Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance JABALPUR | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
15 Nov 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Office of Ex En PHE Division Reasi
Office of Ex En PHE Division Reasi
Providing, installation testing and commissioning of electro mechanical components and other allied works under WSS Pangal Devta
2023_PHE_234262_2
E-NIT no PHER/74 of 2023-24
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
120 days
Reasi
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
2 Dec 2023
1 Nov 2023
16 Nov 2023
1 Nov 2023
15 Nov 2023
1 Nov 2023
Amount
Providing, installation Of HC Pump Motor Set:- Providing of multi stage HC Pump of 8000 GPH X 250MTR head coupled with suitable induction motor. Foundation Blocks :-Construction of R.C.C. foundation block of required size as per base frame of pumpset inside the pump room at pump room for installation of pumping units by excavation of soil to finish with required dimensions of the pit, removal of excavated material and disposing off the same outside the pump room at suitable place as per site conditions. The job also includes demolishing the existing flooring of requisite area with jack hammer, high carbon steel chisels and sledge hammer, providing and laying of crushed stones 40 mm and ramming properly. Laying of one layer of 1:3:6 concrete mass 30 mm thick. Fabrication& Providing of steel foundation bolts of required dia 600 mm in length – 6 Nos. having threaded portion at one end and an anchor at the other end. Also providing fabrication of steel hexagonal nuts and washers for the foundation bolts. Fabrication of steel reinforced cuboidal structure of requisite size for the foundation block out of T.M.T steel bars 10 mm thick by way of cutting, the steel bars of required length and placing in position at proper spacing longitudinally and transversally and binding with black annealed wire them properly so that internal cube meshes of 6” size are formed. Job includes fabrication charges as well hirer charges of welding set. Lowering the reinforced/cuboidal steel structure in the pit and then placing the base frame of the pump over the steel reinforced cuboidal steel structure making proper leveling and alignment of the base frame over the cuboidal steel structure. Placing the threaded end of the foundation bolts in upright vertical position at required distance in position and in alignment after lowering through holes of base frame. Binding of the foundation bolts with the steel mesh of cuboidal steel reinforced structure at various spots and then fastening the base frame over the reinforced steel structure by tightening the nuts of the foundation bolts, simultaneously ensuring proper leveling and alignment of the base frame over the reinforced cuboidal steel structure. The job further includes laying of M-20 grade cement concrete block including steel reinforcement, machine mixing laying and compaction with vibrator using stone aggregate 1:11/2:3 mix (1 cement 11/2 coarse sand and 3 graded stone mixture of specified grade of nominal size 20mm) including binding chemical up to top level from inside the base frame and up to the bottom line of base frame from outside of the base frame – also plastering the exposed surface of block. Construction of drain for draining out the occasional leakage water of pump. Also repairing of damaged flooring wherever required with cement concrete mixture using chemical bonding material for smooth finish of the flooring of the pump room, and proper curing of cement works for proper strength for a minimum of 07 days. The whole job also includes cost of material and carriage charges for all material from various sources by Mech. Transport as well as head load, hire charges of shuttering material, vibrator and concrete mixture and welding set, POL for vibrator and concrete mixture, labour charges for laying of foundation block, including skilled and semi-skilled workers deployed for execution of job. Carriage:-Carriage of pumping machinery (pump, motor, coupling set, base frame to site of work by Mech. Transportation and Head Load up to Pump Room. The job also includes dismantling the pumping unit, unfastening the coupling bolts, nuts, bolts of the base frame for separating each component viz. motor pump, coupling set, base frame etc., for their proper handling and carriage. Installation:-Installation of new 8000 GPH X 250M. Head H.C. pump set on the foundation blocks at pump room by way of providing and fitting of bolts with nuts and washers for fitting of new pump and motor on each base frame, Also leveling of pump and motor in proper alignment with each other. Tightening the nut bolts of the base frame. Providing and fitting graphite gland packing with fitting of pump glands. Coupling the pump and motor by way of fixing of coupling bolts. Job includes cost of graphite gland packing, nut bolts of the base frame and labour charges for skilled and semiskilled workers deployed for execution of job.
Providing, installation Of HC Pump Motor Set:- Providing of multi stage HC Pump of 8000 GPH X 200MTR head coupled with suitable induction motor. Foundation Blocks :-Construction of R.C.C. foundation block of required size as per base frame of pumpset inside the pump room at pump room for installation of pumping units by excavation of soil to finish with required dimensions of the pit, removal of excavated material and disposing off the same outside the pump room at suitable place as per site conditions. The job also includes demolishing the existing flooring of requisite area with jack hammer, high carbon steel chisels and sledge hammer, providing and laying of crushed stones 40 mm and ramming properly. Laying of one layer of 1:3:6 concrete mass 30 mm thick. Fabrication& Providing of steel foundation bolts of required dia 600 mm in length – 6 Nos. having threaded portion at one end and an anchor at the other end. Also providing fabrication of steel hexagonal nuts and washers for the foundation bolts. Fabrication of steel reinforced cuboidal structure of requisite size for the foundation block out of T.M.T steel bars 10 mm thick by way of cutting, the steel bars of required length and placing in position at proper spacing longitudinally and transversally and binding with black annealed wire them properly so that internal cube meshes of 6” size are formed. Job includes fabrication charges as well hirer charges of welding set. Lowering the reinforced/cuboidal steel structure in the pit and then placing the base frame of the pump over the steel reinforced cuboidal steel structure making proper leveling and alignment of the base frame over the cuboidal steel structure. Placing the threaded end of the foundation bolts in upright vertical position at required distance in position and in alignment after lowering through holes of base frame. Binding of the foundation bolts with the steel mesh of cuboidal steel reinforced structure at various spots and then fastening the base frame over the reinforced steel structure by tightening the nuts of the foundation bolts, simultaneously ensuring proper leveling and alignment of the base frame over the reinforced cuboidal steel structure. The job further includes laying of M-20 grade cement concrete block including steel reinforcement, machine mixing laying and compaction with vibrator using stone aggregate 1:11/2:3 mix (1 cement 11/2 coarse sand and 3 graded stone mixture of specified grade of nominal size 20mm) including binding chemical up to top level from inside the base frame and up to the bottom line of base frame from outside of the base frame – also plastering the exposed surface of block. Construction of drain for draining out the occasional leakage water of pump. Also repairing of damaged flooring wherever required with cement concrete mixture using chemical bonding material for smooth finish of the flooring of the pump room, and proper curing of cement works for proper strength for a minimum of 07 days. The whole job also includes cost of material and carriage charges for all material from various sources by Mech. Transport as well as head load, hire charges of shuttering material, vibrator and concrete mixture and welding set, POL for vibrator and concrete mixture, labour charges for laying of foundation block, including skilled and semi-skilled workers deployed for execution of job. Carriage:-Carriage of pumping machinery (pump, motor, coupling set, base frame to site of work by Mech. Transportation and Head Load up to Pump Room. The job also includes dismantling the pumping unit, unfastening the coupling bolts, nuts, bolts of the base frame for separating each component viz. motor pump, coupling set, base frame etc., for their proper handling and carriage. Installation:-Installation of new 8000 GPH X 250M. Head H.C. pump set on the foundation blocks at pump room by way of providing and fitting of bolts with nuts and washers for fitting of new pump and motor on each base frame, Also leveling of pump and motor in proper alignment with each other. Tightening the nut bolts of the base frame. Providing and fitting graphite gland packing with fitting of pump glands. Coupling the pump and motor by way of fixing of coupling bolts. Job includes cost of graphite gland packing, nut bolts of the base frame and labour charges for skilled and semiskilled workers deployed for execution of job.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .