Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 Sept 2026, 6:00 pm
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR C/o 56 APO PIN-937208
REPAIR/MAINT TO LT PANEL BOARDS AND CONNECTED ITEMS UNDER GE (AF) AWANTIPUR
2026_MES_785340_1
GE (AF) AWA-32/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) AWANTIPUR
₹90,000
Yes
20 Aug 2026
20 Aug 2026
12 Sept 2026
20 Aug 2026
10 Sept 2026
3 Sept 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE (AF), 8FBSU,AF
Name of Work: REPAIR/MAINT OF LT PANEL BOARDS AND CONNECTED ITEMS UNDER GE (AF) AWANTIPUR
Contract No: GE (AF) AWA-32/2026-27
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Supply, installation, testing & commissioning in replacement of factory made (CPRI test certified manufacturer) LT feeder pillar box of suitable size, outdoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 Volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 800 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 3 mm (outer) & 2 mm (inner compartment door) CRCA sheet duly powder coated, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs grouted in PCC. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The scope of the work also includes supply and fixing the following:- Note: The rate of PCC on which panel is grouted is deemed to be included in quoted rate by the contractor. 2 Each 0 Excess(+) Full Conversion INR
INCOMING:- (a) MCCB 400 Amps, 36 kA rupturing capacity, 4 Pole, 415 Volts, 50 Hz- 01 No. (b ) Voltmeter digital type 0-500 Volts -01 No (c) Ammeter digital type 0-800 Amps- 01 No (d) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a) MCCB 250 A Amps, 36 kA rupturing capacity, 4 Pole,415 Volts, 50 Hz AC - 01 No (b) MCCB 200 Amps, 36 kA rupturing capacity, 4 Pole, 415 Volts, 50 Hz AC - 01 No. (c) MCCB 160 Amps, 36 kA rupturing capacity,4 Pole, 415 Volts, 50 Hz AC - 01 No (d) MCCB 100 Amps, 25 kA rupturing capacity,4 Pole, 415 Volts, 50 Hz AC - 02 No
Supply, installation, testing & commissioning in replacement of factory made (CPRI test certified manufacturer) LT feeder pillar box of suitable, outdoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 Volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 800 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 3 mm (outer) & 2 mm (inner compartment door) CRCA sheet duly powder coated, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs grouted in PCC. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The scope of the work also includes supply and fixing the following:- Note: The rate of PCC on which panel is grouted is deemed to be included in quoted rate by the contractor. 2 Each 64 Full Conversion INR
INCOMING:- (a) Automatic Transfer Switch 400 Amps 4 pole motorized with inbuilt controller. (b ) Voltmeter digital type 0-500 Volts, flush type with 3 way rotary selector switch -01 No (c) Ammeter digital type 0-100 Amps, flush type with 3 way rotary selector switch and 3 Nos CTs of ratio 100/5 Amps - 01 No (d) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a) MCCB 250 Amps, 36 kA rupturing capacity, 4 pole, 415 Volts, 50 Hz AC, -03 No. (b) MCCB 100 Amps, 25 kA rupturing capacity, 4 pole, 415 Volts, 50 Hz AC, 03 No.
Supply, installation, testing & commissioning in replacement of factory made (CPRI test certified manufacturer) LT feeder pillar box of suitable size, outdoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 800 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 3 mm (outer) & 2 mm (inner compartment door) CRCA sheet duly powder coated, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs grouted in PCC. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The scope of the work also includes supply and fixing the following:- Note: The rate of PCC on which panel is grouted is deemed to be included in quoted rate by the contractor. 2 Each 64 Full Conversion INR
INCOMING:- (a) ACB 630 Amps 50 kA 4 pole electrically draw out type-01 Nos (b ) Voltmeter digital type 0-500 Volts, -01 No (c) Ammeter digital type 0-100 Amps, 01 No (d) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a) MCCB 250 Amps, 25 kA rupturing capacity , 4 pole, 415 Volts, 50 Hz AC, - 02 No. (b) MCCB 200 Amps, 25 kA rupturing capacity , 4 pole, 415 Volts, 50 Hz AC, - 03 No. (c) MCCB 160 Amps, 36 kA rupturing capacity,4 pole, 415 Volts, 50 Hz AC, - 01 No. (d) MCCB 100 Amps, 25 kA rupturing capacity, 4 pole, 415 Volts, 50 Hz AC 02 No.
Supply, installation, testing & commissioning in replacement of factory made (CPRI test certified manufacturer) LT feeder pillar box of suitable, outdoor type, floor mounted, double door, cubical compartmentalized type suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 315 Amps rating (100% neutral) installed on porcelain insulators. The panel shall be dust and vermin proof made of 3 mm (outer) & 2 mm (inner compartment door) CRCA sheet duly powder coated, panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs grouted in PCC. Front & back opening type with aprons for cable entry with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling and cable entry boxes with cable glands. The scope of the work also includes supply and fixing the following:- Note: The rate of PCC on which panel is grouted is deemed to be included in quoted rate by the contractor. 2 Each 64 Full Conversion INR
INCOMING:- (a) ACB 630 Amps 50 kA 4 pole electrically draw out type-01 Nos (b ) Voltmeter digital type 0-500 Volts, flush type with 3 way rotary selector switch -01 No (c) Ammeter digital type 0-100 Amps, flush type with 3 way rotary selector switch and 3 Nos CTs of ratio 100/5 Amps - 01 No (d) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a) MCCB 250 Amps, 25 kA rupturing capacity Ics=100%Icu, 4 pole, 415 Volts, 50 Hz AC, Adjustable thermal Fixed magnetic release type, connected through solid busbar of suitable size in both incoming & outgoing side - 02 No. (b) MCCB 200 Amps, 25 kA rupturing capacity Ics=100%Icu, 4 pole, 415 Volts, 50 Hz AC, Adjustable thermal Fixed magnetic release type, connected through solid busbar of suitable size in both incoming & outgoing side - 03 No. (c) MCCB 160 Amps, 36 kA rupturing capacity, Ics=100%Icu 4 pole, 415 Volts, 50 Hz AC, Adjustable thermal Fixed magnetic release type, connected through solid busbar of suitable size in both incoming & outgoing side - 01 No. (d) MCCB 100 Amps, 25 kA rupturing capacity, Ics=100%Icu 4 pole, 415 Volts, 50 Hz AC, Adjustable thermal Fixed magnetic release type, connected through solid busbar of suitable size in both incoming & outgoing side - 02 No.
Supply, installation, testing & commissioning in replacement of factory made CPRI approved LT feeder pillar box of suitable size, outdoor type, floor mounted, double door front and rear openable suitable for 415 volts, 3 phase, 4 wire, 50 Hz supply system all as specified and directed having busbar chamber with insulated aluminium busbar 600 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof made of 3 mm CRCA sheet duly powder coated. Panel mounted on angle iron 40x40x6 mm frame having 4 Nos legs 50 cm above ground level and 20 cm grouted in PCC below ground level including excavation, earth work in any type of soil and PCC complete with locking arrangement including internal wiring with PVC insulated multistranded copper conductor cables of suitable size, thimbling etc.with following components:- Note: The rate of earth work, PCC is deemed to be included in quoted rate by the contractor. 2 Each 64 Full Conversion INR
INCOMING:- (a) MCCB 400 Amps, 36 kA , 4 pole, 415 volts, 50 Hz, adjustable thermal and adjustable magnetic type - 01 No. (b ) Digital multifunctional meter showing V,I,Hz,Pf etc with suitable CT ratio -01 No (c) Indicating lamp (LED type) RYB - 01 Set of three OUTGOING:- (a) MCCB 125 A Amps, 16 kA rupturing capacity, 4 pole, 415 Volts lts, 50 Hz Adjustable thermal Fixed magnetic release type - 06 Nos (b) Cable connection through plug 125 Amp, 415 V, IP-67 - 06 Nos. (c) Panel mounted socket 125 Amp,415 V - 06 Nos
Taking down old unserviceable MCCBs any type an any size. 40 Each 7 Full Conversion INR
S&F in replacement of MCCB 4 Pole, 415 volts AC, 50 Hz with adjustable thermal fixed complete including thimbling carrying out modification in existing panel to fixed MCCB all as specified of following rating:-
(a) 630 Amps, 36KA 2 Each 0 Excess(+) Full Conversion INR
(b) 400 Amps, 36KA 4 Each 0 Full Conversion INR
(c) 250 Amps, 25 kA. 6 Each 4 Full Conversion INR
(d) 200 Amps, 25 kA. 4 Each 5 Full Conversion INR
(e) 160 Amps, 25 kA. 6 Each 6 Full Conversion INR
(f) 125 Amps, 25 kA. 8 Each 0 Full Conversion INR
(g) 25-100Amps, 16 kA. 10 Each 0 Full Conversion INR
M&L for disconnecting of old un-insulated cable of any size from existing panel from all the MCCB's (incoming/ outgoing) and refixing the cable after cutting the un-insulated part including thimbling of cable properly by crimpling tool and welding of old/broken LT panel door with LT panel including hinges and all other connected accessories including scrapping of old LT panel and spray painting of complete panel with standard colour (Grey) as required at site complete all specified and directed. Note: Rate of thimble is deemed to be included in quoted rate by the contractor. 10 Each 0 Full Conversion INR
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil all as specified. 10 Each 4 Full Conversion INR
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of new/serviceable cables or for fault finding in existing cable and getting out soil in soft/loose soil complete all as specified. 285 CUM 4 Full Conversion INR
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified. 250 CUM 6 Full Conversion INR
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified. 35 CUM 0 Full Conversion INR
M&L for DWC (Double Wall Corrugated) Duct Pipe as per IS code IS- 16205 (Electrical cable use) size (outer dia 77 mm and inner dia 63 mm), complete all as specified and as directed by Engineer-in-Charge. 1500 RM 4 Full Conversion INR
Material and labour for cutting of road/ hard standing up to a size not exceeding 20 cm width and not exceeding 60 cm in depth for laying of cable protection pipe including making good the disturbed road/ hard standing by providing PCC (1:2:4) type B1 to much the existing surface level, complete all as directed. 11 RM 0 Full Conversion INR
Taking out old underground serviceable/unserviceable cable of any type and size. 1782 RM 0 Full Conversion INR
Supply, Laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of following sizes:- (a) 300 Sqmm, 3.5 Core. 390 RM 0 Full Conversion INR
(b) 150 Sqmm, 3.5 Core. 260 RM 4 Full Conversion INR
(c) 95 Sqmm, 3.5 Core. 280 RM 0 Full Conversion INR
(d) 50 Sqmm, 3.5 Core. 432 RM 0 Full Conversion INR
(e) 25 Sqmm, 3.5 Core. 420 RM 0 Full Conversion INR
Supply and fix 7 mtr height hot dip galvanized octagonal poles with 130 mm bottom & 70 mm top along with base plate of size 200x200x12 (with bracket) including 4 nos of J type EN 8 grade foundation bolts with necessary foundation. complete all as specified and directed. 10 Each 0 Full Conversion INR
Supply and fixing flexible LED strip light (tricolour) with uniform distribution and longstanding adhesive, weather proof minimum length of 10 meter with driver, IP65 protection ISI marked, complete all as specified and directed by Engineer-in-Charge. 48 Each 4 Full Conversion INR
Taking down old unserviceable joint kit any type and any size. 8 Each 0 Full Conversion INR
Material and labour for end joints suitable for armoured XLPE cable 11 KV 120 Sqmm to 185 Sqmm rating heat shrinkable type complete with jointing accessories including cutting of faulty cable of any size. 4 Each 0 Full Conversion INR
Material and labour for straight through joints suitable for armoured XLPE cable 11 KV 120 Sqmm to 185 Sqmm rating heat shrinkable type complete with jointing accessories including cutting of faulty cable of any size. 4 Each 0 Full Conversion INR
Dismantling air break gang operated switch vertical/horizontal mounted including insulators and operating mechanism for replacement and removal from site all as specified and directed. 4 Each 4 Full Conversion INR
S&F air break, gang operated switches,11KV, triple pole, vertically mounted type, mechanically operated, mounted on mild steel channel with operating mechanism, worked from ground level, for current rating upto 200 Amps with drop out fuse element of required capacity, GOD/switch having 100 MVA rating at 11 KV and 12 insulators suitable for 11 KV, 50 C/s including mounting on HT poles, making necessary electric connections and testing complete all as specified and directed. 4 Each 0 Full Conversion INR
Supply & fix in replacement automatic Transfer switch 100 A, 4 Pole motorized with sheet metal enclosure 3Phase 415 V, 50 Hz supply with complete protection suitable for automatic/manual operation complete with all mounting arrangement all as specified and as directed. 2 Each 0 Full Conversion INR
M&L for lightning arresters expulsion type complete with all fittings suitable for 11000 Volt grade of discharge capacity 65 KA, connecting with HT line complete all as specified and as directed including dismantling of existing unserviceable. 6 Set of Three 0 Full Conversion INR
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20x15 cm size. 10 Each 4 Full Conversion INR
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x 20 cm size. 10 Each 6 Full Conversion INR
Note:- An amount of Rs. 37,440.00 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
Tender32.pdf
Tender Documents • 1.85 MB
BOQ_880005.xls
BOQ • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].