Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-Finance | L1 | Accepted-Finance 1st.LOWEST BIDDER | |
| 2 | L2₹1.4 L+₹3,845 (2.90%)Rejected-Finance | L2 | Rejected-Finance 2nd.LOWEST BIDDER | |
| 3 | L3₹1.4 L+₹4,521 (3.41%)Rejected-Finance | L3 | Rejected-Finance 3rd.LOWEST BIDDER | |
| 4 | L4₹1.4 L+₹5,795 (4.37%)Rejected-Finance | L4 | Rejected-Finance 4th.LOWEST BIDDER |
| Sl No | Description | Qty | Unit | MODI POWER CONSTRUCTION L2 | Harshit Enterprises L4 | Sampada Trading Company L1 | M/s Radha Enterprises L3 |
|---|---|---|---|---|---|---|---|
| 1.00Following works to be done for replacement of 03 No. 33 KV Triple Feeder Control & Relay Panel at 220 KV S/S BARAHUWA, GKP Detail of feecder is given below | |||||||
| 1.01 | Dismantaling of old and used 33 KV Triple Feeder Control & Relay Panel at 220 KV S/S BARAHUWA, GKP by opening of side nut, bolts, earthing,grouting nuts and bolts and shifting from Ist 1.01 floor control room to ground floor 1 and shift the control panel from ground floor to JE store with the help of hydra/cane (distance approx 300 mtr.)and placing in place of old Panel. (01 Job for each Panel) | 3 | Job | 7,500 ₹22,500 Lowest | 8,000 ₹24,000 | 7,500 ₹22,500 Lowest | 8,100 ₹24,300 |
| 1.02 | Safe shifting of new 33 KV Triple Feeder Control & Relay Panel at 220 KV S/S BARAHUWA, GKP from Je store to ground floor of 1.02 control room and shifting panel from ground floor to Ist floor of control room with the help of hydra/crane and Erection of Panel including cutting of floor/chequrred plates of panel. | 3 | Job | 8,500 ₹25,500 | 6,000 ₹18,000 | 5,800 ₹17,400 Lowest | 5,950 ₹17,850 |
| 2.00Laying of following size PVC unarmoured copper between 220 KV CT, CB, DCDB, ACDB, and associated Marshalling Boxes to control/relay panels and also from equipment control cubicles to their JBs as per direction of supervising engineer after opening of cable trenches and placing trench cover originally after shifting cable drum from store& reuring balance cable back to store | |||||||
| 2.01 | 2.01 2C X2.5 sq. mm | 2,000 | RMT | 4 ₹8,000 Lowest | 5 ₹10,000 | 4.5 ₹9,000 | 4.8 ₹9,600 |
| 2.02 | 2.02 4C X2.5 sq. mm | 4,000 | RMT | 4 ₹16,000 Lowest | 6.5 ₹26,000 | 6.25 ₹25,000 | 6.4 ₹25,600 |
| 2.03 | 2.03 6C X 2.5 sq.mm | 3,000 | RMT | 5 ₹15,000 Lowest | 8.5 ₹25,500 | 8.25 ₹24,750 | 8.4 ₹25,200 |
| 2.04 | 2.04 10C X 2.5 sq. mm | 1,500 | RMT | 5 ₹7,500 Lowest | 9.5 ₹14,250 | 9.15 ₹13,725 | 9.4 ₹14,100 |
| 3.00 | Termination of following size of cables as laid per cable schedule including making necessary holes in gland plate, fixing of cable gland, wire ferrule and copper lugs of proper size then termination as per cable schedule with all cost of men and T&P for completion of job(01 Job for each feeder) | 3 | Job | 12,500 ₹37,500 | 6,000 ₹18,000 | 5,900 ₹17,700 Lowest | 5,950 ₹17,850 |
| 4.00 | Iarthing of control panel with existing earth strip as required with the help of welding machine(MS FLAT 25X06 mm or 50x 06 mm will be provided by department | 3 | Job | 1,450 ₹4,350 | 850 ₹2,550 | 810 ₹2,430 Lowest | 842 ₹2,526 |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
25 Sept 2025, 4:00 pmClosed
EXECUTIVE ENGINEER ETD-II
EXECUTIVE ENGINEER ELECTCITY TRANSMISSION DIVISION II UPPTCL GORAKHPUR
DISMANTLE AND ERECTION OF 03 NOS. 33KV TRIPLE CONTROL AND RELAY PANEL AT 220KV S S BARAHUWA GORAKHPUR UNDER ETD-II GORAKHPUR
2025_UPTCL_1073610_1
18-ETD-II(G)/2025-26
Open Tender
Electrical Works
Item Rate
60 days
220KV SUB-STATION BARAHUWA GORAKHPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EXECUTIVE ENGINEER ELECTRICITY TRANSMISSION DIVISI
₹2,000
27 Sept 2025
12 Sept 2025
26 Sept 2025
13 Sept 2025
25 Sept 2025
13 Sept 2025
Amount
Following works to be done for replacement of 03 No. 33 KV Triple Feeder Control & Relay Panel at 220 KV S/S BARAHUWA, GKP Detail of feecder is given below
Dismantaling of old and used 33 KV Triple Feeder Control & Relay Panel at 220 KV S/S BARAHUWA, GKP by opening of side nut, bolts, earthing,grouting nuts and bolts and shifting from Ist 1.01 floor control room to ground floor 1 and shift the control panel from ground floor to JE store with the help of hydra/cane (distance approx 300 mtr.)and placing in place of old Panel. (01 Job for each Panel)
Safe shifting of new 33 KV Triple Feeder Control & Relay Panel at 220 KV S/S BARAHUWA, GKP from Je store to ground floor of 1.02 control room and shifting panel from ground floor to Ist floor of control room with the help of hydra/crane and Erection of Panel including cutting of floor/chequrred plates of panel.
Laying of following size PVC unarmoured copper between 220 KV CT, CB, DCDB, ACDB, and associated Marshalling Boxes to control/relay panels and also from equipment control cubicles to their JBs as per direction of supervising engineer after opening of cable trenches and placing trench cover originally after shifting cable drum from store& reuring balance cable back to store
2.01 2C X2.5 sq. mm
2.02 4C X2.5 sq. mm
2.03 6C X 2.5 sq.mm
2.04 10C X 2.5 sq. mm
Termination of following size of cables as laid per cable schedule including making necessary holes in gland plate, fixing of cable gland, wire ferrule and copper lugs of proper size then termination as per cable schedule with all cost of men and T&P for completion of job(01 Job for each feeder)
Iarthing of control panel with existing earth strip as required with the help of welding machine(MS FLAT 25X06 mm or 50x 06 mm will be provided by department
MODI POWER CONSTRUCTION (BID ID -5535989)
M/s Radha Enterprises (BID ID -5560443)
Harshit Enterprises (BID ID -5560427)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .