Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹19.9 L+₹1.2 L (6.30%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹21.3 L+₹2.6 L (13.8%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L3 | Rejected-Finance Highest bid quoted | |
| 4 | L4₹24.9 L+₹6.2 L (33.3%)Rejected-Finance NOT FOUND | L4 | Rejected-Finance Highest bid quoted | |
| 5 | L5₹25.0 L+₹6.3 L (33.4%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L5 | Rejected-Finance Highest bid quoted |
Tender Value
₹41.0 L
EMD Value
₹82,000
Closing Date
19 May 2020, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
REPAIR/MAINT OF ELECTRICAL APPLIANCES AT SUB STATIONS INCLUDING REPLACEMENT OF CAPACITOR CONTROL SWITCH, STREET LIGHT WITH LED FITTINGS, EARTHING PITS ETC AT CERTAIN OTM ACCN AND RESIDENTIAL AREA AT AF STN RAJOKRI OF GE (AF) GURGAON
2020_MES_337357_1
GE/GUR-/NIT-64/2019-20
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹82,000
Yes
16 Jul 2020
3 Apr 2020
20 May 2020
3 Apr 2020
19 May 2020
17 Apr 2020
Amount
Comprehensive maintenance of oil cooled servo voltage stabilizer by isolating, disconnecting of input/output, supply cable, opening of top of voltage stabilizer, detecting of fault, u/s component in control panel /dimmer stat /PCB etc, cleaning of serviceable parts/ component, including replacement of worn out spare parts etc, if required all as directed. Note:- Cost of replacement of worn out cable for wiring shall deemed to be included in quoted unit rate.
Voltage stabilizer of capacity 25 KVA three phase
Voltage stabilizer of capacity 75 KVA three phase
Voltage stabilizer of capacity 300 KVA three phase
Voltage stabilizer of capacity 450 KVA three phase
M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration, filtration and replacement of silica gel all as directed Note:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the dept. Test report to be submitted after completion of Job.
Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as directed Note:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site.
M&L for defect rectification of HT 11 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV complete all as directed
Supply, jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 120-185 Sqmm XLPE cable of 11000 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG)
Supply, jointing and testing outdoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG) Note for Item Nos. 5.00 to 6.00:- Cost of cutting of existing end termination joint shall deemed to be included in quoted unit rate.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 95 Sqmm and laid in trenches/ ducts/ pipe or on poles complete all as specified and as directed.
Ditto all as per item No. 7 described here-in-before but size 3.5 core X 50 Sqmm
Ditto all as per item No. 7 described here-in-before but size 3.5 core X 35 Sqmm
Ditto all as per item No. 7 described here-in-before but size 4 core X 25 Sqmm
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables, pipes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soils complete all as specified and as directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for boring/auguring suitable hole & insertion of 65 mm dia GI pipe including pipe not less than 600 mm below existing PCC/ road/ hard standing complete all as directed. Notes :- Cost of equipment, tools & plants & material required for boring shall deemed to be included in the quoted rates .
M&L for sand cushioning for cable protection in trenches complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
Taking down the existing cables from trenches of any size complete all as directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6mm thick buried directly in ground vertically not less than 4m below normal ground level with the top edge of the earth plate not less than 3.25 m below the normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron earth strip 25x4 mm means of galvanised iron bolts, nuts, check nuts and washers and earth strip protected by galvanised iron pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore light grade for watering including test point 75x75x25mm all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing on completion complete all as specified and as directed.
Comprehensive maintenance of transformer by isolating, disconnecting of input/output, supply cable, opening of top of transformer, detecting of fault, u/s component etc, cleaning of serviceable parts/ component, including replacement of worn out spare parts etc, if required complete all as directed.
Transformer 300/400 KVA
Transformer 160/250 KVA
Transformer 50/75/100 KVA
Taking out of VCB trolley from HT Control Panel 11 kV, 3 phase, 630 Amp, 18.4 kA (Make CG) and cleaning the trolley with CRC removing all dust, carbon etc greasing the mechanical parts, gears lever charging, male female contact and spring holder & material and labour for calibration of IDMT numerical relay as per existing load for earth fault, over current, short circuit including setting the relay on required electric load and testing on earth fault, short circuit and over load with the help of relay testing kit including replacement of all fuses with existing rating complete all as directed.
M&L for maintain earthing pit complete with copper earth plate electrode size 600 x 600 x 3.15mm thick buried directly in ground vertically not less than 4m below normal ground level with the top edge of the earth plate not less than 3.25 m below the normal ground level by filling surrounding all sides by mixture of charcoal and common salt and replacing copper earth strip 20X 3 mm means of copper iron bolts, nuts, check nuts and washers and earth strip protected by galvanised pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore light grade for watering all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing to get required result on completion of maintenance complete all as directed.
Taking down and dismantling HPSV street light fitting for 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as directed.
Taking down of worn out PVC insulated copper cable 1.5 sqmm from street light fitting to junction box including conduit pipe complete all as directed.
M&L for wiring PVC insulated, stranded sheathed copper cable conductor size 1.5 Sqmm 3 core and drawing through and including S&F steel rigid conduit not less than 20mm dia and fixed on pole including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable connected to earth including connecting to earth dolly complete all as specified and as directed.
Supply and fix LED street light luminaries IP-66 grade of protection with 24 High power LED of 45 watt rating and extendable up to 48 watt rating with unique peanut lens to ensure uniform distribution complete all as directed. Make: CG or its equivalent in Wipro/ Havells/ Surya
M&L for bracket for street light fitting made of 40mm bore light grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc complete all as directed
Supply and fix in replacement of steel weather proof, dust proof, duly powder coated street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as directed. Make : Hensel/Sintex/Universal Switch Gear control Note:- The rates quoted shall inclusive of provision and fixing of suitable lugs and glands for cable connection.
Supply and fix in replacement of automatic timer switch panel mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as directed. Make : Kakatiya/Healer/Bajaj. Note:- (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr shall deemed to be included in the unit rate. (ii) Provn of glands and lugs shall deemed to be included in the quoted rate.
M&L for rewinding of fans with same gauge of super enamelled copper wire complete varnishing, baking, connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with knots /bolts/ washer /split pin and blade screws etc testing, complete all as directed :-
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Supply and fix in repair new metal bush bearing made out of gun metal/ brass of same size suitable for ceiling fans, wall mounted fan and exhaust fans complete all as directed.
Supply and fix in repair ball bearing suitable for the following fans: Make: NBC/SKF/Tata
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Supply and fix in repair capacitor 2.5 mfd, 400 volt, 50 Hz complete all as directed. Make : Tibcon
Supply and fix in repair capacitor 4 mfd, 400 volt, 50 Hz complete all as directed. Make : Tibcon
S&F MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as directed
S&F MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA complete all as directed
S&F MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as directed
S&F MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as directed
Supply & fix anti climbing devices; comprising 3 Rows of 2.24 mm galvanized steel 2 stranded barbed wire with 2.00 dia barbs wrapped spirally on L Type angle frame of length 30cm to 50 cm (Facing downward) with angle size 50mm x50mm x5mm including nut bolts, clamps for fixing on round steel tubular/PCC pole complete all as specified & as directed
Supply & fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified & as directed
Comprehensive maintenance of Capacitor bank panel by isolating, disconnecting of input/ output, supply cable, detecting of fault, u/s component in panel ,cleaning of serviceable parts/ component, including replacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock, replacement of old wiring with 2.5 sqmm to 6 sqmm etc, if required complete all as directed. Note:- Replacement of Capacitor of various size shall be measured & paid separately
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 5 KVAR complete all as directed
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 10 KVAR complete all as directed
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 15 KVAR complete all as directed
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 20 KVAR complete all as directed
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 25 KVAR complete all as directed
S&F in repair of Warrior HD Plus Super heavy duty plus cylindrical capacitor with clamp 440 Volt, 50 Hz, Capacitor 50 KVAR complete all as directed
Comprehensive maintenance of EMF panel by isolating, disconnecting of input/output, supply cable, detecting of fault, u/s component in panel, cleaning of serviceable parts/ component, including replacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock etc, if required all as specified and directed. Replacement of Contactor, relay, WLC, replacement of old wiring with 2.5 sqmm to 6 sqmm etc. of various size shall be measured & paid separately
Supply and fix in replacement of 32 to 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts, complete all as directed. Make: L&T/ Schneider/ Havells
S&F of 3 phase water level controller, 415 Volt, 50 Hz complete all as directed.
S&F of 3 phase phase protector relay, 415 Volt, 50 Hz complete all as directed.
S&F of 3 phase single line preventer 415 Volt, 50 Hz complete all as directed.
Supply, install, testing, commissioning and testing in replacement factory made feeder pillar compartmentalised outdoor type, weather proof, dust and vermin proof double door front and rear openable made out of 3.15 mm thick CRCA sheet and angle iron 45x45x 6mm duly powder coated, suitable for floor /platform mounting of CPRI certified and IP65 class suitable for 415 volt, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars of rating 900 Amps installed on porcelain /SMC insulator with apron for cable entry, closing locking arrangement with and including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS 694 marked, 1100 volt grade of appropriate size (but not less than 2.5 sqmm ) and comprising of the following Incoming :- (a) ACB 415, 4 pole, 600 Amp, 50 Hz micro processor based release unit type MP4 LSIG draw out type specially fix for incoming supply with overload short circuit and earth fault protection (service breaking capacity 50 KA with spring loaded liver & key locking in drawn out position with under voltage release and motor operating system for charging as well as manual charging coil complete all as specified and directed - 01 No
M&L for defect rectification of LT 1.1 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 1.1 KV complete all as directed
Supply, jointing and testing indoor/outdoor type cold shrinkable straight through cable joint including all material and accessories suitable for 3.5 core X 50-95 Sqmm XLPE cable of 1100 volts (E) grade complete all as specified and as directed. (Make / Model - Birla 3 M Ltd, Raychem RPG) Note :- Cost of cutting of existing end termination joint shall deemed to be included in quoted unit rate.
Supply and fix in replacement of Lead acid maintenance free Battery 12 Volts 120 AH of existing type & size suitable for DG Sets. Make : EXIDE/AMCO including initial charging.
J B Electricals
M/S Anand Enterprises
shiv shanker enterprises
Commercial Traders
PARKASH ENTERPRISES
Saini Enterprises
M/S Sanjay Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .