| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.4 L+₹2.5 L (6.36%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹42.8 L+₹2.9 L (7.34%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹42.9 L+₹2.9 L (7.38%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | Rejected-Technical QURESHI BUILDING BUDSHAH CHOWK SRINAGAR 190001 KASHMIR J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | - | Rejected-Technical Due to not appropriate category, firm is Not Admitted |
Tender Value
Refer Docs
EMD Value
₹79,040
Closing Date
11 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS PIN-914133 C/O 56 APO
PROVN OF 250 KVA TRANSFORMER AND VOLTAGE STABILIZER OF VARIOUS CAPACITY WITH ALLIED INFRA FOR CHOWKIBAL AND INF BN, PANZAGAM UNDER GE 874 EWS
2022_MES_513434_2
CWEK-78/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 874 EWS
Class D Category a i and b ii
7 documents required · 7 mandatory
₹500
GE 874 EWS
₹79,040
Yes
HQ 133 WORKS ENGRS
5 Aug 2022
19 Apr 2022
19 May 2022
19 Apr 2022
11 May 2022
27 Apr 2022
19 Apr 2022 - 23 Apr 2022
21 Apr 2022
60 days
Amount
Surface excavation in hard/dense soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified
Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 m in depth for foundation of poles, stay assembly and laying of LT/HT cable as in hard/dense soil and getting out, complete all as specified and directed.
All as per Srl item No 02 here-in-before above but depth exceeding 1.5 m in depth and not exceeding 3 m, complete all as specified and directed.
Excavating in post holes (or similar holes) each not exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface, work in hard/dense soil, complete all as specified
Returning filling, including spreading, leveling , watering and well ramming in layers not exceeding 25 cm in hard/dense soil, complete all as specified and directed.
Removal of excavated material i.e soil to a distance not exc. 50m and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
M & L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces and surfaces even and fair complete all as specified and as directed.
Spreading and levelling in layers n exc. 25 cm thick,including well ramming and watering under floor complete all as specified
M & L for hardcore of broken stone or boulders exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled/rammed to a true surface, complete all as specified
M & L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15cm thick, spread, levelled and rammed including watering, complete all as specified
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I. Note :- 1. Dry fine sand of best available quality shall be used. 2. Punned thickness shall be measured and paid.
M & L Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
M & L for cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, , complete all as specified and as directed by the Engineer-in-Charge
M & L for forming Construction joint 30mm deep x 10mm wide filled with sealing compound, Grade `A`,( thickness of concrete slab 150 mm) complete all as specified and as directed by the Engineer-in-Charge
M & L for 100 mm thick PCC 1:4:8 Type D-2 (using 40mm graded aggregate) as in sub base over rammed earth complete all as specified and as directed.
M & L for 75 mm thick PCC 1:3:6 Type D-2 (using 40mm graded aggregate) as in sub base of floor complete all as specified and as directed.
M & L for 50 mm thick PCC 1:3:6 Type C-1 (using 20mm graded aggregate) as in plinth protection including finishing even and fair complete all as specified and as directed.
M & L for PCC 1:4:8 Type D-2 (using 40mm graded aggregate) as in foundation of poles streets and stay complete all as specified and as directed by the Engineer-in-Charge.
M & L for PCC 1:3:6 Type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L for Plain cement concrete 1:2:4, type C-2, (using 40 mm graded crushed stone aggregates) as in copings and the like including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-2, (using 40 mm graded crushed stone aggregates) as in post hole filling and mass concrete complete all as specified and directed.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., quality confirming to Fe 410-W (GDE-E-250) quality A- complete all as specified and as directed by the Engineer-in-Charge
S & F for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
S & F for Pre-painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
M & L for preparation of new or previously untreated steel or iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a priming coat with red oxide complete all as specified and as directed.
M& L for preparation of newly plastered/unplastered surfaces and applying two coats of white wash complete all as specified and as directed.
S & F for 80mm bore `Light grade` GI tubing ISI marked with cutting as required and bend to shape for fixing with electric poles as cable protection fixed on pole or laid in trenches under floor,duct etc with fixing clamps,nuts bolts etc complete all as specified and as directed.
Supply , installation, testing and commissioning outdoor type Step down transformer, 11 KV/433 Volts, (at Full load) AC 3 Phase 50 HZ , 250 KVA Capacity core type , double copper wound, oil immersed , naturally cooled, oil natural Air Natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connnected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having taping at ±2.5% & ± 5% on HV side to be charged by means of hands operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measurement by resistence method after continuous full load run on an ambient temp of 40 degree celsius. The transformer shall be BEE star rated as per confirmed IS -1180 and be provided with suitable overhead Galvalum sheeted roof for rain protection complete all as specified and as directed by Engineer in charge.
Supply and installation of voltage stabilizer for auto matic opereation, three phase naturally Oil cooled indoor type and designed input variation between 340 Volts to 460 volts with out put voltage stabilized at 415 Volts with accuraccy + 2.5 % and speed of correction 8 Volts per Second and of capacity 100 KVA, construction of suitable PCC foundation including making of connections and testing complete all as specified and as directed by Engineer in charge.
Supply and installation of voltage stabilizer for auto matic opereation, three phase naturally Oil cooled indoor type and designed input variation between 300 Volts to 480 volts with out put voltage stabilized at 415 Volts with accuraccy + 2.5 % and speed of correction 8 Volts per Second and of capacity 250 KVA, complete all as specified and as directed by Engineer in charge.
Supply, fixing, commissioning and testing Switch Air break gang operated outdoor type HT 11 KV, triple pole, 200 Amps, air break fitting type with fixed contacts of phospherous bronze and moving contact of copper with mechanically operated rod from ground level, vertical / horizontal mounted complete with HT insulator on and including steel frame ,operating rod made out of 25mm dia GI pipe medium grade with 12 insulators and making all incoming /outdoor connections including two coats of aluminium paint over a coat of red oxide primer on steel surfaces, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of steel tubular swaged poles erected truly vertical or planted as strut complete with 300x300x6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap,bolts,nuts & screws,poles made out of ERW MS tubing conforming to IS-2713 Part-11 type 410 SP-55 (11.0 metres long) including drilling of holes of reqd size foe fixing of cross arm, painting the exposed surfaces of pole with two coats of aluminium paint over one coat of red oxide zinc chrome primer and with black & bitumenous paint externally for portition embedded in concrete, making five black & red bands at lower portition of pole each 300 mm wide alternately,and making pole NO.with black paint at suitable height complete all specified and directed.
Supply,installation,testing and commissioning ,factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50Hz AC supply, having bus bar chamber with insulated copper bus bar of 160 Amps rating installed on porcelain insulator.The Panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry,with double door shutter and locking arrangment (including provn of 65 mm Godrej (Freedom) lock with 2 key, internal wiring 2.5 Sqmm with PVC insulated, soild copper conductor ,FRLS cables, IS-694 marked of adequate size including the provision of space to accommodation the under mentioned items. The scope of work includes the followings:-
Supply,installation,testing and commissioning ,factory made and tested (prototype having been CPRI type test certified), LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50Hz AC supply, having bus bar chamber with insulated copper bus bar of 500 Amps rating installed on porcelain insulator.The Panel shall be dust and vermin proof, IP 65 class protection and made of 2 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry,with double door shutter and locking arrangment (including provn of 65 mm Godrej (Freedom) lock with 2 key, internal wiring 2.5 Sqmm with PVC insulated,soild copper conductor ,FRLS cables, IS-694 marked of adequate size including the provision of space to accommodation the under mentioned items. The scope of work includes the followings:-
Supply and fixing of Aluminium Conductor Steel Reinforced, of any size (as required ), including stretching, fixing and binding to insulator on OH/HT line service feeders with aluminium binding wire or aluminium tapes which shall not be included in weight of conductor, complete all as specified and directed.
M & L for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11 KV Voltage grade, complete all as specified and as directed by the Engineer-in-Charge
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coat of aluminium paint over one coat of red oxide primer, complete all as specified and directed.
M & L for Loop type insulator,vitreous porcelain,white, brown or green, large size, with overall dimensions 90 x 140mm clearance of hole 25.5 mm, complete all as specified and as directed.
M & L of shackle type, porcelain (or polymer insulator if required , vitreous,white brown or green insulators for working pressure in 11000 volts , Height in 150 mm and Max 150 mm dia, Galvanised steel fittings Section of straps in 38 x 5 mm and 20 mm dia of bolts, complete all as specified and directed.
M & L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade 150mm height 150mm dia for 11000 volts grade, complete all as specified and directed.
M & L for stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately), Diameter of stay rod in 20 mm, complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 25x4 mm and protection pipe of 40 mm bore medium graded ,GI light graded 20mm bore watering pipe
M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 25x4 mm and protection pipe of 40 mm bore medium graded ,GI light graded 20mm bore watering pipe
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3 Core 120 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 95 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 70 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 35 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Core 25 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Core 16 Sqmm, ISI marked complete, all as specified and as directed.
M & L for Cable Jointing Kit for 11 KV (Earthed) Grade cable for Outdoor termination, Heat shrink type, joint complete with jointing material and accessories suitable for 3 Core XLPE Armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
Material and laying in replacement of aluminium bus bars of capacity of 300 Amps rating,insulated with colour coded heat shrink insulation of 1100V grade, with polymer insulators complete all as specified and directed.
Material and Labour for painting of LT panel inside and outside complete with two coats (each coat to be of 0.25mm thick) of water proof electrically insulating enamel paint complete all as specified and directed by Engineer-in-Charge.
Material and Labour for repair of existing LT Panel by cutting corroded locations of the panel and replacement with new powder coated 3.15 mm thick MS sheet (to be measured in sqm based on the the new sheet used) complete all as specified and directed.
Supply and fixing of RCBO, four pole three phase and neutral 415 Volts, 50H 63 Amps, 30 m A complete all as specified and directed.
Supply & fixing for Sheet Metal enclosure factory made for DBs Triple pole and neutral Single door 415 volts 4 way with 200 Amps rated bus bar fixed to waal,including dressing and connecting both incoming and outgoing cable termination with proper taping,lagging testing and commissioning and making good of wall,surface all as specified and directed.
Supply & fixing for Sheet Metal enclosure factory made for DBs Single pole and neutral Double door 240 volts 12 way with 200 Amps rated bus bar fixed to waal,including dressing and connecting both incoming and outgoing cable termination with proper taping,lagging testing and commissioning and making good of wall,surface all as specified and directed.
Supply and fixing of 415 V 10 KA 'C' curve miniature circuit breaker (MCB) of TPN 40 to 100 Amps and current carring capacity in the DB complete with connection testing and commissioning all as specified and directed.
Supply and fixing of 240 V 10 KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 Amps and current carring capacity in the DB complete with connection testing and commissioning all as specified and directed.
Supply and fixing of 240 V 10 KA 'C' curve miniature circuit breaker (MCB) of SP 06 to 32 Amps and current carring capacity in the DB complete with connection testing and commissioning all as specified and directed.
Supply and fixing of three phase Voltage and current protection relay of protection from over current as well as over voltage and auto adjustable complete with connecting testing and commissioning all as specified and directed by Enginne-in-Charge.
Supply and fixing, Single phase Voltage protection relay of trip setting 85 to 500 V AC complete with connecting testing and commissioning all as specified and directed by Engineer-in-Charge.
M&L for Construction of shed for suitable for 250 KVA Transformer including steps,plinth protection,cable duct complete all as specified and directed as shown on drawing NO CESZ/TD-1110/2011 sheet 1/2 and 2/2 Dated 01/12/2011 Note : Drawings are available with office & GE office.Please visit this office/GE office during working hours before submission of tender.
Rajindera Enterprises
M/S NORTHERN ELECTRICAL WORKS
M/s Pall Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .