Tender Value
₹9.0 Cr
EMD Value
₹18.0 L
Closing Date
11 Aug 2026, 12:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER SEC
17 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less ; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference. (Ref:- GM/Engg. letter no. CE/G/Arb & Cont. Mgt./Tender Circular/Pt. I/317 dtd. 11.03.2025)
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Similar nature of work means- Work of Track circuit OR LVCD OR LC Gate Interlocking O R Electro Mech./Rehabilitation O R Panel Work - (Outdoor) OR Panel Work - (Indoor) OR Panel Work -(Outdoor + Indoor) O R RRI Work-(Outdoor ) OR RRI Work-(Indoor ) OR RRI Work-(Outdoor + Indoor) OR EI/ SSI work - (Outdoor) OR EI/ SSI work - (Indoor) OR EI/ SSI work - (Outdoor + Indoor).
Tenderer should submit relevant document regarding completion and execution of any of the work mentioned in para 1.1 above for fulfilling Technical Eligibility Criteria of Similar Nature of Work.
34 conditions · 4 needing a document upload
GST Registration details should be attached
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under GST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/ UTGST/ SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority.
In case the successful tenderer is not liable to be registered under GST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
JPO to prevent the damages of underground utilities :- The contractor shall conform to JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures (Ref:- RB Letter No. 2021/Tele/5(2)/3-Part (1) (3425647) dtd. 12.06.2023 ). The biddder is requested to go through the same (copy attached) before quoting their offer. The stipulations of the JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures are to be strictly followed till the currency of the contract.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference. (Ref:- GM/Engg. letter no. CE/G/Arb & Cont. Mgt./Tender Circular/Pt. I/317 dtd. 11.03.2025)
Submission of Drawing and Design:- Drawing clauses as stipulated in PCSTE/SER's letter no. S&T/S/322/Pt. XI dtd. 11.03.2024 (Copy attached as File Name -----> Drawing Clause NIT) is to be adhered by. Prospective bidders are instructed to go through the same before quoting offer.
Installation and Commissioning : -
Installation/modification of IPS and MSDAC etc. shall be done by OEMs/under supervision of OEMs. However, commissioning of IPS & MSDAC shall be done by the OEM only. OEMs shall issue a certificate of fitness of installation before commissioning. For this, Railway representative and OEM shall ensure the compliance to Pre-commissioning checklist issued by RDSO. Necessary certificate should be produced by OEM/OEM Authorised vendor, whoever installed the supplied equipments, before final bill payment.
Installation/modification of EI shall be done by OEMs/under supervision of OEMs. However, commissioning of EI shall be done by the OEM only. OEMs shall issue a certificate of fitness of installation before commissioning. For this, Railway representative and OEM shall ensure the compliance to Pre- commissioning checklist issued by RDSO. Necessary certificate should be produced by OEM/OEM Authorised vendor, whoever installed the supplied equipments, before final bill payment.
After the award of the contract, the agency must submit MOU with RDSO approved source (OEM or its RDSO approved source) from which the MSDAC is being taken before supply of equipment wherein the following must be stipulated. (i) Supply of the equipment of MSDAC, (ii) Installation, testing and commissioning of MSDAC by the same RDSO approved source, (iii) After sales-support required during the warranty period and beyond the warranty period.
Since, the work of interlocking of LC gate PH-6 (in PKU-HLZ section) includes the alteration/Modification work in KYOSAN make Electronic Interlocking at Raghunathbari station, hence, this alteration work should be carried out by OEM or authorized representative of OEM. If authorized representative will carry out the work full technical support of OEM is desirable at every stage of work. Hence, bidders should submit the tender specific authorisation or MOU from the OEM before execution of contract agreement.
S&T portion of work in connection to Interlocking of LC Gate nos. TD-15, TD-16, TD- 48, TD-54, TD-68, TD-72, TD-92, TD-93 (TMZ-DGHA section) and PH-6 (PKU-HLZ section)of Kharagpur Division
ST-OT-Interlocking_9LC-26~SER
ST-OT-Interlocking_9LC-26
Open
Works - General
12 Months
Paschim Medinipur, West Bengal
₹0
₹18.0 L
11 Aug 2026
13 Jul 2026
28 Jul 2026
111 items across 4 schedules · ₹8,99,93,354.27 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Alteration involving modification in upto 10 routes. | Per Alteration | 1.00 | 18,28,281 | 18,28,281 |
| 2 | Up to 5 line yard. | Station | 9.00 | 38,738 | 3,48,642 |
| 3 | Preparation of Station Working Rules (SWR) in English on the basis of station working rule diagram and gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railway for checking and resubmission of draft in three copies for approval of division after making corrections. Editable Soft copy to be supplied in pen drive. | Set | 9.00 | 13,595 | 1,22,355 |
| 4 | Preparation of Station Working Rules (SWR) in Hindi/Regional Language of that station on the basis of station working rule diagram and gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railway for checking and resubmission of draft in three copies for approval of division after making corrections. Editable Soft copy to be supplied in pen drive. | Set | 11.00 | 13,595 | 1,49,545 |
| 5 | Preparation of Gate Working Rules (GWR) in English on the basis of station working rule diagram and gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railways for checking and resubmission of draft in three copies for approval of division after making corrections. Editable Soft copy to be supplied in pen drive. | Set | 9.00 | 7,308 | 65,772 |
| 6 | Preparation of Gate working rules (GWR) in Hindi/Regional Language of that LC Gate on the basis of gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railways for checking and resubmission of draft in three copies for approval of division after making corrections. Editable Soft copy to be supplied in pen drive. | Set | 11.00 | 7,308 | 80,388 |
| 7 | Depth 1.0 meter, Width 0.3 meter. | Kilometre | 18.00 | 79,869 | 14,37,642 |
| 8 | Depth 0.8 meter, Width 0.3 meter. | Kilometre | 9.00 | 70,930 | 6,38,370 |
| 9 | Excavation of trenches including clearing of roots of trees etc. in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom. Supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 10262- 2019 or latest and IS-456-2000 as per SEM Drawing No. 15- D3 (Sheet-2) on sieved soil of 30 mm over cable and concreting(1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging and carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This also includes supply of collar and all the materials for concreting by the contractor. | Metre | 850.00 | 589 | 5,00,650 |
| 10 | Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 mtr. Track/ Pucca road/Platform crossing/ Level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of DWC pipes (full) with collar(for jointing pipes) Inner diameter/Outer diameter:103mm/120mm to Specification No.14830 (Part-2):2001 as per SEM Drawing No. 15-D4 and drawing of cable through DWC pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Tech. Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables or any latest guidelines. This includes repairing and plastering of Platform/Pucca road after cable laying. | Metre | 540.00 | 691 | 3,73,140 |
| 11 | 2 HDPE pipe | Metre | 4700.00 | 1,572 | 73,88,400 |
| 12 | 4 HDPE pipe | Metre | 7500.00 | 1,964 | 1,47,30,000 |
| 13 | Mechanised Drilling/Micro Tunnelling under important/ busy metal/concrete road/Railway track and laying of GI pipe including supply (make: TATA/Jindal or better) of min. 75mm inner diameter Grade Medium with Spec. No. IS- 1239, Pt-1, 2004 including supply, Boring and pulling cable upto 110mm dia. at a depth of min. 1 meter as per site condition. This also includes reinstatement of the surface to the original state. | Metre | 450.00 | 2,215 | 9,96,750 |
| 14 | Physical tracing and opening/locating of existing working cables by precision digging for diversion of cables in connection with cable clearance for engineering earth work or for utility shifting without interfering the circuits as per the advice of Railway site engineer. | Metre | 1700.00 | 257 | 4,36,900 |
| 15 | Supply, transportation and fixing of Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 80 mm nominal bore Specification No. IS: 1239, Pt-1, 2004 thickness 3.2 mm medium grade, on bridges, culverts, drain or at places as per instruction of the site Engineer including supply and transportation of materials required for fixing the pipe as per SEM Drawing No.15-D7 on culverts and others including drawing of cables inside the pipe with masonry work at bridge entry and exit of the culvert and curing for 72 hours and pipes are to be clamped at max. 2 meter apart with drilling of holes on the pipe at 10 cm apart for S&T Cables. Note:- This also includes dismantling of released GI Pipe/Trough and released material should be returned at concerned store. | Metre | 270.00 | 1,018 | 2,74,860 |
| 16 | Transportation of cables in rolls with or without wooden drums (S&T Cables) from concerned store to the site of works. Note: The unit Drum-KM indicates Drum X length of cable in that drum. It doesn't have any significance over the distance it has to be carried for execution of the work. | Drum-Km | 111.00 | 2,328 | 2,58,408 |
| 17 | Supply & laying of polyolefin cable channel for laying of signalling/telecom cables, channel attachable to each other with male female swallow tail connectors and having suitable detachable cover as per the following technical specification, Width (Internal/External)- 240 mm/340 mm, Height (Internal/External)- 155 mm/230 mm, Length per pieces- 1000mm (approx.), Material- Polyolefin/Polymers/Engineering Plastics, Fire Behaviours- Fire protection class K1 in accordance with DIN-53438 part-2, Breaking Load (Minimum)- >=12KN, at room temperature, over the specified surface area of 250mm x 150mm, Thermal Characteristics- Thermal stability from -10 degree to +70 degree (as per IS 9000-part-2 & part-3 :1977), Electrical Characteristics- Dielectric strength ; 48kv (Min. breakdown voltage) as per IEC-60243-1-2013, Tolerance-( +/- ) 10mm, Complying to- RDSO Reference No. STS/Cable-Laying Practice Vol-IV dated 9.5.2018 or latest. | Metre | 4100.00 | 2,663 | 1,09,18,300 |
| 18 | Laying of S&T Cables (Signal/Quad/Power) in the excavated trench to Drawing No. CON/SK/T/5 or latest. Supply and transportation of 'U' clamps, anchoring of cable at every 10 metres interval with 'U' clamp on trench to Drawing No. CSTE/CON /CABLES/81 or latest. Supply, transportation, and placing of cable demarcating led belt to Drawing No. CON/SK/T/6 or latest punched at an interval of 30 metres and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER or as per latest guidelines and guarding the cables. Collecting empty drums with left over cable and to be returned to the stores of stock holder. Note: Cables will be meggered before & after its laying by contractor under supervision of Railway representative & Contractor will submit their reports. | Kilometre | 111.00 | 20,239 | 22,46,529 |
| 19 | Supply of Steel Apparatus case Full height as per Drawing No. SK/Drg./OL/SER /198 or latest with E type lock . E-type lock & their key ward No. will be decided by site engineer as per Specification No. IRS: S-10/78 with Rev. 8 or latest. Supply of Hylam sheets is not covered under this scope. This includes supply of one key & handle for each four Apparatus Case or minimum one. | Numbers | 90.00 | 17,430 | 15,68,700 |
| 20 | Execution of Full Apparatus Case with earth excavation for pit, concrete foundation, surrounding earth work, erection and installation as per Drawing No. Con/SK/T/8 or latest and wiring to be done as per SEM Drawing No.19-D8 or as per direction of site engineer. Supply and fixing of Hylam sheet strip of appropriate size of 3 mm or 6 mm as required with hole for fixing of terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, proper soldering of cable armour with earth catenary wire, earthing of cable armour as required. Writing & terminal description including Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This also includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement. The contractor shall supply 4 no. of foundation nuts & bolts of size 22 mm dia. x 450 mm long with 2 flat spring washers, with each nut & bolts, sand for filling up cable pit inside the apparatus case including plaster and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%. | Numbers | 90.00 | 9,147 | 8,23,230 |
| 21 | Alteration/modification in existing location boxes, includes fixing/Removal or both the equipment, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagram. This includes filling with sand and plastering the same. Note: All the sundry materials such as paint, sand, cement, screws etc to be supplied by the contractor. | Numbers | 27.00 | 2,734 | 73,818 |
| 22 | Supply of 25 mm thick Hylam Sheet of size 955mm x 400mm per specification no. IS 2036 of 1995 or latest. Note:- In case the requirements are different from the above, proportionate payment will be done. | Numbers | 18.00 | 1,198 | 21,564 |
| 23 | Supply of Fuse Auto Change Over System (FACS) type-I/II along with audio visual indication as per RDSO spec. No. RDSO/SPN/209/2012 Ver.2.0 or latest. It shall work on 24V DC/60V DC/110V AC as specified by the purchasers. The system shall be capable of monitoring fuses with system voltage of fuse circuit as 12V, 24V, 60V or 110V DC/AC Type-I: One module of Fuse Alarm System Should be able to cater for monitoring of 32 nos. of "G" type fuses from 0.6 Amp. to 4 Amp. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Or Type-II: One module of Fuse Alarm System Should be able to cater for monitoring of 24 nos. of "G" type fuses from 4 Amp. to 10 Amp. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. | Numbers | 9.00 | 20,462 | 1,84,158 |
| 24 | Installation, testing & commissioning of Fuse Auto Change Over System type-I / II along with audio visual indication as per RDSO spec. No. RDSO/SPN/209/2012 Ver.1.0 or latest. | Numbers | 9.00 | 1,210 | 10,890 |
| 25 | Supply of 25 mm 6 Way PBT Terminal block as per Specification No. IRS:S- 75/2006 Rev. 2.0 or latest as per IRS Drg. No. SA-23756 Alt-3 or its latest amendments. | Numbers | 1800.00 | 322 | 5,79,600 |
| 26 | Supply of Non-metallic (FRP) Colour Light Signal, for Two aspect Complete without lenses, lamp holder and Signal transformer as per RDSO Drawing No. SA/23003 A/M (Adv.) or latest and as per Specification No. RDSO/ SPN/194/2006 Rev. 2.0 or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post. | Numbers | 36.00 | 21,556 | 7,76,016 |
| 27 | Transportation and installation of 2- Aspect Signal Post for MACLS as per drawing no. Con/SK/T/12 or SEM-Drawing No. 19-D3 or RDSO/M-00011RU dated 12.01.18 or latest complete with signal units, base, ladder and other fittings, excavation of earth pit, casting concrete foundation, erection of posts, thereof as specified in the note given in drawing, fixing of complete fittings of the signals with necessary earth screen protection arrangement as required including termination of cables, painting and lettering as required. Foundation nuts & bolts of appropriate size as per above drawings or latest as per RDSO Drawing No. SA-116 A/M confirming to IS: 226 and IRS:S-10/78 Rev.8. or latest to be supplied. | Numbers | 36.00 | 10,788 | 3,88,368 |
| 28 | Supply of Non-metallic (FRP) Colour Light Signal, for Three aspect complete without lenses, lamp holder and Signal transformer as per RDSO Drawing No. SA/23002A/M (Adv.) or latest and Specification No. RDSO/SPN/194/2006 Rev.2.0 or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post. | Numbers | 18.00 | 23,723 | 4,27,014 |
| 29 | Transportation and installation of 3/4 - Aspect Signal Post for MACLS as per Con/SK/T/12 or SEM-Drawing No. 19-D3 or RDSO/M-00011RU dated 12.01.18 or latest complete with signal units, base, ladder and other fittings, excavation of earth pit, casting concrete foundation, erection of posts, thereof as specified in the note given in drawing, fixing of complete fittings of the signals with necessary screen protection arrangement including termination of cables, painting and lettering as required. Foundation nuts & bolts of size appropriate size as per above drawings or latest as per RDSO Drawing No. SA- 116 A/M confirming to IS: 226 and IRS:S- 10/78 Rev.8. or latest to be supplied. | Numbers | 18.00 | 11,520 | 2,07,360 |
| 30 | Supply of 140 mm diameter Cast Iron (Grade-20) Signal base as per Drawing No. S-2011/M and as per Specification No. IRS:S-10/78 & IS:210 or latest. | Numbers | 54.00 | 6,380 | 3,44,520 |
| 31 | Supply of 5.5 meter Tubular (Seamless) Post for Colour Light Signal Specification No. IRS:S-6/81 or latest to suit 140mmm dia. base. | Numbers | 54.00 | 14,011 | 7,56,594 |
| 32 | Supply of 5.5 meter Ladder for Colour Light Signal as per RDSO Drawing No. SA-23156 (Adv.) or latest and Stage with Ladder foundation as per Drawing No. S- 2033/M (IRS) or latest & as per Specification No. IRS:S-10/78 & IS:210 or latest. | Numbers | 54.00 | 12,259 | 6,61,986 |
| 33 | Supply of metallic Offset bracket for Colour Light Main Signal Unit to fix on post of 140 mm outside diameter as per RDSO Drawing No. SA- 23080 (Adv.) Alt-1 or latest and Specification No. IRS-S- 10/78 or latest. | Numbers | 54.00 | 3,422 | 1,84,788 |
| 34 | Supply of Signal Number plate pressure sensitive Retro reflective type high intensity grade white with imprinted 'Alphanumeric' in Black & White of size as per SEM Drg.19-D10 (Sheet 6 to 7) or latest with film thickness 0.3 mm on ACP sheet with Clamp for Main/Shunt Signal made of MS Flat of size 30mm x 3mm with nut & bolt as per SEM Drg. No. 19- D10(Sheet 9-10) or latest. | Numbers | 54.00 | 244 | 13,176 |
| 35 | Supply of Signal Marker Retro reflective type high intensity grade white/yellow with imprinted 'A'/'G'/'C'/'AG/'IB'/'P' in black of size as per SEM Drg.19- D10(Sheet 1 to 5) or latest with film thickness 0.3mm on ACP sheet with Clamp for Main/Shunt Signal made of MS Flat of size 30mm x 3mm with nut & bolt as per SEM Drg. No. 19-D10(Sheet 9-10) or latest. | Numbers | 36.00 | 194 | 6,984 |
| 36 | Fixing of 'P'/'G'/'C'/'A'/'AG'/'IB'/Marker/Arrow marker/ Signal Number plates with complete fittings as per site requirement. | Numbers | 90.00 | 196 | 17,640 |
| 37 | Supply of Composite/Q series Relay Rack as per Drawing No. SK/DRG/OL/SER/192, Sheet 1 and 2 or latest and must be powder coated of stone grey colour. | Numbers | 10.00 | 20,469 | 2,04,690 |
| 38 | Transportation, Grouting/Erection, wiring as per approved wiring diagram on 19" Relay rack/Composite/Q-Series Relay Rack with subsequent alteration. This includes supply of 3/4 X 9" anchor nuts & bolts, washer, D-bracket & 60mm insulator, supply & fixing of M.S. ladder as per requirement for rack to rack connection, on CTR and control panel, fixing of plug boards, relays, terminal blocks, terminals, filter units, tag blocks, fuses, bus bars, shelves, strips, 6mm Hylam sheet of required length for writing terminal description etc., fixing and termination of cables on the relay racks with number embossed ferrules, bunching of cables with PVC tape, earthing of cable armour including painting and lettering. Wiring and testing of complete relay rack accommodating all relays as per wiring diagram. Cement, stone chips & sand as required for mounting to be provided by contractor. All materials such as eyelets, Hylam sheets, ferrules, trough etc., if required for modification of rack shall be supplied by the contractor and to be carried out at site with no extra cost to the Railway. | Numbers | 10.00 | 47,638 | 4,76,380 |
| 39 | Supply of MS Cable termination Racks (CTR) as per Drawing No. SK/DRG/OL/SER/197 or latest and must be powder coated of stone grey colour. | Numbers | 9.00 | 15,000 | 1,35,000 |
| 40 | Transportation, grouting/erection, fixing and installation of Cable Termination rack (CTR), fixing of MS Wiring ladder from relay rack to CTR, and on to top of the CTR- including supply of 3/6mm Hylam sheet of required size for fixing terminal blocks & writing terminal description, termination of cables, bunching of cables by PVC tape and earthing of cable armours, painting, lettering as required. The contractor shall draft terminal analysis chart on the white bond paper of appropriate size & supply wiring materials like eyelets of sizes, trough, condensers and resistances as per required capacity, HV protection cover with fixing top caps and danger symbol, soldering material of approved quality etc. shall be supplied by the contractor. Cement, stone chips and sand as required for mounting CTR, Sand for filling of cable pit and other required masonry work, Sundry materials such as MS plate/angles, MS wiring ladders as per approved Drawing, , Anchor bolt 5/8" X 9" with nut and washers -4 No., Nickel plated screws 2BA X1" with nuts and washers for fixing Hylam sheet, numbers embossed ferrules 2.5 sq. mm, PVC bunching tapes and buttons, paint synthetic enamel of smoke grey colour for painting, MS clamps with bolts and nuts of sizes, D-bracket and 60mm insulator, for fixing cables, screws of sizes as required shall be supplied by the contractor. Cables should be routed properly through ladder. | Numbers | 9.00 | 51,944 | 4,67,496 |
| 41 | Alterations/modifications works on existing relay rack (Q-series/ Composite Relay Racks)/Cable Termination Racks (CTR) including works of installation, wiring, termination, testing and commissioning. The work includes fixing of aluminium/steel/M. S ladder along with supply as per requirement to accommodate additional plug board, relays, terminals/blocks, terminals, tag blocks, fuses, transformers, bus bars, TW shelves/strips etc. in the existing relay racks/CTR's, 6 mm Hylam sheets of required length for writing terminal description etc. fixing and termination of cables on the relay racks, CTR's with number embossed ferrules, bunching of cables with PVC tapes, earthing of cable armours, covers including painting and lettering, making anti tilting arrangement. Note:- a) Relay rack (Q- series/ Composite Relay Racks) : Payments for alterations in existing relays upto 20 nos. relays & above 20 nos. shall be made 50% & 100% respectively. b) Cable Termination Racks (CTR):- Payments for alterations in existing CTR upto 120 cores & above 120 nos. cores shall be made 50% & 100% respectively. | Numbers | 18.00 | 21,225 | 3,82,050 |
| 42 | Supply of Negative Bus Bar of size 20 mm X 5 mm made of copper bar with brass screw & washer minimum length of one piece is to be 0.3 m. The bar and screw should be nickel plated. | Metre | 45.00 | 975 | 43,875 |
| 43 | Supply of Remote terminal unit (RTU) with 128 Digital & 16 Analog inputs with E1/64 Kbps Voice Channel/Optical modem as per Specification No. IRS:S- 99/2006 (Amdt-3) or latest. Magnetic door lock coil to be supplied along with equipment. Note: i) The contractor is required to confirm the required modem to meet the site requirement before placing an order to any RDSO approved OEM from Engineer in charge. ii) The inspection of E1/Optical Modem shall be done by consignee. | Set | 9.00 | 1,85,746 | 16,71,714 |
| 44 | Installation, Wiring, Testing, Validation and commissioning of Remote terminal unit with 128 Digital & 16 Analog inputs with modem as per Specification No. IRS:S-99/2006 (Amdt-3) or latest. | Set | 9.00 | 18,574 | 1,67,166 |
| 45 | Supply of External Modem (leased line modem) as per Specification No. IRS:S- 99/2006 (Amdt-3) or latest. | Numbers | 9.00 | 25,370 | 2,28,330 |
| 46 | Supply of PVC Insulated Single core Multistrand, unsheathed with plain annealed/tinned copper conductor 16/0.2 mm diameter as per Specification No. IRS:S-76/89 or latest. Wire Colours shall be decided by engineer-in-Charge. Note: The requirement of plain/tinned copper to be decided by the Engineer in charge. | Kilometre | 42.00 | 7,832 | 3,28,944 |
| 47 | Supply of PVC Insulated single core cable multistrand, unsheathed with plain annealed/tinned copper conductor 7/0.75 mm diameter as per Specification No. IRS:S-76/89 or latest. Wire Colours shall be decided by engineer-in-Charge. Note: The requirement of plain/tinned copper to be decided by the Engineer in charge. | Kilometre | 4.50 | 43,745 | 1,96,852.5 |
| 48 | Supply of PVC insulated 10 Sq. mm Single core Multi strands copper conductor as per Specification No. IRS:S- 76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in-Charge. | Metre | 1650.00 | 109 | 1,79,850 |
| 49 | Supply of PVC insulated 16 Sq. mm Single core Multi-strands copper conductor as per Specification No. IRS:S- 76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in-Charge. | Metre | 1650.00 | 149 | 2,45,850 |
| 50 | Supply of PVC insulated 35 Sq. mm Single core Multi-strands copper conductor as per Specification No. IRS:S- 76/89 or latest conforming to IS: 694/2010 or latest. Wire Colours shall be decided by engineer-in-Charge. | Metre | 850.00 | 254 | 2,15,900 |
| 51 | Supply of Electric key transmitter (EKT)/Rotary key transmitter (RKT) as per Specification No. IRS:S-21/2001 Rev 1.0 or latest & Drawing No.SA-22601 or latest with the keys and wards nos. will be per instructions given by site Engineer in charge. | Numbers | 18.00 | 6,523 | 1,17,414 |
| 52 | Transportation, installation and wiring of Rotary key transmitters/KLCR on Hylam sheet board including wiring & fixing of push button bell switch on Hylam sheet of 12mm including termination, painting & lettering. The sundry materials such as Hylam sheet, push bell switch etc. to be supplied by contractor. | Numbers | 18.00 | 1,553 | 27,954 |
| 53 | Supply of Electrically operated lifting barrier (ELB) 24V/110V DC with hand generator having boom length of 9.76 meter/32 feet confirming to IS:277 or latest with Base metal as IS: 513 grade CR3 or latest. The boom shall be painted alternately with 300 mm bands of black and yellow colour and additionally provided with luminous stripes (reflective tape) as per RDSO Drg. No. RDSO/S 11600 or latest, complete set as per Specification No. RDSO/SPN/ 208/2012 Ver. 2 Amd.1.0 or latest. List of spares & tool kit items mentioned in Para 10 of RDSO Specification shall also be supplied. | Set | 9.00 | 2,73,937 | 24,65,433 |
| 54 | Transportation, installation, testing and commissioning of Electric lifting barrier (ELB) which includes excavation of pit, casting of foundations, fixing of pedestals, Boom rest etc., installation and wiring of control panel, booms for level crossing gate complete in all respect including provision of boom locking arrangements with fixing of boom light box, stop board boom rest and equipment of operation of gate from control panel, painting, lettering with following accessories:- (i) 2 (two) nos. lifting barriers with all accessories. (ii)1 (one) Control panel (iii) Positive boom locking arrangements for above. (iv) Emergency crank handle attachment (v) Timer unit to adjust the time for operating the barrier (vi) Fixing of Hooters/Flashers on either side of gate barrier. | Set | 9.00 | 53,846 | 4,84,614 |
| 55 | Supply of Sliding Boom Gate as per drawing no. E. Rly Signal workshop/HWHs Drg No. SW/SA/29/768 or latest. This includes supply of 8 Nos. Key lock 'E' type with key as per Specification No. IRS:S-30/64 or latest conforming to Drg No. 3376/M with latest amendment. Ward number to be decided by Railway Engineer & to be fixed on MS plate as mentioned in the drawing and it includes supply of all the nut and bolt with washer, Anchor Bolt and Pad lock 6 (Six) lever (make - Godrej or better) with three keys etc, to make the system complete functional. | Set | 9.00 | 1,23,728 | 11,13,552 |
| 56 | Transportation, installation, testing and commissioning of Emergency Sliding Boom at LC gates which includes casting of total 10 nos. concrete foundation including surrounding earthwork, fixing of lock post, clamps, welding of channel, cutting of rail post if required as per site condition. Note: All materials to be supplied by the contractor except Sliding Boom gates & key lock 'E' type. | Set | 9.00 | 49,416 | 4,44,744 |
| 57 | Supply of GI Sheet Boom of 9.76 meter/32 feet long for Electrically operated lifting barrier confirming to IS: 277 or latest with Base metal as IS: 513 grade CR3 or latest. The boom shall be painted alternately with 300 mm bands of black and yellow colour and additionally provided with luminous stripes (reflective tape) as per RDSO Drg. No. RDSO/S 11600 or latest as per Specification No. RDSO/SPN/ 208/2012 Ver. 2 Amd.1.0 or latest. | Set | 9.00 | 10,706 | 96,354 |
| 58 | Supply of Stop Board for Electrically operated lifting barrier of 600 mm diameter disc made from minimum 20 SWG GI Sheet with a vertical Stiffening "V" or "U" bend in the middle having red reflector buttons/ luminous strips facing the road traffic. The disc shall be marked with "STOP" sign of 50mm width in white luminous paint/ stripes as per Specification No. RDSO/SPN/208/2012 Ver 2.0 Amd.1.0 or latest. | Numbers | 36.00 | 1,018 | 36,648 |
| 59 | Supply of 25 watt horn, dual tone warning bell hooter for L.C gate and working on 110 VAC/24V DC. The contractor should get confirmation from Railway before placing an indent to manufacturer/supplier. | Numbers | 18.00 | 1,868 | 33,624 |
| 60 | Supply of Control cum Indication panel Domino Type at Mid-section interlocked LC Gate/IBS/Siding motor operated point operation panel /Non-Interlocking panel of Single/Double line section as per RDSO Specification No. RDSO/SPN/186/2004Rev. 2.0 or latest. Size of each Domino will be 54 x 34 mm2. Control Panel includes panel rest, front and side table, complete with switches, push button, termination of cables, painting and lettering as required. This also includes 10% spare of panel LED's, Dominos and button assemblies, counter, keys, buzzer etc. Note: Size of the panel will depend upon the number of Dominos required as per Front Plate Diagram. | Set | 9.00 | 60,614 | 5,45,526 |
| 61 | Installation, wiring, testing and commissioning of the Control cum Indication panel type at Mid-section interlocked LC Gate/IBS/Siding motor operated point operation panel /Non- Interlocking panel of Single/Double line section as per approved interlocking plan, FPD, circuit diagram etc | Set | 9.00 | 6,062 | 54,558 |
| 62 | Modification of existing Domino type panel for undertaking the work of Double distant/Auto signal. The distant/auto signals may be shown externally/through alteration in the existing panel in SM room. It includes drawing & design, all indoor wiring, cable termination and modification of relay rack in indoor and location box at outer if required for commissioning Double distant/Auto signal. Note: This includes all required materials such as panel LED's, Dominos a n d button assemblies, counter, keys, buzzer etc. for commissioning. | Station | 1.00 | 1,30,624 | 1,30,624 |
| 63 | Supply of Master Telephone Unit with voice logging facility for LC Gate Telephone System as per Specification No. RDSO /SPN/TC/51/2011 Rev 1.0 or latest. | Numbers | 9.00 | 51,788 | 4,66,092 |
| 64 | Supply of Slave Telephones unit for LC Gate Telephone System as per Specification No. RDSO /SPN/TC/51/2011 Rev 1.0 or latest. | Numbers | 54.00 | 5,734 | 3,09,636 |
| 65 | Supply of Power Supply System having both 12V & 24 V DC Output including battery charger with minimum 7AH, 24V DC MF Battery. 12V DC supply shall be connected to the Station Telephone Unit & 24V DC shall be fed to Line Circuit for LC gate telephone system as per Specification No. RDSO/SPN/TC-51/2011, Rev 1.0 or latest. | Numbers | 9.00 | 7,139 | 64,251 |
| 66 | Dismantling of existing interlocked LC gate and other associated S&T gears. All the released material will be transported to the concerned SSE/Store or KGP workshop as instructed by site engineer. | Set | 9.00 | 3,113 | 28,017 |
| 67 | Supply of Earth Electrode as per Drawing No. 19-D6 of SEM-2021 or latest. GI pipe confirming to IS:1239 or latest of 3.17 mm thickness, minimum 2.5 m long, 50.8 mm diameter, 4.76 mm diameter drilled holes staggered at distance of 152.4 mm. | Set | 180.00 | 2,712 | 4,88,160 |
| 68 | Excavation of earth pit, placing & fixing of Earth electrode with construction of cement enclosure to SEM Drawing No. 19-D6 and drawl of 6 SWG GI/Copper c a b l e from earth electrode to goomties/relay room/cabin/station, etc. and drawl of MS flat 35mm x 6mm for signal post/Location box shall be used as the case may be, including fixing at both ends of the wire/MS flat. This includes transportation of materials. Note: Materials such as charcoals, salt, sal ammoniac, 6 SWG GI wire, copper lugs with Steel bolts & nuts etc. shall be supplied by the contractor. MS flat 35mm x 6mm/Copper cable shall be supplied by Railway. | Numbers | 180.00 | 1,791 | 3,22,380 |
| 69 | Supply of 35 mm x 6 mm thick MS Flat Plate Strip as per IS: 226-1975 or latest for earth connection to Signal post, L/Box etc. | Metre | 900.00 | 166 | 1,49,400 |
| 70 | Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/ RDSO/E&B/002 or latest are as under, (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 No. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No. (e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No. It also includes supply of (i) 35 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter. | Set | 30.00 | 17,719 | 5,31,570 |
| 71 | Installation of Single Maintenance Free Earth pit as per RDSO Drawing No. SDO / RDSO/ E&B/001 which includes the following, a) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site engineer. | Set | 30.00 | 6,098 | 1,82,940 |
| 72 | Supply of 50 mm x 6 mm Galvanised steel tape for interconnecting the earth pits. | Metre | 300.00 | 557 | 1,67,100 |
| 73 | Digging a trench to a minimum depth of 0.5 meter and laying 50 mm X 6 mm bare Galvanized steel tape connecting all the earth pits. Carrying out exothermic weld connections on all the earth electrodes. It shall be ensured that the distance between any two earth electrodes shall be minimum 3 meter (length of the earth electrode) and maximum up to 6 meter (twice the length of the earth electrode) to avoid mutual resistance effects. Earth enhancement compound of 10 Kg along each meter also to be spread along the Galvanized steel tape. | Metre | 300.00 | 90 | 27,000 |
| 74 | Supply of 25mm x 2 mm bare copper strips or 8mm round solid copper in the equipment room. | Metre | 390.00 | 1,258 | 4,90,620 |
| 75 | Routing and termination of 25 mm X 2 mm copper tape/8 mm solid copper round conductor which is to be fixed inside the equipment room with 60 mm, 6KVA insulation studs including supply of insulation studs. The separation of the two successive insulation studs should be 600mm apart. | Metre | 390.00 | 90 | 35,100 |
| 76 | Routing and connecting of all the equipment in the equipment/relay room to SEEB with 10 sq. mm copper cable using copper lugs with stainless steel nut and bolts and fixtures. The work includes laying and routing the copper cable in PVC / conduits and fixing them on wall. The PVC/conduit pipe to be supplied by Railway. | Metre | 180.00 | 58 | 10,440 |
| 77 | Routing and connecting of all the SPDs in the equipment room/SEEB to MEEB with 16 sq. mm copper cable using copper lugs with stainless steel nut and bolts. The work includes laying and routing the copper cable in PVC / conduits and fixing them on wall. The PVC/conduit pipe to be supplied by Railway. | Metre | 180.00 | 58 | 10,440 |
| 78 | Supply and Installation of class A type Lightening Protection System as per following specification are as under, (i) Lightening arrester technology: Advance Early Steamer Emission. Material: High current discharge stainless steel. International standards: NFC 17- 102 or latest., (ii) Mast material: minimum 2 meter FRP pipe and minimum 3 meter high-grade aluminium/steel. Dimension: 50mm., (iii) Down conduct cable: 50 Sq. mm PVC insulated copper cable having 75m length, (iv) Lightning strike counter: 6 digits counter, Current sensitivity: 1KA to 200 KA, 8/20 & 10/350 micro/Sec. induction Shunt: 0.5 micro. (v) Two (02) No. of maintenance Free Earth with all required accessories as per Specification No. RDSO/SPN/197/ 2016 Ver 1.0 or latest such as copper cables, strips etc. | Set | 9.00 | 1,43,762 | 12,93,858 |
| 79 | Supply of Class B & C Surge protection Device (SPD) -Type I & II with Visual Indication and Potential free contact to remote monitoring as per Specification No. RDSO/SPN/165/2023 Ver 4.0 or latest and IEC standard 61643 or latest and IEC 62304-5 or latest for Single phase 230V AC application with handling Lightning surges of 10/350 microseconds and Switching surges of 8/20 microseconds .One Set consists of 3 nos. of SPD (2 No. of B Class (L-N, N-E) and one no. of C Class (L-N) all enclosed in a Box with KEMA or VDE certified as per latest IEC 61643-11-2011 Standard or latest. Class B & C Surge protection device required with Three modules only. | Set | 36.00 | 6,007 | 2,16,252 |
| 80 | Installation of Class B & C Surge protection Device (SPD) -Type I & II. All fitting material to be provided by the contractor. | Set | 36.00 | 443 | 15,948 |
| 81 | Supply of Earth Leakage Detector (ELD) - 8 channels as per Specification No. RDSO/SPN/ 256/2002 or latest. | Set | 9.00 | 95,718 | 8,61,462 |
| 82 | Fabrication of stand/rack, installation, testing & commissioning of Earth Leakage Detector (ELD)- 8 channels as per Specification No. RDSO/SPN/ 256/2002 or latest. | Set | 9.00 | 5,947 | 53,523 |
| 83 | Supply, Installation, Testing & Commissioning of Networkable Single loop addressable Fire alarm Control panel expandable upto 2 loops & interface with GSM/LTE module working as per RDSO/SPN/217/2021 ver-3 or latest. The control panel shall be networkable to Zonal /Divisional Headquarters preferably over TCP lP/OFC media converter and shall have clock synchronization facility. This schedule includes supply of TCP IP converter/Networking card/OFC media converter. The control panel shall have provision of Graphical software to enable remote monitoring of entire fire detection and alarm system of a station from Head Quarters. The control panel shall be designed to work on power supply of 110V/230V AC as well as on DC battery backup of adequate capacity to work upto 24 hrs. Backup. The Power supplies like batteries and chargers shall be supplied by the contractor. The Control Panel shall have means for the user to visualize and interact with the complete Automatic Fire Detection and Alarm System layout through a user- friendly software executable on a standard Windows based Personal Computer. It shall be possible to download data and extend alarms from Control Panel through suitable ports like RS485/RS232/USB/TCP/IP into a PC/Laptop available with SSE at the installation and remote location (Divisional Control room) operating on Windows platform. The software for downloading and analysing fault data shall be provided & shall be compatible with the latest windows operating system. Detection, actuation, and control system shall have provision for automatic as well as manual operation. The control panel should have provision to connect a GSM/LTE module duly providing compatible SIM with SMS facility on minimum of 5 numbers (users). Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15. | Set | 9.00 | 1,57,054 | 14,13,486 |
| 84 | Supply, installation testing & commissioning of Heat and smoke multi sensor with inbuilt fault isolator (open/short circuit in loop) as per specification No. RDSO/SPN/217/2021 ver-3 or latest and required to be provided at suitable locations inside the diesel generator room, battery room, ASM room, power equipment room, non air conditioned RR, CCTV control & equipment rooms, way side OFC room and other S&T service rooms as directed by the Railway site Engineer. The location of fixing is to be meticulously decided so that full advantage of the system is achieved. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest. | Numbers | 108.00 | 4,328 | 4,67,424 |
| 85 | Supply, Installation, Testing & commissioning of Audio Visual alarm (Hooter and strobe) controlled through addressable control model. It shall be preferably flashing type Red/White colour. It shall be preferably with Piezoelectric type sounder. The sound level shall be preferably adjustable type up to 90 dB at a distance of 1 m as per specification No. RDSO/SPN/217/2021 Ver - 3 or latest. Note: Spares cost are also included & to be supplied as per RDSO para no. 4.15 or latest. | Numbers | 9.00 | 8,943 | 80,487 |
| 86 | Supply, Installation and Testing, commissioning of Addressable and resettable Manual call point with inbuilt fault isolator (open/short circuit in loop) status LED for alarming & standby mode as per specification No. RDSO/SPN/217/2021 ver-3 or latest. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest. | Numbers | 9.00 | 6,161 | 55,449 |
| 87 | Supply, installation, testing & communication of Linear Heat Sensing (LHS)/Linear Heat Detection (LHD) Interface module with all accessories for integration with main line fire alarm control panel as per RDSO specification No. RDSO/SPN/217/2021 ver-3 or latest. It should be UL/FM/Vds/LPCB approved/listed. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest. | Numbers | 9.00 | 92,761 | 8,34,849 |
| 88 | Supply, Installation Testing and commissioning of Analogue type Linear Heat Sensing cable/Linear Heat Detector hollow metallic pneumatic tube type with required module to be integrated on main Fire Alarm Panel as per specification No. RDSO/SPN/217/2021 ver-3 or latest. It shall be laid in all cables tray located in power equipment room, relay room & telecom room and should be UL/FM/Vds/LPCB approved/listed. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest. | Metre | 450.00 | 532 | 2,39,400 |
| 89 | Supply, Installation, Testing, Commissioning of Auto Telephone Dialler (GSM) Module to send the pre-recorded message, fire and fault massage, to multiple mobile numbers, programmed earlier, complying to the RDSO/SPN/217/2021 ver-3 or latest. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest. | Numbers | 9.00 | 10,057 | 90,513 |
| 90 | Supply, Installation Testing and commissioning of FRLS/Fire Survival Circuit Integrity Cables of size 2C X 1.5 Sq. mm with all accessories certified by UL/FM/Vdc/LPCB/BRE global or any recognised Lab by GOI for connection of Fire Alarm devices specification No. RDSO/SPN/217/2021 ver-3 or latest. Note: Spare cost is also included & to be supplied as per RDSO para no. 4.15 or latest. | Metre | 450.00 | 169 | 76,050 |
| 91 | Supply of CO2 Fire extinguisher 4.5 kg capacity confirming to IS 15683: 2018 or latest with ISI mark provided with all fittings and accessories. | Numbers | 18.00 | 4,417 | 79,506 |
| 92 | Supply of multipurpose Computer chair. Model: CH-7B. Make: Godrej or better. | Numbers | 18.00 | 3,953 | 71,154 |
| 93 | Supply of Steel Table with sunmica Top with storage on both sides Unitised table. Model: T-9. Make: Godrej or better. | Numbers | 9.00 | 23,490 | 2,11,410 |
| 94 | Supply of Power Supply Unit for Way Station DTMF Telecom installations as per the RDSO Specification. IRS/TC/72/97 or latest with 12V/7AH. Make: Indisco/Epsilon/Bentron or better | Numbers | 18.00 | 3,897 | 70,146 |
| 95 | Cement Concrete of proportion 1:3:6 (Cement: Sand: Stone chips of 25mm nominal size) for miscellaneous works. It includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). Note: All materials required for foundation are to be supplied by the contractor. | cum | 18.00 | 3,647 | 65,646 |
| 96 | Supply of MCB 1X63A,230/416V, DP, complete with HRC type back up fuses with indication, housed in a weather proof MS box suitable for fixing on AT mast with powder coating paint. Make of MCB: L&T/Siemens/ABB/Havells or better. | Set | 34.00 | 4,987 | 1,69,558 |
| 97 | Supply of C series MCB 2 POLE 32 AMP with metal enclosure. Make: Schneider/Legrand/L&T/Havells. | Numbers | 36.00 | 621 | 22,356 |
| Schedule total | ₹7,00,08,103.5 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .