| 1 | L1₹93.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.1 Cr+₹12.3 L (13.2%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹1.1 Cr+₹15.4 L (16.6%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹1.1 Cr+₹17.1 L (18.3%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹1.1 Cr+₹17.9 L (19.2%)Rejected-Finance FLAT NO 201 GF KAMAL VIHAR CGHS LTD PLOT NO 5 SECTOR 7 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | Parksons Engineering Company Pvt Ltd L6 | SHRI RAMSONS PROJECTS CORPORATION L5 | HVAC Engineering Co L1 | Saini Enterprises L3 | M/S Rohit Enterprises L4 | shivrefrigeration L2 | M P TYAGI ENGINEERS AND CONTRACTORS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down / Dismantling of the existing VRV system completely comprising of all indoor cassettee units, all outdoor units, complete pipe lines including all connected items like old copper piping, cabling & drain pipe etc. removing from site and depositing in MES store yard and making good the surface all as specified and directed.
Note: There will be no seperate charges for removal of any electrical fittings and fixures during dismentling and their proper installation in working condition at the same place after completion of the work. The cost of removal/ replacement and re-installation will be included in the charges for this item. | 1 | Each Job | 60,000 ₹60,000 | 92,271.71 ₹92,271.71 | 50,000 ₹50,000 | 50,000 ₹50,000 | 3,50,000 ₹3,50,000 | 3,61,160 ₹3,61,160 | 9,999 ₹9,999 Lowest |
| 2.00Supply, installation, testing and commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled outdoor units suitable for Cooling & Heating both, having all hermetically sealed inverter type multiple scroll compressors, minimum two compressors, microprocessor based controller, top discharge type condensing units complete with indoor and outdoor units with individual wired and wireless/wired remote controller for indoor units and centralized controller,interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, vibration isolators with suitable foundation, internal control cabling and fittings complete as required and Outdoor unit connecting kit etc as per details given inspecifications and having following items. The outdoor units shall be suitable for 3 phase, 415V+10%, 50Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply. The unit shall deliver the rated capacity at AHRI Conditions and work even at 52°C ambient temperature without tripping. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. Charges for Loading, unloading & shiftting of all outdoor units to Terrace is included in this item. | ||||||||||
| 2.01Outdoor Units Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient scroll compressors (OEM manufactured) fully inverter controlled i.e. change its speed in accordance to the variation in cooling loads , special heat exchanger, low noise condenser fans with extrenal static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. For enhanced energy savings the COP of each refrigerant circuit system mentioned below shall be 7.50 minimum at 50% load, at AHRI Condition in cooling mode. The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency. (Unit shall deliver atleast 87% of mentioned nominal capacity @ 43 Deg C). The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. The units shall be suitable to operate upto 52 Deg C ambient conditions. The cost should including the first charge of refrigerant, loading, unloading, shifting of outdoor at terrace, MS stand for outdoor units of suitable size duly painted with corrosion resistant paint suitable for outdoor application.All the units shall be provided with built in microprocessor or control panel, for automatic operation and capacity control, which should be air cool. Machines shall be suitable for working with BMS system. It is mandatory that each compressor shall have inverter technology separately i.e. outdoor units shall have all inverter based compressor. Following capacities of ODUs are at standard operating condition as defined above and Vendor to indicate COP at 100% load & at part loads i.e.75% & 50% in the data sheets/ shop drawings: Note: INSIDE DESIGN CONDITION (Min temperature 18.0 Deg C and maximum temperature 22.0 Deg C, RH should be 50 % +/- 10 %. | ||||||||||
| 2.02 | 34 HP VRV Outdoor unit. Make Hitachi/Blue star/Daikin | 4 | Each | 13,00,000 ₹52,00,000 | 11,11,111.11 ₹44,44,444.44 | 10,50,000 ₹42,00,000 | 12,12,000 ₹48,48,000 | 11,00,000 ₹44,00,000 | 10,10,772 ₹40,43,088 | 8,99,999 ₹35,99,996 Lowest |
| 2.03 | DGT (Gas Tight Joint) JOINTS for outdoor units | 16 | Each | 4,500 ₹72,000 | 4,661.61 ₹74,585.76 | 2,000 ₹32,000 Lowest | 3,500 ₹56,000 | 8,500 ₹1,36,000 | 10,029 ₹1,60,464 | 9,999 ₹1,59,984 |
| 3.00Design, manufacturing, supply, installation , testing & commiissioning of following air cooling & Heating both by variable refrigerant volume modular type indoor units comprising of EEV & all accessories as per the specifications. The indoor units shall be suitable to work on cooling/heating mode having four directional air flow DX split type Indoor Air Conditioning Units of following capacity suitable for mounting inside false ceiling, each comprising of cooling coil,blower with multi speed motor, electronic expansion valve, supply & return air grilles,filter, insulated connection of refrigerant circuit, provision for fresh air intake ducting, condensate water drain pump with electronic level sensor, including wireless remote controller etc. The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork and dehumidified air quantity and the indoor units shall be of following capacities. All Indoor Units shall have inbuilt Drain Pumps. All the indoor units shall be compatible to work with VRV / VRF type condensing unit. | ||||||||||
| 3.01 | 1.55 TR FXFSQ50ARV16 4-way CASSETTE UNIT
Make Hitachi/Blue star/Daikin | 4 | Each | 67,000 ₹2,68,000 | 55,551 ₹2,22,204 | 62,000 ₹2,48,000 | 68,000 ₹2,72,000 | 60,000 ₹2,40,000 | 53,263 ₹2,13,052 Lowest | 99,999 ₹3,99,996 |
| 3.02 | 2.05 TR FXFSQ63ARV16 4-way CASSETTE UNIT
Make Hitachi/Blue star/Daikin | 10 | Each | 76,000 ₹7,60,000 | 62,621 ₹6,26,210 | 64,000 ₹6,40,000 | 68,000 ₹6,80,000 | 60,000 ₹6,00,000 | 53,916 ₹5,39,160 Lowest | 1,89,999 ₹18,99,990 |
| 3.03 | 2.55 TR FXFSQ80ARV16 4-way CASSETTE UNIT
Make Hitachi/Blue star/Daikin | 6 | Each | 85,000 ₹5,10,000 | 65,651.01 ₹3,93,906.06 | 70,000 ₹4,20,000 | 74,000 ₹4,44,000 | 65,000 ₹3,90,000 | 60,313 ₹3,61,878 Lowest | 1,99,999 ₹11,99,994 |
| 3.04 | 3.20 TR FXFSQ100ARV16 4-way CASSETTE UNIT
Make Hitachi/Blue star/Daikin | 12 | Each | 94,000 ₹11,28,000 | 72,721.11 ₹8,72,653.32 | 71,500 ₹8,58,000 | 76,000 ₹9,12,000 | 65,000 ₹7,80,000 | 61,227 ₹7,34,724 Lowest | 2,49,999 ₹29,99,988 |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
16 Jun 2025, 6:00 pmClosed
Col Laxmisha Suvarna
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
SPECIAL REPAIR / REPLACEMENT OF BER VRV AND ALLIED ITEMS AT IMAC (G) UNDER GE (AF) GURGAON
2025_MES_708976_1
CWE/GGN/GT-04/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Gurgaon
As per NIT
7 documents required · 7 mandatory
₹1,000
GE AF Gurgaon
₹2.0 L
Yes
27 Aug 2025
19 May 2025
18 Jun 2025
19 May 2025
16 Jun 2025
3 Jun 2025
19 May 2025 - 26 May 2025
Amount
Taking down / Dismantling of the existing VRV system completely comprising of all indoor cassettee units, all outdoor units, complete pipe lines including all connected items like old copper piping, cabling & drain pipe etc. removing from site and depositing in MES store yard and making good the surface all as specified and directed. Note: There will be no seperate charges for removal of any electrical fittings and fixures during dismentling and their proper installation in working condition at the same place after completion of the work. The cost of removal/ replacement and re-installation will be included in the charges for this item.
Supply, installation, testing and commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled outdoor units suitable for Cooling & Heating both, having all hermetically sealed inverter type multiple scroll compressors, minimum two compressors, microprocessor based controller, top discharge type condensing units complete with indoor and outdoor units with individual wired and wireless/wired remote controller for indoor units and centralized controller,interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, vibration isolators with suitable foundation, internal control cabling and fittings complete as required and Outdoor unit connecting kit etc as per details given inspecifications and having following items. The outdoor units shall be suitable for 3 phase, 415V+10%, 50Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply. The unit shall deliver the rated capacity at AHRI Conditions and work even at 52°C ambient temperature without tripping. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. Charges for Loading, unloading & shiftting of all outdoor units to Terrace is included in this item.
Outdoor Units Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient scroll compressors (OEM manufactured) fully inverter controlled i.e. change its speed in accordance to the variation in cooling loads , special heat exchanger, low noise condenser fans with extrenal static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. For enhanced energy savings the COP of each refrigerant circuit system mentioned below shall be 7.50 minimum at 50% load, at AHRI Condition in cooling mode. The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency. (Unit shall deliver atleast 87% of mentioned nominal capacity @ 43 Deg C). The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. The units shall be suitable to operate upto 52 Deg C ambient conditions. The cost should including the first charge of refrigerant, loading, unloading, shifting of outdoor at terrace, MS stand for outdoor units of suitable size duly painted with corrosion resistant paint suitable for outdoor application.All the units shall be provided with built in microprocessor or control panel, for automatic operation and capacity control, which should be air cool. Machines shall be suitable for working with BMS system. It is mandatory that each compressor shall have inverter technology separately i.e. outdoor units shall have all inverter based compressor. Following capacities of ODUs are at standard operating condition as defined above and Vendor to indicate COP at 100% load & at part loads i.e.75% & 50% in the data sheets/ shop drawings: Note: INSIDE DESIGN CONDITION (Min temperature 18.0 Deg C and maximum temperature 22.0 Deg C, RH should be 50 % +/- 10 %.
34 HP VRV Outdoor unit. Make Hitachi/Blue star/Daikin
DGT (Gas Tight Joint) JOINTS for outdoor units
Design, manufacturing, supply, installation , testing & commiissioning of following air cooling & Heating both by variable refrigerant volume modular type indoor units comprising of EEV & all accessories as per the specifications. The indoor units shall be suitable to work on cooling/heating mode having four directional air flow DX split type Indoor Air Conditioning Units of following capacity suitable for mounting inside false ceiling, each comprising of cooling coil,blower with multi speed motor, electronic expansion valve, supply & return air grilles,filter, insulated connection of refrigerant circuit, provision for fresh air intake ducting, condensate water drain pump with electronic level sensor, including wireless remote controller etc. The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork and dehumidified air quantity and the indoor units shall be of following capacities. All Indoor Units shall have inbuilt Drain Pumps. All the indoor units shall be compatible to work with VRV / VRF type condensing unit.
1.55 TR FXFSQ50ARV16 4-way CASSETTE UNIT Make Hitachi/Blue star/Daikin
2.05 TR FXFSQ63ARV16 4-way CASSETTE UNIT Make Hitachi/Blue star/Daikin
2.55 TR FXFSQ80ARV16 4-way CASSETTE UNIT Make Hitachi/Blue star/Daikin
3.20 TR FXFSQ100ARV16 4-way CASSETTE UNIT Make Hitachi/Blue star/Daikin
4.10 TR FXFSQ125ARV16 4-way CASSETTE UNIT Make Hitachi/Blue star/Daikin
Supply, Installation, Testing and Commissioning of Cordless handset type remote controls for the indoor units for rating of 1.55 TR, 2.05 TR, 2.55 TR, 3.20 TR and 4.10 TR all as per specified and directed by Engr-in-charge.
Supply, Installation, Testing & Commissioning of imported copper fittings to be provided in refrigerant pipe line all as per specified and directed by Engr-in-charge..
S&F refrigerant Interconnecting refrigerant pipe work with (13 mm thick) closed cell elastometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger all as specified and directed by Engr-in-charge for the following sizes:-
6.3 mm with 13 mm Insulation
9.5 mm with 13 mm Insulation
12.7 mm with 13 mm Insulation
15.8 mm with 13 mm Insulation
19.1 mm with 19 mm Insulation
22.2 mm with 19 mm Insulation
25.4 mm with 19 mm Insulation
28.6 mm with 19 mm Insulation
34.8 mm with 19mm Insulation
Supply, Installation, testing and commissioning of communication cable between indoor & outdoor units 2C x 1.5 sqmm all as specified and directed by Engr-in-charge.
S&F following heavy duty PVC pipes for condensate drain cut to required lengths and installed in position the necessary elbows, tees & reducers with 6mm nitrile rubbber insulation sleeve all as specified and directed by Engr-in-charge.
25 mm dia
32 mm dia
40 mm dia
S&F MS made outdoor frames for VRV system for protection from heavy wind and should be welded and clamped on the roof and there will be no extra cost paid to the contractor and also this item includes cement work and all necessary supporting items for the installation all as specified and directed by Engr-in-charge.
Supply, Installation, Testing and Commissioning of isolator box (IP-66) with three pole 40 amp MCB of near each ODU unit and should be sealed so as to it can sustain in the rainy season without any wear and tear all as specified and directed by Engr-in-charge.
S&F XLPE insulated Copper conductor, 1.1 KV grade cable of following size complete all as specified and directed by Engr-in-charge.
4C x 10 Sq mm, Copper Armoured power cable for outdoor units
3C x 2.5sqmm, Copper Flexible power cable for indoor units
4C x 150 sqmm Aluminium armoured cable from LT/Building panel to Main HVAC electrical panel
S&F end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade all as specified and directed by Engr-in-charge for the following sizes:
4 X 10 sq. mm (25mm)
4 X 150 sq. mm (57mm)
S&F 6 SWG dia G.I. wire on surface or in recess for loop earthing all as specified and directed by Engr-in-charge.
S&F GI perforated cable tray for outside copper piping & electrical power cables all as specified and directed by Engr-in-charge for the following sizes:-
450mm x 75mm x 1.6mm thick
300mm x 75mm x 1.6mm thick
200mm x 75mm x 1.6mm thick
M&L for cutting, dismentling & repairing of false ceiling wherever required to install the complete system like all cassette indoors, all outdoor units, all copper piping, cabling & drain pipe etc. all as specified and directed by Engr-in-charge. Note- (i) This item includes all materials required to make the good as the original one and also all the material required. (ii) This item also include all the new items required to replace the broken one and this should be done as per direction of Engr-in-charge and also upto satisfaction level of Engr-in-charge.
M&L for civil works opening or finishing of walls with paint, plaster & putty etc for crossing the copper & drain pipe complete all as specified and directed by Engr-in-charge. Note- (i) This item includes all the materials like paint, putty and all other items. (ii) This item also include all the new items required to replace the broken one and this should be done as per direction of Engr-in-charge and also upto satisfaction level of Engr-in-charge.
shivrefrigeration (BID ID -3324946)
Saini Enterprises (BID ID -3324466)
M/S Rohit Enterprises (BID ID -3324889)
SHRI RAMSONS PROJECTS CORPORATION (BID ID -3317474)
Parksons Engineering Company Pvt Ltd (BID ID -3316108)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3322741)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .