| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC 11 CROOKED LANE KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.2 L+₹44,589 (4.56%)Rejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.3 L+₹48,194 (4.93%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹20,683
Closing Date
24 Sept 2024, 3:00 pmClosed
MD,WBMSCL
Swasthya Sathi, GN-29, Sector-V, Salt Lake, Kolkata 700091
Replacement of damaged MS HVAC pipeline with 3 layer fiber therm glassfiber reinforced with polypropylene green pipe at Gr to 1st fl incl SITC of Motorized actuator,thermostat,control transformers for temp control of 21 no FCU,CHAU at Metiabruz SSH
2024_WBMSC_746355_1
WBMSCL/NIT-498/2024 Dated 05/09/2024
Open Tender
Electrical Work/ Equipment
Item Rate
60 days
Metiabruz SSH
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹20,683
WBMSCL
7 Nov 2024
10 Sept 2024
25 Sept 2024
10 Sept 2024
24 Sept 2024
18 Sept 2024
13 Sept 2024
Amount
Supply Installation ,Testing of HVAC Chilled water pipeline made of fiber therm glass fiber reinforced 3(three) layer with polypropylene material green pipe of following sizes,suspended from celling incl. S&F clamp,suspender,bolts & nuts, steel fastener, reducer, flange socket, elbow, tee, by pass bend, reducing tee, union etc. as required,as per direction of Engineer-in Charge. The pipe line should be insulated with suitable size closed cell(pipe type) black nitrile rubber (Class-1) with adhesive on chiller water pipelines including Taping the whole with a 3mm thick Nitrile Adhesive Tape. The pipe line shall show no sings of localized swelling,leakage or weeping & shall not brust during the standard hydrostatic test. The pipeline should be complete fittings and jointing materials as required following socket welding process by heating the OD of the pipe and ID of the fittings including mending goods the damage work at site. The bidder should have to perform leak test of entire newly installed fibre therm pipe without any additional cost. Fibre therm pipe Make:Fusion/KPT/S&FC Fibre therm fittings Make:Fusion/KPT/S&FC Nitrile rubber Make: K-flex, Armacell Adhessive make: Fevicol- Pedilite / Polygrip
20 mm(ID), PN-16 with single layer 19mm nitrile rubber
25 mm(ID), PN-16 with single layer 19mm nitrile rubber
32 mm(ID), PN-10 with single layer 19mm nitrile rubber
40 mm(ID), PN-10with single layer 19mm nitrile rubber
50 mm(ID), PN-10with single layer 19mm nitrile rubber
63 mm(ID), PN-10with single layer 19mm nitrile rubber
90 mm(ID), PN-10 with single layer 19mm nitrile rubber
Supply Installation ,Testing of PPR Ball valve with necessary fittings including Taping the whole with a 3mm thick Nitrile Adhesive Tape following socket welding process by heating the OD of the pipe and ID of the fittings including mending goods the damage work at site.
PPR Ball valve 20 mm (ID)
PPR Ball valve 25 mm (ID)
PPR Ball valve 63 mm (ID)
Supply, Installation, Testing and Commissioning of Motorized Actuator for fan coil units with 1(one) number two way valve(with automatically balanced combination valve type AB-QM for DN 10-32 with strainer, Brass metal), IP-42, forced switch off in stream down position , Supply voltage 24 AC, Speed: 24S/Sec, with 10 meter cable, .Modulating control, Make: Danfoss (AME 110 NL)/ Similar Honeywell/ Similar Schnider
Supply, Installation, Testing and Commissioning of Digital Fain Coil Thermostat - operating voltage:100~240 VAC±10%, 50/60HZ, On/Off, with 3 Fan speed/Auto & white backlight, operating voltage:100-240V AC, Built-in Temperature Sensor, Setpoint range: 5~45 Deg C step 1OC. The thermostat should be fitted in suitable location on wall with suitable size PVC box. Make: Similar Honeywell (part no.: WM428WN/U)/ Similar Schnider/ Similar Danfoss/ Similar Siemens
Supply of 4 Core, 2.5 sqmm, Unsheathed Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade upto 1100 Volts
Laying of 1.1 KV grade, stranded copper conductor, PVC insulated LT control cable as below, on existing Cable Tray and binding with suitable size GI wire.(PWD SOR Pg. No: F-3, Sl. No. 6.i)
Upto 50 sq.mm.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (PWD SOR Pg. No: F-3, Sl. No. 6.i)
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (PWD SOR Pg. No: E-16, Sl. No. 7.b) 25mm size
Supply Installation Testing and Commissioning of control transformer 240/24V AC, 50 Hz, 5VA on wall including suitable size wooden box enclosure, terminal block, PVC gland etc.
Less cost of dismentelling the existing MS insulated pipelines with and fittings from various location of the SSH (where the MS type chilled water pipeline replaced with fiber therm glass fiber reinforced 3(three) layer with polypropylene material green pipe) including buy back option of the said dismental materials and clearing including removing of waste materials from
CARRION AIR COOLING (BID ID -5626509)
MILLENNIUM AIRCON (BID ID -5608215)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .