GE 863 EWS
GE 863 EWS C/O 56 APO
REPAIR MAINT OF EXTERNAL ELECTRIFICAL SUPPLY SYSTEM AT KHAB NAMGIA DOGRI IN THE AREA OF AGE EM WE POOH UNDER GE 863 EWS
2021_MES_498606_1
GE863/EWS-T-70 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
kHAB AND NAMGIA DOGRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE 863 EWS
₹19,968
Yes
11 Mar 2022
31 Dec 2021
10 Feb 2022
31 Dec 2021
8 Feb 2022
18 Jan 2022
60 days
Amount
Distmentling old unservicable LT Panel with MCCB/MCB SPN&TPN form the plateform complete all as specified and directed by Engineer-in-Charge
Distmentling/ disconnecting existing unserviceable ACSR conductor of any type all as specified and directed by Engineer-in-Charge
Distmentling/ disconnecting existing unserviceable earthwire/ steel wire of any size, all as specified and directed by Engineer-in-Charge
Distmentling/ disconnecting existing unserviceable insulator of any type and size, all as specified and directed by Engineer-in-Charge
Distmentling/ disconnecting existing unserviceable cross-arms of M.S. channel or angle sections of any type and size, all as specified and directed by Engineer-in-Charge
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 10 sqmm , 02 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, including taking down unserviceable cable from trenches or any location also taking down cable cover , pipes etc if any, complete all as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 16 sqmm , 02 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, including taking down unserviceable cable from trenches or any location also taking down cable cover , pipes etc if any, complete all as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 10 sqmm , 04 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, including taking down unserviceable cable from trenches or any location also taking down cable cover , pipes etc if any, complete all as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 16 sqmm , 04 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, including taking down unserviceable cable from trenches or any location also taking down cable cover , pipes etc if any, complete all as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 35 sqmm , 3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, including taking down unserviceable cable from trenches or any location also taking down cable cover , pipes etc if any, complete all as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 70 sqmm , 3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, including taking down unserviceable cable from trenches or any location also taking down cable cover , pipes etc if any, complete all as specified and directed.
Supply and Fix terminal box , made out of PVC with hinged door and locking arrangements of size 240x130x95 mm including four way connector, fixed on pole with necessary clamps complete all as specified and directed . Make Sintex, Cat No- GSJB-2014 or Equivalent
Supply and fixing in repair SPN, MCBs 6 Amps, 415V, complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etc all as directed by Engr-in-charge.
M&L for laying dry bricks old size with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight trench for protection of cable all as specified and directed
Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. Note- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning.
Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete (1:4:8) type D2 with 40 mm graded aggregate for poles / stays foundation all as directed by Engr- in - Charge.
M&L for cement concrete (1:3:6) type C1 with 20 mm graded aggegate for pole coping & road crossing including form work and finishing to all exposed surfaces by using extra cement all as directed.
Material and labour for GI pip 40 mm dia"light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection and including removing old unserviceable item complete all as specified and directed. Make :- Jindal/Tata/BST
Supply and fix in replacement of on load change over switch , 4 poles with side handle, 415 volt AC, 50/60Hz, 63 Amps with suitable sheet metal enclouser, complete all as specified and direct by Engineer-in-Charge.
Supply and fix in replacement of on load change over switch , 4 poles with side handle, 415 volt AC, 50/60Hz, 100 Amps, with suitable sheet metal enclouser ,complete all as specified and direct by Engineer-in-Charge.
Removing and dismentalling old U/S over head line conductor ACSR of any size ( 4 line per pole) and then cleaning and restringing in original position incl binding with new aluminium conductor all as directed by Engr-in-Charge. Note : - The rate quoted are inclusive of (a) cutting/ remove all tree branches/vegetation arround 3 mtr of distance from the pole. (b) Length of 4 run as a whole shall be measured as a unit length for payment purpose. (c) Adjusting & tightingof stay assembly wherever required.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint complete all as specified and directed.
M&L of galvanised steel wire 4 mm dia/ 8 mm dia, for guard wire , continuous earth wire complete all as specified and directed.
M&L for pin type, porcelain vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65mm dia for 1100 volts grade, complete all as specified and directed.
S&F shackle type porecelain vitreous white brown or green insulator for working pressure 1100 volts of 90mm dia and 75mm height incl galvanised steel straps of 31x3 mm size insulator and 12 mm dia bolt, washer & nuts complete all as specified and directed.
S&F synthetic line separators of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for single phase 2 wire LT lines all as directed by Engr-in-Charge.
S&F synthetic line separators of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for single phase 4 wire LT lines all as directed by Engr-in-Charge.
Supply and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m , complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.
A P ENTERPRISES
R B TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .