Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC 64 CALLIN STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.0 L+₹19,221 (0.41%)Rejected-AOC 30 DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-AOC 2nd Lowest Bidder | |
| 3 | L3₹48.9 L+₹2.1 L (4.41%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | L4₹50.2 L+₹3.4 L (7.27%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L4 | Rejected-Finance 4th Lowest Bidder | |
| 5 | L5₹57.4 L+₹10.6 L (22.6%)Rejected-Finance 14 SURI LANE KOLKATA 14 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L5 | Rejected-Finance 5th Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹94,500
Closing Date
9 Sept 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE-I, WKED, PWD
New Sectt. Building, 1, K.S. Roy Road, C-Block, 4th floor, Kolkata- 700 001
Arrangement of cable tray for dressing of the existing cable, wires from wall to tray and some ancillary work at Main, Annex and Centenary Bldg of HC, Calcutta.
2021_WBPWD_341010_1
WBPWD/EE-WKED/NIQ-07/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
High Court
Please refer Tender documents.
3 documents required · 3 mandatory
₹94,500
8 Oct 2021
19 Aug 2021
13 Sept 2021
19 Aug 2021
9 Sept 2021
20 Aug 2021
90 days
Amount
Supply & Fixing of following sizes boxing GI cable tray having two parts i) perforated bottom, perforation not more than 17.5% with following depth ii) perforated top overlapping cover with following depth and fixing with bottom tray by required sizes steel screwing arrangement, rest on S & F of G.I Angle iron(40mm x 40mm x 6mm angle length mentioed with the following tray) ladder type structure 2 nos. 40 mm x 5 mm GI flat strip welded as step of ladder per mrt length fixed on wall either grouting of by three nos. 3 inches/required sizes steel fastener etc. as required and mending good damages to original finish, Incl. weather cote painting (wall matching colour) of entire boxing & angle support or as per direction of EIC.(note:- in design wall or Pillar the tray will be designed accordingly or it may be as per direction of EIC.)
i) 300x(50/25)x1.25mm [(50mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray rest on "L" shaped angle structure(2nos. per meter) length 400mm (each)
ii) 200x(50/25)x1.25mm [(50mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray rest on "L" shaped angle structure(2nos. per meter) length 300mm (each)
iii) 300x(75/25)x1.25mm [(75mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray rest on "L" shaped angle structure (2nos. per meter) length 400mm(each)
iv) 200x(75/25)x1.25mm [(75mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray rest on "L" shaped angle structure (2nos. per meter) length 300mm (each)
Supply & Fixing of following sizes boxing GI cable tray bend having two parts i) perforated bottom, perforation not more than 17.5% with following depth ii) perforated top overlapping cover with following depth and fixing with bottom tray by required sizes steel screwing arrangement, rest on S & F of G.I Angle iron(40mm x 40mm x 6mm angle length mentioed with the following tray) ladder type structure 2 nos. 40 mm x 5 mm GI flat strip welded as step of ladder per mrt length fixed on wall either grouting of by required nos. 3 inches/required sizes steel fastener etc. as required and mending good damages to original finish, Incl. weather cote painting (wall matching colour) of entire boxing & angle support or as per direction of EIC
i) 300x(50/25)x1.25mm [(50mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
ii) 200x(50/25)x1.25mm [(50mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
iii) 300x(75/25)x1.25mm [(75mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
iv) 200x(75/25)x1.25mm [(75mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
Supply & Fixing of following sizes boxing GI cable tray reducer having two parts i) perforated bottom, perforation not more than 17.5% with following depth ii) perforated top overlapping cover with following depth and fixing with bottom tray by required sizes steel screwing arrangement, rest on S & F of G.I Angle iron(40mm x 40mm x 6mm angle length mentioed with the following tray) ladder type structure 2 nos. 40 mm x 5 mm GI flat strip welded as step of ladder per mrt length fixed on wall either grouting of by required nos. 3 inches/required sizes steel fastener etc. as required and mending good damages to original finish, Incl. weather cote painting (wall matching colour) of entire boxing & angle support or as per direction of EIC
i) 300x200(50/25)x1.25mm [(50mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
ii) 300x200(75/25)x1.25mm [(75mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
Supply & Fixing of following sizes boxing GI cable tray tee having two parts i) perforated bottom, perforation not more than 17.5% with following depth ii) perforated top overlapping cover with following depth and fixing with bottom tray by required sizes steel screwing arrangement, rest on S & F of G.I Angle iron(40mm x 40mm x 6mm angle length mentioed with the following tray) ladder type structure 2 nos. 40 mm x 5 mm GI flat strip welded as step of ladder per mrt length fixed on wall either grouting of by required nos. 3 inches/required sizes steel fastener etc. as required and mending good damages to original finish, Incl. weather cote painting (wall matching colour) of entire boxing & angle support or as per direction of EIC
i) 300x(50/25)x1.25mm [(50mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
ii) 200x(50/25)x1.25mm [(50mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
iii) 300x(75/25)x1.25mm [(75mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
iv) 200x(75/25)x1.25mm [(75mm edge height) for bottom and (25mm edge height) for top] along with Ladder type angle structure width same as tray.
Supply and Laying of PVC/XLPE insulate Armoured Alluminium Cable in Existing Tray.
a) 4 core 70 sq mm
b) 4 core 50 sq mm
d)4 core 25 sq mm
Supply and Laying of PVC/XLPE insulate Armoured Alluminium Cable through Wall on surface by clamping arrangement as to GS
a) 4 core 70 sq mm
b) 4 core 50 sq mm
c)4 core 25 sq mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry and Finishing cable ends bysoldering with cable sockets and insulated tapes etc., includingsupplying sockets, soldering materials, tapes etc. and makingconnection to switch, BDB and BBC etc. of XLPE/PVC armoured cables as below :
a) 4 core 70 sq mm
b) 4 core 50 sq mm
c)4 core 25 sq mm
Straight through Jointing of cable of different size by compound kit including S&F ferrul, tapes and jointing materials (approved make)
i) 4 core 16-25 sqmm cable
ii) 4 core 70 sqmm cable
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25 mm size PVC rigid conduit 'FR' or (Precision make) incl. necy. fittings as required
a) 3x1.5 Sq mm(SPN DB to Switch Board)
b) 2x6 + 1x4 Sqmm (for SPN DB)
Distn. wiring with 1.1KV grade single core stranded copper conductor PVC insulated and unsheathed copper wire (approved make as to EIC) in 25mmx20mm/20x20mm PVC casing and capping or 19/25mm dia 3 mm thick PVC regid pipe complete with all accessories etc. embedded in wall (for VTPN to TPN DB, TPN DB to SPN DB, TPN DB to A.C point and for separate 15A plug point/Computer point and running meter for seperate plug point, coridoor light etc.)
a) 3x1.5 Sq mm
b) 2x2.5 + 1x1.5 Sqmm (for Power plug & Computer points.)
c) 2x6 + 1x4 Sqmm (for SPN DB)
d) 4x10 + 2x4 Sqmm (for TPN DB)
Supply & Laying of multi core following sizes PVC insulated copper U/A 1.1 kv grade flexible cable as ph, N & earth partly through fixed cable tray and partly through fixed u-PVC rigid pipe making holes etc as necessary mending good damages and painting for connection from TPN DB to AC, Gyser and computer board.
i) 3 core 6sq mm (for SPN DB)
S&F of required size solderless Cu socket of following Cu wires.
i) 6sq mm
ii) 4sq mm
iii) 10sq mm
iv) 2.5 sq mm
S&F 8 way Vertical TPN PBDB with 3 phase in coming & TP/SP outgoings, as follows with vertical type busbar system, in SS enclosure (IP-43 protection) (Legrand/Siemens/ABB) double door comprising of neutral link incl. & provision for earthing attachment concealed in wall after cutting the brick wall and mending good the damages to original finish incl. interconnection with suitable size of copper wires and earthing attachment. Incoming-415V, 36KA, 125A,4pole MCCB ,----1no Outgoing- 415V, 10KA, 63A T.P MCB C curve, ----7 nos 230V,10KA, 40A S.P MCB C curve,----3nos.
Supplying and fixing 415 V, 16-32A per way, TPN MCBDB with SS enclosure double-door with IP-42/43 protection with Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (make-Legrand/Siemens/ABB) as to GS.
a)6way, 63A FP isolator, & 18 nos. SPMCB
Supplying and fixing 250 V, 6-10A per way, SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (make-Legrand/Siemens / ABB) as to GS
a) (2+10) way, 40A DP Isolator 1 no, 10 nos. SPMCB
Distn. wiring in 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (approved make) in suitable size PVC casing- capping (precision make) complete with all accessories on surface in wall to light/fan/call bell points with modular type switch (make approved by EIC, ) fixed on metal flush box (modular type switch board) 8 or 9/12 module moduler white surrounds on wall incl. necy. connections and making earthing attachment flushed in wall incl. mending good damages to original finish
a)Avg. run 11mtr
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for earth strip and u-PVC pipe installation, per storey of building per vertical run
Labour Charges for dismanteling, uplifting and relaying the different sizes existing wires & cables into newly installed tray as per direction of EIC
Painting of Existing cable tray outside of each building by two cote, 1st cote by weather proof primer and second or final cote by approved weather cote paint (colour approved by the EIC)
Repairing of existing cable tray size upto 600mm with spot welding along with required sizes angle iron arrangement (40x40x6mm)
Spot welding of existing Earth strip terminal poits along with weather cote painting at different location as per direction of EIC
S. A. ENTERPRISE
ALPHA ELECTRICALS
Electromech Engineers Co-Operative Society Ltd.
T.D.K. ENTERPRISE
stage.html
html • 0.05 MB
technical_651697.pdf
PDF • 0.03 MB
techsummary_651697.pdf
PDF • 0.04 MB
finance_651697.pdf
PDF • 0.03 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_651697.pdf
PDF • 0.06 MB
Prov_niq-07-2021-22.pdf
PDF • 0.07 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .