Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC | L1 | Accepted-AOC Bid accepted being lowest tendrer | |
| 2 | L2₹26.7 L+₹2,397.31 (0.09%)Rejected-AOC | L2 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 3 | L3₹28.7 L+₹2.0 L (7.63%)Rejected-AOC VILL BUNGDAL DADHANI P O BADHANI DISTT PATHANKOT PIN 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 4 | L4₹31.0 L+₹4.3 L (16.2%)Rejected-AOC | L4 | Rejected-AOC Other than lowest tendrer hence rejected |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
16 Feb 2021, 6:00 pmClosed
CWE MAMUN
HQ CWE MAMUN PATHANKOT-145001
RENOVATION OF TOILET BLOCK , PROVN OF BADMINTON COURT AND WET CANTEEN IN KV NO IV UNDER GE (NORTH) MAMUN AT MAMUN MIL STATION
2021_MES_413638_1
CWE/M-79/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE NORTH MAMUN
Class D Category a I
5 documents required · 5 mandatory
₹500
GE NORTH MAMUN
₹56,000
Yes
12 Mar 2021
18 Jan 2021
17 Feb 2021
18 Jan 2021
16 Feb 2021
4 Feb 2021
Amount
Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out in any type of soil incl proper compaction complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cable/pipe etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, complete all as specified and directed.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
Spreading leveling in layer n exc 25 cm with soil well ramming with watering filling under floor complete all as specified and directed.(Note : Soil received from excavation shall be used for this purpose )
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in any type of soil , returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
M & L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and as directed.
M & L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
M & L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M & L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface with broken boulders or stone etc complete all as specified & directed.
M & L for Cement concrete (1:3:6)type C-2 (using 40mm graded aggregate) in foundations, filling and mass complete all as specified and directed.
M & L for cement concrete (1:3:6)type C-1 (using 20mm graded aggregate) as in window cill complete all as specified and directed.
M&L precast PCC solid block(1:2:4) type B-1 (using 20 mm graded stone agg) as in kerb stones of machine made setting in CM (1:6) etc complete all as specified and as directed.
M&L for PCC 1:5:10 type E2 using 40mm graded stone aggragate as in foundation filling and mass concrete (sunken floors etc) complete all as specified and directed.
M&L for Cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) such as in benching, coping, Bed blocks and the like, rounded or chamfered on edges including use and waste of necessary formwork including demolition of existing concrete of any description and removal of debris out off the premises etc complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates) in foundation fillings and mass concrete/ sub base, etc complete all as specified and directed.
Material and Labour for Plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregrate for for foundation of poles/stay and transformer including necessary form work complete all as specified complete all as specified and directed.
M & L for reinforced cement concrete M-25(Design Mix) with 20mm graded aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M & L for reinforced cement concrete M-25(Design Mix) with 20mm graded aggregate for columns, piers etc complete all as specified and directed.
M & L for reinforced cement concrete (Design Mix) of M-25 grade (20mm graded aggregates) for lintels over 1.5m span complete all as specified and directed.
M & L for reinforced cement concrete (Design Mix) of M-25 grade (20mm graded aggregates) as in chajja complete all as specified and directed.
M & L for reinforced cement concrete M-25(Design Mix) with 20mm graded aggregate for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position, complete all as specified and directed.
M&L for Precast cement concrete M-25(Design Mix) using 20mm graded crushed stone aggregate in cover slabs of manhole, drains & similar articles set in cement mortar 1:4 including demolition of existing cover slabs of any description and removal of rubbish out off the premises etc complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately)
Formwork as in fair finished flat surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork as square,rectangular or polygonal fair finished flat surfaces to side sides of pillars, posts, struts, piers, columns, and stanchions etc complete all as specified and directed.
Formwork to chajjas, troughs and similar items including edges fair finished flat surfaces concrete complete all as specified and directed.
Formwork fair finished flat concrete surfaces to sides and soffits of floor , lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) as rough finished flat surface of concrete complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. as fair finished flat concrete surface complete all as specified and as directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc 10cm but n exc 20cm wide fair finished surfaces of concrete complete all as specified and as directed.
M&L for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, fitted to chowkhats including preparation of surfaces of shutter and application of two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for stainless steel Butt hinges of size 100 mm fixed with steel screws of appropriate size complete all as specified and directed.
M&L for Aluminium anodised barrel tower bolt, extruded section 200mm long , complete all as specified and directed.
M&L for Aluminium anodised handle, extruded section of size 150mm complete all as specified and directed.
M&L for 250mm aluminium alloy sliding door bolt with hasp & staple (bolt type) and fixing clip of sheets cast or extruded section and fixing sliding bolt of extruded section complete all as specified and directed.
S&F 140 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S& F 150 mm size stainless steel bright finish handle as approved , fixed with Nut and bolt complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled stainless steel, of size 75 mm with galvanised mild steel hing pin etc complete all as specified and directed.
Taking down chowkats or frames of any description not exc 1.50 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware , complete all as specified and directed.
Taking down chowkats or frames of any description exc. 1.50 Sqm and n.exc 4.00 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware , complete all as specified and directed.
S&F Solid frame wooden high density filament(HDF) double rebated size 125x62 mm processed with polyyolefin's and different wood fiber, fixed to opening including necessary fixing lugs, hinges, lock strike plate etc all as specified. Make:- HR Enterprises, Polycon, Rajashree Plastiwood
S&F 35 mm thick HDF prelaminated(wenga/teak colour) moulded shutter 35 mm thick puf(poly ucrane form) insulation with minimum density 40 kg/cum filled in between two HDF sheets of thickness 3.2 mm both & border covered with 10 mm thick PVC sheet complete in all respect with lock rail & beautified by PVC bedding all around with PVC Solvent complete all as specified and as directed.
M & L for Soild PVC door frame wood grain color coated of size 50mm x 95mm made out of 5mm wood grain colour PVC sheet reinforced with MS Square tube , supply and fixing in opening as per specification & drawing complete all as specified and directed.
Supply and fix for factory made PVC door shutter 30mm thick (style) consisting of frame made out MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading incl 110 mm PVC door bend , and jointed together with solvent cement complete all as specified and as directed.
M&L for Mild steel powder coated door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate including necessary welding etc complete all as specified and directed.
M&L for Second class hard wood small fitting such as brackets of any type, latch & hinge blocks, shaped door & window stops & the like including all necessary labours; articles n exc 200cu.cm each, etc complete all as specified and directed.
M&L for Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staple complete all as specified and directed.
M&L for 3mm thick figured glass, pin head type, ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not exc 0.5sqm in each pane, etc complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per Srl item No 53 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed.
M&L for Aluminium powder coated frame for partition and doors/windows with one or more rebates using appropriate section not less than 1.50mm thick including joining cleat for fixing etc. complete all as specified and directed.
M&L for Aluminium powder coated window/ventilator shutters side hung type with sash bar, locking rails, locking arrangements including necessary joinery, jointing cleats, glazing clips, rubber packing, anodized aluminum snap beading, screws, suitable handle and glazing of 5mm thick ordinary sheet glass. Size of top rail, bottom rail shall be 44.45mmx44.45mm and size of frame shall be 65mmx44.45mm and thickness of aluminum section not less than 1.50mm thick complete all as specified in MES SSR-2009, Part-I complete all as specified and directed.
S & F guard bars for window guard bars, and similar articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S & F of flat iron fillets (for securing guard bars.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L for pressed steel frames 105mmx60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends incl 02 coats of synthetic enamel paint over a coat of red oxide primer on exposed surface complete all as specified and directed.
M&L for Mild steel work as in Misc. item such as pole for net of badminton court incl. 50 mm dia pulley with nuts etc.incl. cutting top to shape as directed incl cutting holes , notching for wire etc. flat iron for securing net etc & similar works using steel conforming to Fe 290 Gde E-165 and application of two coats of synthetic enamel paint over a coat of red oxide primer on exposed surface, including complete all as specified and directed.
M&L for Brick work with Fly Ash Brick (Non-Modular) Class 7.5, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
Dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc and removal of rubbish out off the premises, etc complete all as specified and directed.
M&L for brick work with Fly Ash Brick (Non-modular) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M&L for 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth including WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement ,complete all as specified and directed.
M&L for Rendering 15mm thick in two layers (base layer 10mm in cement mortar (1:6) & finishing layer 5mm thick in cement mortar (1:4) using liquid water proofing compound ( In 2nd Coat only)on brick work or concrete surfaces of wall surfaces finished even and smooth using extra cement complete all as specified & directed. (Note : WPC shall be measured and paid separately)
Supply only Polymer liquid water proofing compound of make Pidilite/Bauchemic/Fosrock, all as specified and directed.
Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement ,complete all as specified and as directed.
M&L for rendering 5mm thick cement plaster on surfaces of concrete ceiling in cement mortar (1:3), surface finished even and smooth without using extra cement, complete all as specified & directed.
M&L for Rendering 15mm thick on brick work or concrete surfaces in CM 1:4 with and including liquid water proofing compound to sunken portion finishing cement concrete surface even and smooth using extra cement including application of 90 micron polythene film and applying bitumen coating @ 3.00 Kg/Sqm (WPC shall measured and paid separately) complete all as specified and directed.
M&L for Rendering 10mm thick internal cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:3) finished even and smooth using extra cement with liquid water proofing compound complete all as specified and as directed. (Note : WPC shall be measured and paid separately)
M & L for 75mm thick Cement concrete type (1:3:6)type C-2 (using 40mm graded aggregate) as in sub base/base of floor complete all as specified & directed.
M & L for 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finished even and smooth using extra cement complete all as specified and as directed.
M&L for 50 mm thick cement concrete (1:2:4) using 20 mm graded crushed stone aggrgate finishing cement concrete surface even and smooth (without using extra cement) as in floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio (1:2) by weight complete all as specified and directed.
M&L for Vitrified ceramic coloured tiles light shade with rectified edges 10mm thick, area of each tile exc 0.18 Sqm but not exc. 0.38 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) (surface finished even and rough to receive vitrified tile) complete all as specified and directed.
M&L for Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc brushing neat cement slurry with 3.00 kg per sqm complete all as specified and directed.
M&L for Glazed ceramic (coloured) tiles 7mm thick, of size 450mmx300mm, 7mm thick on vertical surfaces such as dado etc, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match tiles over and including 10mm thick backing coat in cement mortar (1:3), surface finished even and rough to receive tiles, including dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises, etc complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges joints free tiles 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) including dismantling existing floor tiles of any type and pattern including cement mortar bedding and removing debris/tiles out off the premises, etc complete all as specified and directed.
M&L for 20mm thick Granite work (Telephone Black/ Lakha Red) (table rubbed and premirror polished) in single piece in steps, jambs, pillars, window-cills, cooking platforms ant the like set & jointed in neat cement slurry including pointing in epoxy grout to match with shade of granite, including making hole for gas pipe including rounding the edges of granite, laid over and including 15mm thick screed bed in CM 1:4 including roughening surfaces of existing concrete floor by picking, sweeping clean & washing down with water to remove dust and apply neat cement slurry @ 3.00kg of cement per sqm complete all as specified and directed.
M&L for 60mm thick factory made rubberised coloured (laminated) interlocking paver block (using vibro compaction method) (topping thickness not less than 5mm) in white cement and non fadable glossy pigment of approved shade of any shape and size conforming to IS-15658-2006 of M-35 grade laid over & including cleaned dry sand cushion 50mm thick over and including 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) including demolition of damaged cement concrete of any type or description and removal of debris out off the premises etc complete all as specified and directed.
S&F 3 mm thick plastic dividing strips(Width of the strip not less than 38 mm) as in flooring complete all as specified and directed.
S&F in repair for Stainless steel sink with draining board 1mm thick sheet for kitchen with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm and bowl size 405mm x 355mm x 178mm, including 32mm bore PVC waste outlet pipe of minimum length 600mm complete all as specified and directed. Make : Blue star Cat part No BSSBSD-52 or equivalent model in Nirali/Jyoti
M&L for 18 to 20mm thick prelaminated PVC solid board with acrylic lamination not less than 0.50mm thick (one side decorative choice laminate and other side balancing white) having weight not less than 9 Kg/Sqm and average density ranging from 500-700 Kg/Cum fixed as in kitchen cabinet, cupboard and pelmet box fixed with screws to PVC/timber frame work complete all as specified and directed.
All as per Srl item no 84 here in before but both sides white board without printed.
M&L for Preparation of newly plastered surfaces of wall & applying two coats of cement base paint over one coat of alkali primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of distemper oil emulsion (OBD) over a coat of cement wall primer (from same manufacturer of OBD) over a layer of wall care putty not less than 2mm thick complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and apply three coats of white wash on plastered surfaces complete all as specified and directed.
M&L for Preparation of exisiting cement base painted surfaces of wall applying two coats of cement base paint over a coat of primer as per manufacturer instructions complete all as specified and directed.
M&L for Preparation of new plastered surfaces of walls and apply three coats of white wash on plastered surfaces etc complete all as specified and directed.
M&L for Preparation of existing white washed surfaces of walls and apply two coats of white wash on plastered surfaces etc complete all as specified and directed.
M&L for Preparation of existing white washed surfaces of ceiling and apply two coats of white wash etc complete all as specified and directed.
M&L for Preparation of existing distempered surfaces of walls by complete removal of existing treatment and apply two coats of distemper oil emulsion (OBD) over a coat of cement wall primer (from same manufacturer of OBD) over a layer of wall care putty not less than 2mm thick etc complete all as specified and directed.
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane etc, complete all as specified and directed.
M&L for 12 mm thick toughened glass as in partition including itching,frosting and fixing arrangements with connectors as approved by GE. Make:- Modi Guard/ Saint Gobain/ Atul
M&L for Taking down existing surface/concealed water tubing 15mm bore and refixing in same/new location after cleaning and application of bituminous paint on concealed portion of tubing including cutting & threading pipe and provision of additional fittings such as socket, tee, elbow, union complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
M&L for Taking down existing surface/concealed water tubing 20mm bore and refixing in same/new location after cleaning and application of bituminous paint on concealed portion of tubing including cutting & threading pipe and provision of additional fittings such as socket, tee, elbow, union complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
M&L for GI water tubing surface/concealed, 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, including taking down existing unserviceable GI tubing and connections etc complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Refixing of old steel tubing 15 mm medium grade galvanized ISI marked with all fittings short pieces and fixed to walls, floor etc complete all as specified and as directed.
M&L for GI water tubing surface/concealed, 20mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, including taking down existing unserviceable GI tubing and connections etc complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Refixing of old steel tubing 15 mm medium grade galvanized ISI marked with all fittings short pieces and fixed to walls, floor etc complete all as specified and as directed.
Cutting chases not exceeding 10cm in width/girth for concealed water tubing or concealed conduit wiring etc and making good in cement mortar 1:3 to match existing surface etc complete all as specified and directed.
S&F GI Pipe 50 mm dia medium grade (in short length) as spout pipe laid in brick wall ,complete all as specified and directed.
Material and labour for preparation of new steel or iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Preparation of new or previously untreated cement surfaces of any description not other wise described in strip n exc 10 cm width or girth and applying two coat of plastic emulsion paint over a coat of cement primer complete all as specified and as directed.
S&F 15mm bore chromium plated angular stop cock with wall flange of cast copper alloy, fancy type, with capstan head, screwed both ends for iron pipe, fixed in repair etc complete all as specified and directed. Make : Jaquar Cat part No FLR-5053N or equivalent of Hindware/Marc.
S&F 15mm bore chromium plated angular stop cock with wall flange of cast copper alloy, fancy type, with capstan head, screwed both ends for iron pipe complete all as specified and directed. Make : Jaquar Cat part No FLR-5053N or equivalent of Hindware/Marc.
S&F 15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule etc complete all as specified and directed. Make : Jaquar Cat part No FLR-5047N or equivalent of Hindware/Marc.
S&F 20mm size gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed cast copper chromium plated fancy type alloy ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed.
S&F in repair 20mm size gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed cast copper chromium plated fancy type alloy ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed.
S&F 15mm bore Stop valves fancy type, chromium plated cast copper alloy long shank and exposed part kit with fitting sleeve, operarting lever & adjustable wall flange (concealed type) screwed both ends for iron pipe or for unions, fixed in repair etc complete all as specified and directed. Make : Jaquar Cat part No ALD-083 & FLR-5083NK or equivalent of Hindware/Marc.
S&F in repair for 15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair for Vitreous china wash hand basin, white, flat back, size 550x400mm (Make : Jaquar Cat part No CNS-WHT-801 or equivalent of Hindware/Parryware/Somany) including 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated (Make : Jaquar Cat part No CON-021KN or equivalent of Hindware/Marc.) brackets, CP waste coupling, 32mm bore PVC waste outlet pipe of min 600mm long, including cutting for and pinning in end of brackets complete all as specified and directed.
S&F Single towel rail brass chromium plated 600mm long fixed with chromium plated screw and PVC cleat fixed in repair etc complete all as specified and directed. Make : Cat part No AQN-7711 of Jaquar or equivalent of Hindware/Marc.
S&F Brass Chromium Plated shower rose with arms fancy type with swivel joints 75 mm face dia of appoved make and cat part for 15mm bore iron pipes fixed in repairs etc complete all as specified and directed. Make : Prayag Cat part No BS-73 or equivalent of Hindware/Marc.
S&F Glass shelf assembly 55cm long with brass chromium plated bracket guard and railing fixed with chromium plated screw and PVC cleat fixed in repair etc complete all as specified and directed. Make : Jaquar Cat part No AQN-7771 or equivalent of Hindware/Marc.
S&F in repair for stainless steel, Soap dish holder fixed with steel screw on walls, complete all as specified and directed. Make : Cat part No AQN-7731 of Jaquar or equivalent model in Hindware/Marc.
S&F Vitreous china white wash down water closet pan (pedestal pattern) with soft closing seat cover L bend, S-trap (Make : Jaquar Cat part No CNS-WHT-553SSL or equivalent of Hindware/Parryware/Somany) & hand shower (Health foucet) 8mm dia 1m long flex tube in chrome finish and wall hook with NRV (Back flow preventer) and connection to drain (or out going pipe) (Make : Jaquar Cat Part No ALD-577 or equivalent of Hindware/Parryware) and to flush pipe, antisyphonic pipe fixed in repair including dismantling exisiting water closet etc complete all as specified and directed.
S&F Vitreous china White Squatting Orissa Pattern pan (Make : Jaquar Cat part No CNS-WHT-451 or equivalent of Hindware/Parryware/Somany) of size 580x440mm, including cast iron ‘P’ or ‘S’ trap, front or back inlet and integral foot rests and making connection to trap and to flushing pipe, anti syphonic pipe, fixed in repair including dismantling existing squatting pan and making good to disturbed floor, etc complete all as specified and directed.
S&F Vitreous china ladies urinals of size 450x350x100 mm white with foot rests any pattern (excluding supply but incl fixing of flushing cistern and flushing pipe) incl provn of cement concrete bedding , in repair complete all as specified and as directed.
S&F PVC flushing cistern 10 Ltr capacity, valve-less symphonic action type, low level, complete with inlet, ball valve, handle, including brackets/pins, PVC flush pipe 32mm bore and PVC connection 15mm bore 450mm long, including taking out existing high/low cistern, etc complete all as specified and directed.
S&F Vitreous china Urinal, Half stall type (Make : Jaquar Cat part No URS-WHT-13261 or equivalent of Hindware/Parryware) white including PVC waste pipe, PVC spreader, CP grating, providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plug with and including 60mm long brass screw, pointing around urinal back in coloured epoxy grout to match etc complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. Make:Paryag/Polytech
S&F 100 mm bore, cast iron bends (any radius), diminishing pieces or tapers (large bore measured) without oval access door, fixed in repair complete all as specified and directed.
S&F 75 mm bore, cast iron bends (any radius), diminishing pieces or tapers (large bore measured) , fixed in repair complete all as specified and directed.
S&F 100 mm bore, cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door, fixed in repair complete all as specified and directed.
S&F 75 mm bore, cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door, fixed in repair complete all as specified and directed.
S& F run lead joint for 75 mm dia CI pipe complete all as specified and directed.
S& F run lead joint for 100 mm dia CI pipe complete all as specified and directed.
M&L for 100 mm bore, cast iron branch pieces or Tee, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors, fixed in repair complete all as specified and directed.
M&L for 75 mm bore, cast iron branch pieces or Tee, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors, fixed in repair complete all as specified and directed.
M&L for 100 mm bore, sand cast, cast iron vent pipe with cement joints, in any length with ears, fixed to wall with stack clamp made out of 25mm by 3 mm galvanised flat iron fixed with bolt and nuts, fixed in repair complete all as specified and directed.
M&L for 75 mm bore, sand cast, cast iron vent pipe with cement joints, in any length with ears, fixed to wall with stack clamp made out of 25mm by 3 mm galvanised flat iron fixed with bolt and nuts, fixed in repair complete all as specified and directed.
M&L for 50 mm bore, sand cast, cast iron vent pipe with cement joints, in any length with ears, fixed to wall with stack clamp made out of 25mm by 3 mm galvanised flat iron fixed with bolt and nuts, fixed in repair complete all as specified and directed.
M&L for 100 mm bore, sand cast, cast iron soil pipe with cement joints, in any length without ears, laid in floor or trenches, fixed in repair complete all as specified and directed.
M&L for 75 mm bore, sand cast, cast iron waste pipe with cement joints, in any length without ears, laid in floor or trenches, fixed in repair complete all as specified and directed.
M&L for 50 mm Cast iron cowl, fixed with cement joints fixed in repair complete all as specified and directed.
S&F 75 mm Cast iron floor trap, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) in repair including taking down existing CI floor trap, complete all as specified and directed.
S&F 75 mm Cast iron floor trap, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Dismantling cast iron work of any description and position complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm bore , single socketed, in any length with rubber joints , in any length fixed to wall complete all as specified and as directed.
S&F PVC (SWR) rain water pipes of 110mm bore dia in any length, with rubber ring joints, fixed to walls with stack clamp made out of 25mm by 3 mm galvanised iron flat fixed with bolt and nuts, including taking down existing CI/SWR pipes etc complete all as specified & directed.
S&F in repair for PVC(SWR) bend any radius 110 mm dia bore complete all as specified and directed.
Dismantling brick tile or terracing tiles single layer on roof Complete all as spd and directed
M & L for brick tiles laid on cement mortar in CM 1:4 and joints grouted and flush pointed in CM(1:3) and mixed with 5 % of crude oil by weight of cement,complete all as specified and directed.
M & L for brick tiles laid on cement mortar in CM 1:4 and joints grouted and flush pointed in CM(1:3) and mixed with 5 % of crude oil by weight of cement but except brick tiles, complete all as specified and directed
M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
M&L for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.
M&L for PCC 1:2:4 type B-0 padding as roof, surface finished even and smooth without using extra cement,complete all as specified and directed.
S&F (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified & directed.
Disconnecting existing tank etc 500 ltr& n exc 1000 ltr ,setting aside(or lowering if required) for repair,cleaning etc and hoisting if required reconnecting and refixing in position including cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes etc complete all as specified and directed.
S&F in repair Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball etc complete including taking out existing water tanks of any description all as specified & directed.
S&F Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball etc complete all as specified and directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc complete all as specified and directed.
Material and labour for Plain Cement Concrete (1:3:6) Type C-2 (using 40 mm graded broken stone aggregate) as in bed to drain pipe including forming cradles against the sides of pipes with concrete after they are laid and tested in 150 mm dia pipe complete all as specified and directed.
M&L for 150mm bore Reinforced concrete pipes with collar, Class NP2 laid with collar per length of pipe, jointed and tested etc complete all as specified and directed. (Note : Excavation, Earthwork and PCC for bed shall be measured and paid separately.)
M&L for Cutting into existing manholes for connecting new drains 150mm bore pipe including removing existing branch drain pipes of 200/150mm bore & benching to form branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) surface finished and reforming of benching as required including making good surface with cement mortar 1:3 to match existing, etc complete all as specified and directed.
Taking down carefully unserviciable/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /skh fitting ) and removing material from site and making good to the disturbed surface to match with existing finish complete all as specified and directed.
M&L for Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point complete all as specified and directed. (Note : Switch/bell push/fan regulator shall be measured and paid separately)
All as per Srl item No. 160 above but for 5 pin 5 Amp socket outlet point on independent board controlled by one switch 5Amp one way, complete all as specified and directed.
All as per Srl item No. 160 above but for 5 Pin 5 Amp socket outlet point controlled by one switch 5 Amps one way on same board, complete all as specified and directed.
All as per Srl item No. 160 above but for one 15Amp socket outlet point concealed using 2.5Sqmm FRLS PVC insulated multi-strand copper conductor wire including 1.5Sqmm FRLS PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall floor to match existing finishes complete all as specified and directed.
S&F modular socket 5 Amp, 2/3 Pin multipurpose, 2 module, complete all as specified and directed Make : Legrand/Crab Tree/ /GM/Havells/IndoAsian
Supply and Fixing modular switch one way 6 Amp one module, front operated complete all as specified and directed. Make: Legrand/Crab Tree/ /GM/Havells/IndoAsian
Supply and Fixing modular switch piano type flush button single pole 16 Amp one module, front operated complete all as specified and directed.Make: Legrand/Crab Tree/ /GM/Havells/IndoAsian
S&F socket modular socket 6 Amp/16 Amp, 2/3 Pin multipurpose, 2 module, complete all as specified and directed. Make: Legrand/CrabTree/ /GM/Havells/IndoAsian
S&F Ceiling rose polycarbonate isolated body surface Bakelite, not less than 65 x 50 mm, three terminals, AC 230 volts etc, complete all as specified and directed. Make : Havells Cat Part No Reo/Cona Cat Part No 9246/GM Cat Part No 8224
S & F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as specified and directed.
S & F white powder coated CRCA box with decorative end cap batten alongwith LED T8 tubular lamp 20W linear with extruded aluminium/pc body and PC diffuser and inbuilt driver, 230 volts wall mounted complete with all accesssories internally pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement Energy saving, surface mounted, bulk head LED luminaire 10 W Made of pressure die cast aluminium housing with IP 65 protection complete including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F Lamp holder insulated body with back plate suitable for batten fitting including B22 type, 12W LED lamp of approved make and cat part and PVC Round/Square block etc complete all as specifeid and directed. Notes for Srl item No 170 to 172 :- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 50,000 burning hours LED life from NABL lab shall be povided. 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 11. CA No shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
S&F in replacement sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit of dia not less than 20mm and 1.8mm thick including all accessories complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface complete all as specifeid and directed.. Make : Anchor/GM/Finolex/RR Kablel/Grandlay
S & F in replacement SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with 200Amps rated copper bus bar complete all as specified and directed.Make- Legrand/Hager/Schnider
S & F in replacement SPN MCB DB 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC with 200Amps rated copper bus bar complete all as specified and directed.Make- Legrand/Hager/Schnider
S&F MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) of approved make complete all as specified and directed.
S&F in replacement MCB SPN 240V, 50Hz, 10 KA,of rating 32Amps complete all as specified and directed. Make- Legrand/Hager/Schneider
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 10 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
M & L for sand cushioning in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. [Note : Punned thickness shall be measured and paid]
M & L for well burnt bricks , laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.
Material and Labour for pre cast cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregrate for coping of poles/stay complete all as specified complete all as specified and directed.
M&L for GI tubing light grade 40mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, HDPE pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
Supply and fixing 5 star rated ceiling fan 230 volts,single phase of 1200mm sweep double bearing type including down rod, canopy cover etc and connecting with 3core flexible copper conductor of 0.50 sq mm and including writing of MES No with black enamelled paint as per directed by engr-in-Charge. Make-Havells/Khaitan/Crompton/Orient
S&F Heavy duty Exhaust fan, single phase, 220 Volts, 50 Hz, 1400RPM, 300mm sweep with louvers including cutting round opening, through one brick thick masonry wall suitable for exhaust fan by providing, fixing and removing shoring, forming jambs with CM 1:3 and making good disturbed surface to match existing finish and removal of rubbish out off the premises etc complete all as specified and directed. Make : Crompton Model No EXHD300-4-1 or equivalent model of Bajaj/Havells
S&F ventilating fan AC single phase 230/240 Volts of size 250mm sweep with louvre of non metallic body with grouting nut bolts and making the suitable hole for 250mm sweep exhaust fan by breaking the existing wall and making good the disturbed surface by plastering and matching with existing specifications complete all as specified and directed. Make: Havells, Crompton, Orient
Supply, fixing, testing & commisioning of LED based Flood light, housing made up of pressure die cast aluminium with effective thermal management, sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 11000 lumens and maximum system wattage of 100 Watt. The fixture shall have a CRI of minimum 70; SDCM<5; Color temperature should be of 5700K. The fixture shall be designed for a system life of 50,000 hours @L70B50. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK07. The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=4KV, PF >0.9 and THD<10%. The fixture should comply with the parameters as per IS10322. The LED driver should have Fixed output, High Cut @325V , capable to withstand 440V for 8 Hrs and auto restart feature. Driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. The Luminaires shall be aesthetically appealing and should have no extrenal visible fins. LED's, driver and fixture should be BIS approved including 40mm dia GI pipe or 40 x 40 x 5mm angle iron bracket of suitable size duly welded on pole and light fitting to be fixed by means of clamps, nuts bolts of suitable size and making connections with DB with and including PVC insulated & sheathed single core cable of size 1.5 Sqmm 3 run for phase, earth,neutral complete all as spd and directed. Make of LED light fitting:- Philips /Osram/ Bajaj/ Wipro
Material and labour for errection of GI tubing medium grade of 100mm dia for mounting flood lights with covering top end with suitable size of MS sheet by welding and grinding for suraface finish incl painting black with two coat of synthetic enamal paint after one coat of red oxide complete al as specified and directed. Make: Jindal, Prayag, Prakaash Note : Earth work & PCC work will be measured and paid separately under relevant items.
M&L for Distribution cum junction Box 4.5 Module of size not less than 126 x 228 x 111, KV PC including 02Nos MCB SP 10 Amp with IP 65 protection incl mounting on pole with suitable clamps,nuts and bolts complete all as specified and directed.
M/S NARESH KUMAR SHARMA
M/S CANTILEVER ENGINEERS
jagdish sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .