Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
15 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE(AF) Bamrauli
HQ CWE(AF) Bamrauli prayagraj 211012
PROVN OF STANDBY POWER SUPPLY TO OPS ROOM AT NORTH CAMP AT AF STN BAMRAULI
2024_MES_653410_3
87313/C/E8
Open Tender
Civil Works
Item Rate
182 days
GE(AF) Bamrauli
MES Enlisted Contractor of Class D category b i
8 documents required · 8 mandatory
₹500
GE(AF) Bamrauli
₹84,000
Yes
24 Oct 2024
13 Sept 2024
19 Oct 2024
13 Sept 2024
15 Oct 2024
26 Sept 2024
13 Sept 2024 - 20 Sept 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for natural river sand as cushioning of cables including spreading and punning down complete all as specified and as directed. Note : Punned thickness shall be measured for payment purpose
Supply and Laying old size bricks , sub class 'B' of size 230mm x 115 mm x 75 mm for cable protection complete all as specified and as directed.
M&L for 100mm dia bore galvanised iron light grade for cable protection and sealing both ends complete all as specified and as directed. Make:- Tata/ Jindal/ Prakash Surya.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 240 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. Make:- Finolex/ Gloster/ Polycab
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6 mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.3 of SSR part I-2009 and earth wire protected by galvanized pipe light grade 40mm bore and through test point, filling of adequate quantity of charcol and common salt including necessary earth work and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in chamber with cast iron earthing pit cover having size 250 mmx250 mm, weight not less than 7.5 Kg conforming to relevant IS with frame complete all as specified and directed and testing on completion.
Earthing complete with Copper plate earth plate electrode 60 cm x 60cmx 3.15mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized Copper strip 25mm x 3 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.3 of SSR part I-2009 and earth wire protected by galvanized pipe light grade 40mm bore through test point, filling of adequate quantity of charcol and common salt including necessary earth work and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in chamber with cast iron earthing pit cover having size 250mmx250mm, weight not less than 7.5 Kg conforming to relevant IS with frame complete all as specified and directed and testing on completion.
Supply, installation, testing and commissioning outdoor type PLC based cubical feeder pillar box having outer and inner shells suitable for 3 Phase , 4 wire 415 Volt, 50 hz ,CPRI approved factory fabricated with CRCA sheet not less than 3.15 mm thick having modern fabrication process powder coated with pure polyster siemens grey structural RAL 7032 shade. The dimensions of the outer shell should be adequate to accommodate inner shell described below giving 50 mm space all around and shall be fabricated in such a way that the whole inner shell alongwith its control gears and accessories could be taken outside without disturbing outer shell. Gasket shall be used to make the outer shell completely make it dust and vermin proof and general constructions conforming to IS 8623/93. The LT panel shall be front and back openable, double door system lockable/openable by key from both side having flush pattern fancy locks and the inner shell duly compartmentalized for each control gear, front openable single door system. The panel should have suitable size of aluminium Bus bar TPN three phase 4 wire system and extension links rating current carrying capacity not less than 1.5 times the rated capacity of the incomer MCCB, The panel should have the following incoming and outgoing controls duly supply and fixed with the panel by means of suitable link plates complete as given below:- (a) MCCB 4 ploe 630 Amps rupturing capacity 50 KA with microprocessor release type -03 No (Incoming - 02 Nos & Outgoing -01No) (b) MCCB 4 pole 160 Amps rupturing capacity 36 KA with microprocessor release type-02 Nos (c) ON load change over switch 630 Amps -02 Nos (d) Digital multifunctional meter VAFPF (voltage, current,frequency, power factor)-01 No (e) Phase Indicator lamps R,Y & B (LED type) - 01 set (set of three) (f) Complete internal wiring as required Note:-Name of manufacturer alongwith drawing of panel shall be got approved by GE before placing order for procurement.
Supply, installation, testing and comissioning silent static Disel Engine driven Generating set of capacity 400 KVA (out put capacity), water cooled, 415 volts , 4 wire, 50 Hz as per IS:10001 and Alternator as per IS-13364, complete with relay panel, continues rating, power factor 0.8 (lagging) and connections as per IE rule, DG set mounted on a common MS fabricated base frame with anti vibration pad mounting including foundation as recommended by manufacturers. The engine generally confirm to BS-5514, IS : 10002 : 1981 and including RECD device as per CPCB norms for noise and emission limits and necessary certificate from NAL to the effect shall be submitted and complete of 400 KVA capacity with 5 module microprocessor based control system including microprocessor based engine safety unit with following accessories as specified hereinafter:- Make - Ashok Leyland / Kirloskar / Cummins
(A) DIESEL ENGINE:- Diesel engine 1500RPM, direct injection, multi cylinders, four stroke, conforming to conforming to IS:10001/ISO 3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 400 KVA at outdoor atmospheric conditions at Bamrauli ( Taking all derating factor into consideration) fitting with the following accessories subject to the design of manufacturer:- (i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A, Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level including RECD device as per CPCB directions (v) Radiator cooling (vi) Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter and fuel houses (ix) Fuel injection pump (FIP) (x) Fan and water pump assesembly
(xi) Lub oil filter and pump (xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid bty as per manufacturer recommendation including inter connecting cables/leads with terminals complete with starting/stopping switch voltmeter, etc 01 set (xiii) Engine safety shut down system against low oil pressure and high water pressure (xiv) Exhaust gas driven turbo charge (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine main manual with spare part list (xviii) Suitable designed acoustic enclosure as per CPCB regulations (xix) Any other item not included / specified but is a standard design of the manufacturer.
(B) ENGINE INSTRUMENT PANEL :- Engine instrument panel shall comprising of the following:- (i) Starting on /off switch. (ii) water temp gauge. (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure. (viii) Any other item not included/specified but is a standard design of the manufacturer.
(C) ALTERNATOR :- The alternator shall be self excited, self regulated, brush less for 400 KVA confirming to IS-13364 suitable for operation at 1500 RPM, 415 volt, 0.8 power factor (lag) suitable for 50 Hz, AC.3 phase, 4 wire system confirming to BS 5000/ IS 4722. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR confirming to IS/IEC 60034. The alternator with the following features :- (i) +1% voltage regulation (max) in static conditions (ii) IP-23 protection with insulation class H (iii) Permissible over load of 10% for one hour in 12 hours of operation with standard design with IP23. Note:- Alternator should be able to deliver output rating at actual site condition.
(D) Mounting Arrangement :- Engine and Alternator are mounted on a common fabricated base frame made from structural channel, jerk proof, PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in foundation including adequate number of suitable anti-vibration pads all as per manufacture recommendations. Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continuous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per standard engineering practice complete Bypass arrangement by providing separate panel made out of 3mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 630 Amp is to be installed near AMF panel (i) Hour run meter. (ii) Any other item not included/ specified but is a standard design to the manufacturer.
(E) AMF CONTROL PANEL:- Supply, fabricating and testing of factory mounted cubical automatic main failure panel with degree of protection IP-42 conforming to IS-2147, suitable for 400 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories:- (i) Master switch for auto/manual/reset/off- 01 No (ii) Ammeter digital type, 96mmX96 mm with CT's-03 Nos Aux supply 230 Volts AC, acuracy class 1. (iii)Voltmeter digital type 96mmx96 mm to read 0-500 volts supply 230 volts, accuracy class 1.0 (iv) Digital frequency meter-01 No Aux supply 230 volts, AC (v) Push button start, stop, reset-01 No. (vi) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure.
(vii) Transformer of adequate rating. (viii) Ractifiers (ix) DC Ampere meter and Voltmeter. (x) Fault accept / reset push button. (xi) Set of relays and contactor suitable for 400 KVA DG Set for automatic start and automatically shut down of suitable rating and capacity adjustable to 70 to 100% and 2 Nos MCCB 4 pole, 630 Amp, 50 KA fixed on main supply and DG set supply. (xii) Make of AMF control panel shall be as per OEM recommendations. (F) Notes : (i) PCC foundation for DG Set and panel boards shall deemed to be included in unit rate quoted. PCC foundation of adequate/required size extending to 1.0 Mtr all round more than the size of DG set, as per manufacturer design.
(G) Testing of DG Set (i) The DG set will be tested at manufacturer premises/factory in presence of authorized Rep of Accepting officer. (ii) The DG set will be tested on load of unity power factor (PF=1) for the rated KW rating of the DG set. During testing the DG set will be run for a period of 12 hrs non-stop at full rated capacity on full load and one hr on 10% extra load above the rated capacity after 12 hrs of continuous run. (iii) The contractor has to arrange external load for the testing of DG sets at his own cost. The cost deemed to be included in the quoted amount. (iv) The contractor has to arrange POL/Diesel/Staff/Technician at his own cost for the testing. The cost deemed to be included in the quoted amount.
PRASHANT ENTERPRISES (BID ID -3126673)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .