| 1 | L1₹32.9 LAccepted-AOC H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹37.4 L+₹4.5 L (13.5%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹40.1 L+₹7.2 L (21.7%)Rejected-AOC KILA ROAD 00 00 00 NARNAUL HARYANA 123001 | MAHENDRAGARH | HARYANA | 123001 | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹41.9 L+₹9.0 L (27.3%)Rejected-AOC 00 BALAJI ENTERPRISES NEW ROAD NEW ROAD RATLAM MADHYA PRADESH 457001 | RATLAM | MADHYA PRADESH | 457001 | L4 | Rejected-AOC Rejected being higher quoting | |
| 5 | L5₹42.4 L+₹9.5 L (28.9%)Rejected-AOC | L5 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹38.4 L
EMD Value
₹76,800
Closing Date
21 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar 125006
CA No GE(H)-59/2021-22 PROVN OF LED SECURITY LIGHTS ALONGWITH POLES AROUND PERIMETER AT HISAR MIL STN AND EBS UNDER GE HISAR
2022_MES_504829_1
CA No GE(H)-59/2021-22
Open Tender
Miscellaneous Works
Item Rate
210 days
Hisar Mil Stn
As per Tender documents
7 documents required · 7 mandatory
₹500
GE Hisar
₹76,800
Yes
9 Mar 2022
31 Jan 2022
23 Feb 2022
31 Jan 2022
21 Feb 2022
15 Feb 2022
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches not exc 1.5 metre wide and exc 1.5 metre and not exc 3.0 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick etc complete all as specified and as directed.
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed.
Material & labour cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed.
Material & labour PCC (1:3:6) type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in mass concrete including necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles complete all as specified and directed.
Supply, erecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 complete all as specified and directed. Note :- Earth work & PCC shall be measured and paid separately.
S&F micro rex analog timer T31 daily switches in accotdance with IEC 60730-1 and 60730-2-7 manual switching ON/automatic/OFF hourly/daily/weekly switching dial with capacity segments clock precision +/- 5 Minute for the daily time switch -10C to +55C operating temperature and suitable contractor, relay with complete assembly all as specified and directed. As per Cat No 412812 of Legrand or equivqlent make as approved by the GE from the makes mentioned in Appendix 'C' hereinafter.
Supply , laying , jointing, testing and commissioning of 16 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors confirming to IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply , laying , jointing, testing and commissioning of 25 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors confirming to IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
S & F MCB SPN, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S&F street light LED light fitting 60 Watt, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07, fixed on wall / pole all as specified and directed. Make : Cat Part No ENDURAPEARLNEOSL60WLED757PASYTOPC of Endura Peral Neo series of Havells or PCGLS T1 60 N (Item Code PUBO506015) of Polycab or LTESST60WLED/LS of C&S or LSTP-60-CDL of crompton or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F PVC junction box suitable for street light of size not less than 300mm x 200mm x 100mm, made out of polycarbonate having front side openable shutter duly provided with locking arrangement and provided with 02 Nos aluminium bus bar of rating 32 Amp alongwith 01 No MCB 6 Amp SP and provision of 02 Nos cable entries, fixed on street light pole with proper size MS clamp with nut & bolt and connected assessories complete all as specified and directed.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ 1.50m long, bent to shape at required angle, fixed on pole with MS clamp of size 40x5mm - 02 Nos, nuts, bolts & washers, complete all as directed. Note :- Rate quoted shall deemed to includes for MS clamp, nut, bolt & washer etc duly painted with one primer coat, one under coat and one finishing coat of aluminium paint .
Supply & fixing cable PVC insulated and PVC sheathed size 2.5 sqmm 1100 Volts grade, single core multistranded aluminium conductor from junction box to street light fittings including making electric connection both side complete all as specified and directed.
Supply & fixing rigid non metallic PVC conduit 25 mm dia including fixing on pole/wall with fittings such as tee, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hook etc complete all as specified and directed.
Supply, installation, commissioning and testing of LT Feeder pillar board, Kiosk type , 415 Volts, 50 Hz , 3-phase, 4 wire supply, CPRI approved, factory assembled ,outdoor type weather and vermin proof (Protection Class IP-65) made out of 40m x 40mm x 5mm angle iron frame, 3.15mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet duly campartmentalized for each control MCCBs, single door system lockable keys, the outer cell shall have both side hinged, front and back openable, double door system opening for external, rubber lining, locking arrangement, painted externally and internally with Nine tank pretreatment solution prior to a Powder coat of SIEMENS grey shade RAL 7032 (Berger/Nerolac) (first quality) over a coat of red oxide primer complete mounted on angle iron frame 40mmx40mmx5mm legs high above GL and 15cm embedded in ground with and including block of PCC 1:3:6 type C2 of size 30cmx30cmx30cm complete including and comprising of the following complete all as specified and directed :-
(a) Bus bar chamber comprising 4 Nos Aluminium bus bars of size not less than 1.5 times of incoming / outgoing MCCB. All spreader terminals of MCCBs should be connected to bus bars.
(c) Outgoing (i) MCCB 3 pole , LT 415 Volts, 50 Hz, AC, 63 Amps rating and 25 KA rupturing capacity, thermal & magnetic release adjustable type ( Ics =100%Icu).- 04 Nos. (ii) MCB, DP , 40 Amps - 02 Nos Note:-(i) All incoming /outgoing cables shall be connected through suitable size gland plate/glands and these will be connected with Al Lugs of suitable size also( if necessary).
M & L for earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized earth lead 25x4mm by means of GI bolts/nuts/ washers, protected by 40mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top, 20mm GI medium grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I and connected to earthing point and testing on completion. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
KUNAL ENTERPRISES
SAINI ELECTRIC STORE
Balaji Enterprises
fauji electric works
S K CONTRACTOR
HANS ENGINEERS
YASHU CONTRACTORS
M/S Sulakh Brothers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .