Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.3 L+₹3.1 L (9.65%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹35.7 L+₹3.5 L (10.9%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹36.0 L+₹3.8 L (11.7%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹37.2 L+₹4.9 L (15.3%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
| Sl No | Description | Qty | Unit | R D Bansal L2 | kailu construction co L1 | P S BUILDERS L3 | KULBHUSHAN AGGARWAL L4 | Darshan Singh Ghai and Sons L7 | Standard engineers L5 | HARPAL ENGINEERS AND BUILDERS L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.50 m wide and not exc. 1.50 m in depth in soft / loose soil for foundation etc. or for laying of pipes and fittings, cables, HT / LT poles, stay assembly etc includinguding forming bottom surfaces to required level and slope and getting out ETC complete, all as specified and directed. | 650 | CUM | 85 ₹55,250 | 150 ₹97,500 | 98 ₹63,700 | 65 ₹42,250 Lowest | 120 ₹78,000 | 65 ₹42,250 Lowest | 90 ₹58,500 |
| 2.00 | Excavation in trenches not exceeding 1.50 m wide and depth exceeding 1.50 metre and not exceeding 3.00 metre in soft / loose soil for foundation etc. or for laying of pipes and fittings, cables, HT / LT poles, stay assembly etc including forming bottom surfaces to required level and slope and getting out etc complete, all as specified and directed. | 2 | CUM | 200 ₹400 | 100 ₹200 | 98 ₹196 | 200 ₹400 | 150 ₹300 | 400 ₹800 | 10 ₹20 Lowest |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer complete all as specified and directed. | 180 | CUM | 15 ₹2,700 | 10 ₹1,800 Lowest | 58 ₹10,440 | 25 ₹4,500 | 50 ₹9,000 | 30 ₹5,400 | 30 ₹5,400 |
| 4.00 | Removing surplus excavated material to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed. | 470 | CUM | 25 ₹11,750 | 10 ₹4,700 Lowest | 18 ₹8,460 | 25 ₹11,750 | 40 ₹18,800 | 25 ₹11,750 | 30 ₹14,100 |
| 5.00 | Material and Labour for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 8cm before laying the cable and 15cm after laying the cable complete all as specified and directed.
Note :- Item shall be executed and measured as per specification of SSR part I and punned thickness be used for measurement. | 135 | CUM | 350 ₹47,250 | 200 ₹27,000 Lowest | 258 ₹34,830 | 300 ₹40,500 | 500 ₹67,500 | 300 ₹40,500 | 200 ₹27,000 Lowest |
| 6.00 | Supply and Laying jointing and testing XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed) grade cross sectional area 185 sqmm 3 core confirming to IS : 7098-1985 laid in trenches, in floor, in duct, through pipes or along the pole complete, all as specified and directed | 1,650 | RM | 1,435 ₹23,67,750 | 1,340 ₹22,11,000 Lowest | 1,458 ₹24,05,700 | 1,500 ₹24,75,000 | 1,550 ₹25,57,500 | 1,540 ₹25,41,000 | 1,550 ₹25,57,500 |
| 7.00 | Supply and Laying jointing and testing XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed) grade cross sectional area 95 sqmm 3 core confirming to IS : 7098-1985 laid in trenches, in floor, in duct, through pipes or along the pole complete, all as specified and directed | 640 | RM | 1,039 ₹6,64,960 | 831 ₹5,31,840 Lowest | 958 ₹6,13,120 | 1,000 ₹6,40,000 | 950 ₹6,08,000 | 1,040 ₹6,65,600 | 1,000 ₹6,40,000 |
| 8.00 | Material and Labour for providing PCC 1:4:8 type D:2 using 40mm graded crushed stone aggregate as in foundation for pole/stay assembly foundation coping of poles etc., complete all as specified and directed | 0.65 | CUM | 2,000 ₹1,300 | 2,000 ₹1,300 | 1,258 ₹817.7 Lowest | 2,000 ₹1,300 | 3,000 ₹1,950 | 4,000 ₹2,600 | 2,000 ₹1,300 |
| 9.00 | Material and Labour for roviding PCC 1:3:6 type C:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation coping of poles etc., complete all as specified and directed | 8 | CUM | 2,500 ₹20,000 | 1,000 ₹8,000 Lowest | 1,558 ₹12,464 | 2,000 ₹16,000 | 3,000 ₹24,000 | 2,000 ₹16,000 | 2,000 ₹16,000 |
| 10.00 | Material and Labour PCC 1:2:4 type B:2 using 40mm graded crushed stone aggreate as in coping of poles incl taking down of old copping of the pole, complete all as specified and directed | 0.5 | CUM | 3,500 ₹1,750 | 2,000 ₹1,000 Lowest | 2,158 ₹1,079 | 2,000 ₹1,000 Lowest | 4,000 ₹2,000 | 2,000 ₹1,000 Lowest | 2,000 ₹1,000 Lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
28 Jul 2025, 6:00 pmClosed
CWE Amritsar
HQ CWE Amritsar
SPL REPAIR REPLACEMENT OF HT OH LINE WITH HT UG CABLE OF FEEDERS NO 5 FROM 66 KV MRS TO 2 3 GR AND NUMBER 10 POSTS AT KV AT TIBRI MIL STN UNDER GE GURDASPUR
2025_MES_708904_2
83021/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Gurdaspur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹76,000
Yes
31 Aug 2025
7 Jul 2025
4 Aug 2025
7 Jul 2025
28 Jul 2025
21 Jul 2025
Amount
Excavation in trenches not exceeding 1.50 m wide and not exc. 1.50 m in depth in soft / loose soil for foundation etc. or for laying of pipes and fittings, cables, HT / LT poles, stay assembly etc includinguding forming bottom surfaces to required level and slope and getting out ETC complete, all as specified and directed.
Excavation in trenches not exceeding 1.50 m wide and depth exceeding 1.50 metre and not exceeding 3.00 metre in soft / loose soil for foundation etc. or for laying of pipes and fittings, cables, HT / LT poles, stay assembly etc including forming bottom surfaces to required level and slope and getting out etc complete, all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer complete all as specified and directed.
Removing surplus excavated material to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed.
Material and Labour for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 8cm before laying the cable and 15cm after laying the cable complete all as specified and directed. Note :- Item shall be executed and measured as per specification of SSR part I and punned thickness be used for measurement.
Supply and Laying jointing and testing XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed) grade cross sectional area 185 sqmm 3 core confirming to IS : 7098-1985 laid in trenches, in floor, in duct, through pipes or along the pole complete, all as specified and directed
Supply and Laying jointing and testing XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed) grade cross sectional area 95 sqmm 3 core confirming to IS : 7098-1985 laid in trenches, in floor, in duct, through pipes or along the pole complete, all as specified and directed
Material and Labour for providing PCC 1:4:8 type D:2 using 40mm graded crushed stone aggregate as in foundation for pole/stay assembly foundation coping of poles etc., complete all as specified and directed
Material and Labour for roviding PCC 1:3:6 type C:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation coping of poles etc., complete all as specified and directed
Material and Labour PCC 1:2:4 type B:2 using 40mm graded crushed stone aggreate as in coping of poles incl taking down of old copping of the pole, complete all as specified and directed
Taking down carefully from poles ACSR conductor, any size, complete all as specified and directed
Taking down carefully from poles cross arms of any size including clamps nuts bolts etc omplete all as specified and directed
Taking down carefully from poles LT insulators, any type, complete all as specified and directed
Supply and laying un-reinforced precast concrete cable cover, class HV, type I, flat, size 300 mm x 180 mm x 40 mm laid flat in trenches over the cable with the length of cable cover perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed .
Supply and erecting in Steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) including painting with two coats of aluminium paint over a coat of red oxide primer including 5 Nos alternate bands/ strips of 30cm wide each with two coats of radium spray/synthetic enamel paint (Red and Yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking of pole number with thick synthetic enamel paint (white) including preparation of surface complete all as specified and directed.
Material and Labour for cable protection GI tubing light grade fixed long the pole/under road/along the wall of size 100mm bore with necessary clamps all as directed.
Material and Labour for cable protection GI tubing light grade fixed long the pole/under road/along the wall of size 80mm bore with necessary clamps all as directed.
Material and Labour for crossarms in replacement , bracing, supports, clamps and brick plates, fabricated from staructural steel section including nut bolts washers including weldingbending , cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide all specified.
Material and labour for stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including FI clamps 50 x 6 mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long, stay bow 400 x14mm, GI steel plate 300x300x6mm, Disc type insulator, porcelain,vitreous 145mm high and 255mm dia ball and socket type, white, brown or green clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate No. 1 of SSR part - I 2009 on Page No 495 compelete, all as specified and directed. (Note :- Earth work, PCC work, and Insulator measured and paid separately)
Materaial and labour for end termination outdoor Heat shrinkable joint suitable for 11KV cable 50 to 95 sqmm 3 core all as specified and directed.
Materaial and labour for end termination outdoor Heat shrinkable joint suitable for 11KV cable 120 to 185 sqmm 3 core all as specified and directed.
Material and labour in replacement danger notice plate for HT pole of size 25 cm x 20 cm of 1.6 mm thick mild steel sheet viterious enamaled white with letter figur and conventional skull and bones "DANGER" (English, Punjabi and Hindi) in signal red colour and fixed with MS clamps made of 25mm x 3mm MS flat Iron bolts nuts complete including two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed. complete, all as specified and directed.
Materaial and labour for precast cement concrete RCC (1:2:4 type B-1) route indicator of size 150x150x900mm with 8 mm dia steel einforcement @ 100 c/c both ways duly engraved " HT CABLE/HT JOINT /FEEDER NO " with two coats synthetic enamel paint first quality fixd with (PCC 1:3:6) below ground level of size 30x30x300mm complete ,all as specified and directed. Note :- Quoted unit rate is deemed to be included the necessary cost of excavation, returning filling and removal etc.
Labour only for drilling hole under the road with the help of bocki / by manual or by machine for crossing GI tubing of any size for cable protection complete , all as specified and directed
R D Bansal (BID ID -3373523)
P S BUILDERS (BID ID -3373952)
KULBHUSHAN AGGARWAL (BID ID -3374646)
Standard engineers (BID ID -3366801)
HARPAL ENGINEERS AND BUILDERS (BID ID -3374540)
Darshan Singh Ghai and Sons (BID ID -3370072)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .