Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.4 L+₹2.0 L (8.84%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
1 Jun 2023, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri GanganagarCantt Rajasthan-335001
REPAIR AND MAINT OF PUMP SETS AT STP INSTALLATION AND ALLIED WORK AT MIL STN SRI GANGANAGAR
2023_MES_590441_1
GE SGNR/TOK-21 OF 2023-24
Open Tender
Pumps/Motors
Item Rate
270 days
Sri Ganganagar(Raj)
D Class a(ii) and for un-enlisted, refer NIT para 8.
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹54,000
Yes
4 Jul 2023
20 Apr 2023
3 Jun 2023
20 Apr 2023
1 Jun 2023
2 May 2023
Amount
Periodical cleaning i.e. drainout of water and removing of sludge (appx 0.60 m thick layer of sludge) and cleaning of Equalization tank of size 14.40 Mtr dia and 3 Mtr deep and removal of sludge to a distance not less than 50 m from the tank complete all specified and directed by Engineer-in-charge.(After every 4 months)
Periodical cleaning i.e. Drainout of water and removing of blockage of Grit Chamber of size 1.0 x 3.0 x 1.3 m and removal of sludge (approx 0.5 m thick layer) to a distance not less than 50 m from the tank complete all specified and directed by Engineer-in-charge. (After every 4 months)
Periodical cleaning i.e. Drainout of water by connecting pump set and manually, removing of sludge (appx 0.6 m thick layer) and cleaning of filter feed tank and removal of sludge to distance not less than 50 m from starting point complete all as specified and directed by Engineer-in-Charge. (After every 4 months)
Periodical cleaning i.e. Dewatering and cleaning of Sludge sump by removing of sludge (appx 0.5 m thick layer of sludge) by manual/lift and cleaning of Sludge Sump of size 2.2 Mtr x 2.5 Mtr and 2 m deep including removal of sludge to distance not less than 50 m from tank complete all as specified and directed by Engineer-in-Charge. (After every 6 months)
Periodical cleaning i.e. Drainout of water and removing of sludge (appx 0.6 m thick layer of sludge) and cleaning of claritube setter tank of size 10.2 m dia and 3.5 m deep and removal of sludge to a distance not less than 50 m from tank cleaning of rockers and channels complete all as specified and directed by Engineer-in-Charge. (After every 4 months)
Periodical cleaning i.e. Drainout of water by connecting pump set and manually, removing of sludge (appx 0.50 m thick layer) and cleaning of chlorine contact tank of size 6.8 m dia and 3 m deep and removal of sludge to distance not less than 50 m from starting point complete all as specified and directed by Engineer-in-Charge. (After every 4 months)
Periodical cleaning i.e. Drainout of water by connecting pump set and manually, removing of sludge (appx 0.60 m thick layer of sludge) and cleaning of treated water storage tank of size 20m dia and 3 m deep and removal of sludge to distance not less than 50 m from starting point complete all as specified and directed by Engineer-in-Charge. (After every 4 months)
M&L for cleaning of Solid sludge Drying bed of size 7.5 m x 7.5 m and 1.5 m depth by removing solid sludge (approx 0.3 m thick layer of sludge) from sludge drying beds by manually and removing to a distance not less than 50m from starting point complete all as specified and directed by Engineer-in-Charge. (After every 4 months)
Drainout of water by connecting pump set and manually, removing of all sludge, taking out motor/pump to outside, cleaning of well of pump house or sewage tank, removal of sludge to minimum distance of 50 m from starting point, plastic based water proof paint inside tank, lowering motor/pump inside with all connections, re-make roof same as existing with all joinery items including connections with complete all as specified and directed by Engineer-in-Charge.
Taking up unserviceable openwell submersible pumpset vertical type 3 phase, 21 KW/28 HP, Make- KSB, from sewage sump 11 meter below ground level. Transportation it to authorised KSB workshop for repair of pumpset complete all as specified and directed by Engineer-in-Charge. Note : T&P required for taking up and refixing of pumpset and minor items required at site deemed to be included in quoted rate and spares required to make the submersible pumpset functional shall be measured and paid separately as supply only Under respective items of BOQ.
Supply only mechanical seal as per existing model of pumpset complete all specified and directed by Engineer-in-Charge. .
Supply only bearing No 6314/C3 complete all specified and directed by Engineer-in-Charge.
Supply only chamber Oil SAL1BW40 complete all specified and directed by Engineer-in-Charge. .
Lowering of submersible solid handing sewage submersible pump Model : NS 50/26N Head 9m, flow - 54 cum/hr Capacity 3.7 KW/ 5 HP, from 3m deep tank for repair by replacement of spares, reassemble and fixing at original position making mechanical and electrical connection and testing making water proof joint of submersible cable including replacement of rusted nuts, bolts, rubber gasket and clamp including transporting from workshop after repair complete all as specified and directed by Engineer-in-Charge. Note for repair of Plant and Machinery : (a) The cost of "To and from" transportation of pump, motor and other plant etc from installation to workshop for repair shall deemed to be included in quoted rate. (b) Cost of grease shall deemed to be included in quoted rate. (c) Spares will be measured and paid for separately under respective items of BOQ as supply only .
Lowering dismantling and taking up from 11m deep tank unserviceable solid handing sewage transfer submersible pump Model : NS 80/26Q, Head 15m, flow - 102 cum/hr, Capacity 9.3 KW/ 12.5 HP, repair the unserviceable pump by replacing unserviceable spares, reassemble and fixing at original position making mechanical and electrical connection and testing complete all as specified and directed by Engineer-in-Charge. Note for repair of Plant and Machinery : (a) The cost of "To and from" transportation of pump, motor and other plant etc from installation to workshop for repair shall deemed to be included in quoted rate. (b) Cost of grease shall deemed to be included in quoted rate. (c) Spares will be measured and paid for separately under respective items of BOQ as supply only .
Supply only non clog impeller suitable for Model No. NS - 80/26Q all as specified and directed by Engineer-in-Charge.
Supply only non clog impeller suitable for Model No. NS - 50/26N all as specified and directed by Engineer-in-Charge.
Supply only Bearing No. - 6309 all as specified and directed by Engineer-in-Charge.
Supply only Bearing No. - 6306 all as specified and directed by Engineer-in-Charge.
Supply only Silicon carbide Mechanical Seal (inboard) and Carbon or SS Mechanical Seal (outboard) all as specified and directed by Engineer-in-Charge.
Supply only Lubricating oil all as specified and directed by Engineer-in-Charge. Make :- IOCL, HPCL, BPCL
Taking out outlived MBBR media of sewage treatment plant and supply and fill fresh MBBR media - small cylindrical shaped polyethylene carrier having specific gravity between 0.94 and 0.96 and refilling after cleaning complete material as per existing complete all as directed by Engineer -in - Charge .
Taking out and rewinding of non clog submersible electric motor 3 phase of Capacity 3.7 KW/ 5 HP, Model No. - NS 50/26N Make - Kirloskar with super enamelled copper winding wire of existing gauge and weight, varnishing and drying complete all as specified and directed by Engineer-in-Charge
Taking out and rewinding of non clog submersible electric motor 3 phase of Capacity 9.3 KW/ 12.5 HP, Model No. - NS 80/26Q Make - Kirloskar with super enamelled copper winding wire of existing gauge and weight, varnishing and drying complete all as specified and directed by Engineer-in-Charge
M&L for taking out non clog submersible pumpset - 06 Nos installed in sewage sumps (11 meter deep) of cap 9.3 KW/ 12.5 HP 3 phase and cleaning the blockage of pump and refixing on original position and testing complete all as specified and directed by Engineer-in-Charge.
M&L for taking out non clog submersible pumpset installed in Equalization tank of Sewage Treatment plant (3 meter deep) of cap 3.7 KW/5 HP 3 phase and cleaning the blockage of pump and refixing on original position and testing complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of openwell submersible electric motor 21 KW/28 HP rewinding with super enamelled copper winding wire of existing gauge and weight, varnishing and drying complete and replacement of bearing (as per existing). Reassembling, bringing back to the installation, making the same functional after re-fixing at the existing location and type as existing and assembling complete so that cap of motor should not be changed complete all as specified and directed by Engineer-in-Charge.
M&L for general periodical servicing of twin lobe air blower Model No. : UR 160 H coupled with 25 HP 3 Phase induction motor by replacement of fan belts, unserviceable spares, testing and making alignment of V belt complete all specified and directed by Engineer-in-Charge. (After every 4 months) Make : Usha Compressor Note : (a) Cost of grease shall deemed to be included in quoted rate (b) Spares will be measured and paid for separately under respective items of BOQ as Supply only
Supply only lub oil ENKLO E-320 of all specified and directed by Engineer-in-Charge. MAKE IOCL or equivalent in, HPCL,BPCL
Supply only V belt SP-2410/B-93 suitable for Make : Usha Compressor , air blower model UR-160H all specified and directed by Engineer-in-Charge. Make : Fenner/Usha/ Dunlop
Disconnecting electric connections, taking up squirrel cage induction electric motor 415/440 V, 50 Hz, 2 pole pairs per phase, 1475 RPM, of capacity 25 HP electric motor (for air blower) from the existing foundation. Transportation to workshop for repair & rewinding with super enamelled copper winding wire of existing gauge and weight, varnishing and drying complete. Reassembling, bringing back to the installation, making the same functional after refixing at the existing location, testing the motor on full load complete all as specified and directed by Engineer-in-Charge.
Disconnecting electric connections, taking up squirrel cage induction electric motor 415/440 V, 50 Hz, 2 pole pairs per phase, 1475 RPM, of capacity 12.5 HP electric motor (for feed pump) from the existing foundation. Transportation to workshop for repair & rewinding with super enamelled copper winding wire of existing gauge and weight, varnishing and drying complete. Reassembling, bringing back to the installation, making the same functional after refixing at the existing location, testing the motor on full load complete all as specified and directed by Engineer-in-Charge.
Disconnecting electric connections, taking up squirrel cage induction electric motor 415/440 V, 50 Hz, 2 pole pairs per phase, 1475 RPM, of capacity 10 HP electric motor (for ponds) from the existing foundation. Transportation to workshop for repair & rewinding with super enamelled copper winding wire of existing gauge and weight, varnishing and drying complete. Reassembling, bringing back to the installation, making the same functional after refixing at the existing location, testing the motor on full load complete all as specified and directed by Engineer-in-Charge.
Disconnecting electric connections, taking up squirrel cage induction electric motor 415/440 V, 50 Hz, 2 pole pairs per phase, 1475 RPM, of capacity 5 HP electric motor (for ponds) from the existing foundation. Transportation to workshop for repair & rewinding with super enamelled copper winding wire of existing gauge and weight, varnishing and drying complete. Reassembling, bringing back to the installation, making the same functional after refixing at the existing location, testing the motor on full load complete all as specified and directed by Engineer-in-Charge.
Disconnecting electric connections, taking up squirrel cage induction electric motor 415/440 V, 50 Hz, 2 pole pairs per phase, 1475 RPM, of capacity 50 HP (booster pump) from the existing foundation. Transportation to workshop for repair & rewinding with super enamelled copper winding wire of existing gauge and weight, varnishing and drying complete. Reassembling, bringing back to the installation, making the same functional after refixing at the existing location, testing the motor on full load complete all as specified and directed by Engineer-in-Charge.
Disconnecting mechanical and electrical connection and taking down Filter feed monoblock pumps (coupled with 3 phase 9.3 KW/ 12.5 HP motor 2900 Rpm) flow - 91 cum/hr, 28m head, type - KDS1331+, S&D 100x100 mm from the existing foundation. Repair the unserviceable pump by insertion of graphite packing, rubber gasket and stud etc/ and replacement of unserviceable spares. Reassembling and fixing to its original position, making mechanical and electrical connections and testing pumping set complete all as specified and directed by Engineer-in-Charge. Note for repair of Plant and Machinery : (a) The cost of "To and from" transportation of pump, motor and other plant etc from installation to workshop for repair shall deemed to be included in quoted rate. (b) Cost of grease shall deemed to be included in quoted rate. (c) Spares will be measured and paid for separately under respective items of BOQ as supply only .
Supply only bronze shaft sleeve DE/NDE suitable for pumps Model No. KDS1331+, S&D 100x100 mm all as specified and directed by Engineer-in-Charge.
Supply only cast iron impeller suitable for pumps Model No. KDS1331+) S&D 100x100 mm all as specified and directed by Engineer-in-Charge.
Supply only ball bearing DE/NDE suitable for pumps Model NO. - KDS 1331+), , S&D 100x100 mm all as specified and directed by Engineer-in-Charge.
Disconnecting and taking up horizontal centrifugal pumps (coupled with 50 HP motor) capacity 60 LPS, 40 m head Model No. SHM 150/32 S&D 150 x150 mm from the existing foundation for Repair the unserviceable pump by insertion of graphite packing, rubber gasket lubricating the moving parts and studs and replacement of unserviceable spares. Reassembling and fixing to its original position. making mechanical connections and testing pumping set complete all as specified and directed by Engineer-in-Charge. Make of pump : Kirloskar Note for repair of Plant and Machinery : (a) The cost of "To and from" transportation of pump, motor and other plant etc from installation to workshop for repair shall deemed to be included in quoted rate. (b) Cost of grease shall deemed to be included in quoted rate. (c) Spares will be measured and paid for separately under respective items of BOQ as supply only .
Disconnecting the centrifugal pump and repairing the same by replacing unserviceable spare parts including lath work etc and re-assembling the same in original position of 5HP to 10HP pump having discharge 5 to 15LPS at 9 to15 Mtr head complete all as specified and as directed by Engr-in-Charge.Note:- Spare parts will be measured and paid separately under respective item of BOQ.
Supply only CI impeller suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only CI casing wearing ring suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only Inter staging CI suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only CI Split glands suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only Ball Bearing suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only Eye bolt suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only Lifting hook steel suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only Key for impeller steel suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only Impeller nut (steel) suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge
Supply only Remetalling, welding & turning of pump shaft suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only Stufing box bush suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only Interstag bush + A195 (Bronze) suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only Vent valve with thumb screw suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only Pump shaft steel (SS 410) suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only SS stud 16 x 65 with nut suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only Gland packing suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only Casing bearing housing suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only C-20 Packing kit suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only Bearing nut suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
Supply only Stud 19 x 65mm suitable for 5 to 10HP monoblock pump set all as specified and directed by Engineer-in-Charge.
M&L for cleaning of coarse bar screen of size 1.0m x 1.0m - 02 Nos, Fine bar screen for size 1.0m x 0.6m - 02 Nos, scraper, inlet and outlet bars screen of both MBBR tanks, clari tube settle duct etc daily complete all specified and directed by Engineer-in-Charge.
S&F in replacement stainless steel bar screen as per site requirement with clear opening of not more than 40mm or 20mm (as per sample) complete all as specified & directed by Engineer-in-Charge.
M&L for replacement of unserviceable Air break power contactors 3 pole, 32 Amp, coil 415 V, 50 Hz and testing after fixing Cat Part No. 3TF3400-0AR0 complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of unserviceable Air break power contactors 3 pole, 12 Amp, coil 415 V, 50 Hz and testing after fixing Cat Part No. 3TF31 10-0A complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of unserviceable thermal overload relays, relay range 5-13.5 Amp and testing after fixing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of unserviceable thermal overload relays, relay range 17.4-25.0 Amp and testing after fixing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of unserviceable auxiliary contact block 1 NC range 1 to 4 Amp make Siemens complete all as specified and directed by Engineer-in-charge.
S&F in replacement of unserviceable auxiliary contact block 1 NO range 1 to 4 Amp make Siemens complete all as specified and directed by Engineer-in-charge.
S&F in replacement of unserviceable Electronic timer star delta (time 3 sec - 60 sec) 240 V AC, 50 Hz and testing after fixing Cat Part No. 3RP15 76-1NP30-8K of make Siemens/L&T/BCH/Legrand complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of unserviceable MCB Triple pole 25A 'C' curve over load & short circuit protection breaking capacity 10 KA complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of unserviceable MCB Triple pole 40A 'C' curve over load & short circuit protection breaking capacity 10 KA complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of unserviceable MCB Triple pole 63A 'C' curve over load & short circuit protection breaking capacity 10 KA complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Power Contactors with aux contact suitable for 3 phase 415 V, 50 Hz, 50 HP/37 KW motor load, and coil voltage 415 V, Cat Part No. MC10EN22 of make - BCH or equivalent in Legrand/L&T/Siemens complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing in replacement underground cable 35 Sqmm, 3.5 core XLPE insulated armoured heavy duly electric cable with aluminium conductor 1100 volt grade complete laid along walls/floors/pipes/in trenches complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing in replacement underground cable 25 Sqmm, 3.5 core XLPE insulated armoured heavy duly electric cable with aluminium conductor 1100 volt grade complete laid along walls/floors/pipes/in trenches complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing in replacement submersible cable round type 08 Sqmm 7 Core, voltage grade upto 1100 volts as per IS 694 suitable for submersible pumpsets capacity 12.5 HP to 20 HP complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing in replacement submersible cable size 6 sqmmX03core 1100 V grade confirming to IS 694 PVC insulated and PVC sheathed industrial flat/round cable complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement CI sluice valve class PN -1.6 ISI marked complete suitable for 200 mm bore of pipe with flanged ends and drilled brass spindle CI gate with brass ring and cast iron cap etc complete all as specified duly fixed at site with rubber flanges, nuts / bolts and washers including repair to disturbed surfaces and testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F in replacement CI sluice valve class PN -1.6 ISI marked complete suitable for 150 mm bore of pipe with flanged ends and drilled brass spindle CI gate with brass ring and cast iron cap etc complete all as specified duly fixed at site with rubber flanges, nuts / bolts and washers including repair to disturbed surfaces and testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F in replacement CI sluice valve class PN -1.6 ISI marked complete suitable for 100 mm bore of pipe with flanged ends and drilled brass spindle CI gate with brass ring and cast iron cap etc complete all as specified duly fixed at site with rubber flanges, nuts / bolts and washers including repair to disturbed surfaces and testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F in replacement, cast iron sluice valve PN-1.6 confirming to IS 14846/2000 suitable for 80mm bore of pipe with flanged ends and stainless steel spindle and iron wheel, including jointing material, necessary gasket nuts, bolts and washers etc. complete all as specified and directed by Engineer-in-Charge
S&F in replacement gun metal globe/ gate valve of size 15 mm bore with iron wheel head, screwed both ends ISI marked complete all as specified and directed by Engineer-in-Charge
S&F in replacement gun metal globe/ gate valve of size 25 mm bore with iron wheel head, screwed both ends ISI marked complete all as specified and directed by Engineer-in-Charge
S&F in replacement gun metal globe/ gate valve of size 20 mm bore with iron wheel head, screwed both ends ISI marked complete all as specified and directed by Engineer-in-Charge
S&F, in replacement, MCCB 4 pole, 415V, with electronic release 100 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement, MCCB 3 pole, 415V, with electronic release 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement, MCCB 3 pole, 415V, with electronic release 250 Amps complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement, Oil immersed Fully automatic star-delta starter with bi-metallic relay suitable for 400V,3 Phase AC,50 Hz, 15HP Electric Motor including initial fill of starter oil and making elect connection and testing complete all as specified and directed by Engineer-in-Charge. Type-KF-40. .
S&F, in replacement, direct on line citation motor starter 415V coil suitable for 2 HP/1.5KW, overload relay range-2.4-3.8 Amp, complete with SS enclosure complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement, direct on line citation motor starter 415V coil suitable for 5 HP-7.5HP, overload relay range-2.4-3.8 Amp, complete with SS enclosure complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement of butter fly valve of size 75 mm complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement of butter fly valve of size 100 mm complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement of butter fly valve of size 150 mm complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement of butter fly valve of size 200 mm complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement of butter fly valve of size 250 mm complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement, cast iron non valve /reflux valve with rubber seat flanged type without bypass arrangement PN 1.6 rating confirming to IS:5312/2004 of size 75 mm dia complete with gasket, nut, bolts and washers etc as required at site complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement, cast iron non valve /reflux valve with rubber seat flanged type without bypass arrangement PN 1.6 rating confirming to IS:5312/2004 of size 100 mm dia complete with gasket, nut, bolts and washers etc as required at site complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement, cast iron non valve /reflux valve with rubber seat flanged type without bypass arrangement PN 1.6 rating confirming to IS:5312/2004 of size 150 mm dia complete with gasket, nut, bolts and washers etc as required at site complete all as specified and directed by Engineer-in-Charge.
S&F, in replacement, cast iron non return valve /reflux valve with rubber seat flanged type without bypass arrangement PN 1.6 rating confirming to IS:5312/2004 of size 200 mm dia complete with gasket, nut, bolts and washers etc as required at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement cast iron pipe of size 150 mm dia including taking out existing with all joinery items and fittings, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MS pipe heavy duty of size 200 mm dia including taking out existing, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MS pipe heavy duty of size 250 mm dia including taking out existing, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement flanged welded Galvanised steel water tubing medium grade 150 mm dia ISI marked immersed Sewage sump 11m deep with all fittings such as tees, elbows, sockets, bends, unions short pieces and diminishing pieces etc laid in sewage sump 11 mtr below ground level, complete all as specified and directed by Engineer-in-charge. Make : Tata/Jindal/Prakash Surya
Taking up or down GI tubing and connections of size 40 mm bore complete all as specified and directed by Engineer-in-Charge.
Taking up or down GI tubing and connections of size 25 mm bore complete all as specified and directed by Engineer-in-Charge.
Taking up or down GI tubing and connections of size 20 mm bore complete all as specified and directed by Engineer-in-Charge.
M&L for GI water tubing medium grade of size 40 mm bore with all fittings laid in trenches complete all as specified and directed by Engineer-in-Charge
M&L for GI water tubing medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floor complete all as specified and directed by Engineer-in-Charge
M&L for GI water tubing medium grade of size 20 mm bore with all fittings laid in trenches or fixed to wall or floor complete all as specified and directed by Engineer-in-Charge
M&L for UPVC pipe 50 mm bore with all fittings laid in trenches complete all as specified and directed by Engineer-in-Charge
M&L for UPVC pipe 40 mm bore with all fittings laid in trenches complete all as specified and directed by Engineer-in-Charge
M&L for UPVC pipe 25 mm bore with all fittings laid in trenches complete all as specified and directed by Engineer-in-Charge
Supply only PVC flexible pipe of size 50 mm dia as specified by Engineer-in-Charge.
Supply only PVC flexible pipe of size 75-80 mm dia as specified by Engineer-in-Charge.
S&F, in replacement, stud of required size as specified and directed by Engineer-in-charge.
S&F, in replacement, gland packing rope size 10 mm complete as specified and directed by Engineer-in-charge.
S&F, in replacement, gland packing rope size 11 mm complete as specified and directed by Engineer-in-charge.
S&F, in replacement, gland packing rope size 12 mm complete as specified and directed by Engineer-in-charge.
S&F, in replacement, nut & bolt of required size complete as specified and directed by Engineer-in-charge.
S&F, in replacement, MS work of required size with all additional joinery items and colour on all complete as specified and directed by Engineer-in-charge.
S&F, in replacement, copper thimble size 25 sqmm complete as specified and directed by Engineer-in-charge.Make- Action/Dowells
S&F, in replacement, copper thimble size 35 sqmm complete as specified and directed by Engineer-in-charge.Make- Action/Dowells
S&F, in replacement, LED security light 40 watt make syska/phillips all complete as specified and directed by Engineer-in-charge.
S&F, in replacement, tyre coupling (TC series) of required size make-Unique/Power/Supreme complete all as specified and directed by Engineer-in-charge
M&L for excavation and making proper space to recifty the leakage of cast iron pipe of size 300 mm to 400 mm bore spigot and socked end including all required material to rectifty the leakage complete all as specified and directed by Engineer-in-Charge.
M&L for excavation and making proper space to recifty the leakage of cast iron pipe of size 150 mm to 200 mm bore spigot and socked end including all required material to rectifty the leakage complete all as specified and directed by Engineer-in-Charge.
M&L for excavation and making proper space to recifty the leakage of cast iron pipe of size 80 mm to 100 mm bore spigot and socked end including all required material to rectifty the leakage complete all as specified and directed by Engineer-in-Charge.
M&L for excavation and making proper space to recifty the leakage of galvanize iron pipe of size 80 mm to 100 mm bore spigot and socked end including all required material to rectifty the leakage complete all as specified and directed by Engineer-in-Charge.
Disconnecting, dismantling and taking aside the pump set of 50 HP capacity and replacement of new frame/MS channel of required capacity and dismantling of existing PCC/RCC foundation and refixing the same pump set by preparing sufficient PCC foundation and base frame required for 50 HP pump set including connecting items like nuts, bolts and setting the alignment of pump set testing and commissioning all as specified and directed by Engineer-in-charge.
S&F in replacement PVC foot valve size 50 mm bore including all material as per IS 4038 complete all as specified and directed by Engineer-in-charge
S&F in replacement PVC foot valve size 75 mm bore including all material as per IS 4038 complete all as specified and directed by Engineer-in-charge
S&F in replacement PVC foot valve size 100 mm bore including all material as per IS 4038 complete all as specified and directed by Engineer-in-charge
Removing of all sludge by connecting pump set and manually, cleaning of well of pump house, removal of sludge to minimum distance of 50 m from starting point with complete all as specified and directed by Engineer-in-Charge.
Taking out outlived MBBR media from MBBR tank of size 11 mtr diax 4 mtr deep by mannual or mechanical and cleaning of media by clear water and removing dirt/silt inside the media, after cleaning of media refilling MBBR media complete all as directed by Engineer -in - Charge .
M&L for preparation of old painted surfaces of any description or girth and applying painting with synthetic enamel paint of desired colour on all MS pipe, Door or gates and complete machinery and items of any size or metal including their names and writing SM/MES number in desired format and colour complete all as specified and directed by Engineer-in-Charge.
S&F in replacement wafer type non return valve of size 80 mm suitable for sewage water complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement wafer type non return valve of size 100 mm suitable for sewage water complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement wafer type non return valve of size 150 mm suitable for sewage water check complete all as specified and as directed by Engineer-in-Charge.
M&L for surface dressing n. exc. 30 cm deep and averaging 15 cm deep in soft/loose soil complete all as specified and directed by Engineer-in-Charge .
S&F in replacement enclosure boxes with IP 65 protection, made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface,approx size 450mm X 400 mm X 300 mm with necessary electrical accessories/connectors required for connecting submersible cables 8 sqmm 7 core to the main supply from starter panels for 4 pumpsets complete all as specified and as directed by ENgineer-in-Charge.
Taking out water sample of STP in containers and getting the water tested from the department of water test examination or any NABL accredited lab as per relevant IS of STP and submission of detailed test report to the office of Engineer-in-charge. Note: (a) The following testing should be done: 1. Colour 2. Turbidity 3. Residual chlorine 4. Total chlorine 5. pH 6. Chloride 7. Flouride 8. Iron 9. Hardness 10. Total plate count 11. Electric conductivity 12. Sulfate 13. Nitrate 14. TSS 15. BOD 16. COD 17. MPN 18. TKN 19. TP (b) Rate quoted shall deemed to be included for- 1. Cost of sertilised bottle as required. 2. Transportation charges
Surface excavation in soft/loose soil n.exc. 45 cm deep including site clearance by removing of grass, vegetation etc. and filling of lower portion with soil obtained from cutting or dressing and removing of debris to a distance n. exc. 50 m complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n.exc. 1.5 m wide & n. exc. 1.5m in depth for foundation etc. n. exc 10 sqm on plan and n. exc. 1.5 m in depth in soft/loose soil and getting out complete all as specified and directed by Engineer - in - Charge
Returning filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cms thick in soft/ loose soil complete all as specified and directed by Engineer - in - Charge.
Removing excavated material (soil) n. exc. 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer - in - Charge.
M & L for dry sand cushioning to UG cable with a layer of sand 8 cm thick before laying of cable and 15cm thick after laying of cable to the full width of trench and punning down to 18 cm thick including well ramming and watering complete all as specified and directed by Engineer - in - Charge. Note :- Thickness after punning down shall be measured for payment.
M & L for brick protection to under ground cable with old size sub class ‘B’ bricks laid flat, length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
M&L Taking out all filter media from dual media filter of approx dia 2.5 mtr, duly cleaning /washing and segregation, refilling backe complete all as specified and directed by Engineer-in-Charge.
M&L Taking out all filter media from dual media filter of approx dia 2.7 mtr, duly cleaning /washing and segregation, refilling back except activated carbon granules complete all as specified and directed by Engineer-in-Charge.
Supply and filling in replacement in layers activated carbon media in suitable size as per existing layer thickness suitable for Activated Carbon Filtre/ Dual media filtre (approx dia 2.7 meter and height 2.9 meter) complete all as specified and directed by Engineer-in-charge.
S&F FRP roofing sheets including all joinery items complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, rotor shaft of solid handing sewage transfer submersible pump Model : NS 80/26Q, Head 15m, flow - 102 cum/hr, Capacity 9.3 KW/ 12.5 HP as specified and directed by Engineer-in-Charge.
S&F in replacement, rotor shaft of solid handing sewage transfer submersible pump Model : Model : NS 50/26N Head 9m, flow - 54 cum/hr Capacity 3.7 KW/ 5 HP as specified and directed by Engineer-in-Charge.
S&F in replacement bearing bracket suitable for solid handing sewage transfer submersible pump Model : NS 80/26Q, Head 15m, flow - 102 cum/hr, Capacity 9.3 KW/ 12.5 HP as specified and directed by Engineer-in-Charge.
S&F in replacement bearing bracket suitable for solid handing sewage transfer submersible pump Model : NS 50/26N Head 9m, flow - 54 cum/hr Capacity 3.7 KW/ 5 HP as specified and directed by Engineer-in-Charge.
S&F in replacement mechanical seal bracket suitable for solid handing sewage transfer submersible pump Model : NS 80/26Q, Head 15m, flow - 102 cum/hr, Capacity 9.3 KW/ 12.5 HP as specified and directed by Engineer-in-Charge.
S&F in replacement mechanical seal bracket suitable for solid handing sewage transfer submersible pump Model NS 50/26N Head 9m, flow - 54 cum/hr Capacity 3.7 KW/ 5 HP as specified and directed by Engineer-in-Charge.
S&F in replacement digitally printed flex banners both sides printed of required colour and size with all accessories and parts including their supported GI boards all complete as specified and directed by Engineer-in-charge.
M&L PCC 1:3:6 (40mm graded stone aggregate) type C2 in foundation of posts and struts complete as specified and directed by Engineer-in-charge.
Notes : (1) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline. (2) Make of parts to be replaced shall be compatible with existing make as recomended by OEM and approved by the Engineer-in-Charge and Rates are inclusives of this factor. (3) Any minor item which is not specifically mentioned in description but required for its satisfactory fuctioning of equipments are deemed to be inclusive in unit rate. No extra claim shall be admissible on this account (4) All types of repair and replacement should be done and with complete fitting/placing at directed place within 48 hours of intimation otherwise panelty of Rs 1000.00 per day will be charged after that. (5) For item no. 23 to 31: (i) Cleaning shall be carried out by the following methods: (a) Cleaning inner surface of tank by scraping with steel wire brush and removing mud & sludge collected inside the tanks manually at a distance not exceeding 50 Mtrs. (b) Washing with clean water & bleaching powder mixture thouropuly complete tank internally and removal of left out sludge, if any, at site to distance not exceeding 50 Mtrs. (b) Rate quoted shall include the aspects:- (a) Diesel Driven Pump Set/elctric pump set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De-Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes . All instruments/pump set/motor will be arranged by contractor. (c) Tractor mounted storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location as directed by Engr-in-charge. (d) Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same as directed by the Engr-in-charge. (e) Appropriate qty of Phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank as directed. (f) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc. required at site as directed.
DASHMESH ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .