computer servers Average Turn Over of Last 3 Years 300 Lakh (s) Experience with Gov. Required 5 Year (s) Computer Servers ( 12 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values Specification Form Factor Tower Rack
Tower Size (RU) 4 * Processor Make Intel Intel
AMD
SPARC Max. Number of sockets available on chipset 1 1-16 Max. Number of sockets populated with processor 1 1-16 Number of core per Processor 4 * Processor Configuration E3-1585 v5
4 Core
3.5 GHz
8 MB L3 cache memory
65 watt * Chipset compatible with CPU Intel c236 * Availability of Co- No * 1/4 Processor If Yes Co-Processor Configuration NA * PCI Slots (Express Gen 3.0) 4 * Type of RAM DDR4 * RAM Size (GB) 16 16-16000 RAM upgradable upto (GB) 59 32-24000 DIMM Slots (No.) 4 * Type of Hard Disk Drive SATA SAS
NL SAS
SSD
SATA Hard disk drive Capacity (GB) 2000 300-12000 Hard disk drive Speed (RPM) 7200 * RAID Controller Cache (MB) 512 * RAID Type 1 * RAID Controller Ports @12 Gbps 2 * Video Controller (support VGA or above resolution) Yes * Keyboard Yes * Mouse Yes * Bays (min. 2 internal or more hot plug) 2 * USB Ports (version 2.0/3.0) 4 * Certifications Compliance support by Windows
Red Hat or Novell or Oracle Cluster S/W Yes * DVD ROM (or better) 8x or better * Network Card Supported 1G * FC HBA Dual port card NA * FC HBA Dual port card Speed NA * Power Management - * Redundant Power Supply No * 2/4 Redundant Fan Yes * Total No of Ports 1 * Declare SPEC int_rate_base 2006 ; specfp_rate_2006 for 1
2
4
8 prcessor as applicable 2 * Server scalability to be achieved within the box without adding nodes NA * RoHS Compliance Yes * BIS Registration number & its Validity - * Max. power consumption of the system (Watt) 250 * Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
the server shall be functional Yes * Name address of Lab - * Test Report No. date - * Power Supply 230 V +/-10%
50 Hz * 3/4 On Site OEM Warranty (years) 5 1
3
5 (or higher) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Yogesh Bodade 444001
Assistant Commissioner Social Welfare Collector Office Premises 2nd Floor Administrative Building 12 15