm earth wire
Supply and fixing suitable GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16 A modular socket outlet 15/16 A modular switch connection etc as reqd
Suppling and fixing 5A to 32A rating, 240/415 V , 10 kA, "C" Curve , miniture circuit breaker suitable for inductive load of following poles in the existing MCB, DB complete with connection, testing and commissioning etc as reqd
Single Pole
Supply and fixing 9W LED lamp
Supply of ceiling fan 230V 50Hz with double ball bearing with low power consumption of following sweeps including fan regulators
1400mm ceiling fan
Supply and fixing of main service line 16sqmm twin core aluminium cable unarmoured from the LT pole upto the MCV/DB including connection etc as reqd
Supply and fixing following way single pole and neutral sheet steel MCB distribution board, 240V , on surface / recess complete with tinned copper bus bar neutral bus bar, earth bar interconnections power painted including earthing etc as reqd ( without MCB/RCCB/Isolators)
12 way, double door
Supply and fixing following modular switch / socket on the existing modular plate , and switch box including connections but excluding modular plate etc as reqd
5/6A switch
3Pin 5/6A socket outlet
Supply and fixing modular blanking plate on the exising modular plate and switch box excluding modular plate as reqd
Supplying and fixing suitable G.I. box with modular plate and cover in front on surface or in recess , including providing and fixingg 3 Pin 5/6 A modular socket outlet and 5/6A modular switch connection etc as reqd
Supplying and Fixing of following rating 240/10KA"C" curve , minature circuit breaker suitable for inductive load of following poles in the existing MCB/ DB complete with connections , testing and commissioning as reqd
Single pole and Neutral 63A
Providing and making CIB of approved size by way of making another layer of 12 mm thick plaster with 1:4 cement mortar on front side outer plastered surface, painting and writings as per the direction of engineer in-charge including supply of materials, carriages all complete. L.M.R.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .