| 1 | 1₹62.7 LAccepted-AOC 64 SHAHEED UDHAM SINGH MARKET NEAR OLD BUS STAND BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹68.7 L+₹5.0 L (7.91%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹70.8 L+₹7.1 L (11.2%)Rejected-Finance 261 BHARAT NAGAR BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹72.7 L+₹9.0 L (14.1%)Rejected-Finance 1000 PUDA MODEL TOWN PHASE 5 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 4 | Rejected-Finance Not Lowest | |
| 5 | 5₹73.0 L+₹9.3 L (14.7%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 5 | Rejected-Finance Not Lowest |
Tender Value
₹94.6 L
EMD Value
₹1.7 L
Closing Date
30 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
SPL REPAIR TO BLDG NO. P-04 AND P-10 (OTM ACCN) OF CORPS SIG REGT (AREN) AT BATHINDA MIL STN
2022_MES_541213_1
CWE BTD 8113/2022-23/E8
Open Tender
Civil Works
Item Rate
270 days
Bathinda
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE (North) Bathinda
₹1.7 L
Yes
6 Oct 2022
27 Jul 2022
1 Sept 2022
27 Jul 2022
30 Aug 2022
18 Aug 2022
27 Jul 2022 - 10 Aug 2022
Amount
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and pre cast concrete articles.
M & L for Brick work built in cement mortar 1:6 using sub class “B” brick built in one brick thick with old size bricks straight or curved on plan exceeding 6 m means radius complete all as specified..
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each complete.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each and removal from site complete all as specified.
Resecuring or easing and adjusting , without taking down shutters or any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each complete all as specified and as directed.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube, supplying and fixing in opening all as per specification and drawing.
S & F factory made solid PVC moulded door shutter with particle board core 28 to 30 mm thick (style) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam woodgrain colour PVC sheet on the front face and 2 mm plain colour PVC sheet on back face complete all as specified and directed by Eng-in-Charge.
S & F 150 mm long aluminium anodised, barrel tower bolts of extruded section.
S & F 100 mm mild steel butt hinges , medium weight, cold rolled complete.
S & F 150 mm aluminium handles, extruded alloy, fabricated type, anodised complete.
S&F factory made pressed steel frames of size 105 mm x 60mm for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc (thickness of MS sheet shall not be less than 1.25 mm), including making good the eall with plaster in CM 1:6 compete, all as specified.
S&F factory made pressed steel frames of size 125 mm x 60mm for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc (thickness of MS sheet shall not be less than 1.25 mm), including making good the eall with plaster in CM 1:6 compete, all as specified.
M & L cement concrete type C-1, 1:3:6 (20mm graded stone aggregate) as in filling of chowkhats, coping, packing around interlocking tiles and like complete all as specified.
S & F MS framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc, not exceeding 10 Kg each brackets, conforming to Fe 290 Gde E-165.(Brackets over 10 kg each to be measured under ' Structural Steel) cooler stand etc complete.
Cutting holes in brick walls built in cement mortar for inserting hold fast and making good dismantled portion in CM 1:3 or Cement concrete 1 : 2 : 4 , type B1 as required , depth exc half brick walls depth of embedded portion of holdfast or lugs measured from the face of the jamb into walls complete all as directed.
S & F 40mm thick flush shutters, solid core construction, with block board core and plywood face panels, decorative type sunmica (1 to 1.5mm thick) pasted on both sides and edges covered with waterproof beading complete all as specified and directed
S & F factory made glazed and skeleton shutters 35mm thick using second class hard wood open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc; sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24(a); all as specified complete.
M & L for prelaminated particle board, 18-19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, including wooden/ PVC beading all around of shutter fixed with screws to timber frame work complete all as specified.
S&F Continuous (piano) hinges, mild steel, bright finish or electro galvanised with flaps 30 mm width (when open) wide complete all as specified.
S&F 100 mm size Hasp and staple, safety type, aluminium anodised with MS hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with galvanized steel wire staples complete all as specified and directed.
S & F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed to door / steel window including necessary welding/ riveting/ bolting as required complete all as specified and directed.
S & F 300 mm long aluminium alloy anodised sliding door bolts with hasp and stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F floor door stopper 140 mm size of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed.
S & F 300 mm long MS ordinary rat tail rod pattern springs for doors including roller and roller plate complete all as specified.
S & F factory made steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat primer all as directed.
S & F factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, as fly proof shutters primer as directed.
S & F factory made fixed type steel ventilator with top hung shutter incl hinges steel pegs & stays complete all as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins / spring clips of size not exceeding 0.5 Sqm each pane and providing and fixing new ones with oil putty complete all as specified.
S & F sheet glass, 4mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified.
S & F sheet glass, 4mm thick frosted quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified.
S&F in repairs decorative fancy type curtain rod mild steel, chromium plated of 25 mm dia fixing with brackets, stops, rollers etc complete all as specified.
Demolition of cement concrete of any description and in any position not otherwise specific all provided for complete all as specified.
M&L for sunken treatment to sunken floor, cleaning the surface by using wire brush, rendering to floor and sides with 10 mm thick cement mortar (1:3) including mixing of liquid water proofing material @ 200ml per bag of cement, finished even and smooth without using extra cement after that material & labour for providing two coats of two components (one part liquid two parts powder) ready to use cementations water proofing coating on properly prepared surfaces by brushing having elongation of >50% for the applying water proofing treatment as per following on horizontal and vertical surfaces of sunken floor complete all as per manufacturers instruction. (i) Applying 1st coat of two components modified polymer coating. (ii) Provn of glass fiber mess of 2 x 2mm immediately on alone coating. (iii) Apply 2nd coat of two components modified polymer coating after 72 hrs on horizontal and vertical surfaces. Note :- WP Materials shall be measured and paid for separately.
M & L for applying two coats of Dr Fixit, pidecrte in sunken floor portion of toilet, bathroom, chajja, stair case etc proportion to be using of 1 ltr/ Sqm and applying by brush complete all as specified and as directed.
M & L for PCC (1:5:10) type E2 using 40 mm graded stone aggregate as in filling of sunken floor complete all as specified.
M & L for 25 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in floors for bases of sunken portion complete all as specified.
Dismantling of brick tiles or terracing tiles, single layer on roofs including removing the demolished material not exceeding 250 mtr away from site and disposal off in low lying area as directed.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness recovered or only a part there of) including removing the demolished material not exceeding 250 mtr away from site and disposal off in low lying area complete.
M & L rendering 15 mm thick C:M 1:3 mixing with WPC @ 200 ml per bag of cement on fair faces of concrete surfaces on roof slab after wire brushing and cleaning top surface on roof slab after wire brushing and cleaning top surface and finished even and smooth without using extra cement complete all as specified. (WPC shall be measured and paid separately)
M & L for providing cement concrete (1:2:4) Type B-0, using 12.5 mm graded crushed stone aggregate as in roof padding, levelling course, kerbs or mud stops, copings and levelling concrete slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer in charge.
M & L for wire brushing and cleaning top surface of tile, lime terracing or cement concrete, including flashings and junction of parapets etc and surface painting with a layer of blown bitumen of any penetration applied hot @ 1.70 kg/Sqm and priming surface and applying APP Based Polymeric membrane minimum weighing 3kg/Sq, and minimum 3mm thick reinforced with polyester non woven fabric ( wt not les than 150 gm/sqm) laid on primed surface by forced application as treatment for moderate conditions complete all as specified and directed.
M&L for 40 mm thick brick tiles laid over and including 15 mm thick screed bed in cement mortar (1:4) including grouted and flush pointed in CM 1:3 complete all as specified.
All as per item No. 44 here-in-before but except brick tiles ( old serviceable brick tiles to be reused after proper cleaning and washing)
M & L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in mud stops or roof kerbs etc complete all as specified.
Taking up or down 15mm bore galvanized iron tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20mm bore galvanized iron tubing and connections, including cleaning for refixing or removal to store complete all as specified.
S & F GI tubing medium grade ISI marked with all fittings and fixed to walls & ceiling or laid in floors, bore of pipe 15 mm complete all as specified
S & F GI tubing medium grade ISI marked with all fittings and fixed to walls & ceiling or laid in floors, bore of pipe 20 mm complete all as specified
Re-fixing old steel tubing and connections in new or old position to walls and ceilings or laid in floors 20 mm bore including connecting to tubes where ever directed complete all as directed.
M & L Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exceeding 20 cm girth, for brick walls complete all as specified and directed.
S & F in repair ISI marked 1000 ltr capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old water tank of any size and any type and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc all as directed.
S&F 20 mm dia of PTMT ball valves (minimum weight 210 grm) high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified.
S&F in repair 20 mm dia stop cock copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe complete all as specified.
S&F LDPE (Low density polyethylene) 40 mm bore pipes, ISI marked, confirming to IS, pressure rating @ 6 Kg/Sqcm, in any length , fixed to walls , ceiling with and including MS clamps or in floors including all fittings, heads, shoes, bends, swan necks, etc.
S & F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor and excluding flushing cistern, flush pipe and waste pipe complete.
S & F in repair vitreous china urinal of size 410x380x950 mm, half stall type, white with grating and union for discharge pipe excluding flushing cistern , flush pipe including CP urinal spreader and CP connection & waste pipe complete all as specified .
S & F in repair vitreous china wash hand basin, oval type of size 460mm x 310mmx 220 mm, counter sunk complete including waste, chain and plug and porcelain stopper. 32 mm dia waste coupling fancy type chromium plated, and PVC waste pipe of 32 mm dia and mild steel angle iron brackets and fixed all as directed complete .
S&F pillar cock swan neck CP fancy type of standard quality and size complete all as specified and as directed. Make Prayag, Cat Part No. 8114, KUP-35021PM in Jaquar or equivalent make mentioned in list of products.
S&F in repairs PVC low level cistern 10 ltr cap PVC valve less syphonic action type flushing cistern, low level, white with inlet, ball valve, float and handle including brackets and flush PVC pipe of low or high density or PVC 32 mm dia, for low level cistern complete all as specified
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified
S&F in repairs stop valves / angle valves , cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule for 15 mm bore dia of pipe complete all as specified.
S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints fix to steel pipe or union complete all as specified and as directed.
S&F in repairs 15mm bore, fancy type, chromium plated, concealed stop valve long shunk, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified.
S&F in repairs 15 mm bore bib taps, cast copper alloy with crutch or butterfly handle, fancy type, chromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as specified .
S & F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long including end brackets complete all as specified.
Taking down rain water pipe any size including all fittings including removal from site complete all as specified and directed.
S & F PVC (SWR) pipe 110 mm bore size for rain water pipe conforming to IS : 1984 incl standard PVC clamp & imbedded in PCC block incl jointing of pipes complete all as specified.
S & F 110 mm bore PVC bends ISI marked of any radius / shoe, fixed to PVC pipes all as directed.
S & F 75 mm dia CI floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1, complete all as specified.
S & F 125mm dia PVC (SWR) gully traps, setting and jointing with solvent cement, complete all as specified.
S & F in repair 100 mm dia cast iron soil waste & vent pipe drain pipes in any length with or without ears, with cement joints, fixed to wall including dismantling/ taking down old pipes, if required complete all as specified.
S & F in repairs 75 mm dia cast iron soil waste & vent pipe drain pipes in any length with or without ears, with cement joints, fixed to wall including dismantling/ taking down old pipes, if required complete all as specified.
S & F in repairs 100 mm CI connection socket to fit out let of WC complete all as specified.
S & F in repairs 100mm dia cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified.
S & F in repairs 100 mm CI cowls complete all as specified.
S&F stack clamps for 100mm dia pipe made out of 50 mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified.
Taking down cement plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M & L for rendering 15 mm thick on internal surface in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finishing the surfaces even and smooth without using extra cement complete all as specified.
M & L for rendering 10 mm thick on ceiling surface in cement mortar (1:3) on fair faces of brick work or concrete surfaces, finishing the surfaces even and smooth without using extra cement complete all as specified.
M & L 15 mm thick C:M 1:4 using WPC @ 200 ml per bag of cement on fair faces of concrete surfaces on roof slab after wire brushing and cleaning top surface on roof slab after wire brushing and cleaning top surface and finished even and smooth without using extra cement complete all as specified. (WPC shall be measured and paid separately)
M & L for rendering/ plasering 10 mm thick in cement mortar in (1:3) over 10 mm thick in cement mortar (1:4) as additional / floating coat on concrete surfaces of walls , chajjah , beams , ceiling etc even and smooth without using extra cement complete all as specified.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash etc complete all as specified.
M&L for preparing old plastered surfaces of ceiling and applying one coat of white wash etc complete all as specified.
M & L for preparation of newly plastered surfaces walls and apply two coats of oil bound distemper over a coat of wall care putty including M & L for 2 mm thick wall care putty on plasered surfaces preparatory to distempering compete all as specified.
M & L for applying two coats of oil bound distempering on old plastered surfaces of walls, over a coat of wall care putty ( 2mm thick) after complete removal of existing treatment including preparing surface compete all as specified. Note:- Cost of M & L for wall care putty and complete removal of existing treatment is included in this item. Nothing extra shall be paid on this account.
M & L for preparation of new plastered or unplastered surfaces of walls and applying two coats of exterior water base emulsion paint complete all as specified.
M & L for complete removal of old decorated surfaces of walls by brooming down or steel wire brushing scrapping down smoke soot, moulds, moss and efflorescent, salts and treating oil and greasy spots and applying two coats of exterior water base emulsion paint over a coat of primer on walls complete all as specified.
Supply only liquid water proofing compound complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish to a distance exc 1 km but not exc 2 km away from site complete all as specified
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar.
M & L for vitrified ceramic tiles, 10 mm thick (square / rectangular) polished, area of each tile not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 15 mm thick screed plaster in CM (1:6) complete all as specified and directed.
M & L for vitrified ceramic tiles, 10 mm thick (square / rectangular) in skirting, dados etc, polished, area of each tile not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 10 mm thick screed plaster in CM (1:4) complete all as specified and directed.
M & L for non skid ceramic coloured tiles, 7 to 8 mm thick (square / rectangular) in floor area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including 15 mm thick screed bed of motor (1:4) complete all as specified.
M & L for glazed ceramic coloured tiles 450 x 300 mm, 7 to 8mm thick in vertical surfaces such as dado / skirting, set and jointed in neat cement slurry over and including 10 mm thick plaster in cement mortar (1:4) pointed with white/ coloured cement to match complete all as specified.
M & L for machine cut kota stone slab 18-22 mm thick as in flooring, including 50mm wide white marble strips all around of rooms/ verandah, over and including M & L for 15 mm thick screed bed in CM 1:6 etc set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M & L for machine cut kota stone slab 18 to 22 mm thick as in riser of steps, skirting , dado over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing laid over and including M & L for 10 mm thick plaster in CM 1:4 complete all as specified.
M & L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M & L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified.
M & L for preparation of new or previously untreated wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint ( ordinary tint) over a coat of pink primer complete all as specified.
M & L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified.
Demolition of (PCC) cement concrete of any description in ground floor and in any position not exceeding 15 cm thickness complete all as specified.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection/ sub base of interlocking tiles etc, including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for ISI marked factory made machine pressed precast concrete interlocking paver block 60 mm thick with grey cement and no pigment, factory made, any shape and size, conforming to IS 15658-2006, made out of M-35 grade concrete laid over and including M & L for 25 mm thick layer of sand complete all as specified.
M&L Welding in repairs, not exc. 6mm thick metal and not exc 2.50cm in length complete.
Demolition of RCC of any description & in any position not otherwise specifically provided for, complete all as specified.
M & L for RCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate in chajjas, lintel etc complete all as specified.
M & L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia Fe-410 complete all as specified.
M & L for Use and Waste of form work to soffits and sides of chajjas and similar work of fair finished surface of concrete etc complete all as specified.
S&F in repairs 1mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as directed.
M & L for applying 2 mm thick one coat of white wall care putty on walls complete all as specified.
M&L for granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, counter, shelves and line in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed in CM 1:4 and moulding on edges by grinding complete all as specified.
M & L for precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in landings, cover slabs (for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) complete all as specified.
Excavation in trenches in soft / loose soil not exc 1.5 mtr wide and not exc 1.5 mtr deep for pipes / foundation etc for laying cable, shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr depth and getting out in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading , leveling, watering and well ramming in layers each not exceeding 25cm thick in soft / loose soil complete all as specified and as directed.
Removing excavated soil to a distance exceeding 250 mrtres but not exceeding 500 metres and depositing where directed complete all as specified.
Demolition and breaking up any size drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified.
M & L 150 mm bore dia salt glazed stoneware drain pipes, laid in trenches and, jointed in cement mortar all as specified and as directed.
M & L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in bed to drain pipe 150mm bore (internal) dia including packing under and hunching against the sides of pipes after they are laid and tested complete all as specified..
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling, sub base and mass concrete complete all as specified.
M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) for flat rough surfaces of concrete complete all as specified.
M & L for reinforced cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the like, finished exposed surface fair and even complete all as specified. (Reinforcement and form work shall be measured and paid separately)
S & F in repairs 75mm dia cast iron bends (any radius), diminishing pieces or tapers (large bore measured) complete all as specified.
M & L for second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exceeding 6 Sqcm and not exceeding 25 Sqcm.
M & L 100 mm thick cement concrete 1:4:8 , type D-2 ( 40 mm graded stone aggregate) as in sub base of floors, interlocking tiles complete all as specified and directed.
S & F 100 mm long stainless steel butt hinges, medium weight complete all as specified and directed.
S & F in repairs vitreous china wash down water closed pan ( pedestal Pattern), white ( excluding fixing bolts, flushing cistern and flush pipe) and including plastic seat cover complete all as specified and directed.
S&F health faucets CP with 1.00 mtr long CP flexible pipe and hook fixed complete all as specified and as directed. Make Prayag, Cat Part No. BEA-95 or equivalent in any of the make mentioned in list of product.
S & F 20mm UPVC pipe of standard quality including accessories like union, bend, tee, socket and solvent, fixed in walls or trenches including cutting in brick wall or concrete complete all as specified and directed by Eng-in-Charge.
M & L for brick work with sub class 'B' (old size brick) straight or curved on plan to any radius in half brick thick walls, bult in CM 1:4 complete all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, light fittings etc except concealed conduit and sunken boxes and removing the retrieved materials from site including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed.
M & L for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including M & L for PVC concealed conduit not less than 20mm dia (medium duty ISI marked) and conduit fittings with and including M & L for 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 136 here in before but for one socket outlet 5 pin, 5/6 Amp 250 volts flush type on same board complete all as specified.
All as per item No 136 here in before but for one socket outlet 5 pin, 5/6 Amp 250 volts flush type on independent board but not below the switch board complete all as specified.
All as per item No 136 here in before but for one light point controlled by two way switch complete all as specified.
All as per item No 136 here in before but for one socket outlet 6 pin, 6/16 Amp 2 in 1 with cable 2.5 sqmm multistranded copper conductor FRLSH cable on the independent board including provn of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continues as earth wire connected to earth dolly complete all as specified.
S &F switch piano flush type with frame cover 5/6 Amp, ISI marked 230V AC, single pole, one way complete as specified.
S &F switch piano flush type with frame cover 5/6 Amp, ISI marked 230V AC, single pole, two way complete as specified.
S &F switch piano flush type with frame cover 15/16 Amp, ISI marked 230V AC, single pole, one way complete as specified.
S & F socket outlet 5 pin, 5/6 Amp multi purpose with frame cover, 2 in 1, flush type complete all as specified.
S & F socket outlet 5 pin, 15/16 Amp multi purpose with frame cover, 2 in 1, flush type complete all as specified.
S & F ceiling rose surface type polycarbonate, isolated body two to three terminal, T P line series 20x50mm, 6 Amps complete all as specified.
S & F stepped type electronic fan regulators flush socket type complete all as specified.
S & F lamp holder PVC/Polycarbonate type with back plate suitable for batten fitting with LED bulb , 9 watt complete all as specified.
S & F in repairs wall mounted LED retro fitting tube light 1 x 20 watt, 6000 K min 100 lumen per watt, 4 ft complete with decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate environment friendly , energy efficient complete with all light fittings connections all as specified and directed .
M & L in repairs for LED mirror light fitting of 09/10 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete lamp and all other accessories fitting arrangement including connecting to electric point by using flexible copper wire twin core upto ceiling rose/ connector complete all as directed.
S&F in repairs new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP 66 roadway luminair with high power LED of 25/35 watt toughened glass complete with GI bracket (01 No) MS clamps (02Nos) suitable for security light fitting fixing to wall/column & electrical connection to the light fitting providing 1.5 mtr long twin core round copper conductor cable of suitable size and testing compete all as specified.
M&L for sub main wiring with 2 single core cable 6 sqmm, 1100 volts grade PVC insulated unsheathed of copper multi standard conductor FRLSH cable with continuous copper earth conductor of size 6 sqmm, 1100 volts grade drawing through in & including existing PVC concealed / surface conduit of size 20 mm including taking down old unserviceable sub main wiring complete all as specified. Note :- Two runs of cable and one run of earth wire shall be measured as one unit.
M&L for wiring complete with 2x6 Sqmm (nominal area) PVC insulated copper conductor FRLSH cable (ISI marked) in and including PVC concealed conduit ( medium quality ISI marked ) and cutting of chases in wall including 6 sqmm single core copper earth wire to common earth and connecting to earth dolly complete all as specified incl taking down old sub main wiring of any size and type complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, IP-43 protection, 12 way, TPN 415 Volts AC with 200 Amps rated bus bar dust and vermin proof suitable for incorporation of MCBs and isolators etc including taking down old unserviceable DB complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, IP-43 protection, 8 way, SPN 240 Volts AC with 200 Amps rated bus bar dust and vermin proof suitable for incorporation of MCBs and isolators etc including taking down old unserviceable DB complete all as specified.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, IP-43 protection, 4 way, SPN 240 Volts AC with 200 Amps rated bus bar dust and vermin proof suitable for incorporation of MCBs and isolators etc including taking down old unserviceable DB complete all as specified.
S & F in repairs MCCB 4 pole of rating 100 Amps , Icu 16 KA thermal magnetic based complete all as specified.
S & F in repairs MCB SPN 63 Amps, 10 KA 'C' Curve, 230 Volt, AC, 50 Hz including necessary attachment including taking down old unserviceable MCB TPN complete all as specified.
S & F in repairs MCB SP 6 to 32 Amps, 10 KA, 240 Volt, including taking down old unserviceable MCB SP complete all as specified.
S & F of Exhaust fan 450 mm sweep with louvers, single phase 230V, AC supply, metallic body heavy duty, Aerodynamically designed having noise level not exceeding 45-50 mm DB, hanging on wall with 4 Nos steel fastners 10 mm dia and 10 cm long and making good the disturbed surface as per existing surfaces and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Eng-in-Charge.
Taking down ceiling fan from cable ends at site, dismantling blades and removing fan and blades to store and refixing (hanging ) the same after completing the repair work of the building and connecting up including provn of flexible copper cable from ceiling rose or connector to fan complete all as specified. Note:- If any damages of fans at the time of transportation / deposit to store occurs, the contractor will responsible for the same and he will make good the fan without any extra cost to department.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion including taking down old existing earthing of any type. Note :- (a) PCC chamber shall be constructed at least 1.5 m away from earth pit. Pipe for watering shall be provided in slanting manner. (b) 4mm dia GI wire and 15mm dia light grade GI protection pipe upto 7.5 metre shall deemed to be included in quoted rate.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
Ajay Enterprises
Surindera Kumar Bansal
M/s Kamal Builders
M/s MITTAL CONSTRUCTIONS
M/s Balvinder Singh Engineer and Contractors
R K GOYAL & COMPANY
M/s GURFATEH BUILDERS
KULWANT RAI
M/S VERMA BUILDERS & DEVELOPERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .