Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance FIRST DAR COMPLEX MALA BAGH NEAR JK BANK SRINAGAR SRINAGAR JAMMU AND KASHMIR 190006 | SRINAGAR | JAMMU AND KASHMIR | 190006 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹33.2 L
Closing Date
26 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Electrification of 02 Storeyed Building for Health Centre at North Campus.
2021_UDJK_130792_1
F(E.Tend)( UCD)KU/22/21
Open Tender
Electrical Works
Item Rate
180 days
Health Centre North Campus
As per NIT
5 documents required · 5 mandatory
₹1,100
Registrar University of Kashmir
Exempted
27 Jul 2021
14 Jul 2021
27 Jul 2021
15 Jul 2021
26 Jul 2021
15 Jul 2021
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Finolex, Havells, Polycab, Plaza make) in surface / recessed PVC conduit (D Plast, PGC, Flair, PolyCab, AKG, Anchor), with modular switch, modular socket, modular plate (ABB, Legrand, Havells, SSK make), suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable PVC conduit included in above description for the follwing items From switch board to primary light point & it's loop. Point upto desired length and upto sub DB
Wiring for computer point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Finolex, Havells, Polycab, Plaza make) in surface / recessed PVC conduit(D Plast, PGC, Flair, Polycab,AKG, Anchor), with 6A modular switch, 2 Nos. 6A modular socket, modular plate (ABB, Legrand, Havells, SSK make), suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable PVC conduit included in above description. Point taken upto sub DB
Wiring for heating point with 4 sq.mm FRLS PVC insulated copper conductor single core cable (Finolex, Havells, Polycab, Plaza make) in surface / recessed PVC conduit(D Plast, PGC, Flair, Polycab,AKG, Anchor), with 16A modular switch, 1 Nos. 16A modular socket, modular plate (ABB, Legrand, Havells, SSK make), suitable GI box and earthing the point with 4 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable PVC conduit included in above description. Point taken upto sub DB
Wiring for Industrial type socket outlet point with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor single core cable(Finolex, Havells, Polycab, Plaza make) in surface / recessed PVC conduit (D Plast, PGC, Flair, Polycab,AKG, Anchor), with 30 A, 415 V, TPN Industrial type socket outlet (Legrand, ABB, Hager, Havells, SSK make) (Conduit shall be heavy duty), metal enclosed plug top alongwith 30 A "C" curve, TPN MCB, in sheet steel enclosure, on surface or in recess Note : Rates of Suitable PVC conduit included in above description. Point taken upto DB duly tested and commissioned (Required for three phase supply to three phase loads in X ray room in GF and Testing Room in First Floor@2 Supply points in each room.)
LT Cable
NON D.S.R ITEMS Supply and fixing of ISI marked aluminum conductor XLPE insulated cable(Finolex, Havells, Polycab,CCI, Paramount make) as per IS 7098, armoured, served, sheathed 1100 volts grade. 4x 35 sq. mm
4x 16 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (22mm)
4 X 35 sq. mm (32mm)
Sub Distribution Box/MCB Box Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Legrand, Hager, ABB, Eaton,Siemens make)
16 way, Double door
12 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required (Legrand, Hager, ABB, Eaton,Siemens make)
8 way (4 + 24), Double door
Providing and fixing of 125A, 36kA 4P MCCB (Legrand, Hager, ABB,Eaton, Siemens make)
Supplying and fixing of 6 Amp to 32 Amp. S/P MCB, C-Curve etc. as required in existing MCB DB complete with connections, testing and commissioning etc. as required (Legrand, Hager, ABB,Eaton, Siemens make)
Supplying and fixing 15 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral(TPN) required for three phase supply to three phase loads in X ray room in GF and Testing Room in First Floor@2 Supply points in each room. (Legrand, Hager, ABB,Eaton, Siemens make)
Supplying and fixing 40-63 A rating, 240V 10 kA, “C” curve, Double pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Legrand, Hager, ABB,Eaton, Siemens make)
Supplying and fixing of following size TPN MCB, C-Curve etc. as required in existing MCB DB complete with connections, testing and commissioning etc. as required 40 A TPN ( to be installed in separate DB for exclusive Three Phase Supply in Xray room in GF and procedure Room in FF). (Legrand, Hager, ABB,Eaton, Siemens make)
Main Service LT Panel
Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,space heater, power outlet, illumination lamp, Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enameled painted and having following incoming and outgoing MCCB & Auto Transfer Switch complete as required. Incomer : 1 no. 320A 4P microprocessor based MCCB of 25kA with Rotary Handle, shunt trip coil, adjustable O/L, S/C, E/F release. 1 no. 125A 4P Manual Transfer Switch of 25kA. 2 nos. Digital type multifunction meter with following parameters Digital multifunctional meter having RS 485 port for BMS Integration with 1 set of CT's of 60/5 Amp & 1 set of CT's of 200/5 Amp. 1 set of CT's of 250/5 Amp for APFCR relay in main breaker of Main LT Panel. 2 Set of R,Y,B LED phase indicating lamp with MCB protection. 2 Set of ON,OFF & TRIP LED indicating lamp with MCB protection. BUSBARS: 400 Amp & 100 Amp TPN (25kA for 1sec) aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminium shall not be more than 0.8 Amps/ sq.mm. OUTGOING: 5 nos. 160A 4P thermal magnetic based MCCB of 25kA with Rotary Handle, shunt trip coil, adjustable O/L, S/C, E/F release. Digital Multifunction Meter having RS 485 port for BMS Integration, with suitable rating Class-I CT's for outgoing feeders as marked in SLD . 1 Set of Amp meter, Volt Meter & Frequency Meter with 1 set of CT's of 60/5 Amp for outgoing feeder as marked in SLD. For all out goings ON/OFF LED indicating lamp with MCB protection.
Main LT Power Cable
Supplying in underground/clamped to wall with suitable clamps saddles and fixing bolts/ in ground including testing and commissioning of the following sizes of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable conforming to IS : 7098 (Part-I). Identification tags shall be provided for all cables and route markers for cables in ground as per specifications and as per instructions of Engineer- in-charge.4 core X 150 mm2 Armoured XLPE Aluminum cable (Finolex, Havells, Polycab,CCI, Paramount make)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refilling the trench etc as required-Above 150 sq. mm and upto 300 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-4 X 150 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
120 mm dia (OD-120 mm & ID-103 mm nominal)
Light Fixtures and Fans
Supply and fixing of 4 feet ,20Watt LED Batten, 6500K along with accsessory assembly or equivelent slim of Philips/Crompton/Osram/Bajaj) complete in all respects.
Providing and Fixing of 7 Watts LED Panel, round/square type, color temp: 6500K/4000K, Surface/Recessed mounted as per site requirement of Wipro or Philips or Havells or eq.
Providing/fixing of 2 ft long LED batten, 12Watts, 230V complete with tube, base etc. Make: Syska/Philips/Wipro/Havells
Supplying, erection and testing of approved make electric ceiling fan of complete with standard down rod, canopy, hanging shackle, Aluminium blades, A.C. 230-250 volts including connections with all necessary material complete of approved as required -Ceiling Fan ( ISI )-1200 mm Sweep,80-90W.
Supplying and fixing of wall fan complete with all accessories of Make: Havells/ C&G/ Halonix
SITC of approved make Exhaust Fan of 200 mm (8 Inches), plastic body with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished of approved as required of make Havells/ C&G/ Halonix
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but including modular plate etc. as required complete in all respects.(for ceiling fans points) of make ABB, Legrand, Havells, SSK
Providing and fixing of lighting fixtures pressure die-cast alluminium IP65 flood light luminery with high power LED 50 Watts with toughned glass of make Philips, Wipro, Havells etc complete
Supplying and fixing 6 A ceiling rose (GM, Havells make) i/c junction box including connections etc. as required.
Earthing System
Providing earthing stations at locations as called for Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as require i/c Constructing masonry Chamber 100x100x100 cm, inside with 75 class designation brick work in cement moryar 1:5 ( 1 cement : 5 fine sand ) for valve, with C.I.surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12mm thick finished with a floating coat of neat cement complete as per standard design (NOTE: Actual Depth of chamber may vary as per Site conditions).
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Lightning Conductor
Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc complete as required
Jointing G.I. tape (with another G I tape, base of the finial or any other metallic object) by riveting / nut bolting sweating and soldering etc. as required
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet oron surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For vertical run)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
INTELLIGENT FIRE ALARM SYSTEM
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required of make Finolex, Havells, Polycab or eq.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.with 25 mm dia and 2mm thick of make PolyCab, AKG, Anchor
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable smoke detector with built in LED, mounting base complete with all connection etc. Notifier/ Honeywell/ Siemens / Bosch)
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
STRUCTURAL CABLING & CONDUTTING FOR DATA SYSTEM
Supply, Installation testing and commissioning of wall mounting rack for computer switches complete as mentioned below 6U cabinet 371.30X600X500, wall mounting with power supply and Fan etc :-switch.Make: Val Rack/ Net Rack/ APW )
Supply, installation, testing and commissioning of wall mounted 4U metal rack for housing 8 port ethernet switch etc complete with Tray Mounting Fan + power supply board. Bank's hardware - port switch / patch panel.The cabinet frame shal have minimum depth of 500mm to accomadate 8 port ethernet switch.Make: Val Rack/ Net Rack/ APW )
Supply, installation, testing and commissioning of approved make approved brand (DLink/Cisco/Digilink/Amps ) 32 -port Ethernet Gigabit switch complete in all respects
Supply, installation, testing and commissioning Wireless Acess points/Wi-fi points of Netgear/Cisco./Huwai /Dlink approved make approved brand complete in all respects
Supply, Installation testing and commissioning of patch cord as mentioned below :-CAT 6 RJ45 Patch Cord F/UTP 1 Mtr.
Supply, Installation testing and commissioning of patch cord as mentioned below :-CAT 6 RJ45 Patch Cord F/UTP 2 Mtr.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(1 run of cable)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required with 25 mm dia ,2mm thick (D Plast, PGC, Flair, PolyCab, AKG, Anchor make)
HARMUKH INFRASTRUCTURE PRIVATE LIMITED
HUBBI ELECTRICALS
M/s ESS ESS ENTERPRISES
HIBA ENGINEERING AND CONSTRUCTION WORKS
M/S TARIQ AHMAD ITOO
M/S B.I.ELECTRICALS
bhat and brothers co
Rangrez Electic Works
stage.html
html • 0.03 MB
finance_259122.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .