Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.5 L+₹33,654 (1.24%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹29.8 L+₹2.7 L (10.0%)Rejected-Finance H NO 1237 PANA PAPOSIAN NARELA NORTH WEST DELHI NEW DELHI 110 040 | NEW DELHI | NORTH WEST DELHI | DELHI | 110040 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹36.4 L+₹9.3 L (34.2%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹36.8 L+₹9.6 L (35.5%)Rejected-Finance HOUSE NO 142 GALI NO 07 PREM VIHAR NANGLI SAKRAWATI NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | M/S HARINDER SINGH L3 | S.R. Constructions L4 | M/S Malik Construction Corporation L7 | J B ELECTRICALS L6 | S K ENGINEERS AND CONTRACTOR L5 | M/S ADHIKARI CONSTRUCTION CO. L2 | Vijeta Solutions L1 | Vee em Traders L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending complaints from 08:45 Hrs to 16:45 Hrs for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block for uninterrupted electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed. | 4,500 | Each Complaint | 40 ₹1,80,000 | 35 ₹1,57,500 | 30 ₹1,35,000 Lowest | 50 ₹2,25,000 | 43 ₹1,93,500 | 149 ₹6,70,500 | 55 ₹2,47,500 | 90 ₹4,05,000 |
| 2.00 | All as per Srl item No. 1.00 here-in-before but attending complaints From 16:45 hrs to 23:45 Hrs. | 950 | Each Complaint | 30 ₹28,500 Lowest | 35 ₹33,250 | 30 ₹28,500 Lowest | 80 ₹76,000 | 43 ₹40,850 | 99 ₹94,050 | 55 ₹52,250 | 90 ₹85,500 |
| 3.00 | All as per Srl item No. 1.00 here-in-before but attending complaints From 23:45 hrs to 08:45 Hrs. | 200 | Each Complaint | 50 ₹10,000 | 35 ₹7,000 | 30 ₹6,000 Lowest | 90 ₹18,000 | 44 ₹8,800 | 199 ₹39,800 | 55 ₹11,000 | 299 ₹59,800 |
| 4.00Notes for Srl item Nos.01, 02 & 3 :- 1. The Area for attending complaints of Manekshaw Centre and Khypber Line and Contractor shall provide adequate numbers of tradesmen (electrician) alongwith helper to attend the complaints all the above areas in all working days including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. | |||||||||||
| 5.00 | Taking down copper/aluminium point wiring (light, fan, socket or pwer) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets etc making good disturbed surfaces of walls, floors etc. complete all as specified and as directed. | 515 | Per point | 5 ₹2,575 Lowest | 5 ₹2,575 Lowest | 20 ₹10,300 | 20 ₹10,300 | 5 ₹2,575 Lowest | 9 ₹4,635 | 5 ₹2,575 Lowest | 29 ₹14,935 |
| 6.00 | M&L for point wiring with multi stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through suitable concealed/existing PVC conduit including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm multi stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good the disturbed surfaces of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour wash/white wash as the existing finishes etc. complete all as specified and as directed.
Notes :- 1. The rate is inclusive of cutting/chasing and making good the distrubed surface in CM 1:3 and same surface to be finished with the adjoining surfaces with ODB/colour wash/white wash etc. complete.
2. At roof slab, where there is burnt/blockage in the existing conduit, wiring will be done through new PVC conduit and rates are inclusive in above quoted item.
3. The rate is inclusive for if old wiring is normal wiring, then new wiring for modular point wiring to be done.
(a) One light /fan/Bell point/security light controlled by one way switch | 150 | Per Point | 300 ₹45,000 | 250 ₹37,500 | 300 ₹45,000 | 280 ₹42,000 | 221 ₹33,150 | 199 ₹29,850 | 149 ₹22,350 Lowest | 299 ₹44,850 |
| 7.00 | All as per Srl item No.6.00 here-in-before, but for one 3 pin socket outlet 5 amps on same board. | 15 | Per Point | 100 ₹1,500 | 50 ₹750 Lowest | 100 ₹1,500 | 300 ₹4,500 | 233 ₹3,495 | 199 ₹2,985 | 159 ₹2,385 | 90 ₹1,350 |
| 8.00 | All as per Srl item No.6.00 here-in-before, but for one 3 pin socket outlet 5 amps on independent board with cable 1.5 Sqmm for main current and 1.5 sqmm as earth wire. | 30 | Per Point | 300 ₹9,000 | 250 ₹7,500 | 300 ₹9,000 | 290 ₹8,700 | 243 ₹7,290 | 99 ₹2,970 Lowest | 159 ₹4,770 | 299 ₹8,970 |
| 9.00 | All as per Srl item No.6.00 here-in-before, but for 3/6 pin socket outlet, 15 Amps on independent board with cable 2.5 Sqmm for main current and 2.5 Sqmm as earth wire as power point” | 20 | Per Point | 300 ₹6,000 | 280 ₹5,600 | 400 ₹8,000 | 390 ₹7,800 | 263 ₹5,260 | 199 ₹3,980 Lowest | 199 ₹3,980 Lowest | 499 ₹9,980 |
| 10.00 | All as per Srl item No.6.00 here-in-before, but for One 3/6 Pin socket outlet, 20 Amp on independent board with cable 4 Sqmm for main current and neutral and 4 Sqmm as earth wire as AC point cable 4 Sqmm for main current and 4 sqmm as earth wire as power point. | 10 | Per Point | 390 ₹3,900 | 350 ₹3,500 | 500 ₹5,000 | 480 ₹4,800 | 283 ₹2,830 | 199 ₹1,990 Lowest | 259 ₹2,590 | 900 ₹9,000 |
Tender Value
₹40.0 L
EMD Value
₹80,000
Closing Date
4 Sept 2025, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
MAINT AND REPAIR/REPLACEMENT OF UNSERVICEABLE WIRING MCBs, DBs, LIGHTS SUMMER AND WINTER APPLIANCES INCLUDING ATTENDING DAY TO DAY PETTY COMPLAINTS AT MANEKSHAW CENTRE AND KHYBER LINE UNDER AGE E/M OF GE SOUTH DELHI CANTT-10
2025_MES_725056_1
GE/TOKEN-58/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹80,000
Yes
14 Oct 2025
7 Aug 2025
6 Sept 2025
7 Aug 2025
4 Sept 2025
21 Aug 2025
Amount
Attending complaints from 08:45 Hrs to 16:45 Hrs for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block for uninterrupted electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed.
All as per Srl item No. 1.00 here-in-before but attending complaints From 16:45 hrs to 23:45 Hrs.
All as per Srl item No. 1.00 here-in-before but attending complaints From 23:45 hrs to 08:45 Hrs.
Notes for Srl item Nos.01, 02 & 3 :- 1. The Area for attending complaints of Manekshaw Centre and Khypber Line and Contractor shall provide adequate numbers of tradesmen (electrician) alongwith helper to attend the complaints all the above areas in all working days including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill.
Taking down copper/aluminium point wiring (light, fan, socket or pwer) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets etc making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring with multi stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through suitable concealed/existing PVC conduit including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm multi stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good the disturbed surfaces of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour wash/white wash as the existing finishes etc. complete all as specified and as directed. Notes :- 1. The rate is inclusive of cutting/chasing and making good the distrubed surface in CM 1:3 and same surface to be finished with the adjoining surfaces with ODB/colour wash/white wash etc. complete. 2. At roof slab, where there is burnt/blockage in the existing conduit, wiring will be done through new PVC conduit and rates are inclusive in above quoted item. 3. The rate is inclusive for if old wiring is normal wiring, then new wiring for modular point wiring to be done. (a) One light /fan/Bell point/security light controlled by one way switch
All as per Srl item No.6.00 here-in-before, but for one 3 pin socket outlet 5 amps on same board.
All as per Srl item No.6.00 here-in-before, but for one 3 pin socket outlet 5 amps on independent board with cable 1.5 Sqmm for main current and 1.5 sqmm as earth wire.
All as per Srl item No.6.00 here-in-before, but for 3/6 pin socket outlet, 15 Amps on independent board with cable 2.5 Sqmm for main current and 2.5 Sqmm as earth wire as power point”
All as per Srl item No.6.00 here-in-before, but for One 3/6 Pin socket outlet, 20 Amp on independent board with cable 4 Sqmm for main current and neutral and 4 Sqmm as earth wire as AC point cable 4 Sqmm for main current and 4 sqmm as earth wire as power point.
S&F Switch modular type, 1 Module, 6 Amps one way complete all as specified and as directed.
S&F Socket outlet modular type 2M, 2/3 pin, 6 Amp complete all as specified and as directed.
S&F Switch modular type 1M, 16 Amp with red indication light complete all as specified and as directed.
S&F Socket outlet modular type 1M, 16 Amp complete all as specified and as directed.
S&F switch modular type, 2 Module combined shuttered, 5 pin 6/16 Amps one way complete all as specified and as directed.
S&F electric bell ding dong, 1 Module, AC 230 V complete all as specified and as directed.
S&F Bell push modular type 1M 5/6 Amp complete all as specified and as directed.
S&F Electronic fan regulator, Module type 2 M, 4 steps complete all as specified and as directed.
S&F AC box with MCB 20 Amp complete with metal box and 3 Pin top plug complete all as specified and as directed. Note : Rates are inclusive of cutting/chases for mounting metal box on wall and making good the disturbed surfaces with OBD/Colour wash/ white wash and wall care putty etc, where ever required.
S&F in repair Switch modular type, 1 Module, 6 Amps one way complete all as specified and as directed.
S&F in repair switch modular type 1 M 6 Amp 2 way complete all as specified and as directed.
S&F Socket outlet modular type 2M, 2/3 pin, 6 Amp complete all as specified and as directed.
S&F Switch modular type 1M, 16 Amp complete all as specified and as directed.
S&F Socket outlet modular type 2M combined shuttered, 5 pin, 6/16 Amp complete all as specified and as directed.
S&F Electronic fan regulator, Module type 2 M, 4 steps complete all as specified and as directed.
S&F electric bell ding dong, 1 Module, AC 230 V complete all as specified and as directed.
S&F Bell push modular type 1M 5/6 Amp complete all as specified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal boxes of required size minimum 2mm thickness and factory painted with stove enameled black paint with top cover 3mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing) complete all as specified and as directed. Note:- The rate is inclusive cutting/chasing and making good distrubed surface with cement mortar 1:3 adn same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash completed.
All as per item No.28.00 here-in-before but for one 3 pin socket outlet, 5/6 Amps, independent, with cable 1.5 Sqmm size suitable concealed PVC/MS conduit complete all as specified and as directed.
All as per item No.28.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
All as per item No.28.00 here-in-before but for one socket outlet 15 Amps on independent board with cable 2.5 Sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit complete all as specified and as directed.
All as per item No.28.00 here-in-before but for one AC point controlled using cable of 4 Sq mm for phase and neutral and 4 sqmm for earthing.
S&F of switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
S&F of socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose as per sample complete all as specified and as directed.
S&F of switch piano flush type 15/16 Amps SP one way as per sample complete all as specified and as directed.
S&F of universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type as per sample complete all as specified and as directed.
S&F of 0-4 step type electronic regulator for ceiling fan 1200/1400 sweep, 240 V as per sample complete all as specified and as directed.
Supply and fixing switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
Supply only socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose as per sample complete all as specified and as directed.
Supply and fix in repair in repair switch piano flush type 15/16 Amps SP one way as per sample complete all as specified and as directed.
Supply and fix in repair universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type as per sample complete all as specified and as directed.
Supply and fix in repair 0-4 step type electronic regulator for ceiling fan 1200/1400 sweep, 240 V as per sample complete all as specified and as directed.
Supply and fix in repair Switch socket combination box 2 in 1, 3 pin, 5 and 15 Amp flush type universaas per sample complete all as specified and as directed.
Supply and fix in repair Switch socket combination box 2 in 1, 3 pin, 5 flush type universaas per sample complete all as specified and as directed.
Supply and fix in repair ceiling rose surface bakelite 65x25 mm two to three terminals complete all as specified and as directed.
Supply and fix in repair lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repair 12 Watt Rechargeable/inverter type LED bulb with inbuilt lithium-ion battery of minimum 2200 mAh, suitable for automatic lighting during power failure. Bulb have B-22 bayonet Cap, cool daylight colour temperature (approx 6500k), luminous output not less than 1200 lumens and backup time minimum 3 to 4 hours. The bulb shall be suitable for 220V-240V AC operation with overcharge and surge protection upto 4KV, complete all as specified and as directed.
Supply and fix in repair of LED surface mounted Batten light 20 W 4 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. ≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). ManufacturesWord Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities forLED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab forall testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C). complete all as specified and as directed.
Supply and fix in repair of LED surface mounted Batten light 20 W 4 feet (Warm white) of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. ≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). ManufacturesWord Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities forLED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab forall testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C). complete all as specified and as directed.
Supply and fix in repair of LED surface mounted Batten light 10 W 2 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt outputt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed.
S&F in repair decorative wall-mounted light fitting, body made of die-cast aluminum with powder-coated finish and frosted/clear glass/acrylic diffuser, suitable for holding LED lamp up to 12 Watt (B22 base), IP20 or higher protection, complete with all accessories for mounting on wall surface including screws, plugs, etc. Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose/DB, complete all as specified and directed.
S&F in repair 20 watt LED Recessed/ surface Down lighter (Round/ square/Rectangular) SMD type Powder coated die cast /Extruded aluminum Body including trim with Aluminum Reflector with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed.
S&F in repair LED bulkhead light fitting, 10 Watt, white colour, housing made of high-grade flame-retardant engineering plastic with clear prismatic diffuser, suitable for wall or ceiling surface mounting. The fitting will be provided with replaceable LED lamp (cool white) and include all required mounting accessories.Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose, complete all as specified and directed.
Supplying of Panel light 2x2 ft. 36 Watt of Powder coated die cast / Extruded aluminium Body (Thickness >1.20 mm) and constructionas per IS : 10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should bebelow 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum powerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). complete all as specified and as directed.
Supply and fix in repair 36 W LED Recess mounting 4'x1' LED Luminaire having CRCA stell sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet steel frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated (RAL9016). Fixture should have minium system level >=100 Lumens/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required fo rLED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed.
Supply and fix in repair 16/18 Led Surface mounting 1'x1' LED Luminaire having CRCA sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated . Fixture should have minium system Lumens of 1800lm &minium efficacy system level >100 Limen/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required fo LED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed.
Supply and fix in repair LED Building security light fitting 35W including GI 25mm bracket in repairs of old unsv existing security light fitting any type complete all as specified and as directed.
Supply and fix in repair LED garden light (Bollard) light fitting luminiaries of 8/9 D71W in Round Shape with 1 Mtr height of 3000K with IP 65, 70 Lm/watt, PF >0.90 complte with all accessories including necessary connection with suitable of copper cable connection all as specified and directed.
Supply and fix in repair track mounting light 10W Warm White including all connection as per sample complete all as specified and as directed.
Supply and fix in repair water tight fitting (water Proof) static white ground Burried Narrow/ Medium/ Wide / Asymmetric beam cylindrical walkover Luminiare suitable for outdoor applications of facade Lightining Liminiaires should be enabled with high power LEDs should consists of highly efficient, UV and tempreture resistent optics with symmetric distribution with glass cover power consumption should be between 2.5w to 15W at stedy state full intensity Luminaire should be able to run on AC /DC Voltage Power factor of the luminiare shall be more than 0.90 Luminaire should be provided with suitable integral /seprate non integral power supply unit The luminiare should provided with suitable integral/ seperate non integral pwer suppluy unit. The lumen maintenance L70@ 25 degree celcius of the LED shall not be less than IP 67 or higher Housing should be made of Dia cast aliminium housing with 3-4mm thick safety glass all as specified and as dirceted.
Supply and fix in repair 120W Flood light fitting luminaires having pressure die cast aluminium LED housing designed to act as heat sink for efficient dissipation of heat Electrochemically brigntened and Heat resistant Toughened glass provided with gasket and SS clips Luminiare is provided for aiming adjustment Driver provided with a MS mounting bracket fixed with built in input voltage surge open and short circuit protection Finish Poeder coated FIxture should have minium system Lumen of 9600lm & minium efficacy at system level >=120 lm/w life of fixture 50K Hrs @ L70B50 Lumen maintenance CCT 570-6500K with same Lumens /W cri>70, thd <10%@ 240V AC PF 0. An operating Voltage of Range of 140-270V Surge Protection 4 Kv External Surge 10Kv IP 66, IK 07 BIS certification is required for LED Driver & Luminaire OEM should have in house NABL Accrediated R&D and own LM80 report issued by LED manufacturer complete all as specified and directed.
Supply and fix in repair 120W Highbay light having pressure die cast aluminium LED driver compartment. Eye bolt provided for suspension mounting LED fixed on die cast aluminium heat sink for proper thermal management. optics Secondary lens optics . costant current driver to have built in surge, open & short circuit protection completely prewired with accessories up to up to thermal managemen. completely prewired with accessories up to terminal block. Fixture should have minium system lumen of 13200lm & minium efficacy at system level >=110 lm/W life of fixture 50K Hrs @ L70B50 Lumen maintenance CCT 570-6500K with samE LUMENS /W cri>70, thd <10%@ 240V AC PF 0. An operating Voltage of Range of 140-270V Surge Protection 4 Kv External Surge 10Kv IP 66, IK 07 BIS certification is required for LED Driver & Luminaire OEM should have in house NABL Accrediated R&D and own LM80 report issued by LED manufacturer complete all as specified and directed.
Supply and fix in repair LED based candle light bloom white 3 w as per sample complete all as specified and as directed.
Supply and fix in repair 8/9 W LED bush/Spike luminaire having graphite grey as per sample complete all as specified and as directed.
Supply and fix in repair 40 Watt comprising of LED’s suitable for working on DALI System with suitable Dali Driver,Aluminium reflector fixed in die‐cast aluminium housing suitable for recess mounting in POP or any type of false ceiling supplied with wedge bracket to fix in New POP or any type of false ceiling including cutting / grouting of any type of false ceiling and POP ceiling to match with POP through three nos. spring loaded latches .Finish: White powder coated . Driver: Constant current LED driver. Fixture should have minimum system lumen of 4000lm & minimum efficacy at System level >=100 lumens/ watt, Life of fixture : 25K Hrs. @ L70B50 Lumen maintenance, CCT 5700-6500K with same lumens/w. CRI >80, THD <10%@ 240v ac. An operating Voltage Range of 140 - 270 V. Minimum Internal Surge Protection 2kv, IP 20. BIS certification is required for LED Driver & Luminaire, OEM should have inhouse NABL Accrediated R&D and own luminaire manufacturing facility to provide LM79 report from in house NABL accredited lab & LM80 report issued by LED manufacturer. and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed.
Supply and fix in repair of LED Circular Recess mounting LED Downlighter of 32 Watt with Powder coated spun aluminium ring. LEDs module is mounted on extruded aluminum heat sink for better thermal management. LEDs incorporated in Aluminium anodised sheet for minimizing glare. Aluminium reflector is fixed with heat sink by SS clips.. Driver: Constant current LED driver. Fixture should have minimum system lumen of 3200lm & minimum efficacy at System level >=100lumens/ watt, Life of fixture : 50K Hrs. @ L70B50 Lumen maintenance, CCT 5700K with same lumens/w. CRI >70, THD <10%@ 240v ac. An operating Voltage Range of 140 - 270 V. Minimum Internal Surge Protection 2kv, IP 20. BIS certification is required for LED Driver & Luminaire, OEM should have inhouse NABL Accrediated R&D and own luminaire manufacturing facility to provide LM79 report from in house NABL accredited lab & LM80 report issued by LED manufacturer suitable for POP or any type of false ceiling supplied with wedge bracket to fix in New POP or any type of false ceiling including cutting / grouting of any type of false ceiling to match with fitting and providing connections to the fitting complete all as specified and directed.
Supply, installing, commissionig and testing in repairs of twin universe DALI Router with Ethernet connection as a network backbone. Programmable through software, the router supports 128 devices with 250mA power supply on each subnet. Upto 100 such Router can be networked together and upto 12800 DALI devices can be networked together on a Route system. With in built Real time Clock, the product conforms to DALI standard IEC60950 and further EMC conformance to EN55015 and EN61547 and Safety confarmance to EN60950 including including complete necessary electrical connection with dimmable light fitting to DALI system for the controlling of whole lights in grouping or individually complete all as specified and as directed.
Supply, installing, commissionig and testing in repairs of custamisable wall mounted DALI compatible user interfaces allowing control of dimmable lighting system. Each interface will have tactile buttons with Indicators LEDs and with IR receiver giving optioin of remote operation using hand held remote controls. Progammable using software and designed to fit standard 3"x3" wall boxes with choice of Black & White finishes and multiple choices in outer plates. Typically choice of 2 to 8 buttons available of the including complete necessary eletrical connection with dimmable light fittings to DALI system for the controlling of whole lights in grouping or individually complete all as specified and directed.
Supply and fix in repair of LED Briteq - Belgium, BT -Theatre 100 EC MK2 of 100 Watt warm white Cob LED light fitting with Barndoors - 3200K - DMX - Neutrick powercon connectors - 10-50 Deg manual zoom with 125 power consumption suitable for stage light of Zorawar & Ashoka Auditorium including including necessary electric connections by approriate size of PVC copper wire with incoming submain and adoptor complete all as specified and directed.
Supply and fix in repair of LED Briteq - Belgium, BT -Theatre 60 FC of 60 Watt full colour RGBW theatre LED spot light fitting with manual zoom 10-50 Degree with Barndoor - DMX and RDM compatible of 62 Watt power consumption suitable for stage light of Zorawar & Ashoka Auditorium including including necessary electric connections by approriate size of PVC copper wire with incoming submain and adoptor complete all as specified and directed.
Supply and fix in repair of LED Briteq - Belgium, LDP Cobwash 50 WW of of 50 Watt warm white Cob LED light fitting with Barndoors - 3200K - DMX of 66 Watt power consumption suitable for stage light of Zorawar & Ashoka Auditorium including including necessary electric connections by approriate size of PVC copper wire with incoming submain and adoptor complete all as specified and directed.
Supply and fix in repair of Adoptor of 24 Volts for AC to DC supply suitable for 6 to 12 outgoing port to connections of step lights circuit upto 20 Amps capacity complete all as specified and directed
Supply and fix in repair in repairs of LED fibre Optic Step light 5 watt for step nosing having aluminium extrusion, antislip profile with blue LED on either one or both ends and other accessories such as control transformer , properly mounting and covering control transformer .This item shall be complete in all respects with LED light , Control transform,ers , clamps , all necessary hardwares , control transformer cover etc comprising of following (Make – Fibre Optic or equivalent in Pranat , Philips): (i) Aluminium Extrusion (ii) Anti Slip Profile (iii) Combination of LED and 5 mm fibre optic. (iv) Row numbering on one side / both side with blue LED duly installed with 1.0 metre ( end to end ) with seat and row number on both side.
Supply and fix in repair acrylic glow sign board with LED light of size 10x7 inch including all connection as per sample complete all as specified and as directed.
Supply and fix in repair of 6 W Ceiling Speaker of any type of Manekshaw centre complete all as specified and directed.
Supply and fix in repair of 9 W Ceiling light of any type or any colour complete all as specified and directed.
Supply and fix in repair of distribution board V-TPN 4 way for fixing MCCB 125 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting complete all as specified and as directed.
Supply and fix in repair MCCB 125 Amps 4 pole 415 volts fixed type with breaking capacity 16 kA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
Supply and fix in repair MCB DB SPN 8 Way double door type, (IP 43 Protection) flush mounting as per sample complete all as specified and as directed.
Supply and fix in repair MCB SP 10 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement and as directed.
Supply and fix in repair MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement and complete all as specified and as directed.
Supply and fix in repair MCB TPN 63 Amps 415 volts, 'C' Series 10 KA as per site requirement and complete all as specified and as directed.
Supply and fix in repair submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing/new PVC concealed conduit complete all as specified and as directed.
Supply and fix in repair submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing/new PVC concealed conduit complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 2.5 Sqmm in 2 runs and 2.5 Sqmm one run for earth drawing through existing/new PVC concealed conduit complete all as specified and as directed. Notes for Srl item No 83 to 85:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Supply and fix in repair PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and complete all as specified and as directed.
Supply only in repair PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and complete all as specified and as directed.
Supply only in repair PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement in Red/Blue/Yellow, Black & Green colour complete all as specified and as directed.
Supply and fix in repair PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm single core for any type of wiring as per site requirement and in Red/Blue/Yellow, Black & Green colour complete all as specified and as directed.
Supply and fix in repair Audio cable including all connection as per sample complete all as specified and as directed.
Supply and fix in repair video cable including all connection as per sample complete all as specified and as directed.
Supply and fix in repair HDMI cable including all connection as per sample complete all as specified and as directed.
Supply and fix in repair cordless mike including charging set as per sample complete all as specified and as directed.
Supply and fix in repair XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 Vots grade, crpss sectional area 16sqmm 2 core complete with lugs, joints all as specified and directed by Engr in Charge.
Supply and fix in repair Flexible copper 3 Core, 4.0 Sqmm twin core complete all as specified and as directed.
Supply and fix in repair rigid PVC conduit 25mm dia including accessories tees, bends, reducer, cooption, riddles etc complete all as specified and as directed.
Supply and fix in repair casing caping 25x16mm complete all as specified and as directed.
Taking down old unserviceable ceiling fan/exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing complete all as specified and as directed. Note : Rewinding will be measured and paid separately under this Schedule.
M&L for rewinding ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required complete all as specified and as directed. Note : Gun metal bush, clamp, shaft, capacitor, bearing will be measured under of this item only.
All as per Srl item No.97 above, but exhaust fan of 230/300/450 mm sweep.
Supply only electric BLDC fan controller PCB with short circuit protection power 440V suitable for BLDC ceiling fan of make as installed at site suitable for 1200mm sweep complete all as specified and as directed.
Supply & fixing testing and installation of 12V , 26 AH battery having 24 Months warranty sealed Lead Acid battery Model EP -26 complete with all accessories all as specified and diercted by Engr in charge.
Supply only ceiling fan capacitor of 2.5 mfd complete all as specified and as directed.
Supply only Down rod of 1.5 feet height fabricated out of MS pipe 12mm dia heavy duty, duly painted with one coat of white synthetic enamel paint complete all as specified and as directed.
Supply only Canopy of Ceiling fans of 1200/1400mm swipe heavy duty complete all as specified and as directed.
Supply only blade (set of 3 blades) of Ceiling fans 1200/1400mm swipe heavy duty as per sample complete all as specified and as directed.
Supply only blade of exhaust/fresh air fans of 230/300 mm swipe heavy duty as per sample complete all as specified and as directed.
Supply only Exhaust fan MS Louvers upto 450 mm Size, as per sample up to fourth floor complete all as specified and as directed. Note:-Staircase arrangement for fixing of louvers up to fourth floor shall be arranged by the contractor without any extra cost.
M&L in repairs Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering, all as shown in Electrical Plate No.05 of SSR-2009 (Part-I) and connected to earth test point including testing etc. complete all as specified and as directed.
Supply & fix in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
S&F in repair Occupancy switch recessed mounted in ceiling ,-20 to +70 degree celcius , relative humidity 20% to 90% no condensation , 230V , 50Hz , 6A load , 1.5 to 2.5mm, TN-S, 16A max with neutral grounded satnd by time 1.2W, Max 1.2W, Miximum wire range 1.5 to 2.5 Sqmm, Switch off delay 10 to 30 min complete all as specified and directed by Engr in Charge.
Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. Note: Old meter shall be deposited in MES yard.
Testing of existing wiring for short circuit/earth fault in the existing wiring system and removal of the short circuit/earth fault in the internal wiring of the buildings by removal of DB, MCB's, main switches etc. complete all as specified and directed.
Hiring and providing (aluminium/steel) scaffolding with suitable size to attend the complaints where the room it is more than 4.00 mtr complete all as specified and as directed. Notes :- 1. The rate quoted by the tenderer are deemed to be included for hiring, transporting (both side), assembling & dismantling of scaffolding after attending the complaint. 2. The complaint shall be measured and paid seperately under Srl item No. 1, 2 & 3 of this schedule. 3. This item shall applicable only Srl item No.1, 2 & 3 of this schedule.
Descalling of geyser 25/35 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank, themrostate pipe, base plate assembly including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and as directed.
Supply only thermostat 9/11" (ISI Marked) for 25 Litres capacity Geyser as per sample complete all as specified and as directed.
Supply only MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and as directed.
Supply only heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and as directed.
Supply only storage tank made out of SS Steel sheet of appropriate thickness and confirming to IS 208 (1974) or as per sample for 25 litre capacity geysers with collar, duly tested at required pressure complete all as specified and as directed.
Supply only safety plug and nut for high pressure release as per sample complete all as specified and as directed.
Supply only non return valves 15mm dia made up of brass as per sample complete all as specified and as directed.
Supply only indicating lamp round / flat type (Red & Green) 230 volts suitable for Geyser as per sample complete all as specified and as directed.
Supply only PVC Pipe brass nipple 15 mm x 600 mm for Hot & Cold water with brass nuts and washers stainless steel at both ends of length not exc. 60 cms for connection of stainless steel as per sample complete all as specified and as directed.
Supply only insulating material (Glass wool) for 25/35 litre capacity Geysers as per sample complete all as specified and as directed.
Supply only base plate geyser syphon assembly set complete with inlet, outlet and thermostat, complete including rubber gasket as per sample for geyser of 25 litres cap as per sample complete all as specified and as directed.
M&L for comprehensive maintenance and overhauling quarterly (every four months commencing form actual date of commencment of work ) of scissor lift platform mounted of size 1500x 1000mm capacity 250 kg stage height 1200 mm with hydrulic pump, motor suitable for to take a wheel chaired person alongwith one attendent in zorawar auditorium of manekshaw centre by performing foloowing task complete all as specified and directed- (a) Inspection of Brakes , Drive control (b) Cleaning of control panel (c) Inspection of control Panel. (d) Electrical Panel. (e) Inspection of safety indication light. (f) Inspectionn of Platform. Note- Each comprehensive maintenance shall be measured and paid as one Job.
Dismantling/disconnection of curtain motor 3 phase, 415 volt, 1.5/2 HP from platform on roof height complete over hauling/serving of electric motor for front/middle/rear curtain including replacement of bearing/brush and unserviceable SWR rope of suitable size and greasing of pullies/gears and refixing after/repair the same in auditorium complete all as specified and directed
Supply only pressure pipe suitable foe existing scissor lift(any capacity and size) matched with system/machine fitted in Manekshaw centre complete all as specified and directed.
Supply only compressor oil suitable for existing scissor lift/curtain motor (any capacity & size matched with system/machine fitted in Manekshaw centre complete all as specified and as directed.
Comprehensive Maint of Servo type voltage stabilizer oil cooled of capacity 48KV complete including disconnection of electrical connection and reconnection after maint complete all as specified and as directed. (a) Servo control panel (b) Servo Circuit card(PCB) (c) Multifunctional Meter (type 1) (d) Multifunctional Meter (type 2) (e) PCb Holder (f) Voltmeter (g) Ammeter (h) Trigger Transformer (i) Push Button/Auto Manual Switch/Micro Switch/Potentiometer/LimitSitch/Level Switch. (j) Indicator Light (k) Servo Motor with RC (L) Dimmer (M) Carbon Bush Note: Necessary parts shall be measured and paid saperately.
Comprehensive Maint of Servo type voltage stabilizer oil cooled of capacity 75Kva complete including disconnection of electrical connection and reconnection after maint complete all as specified and as directed. (a) Servo control panel (b) Servo Circuit card(PCB) (c) Multifunctional Meter (type 1) (d) Multifunctional Meter (type 2) (e) PCb Holder (f) Voltmeter (g) Ammeter (h) Trigger Transformer (i) Push Button/Auto Manual Switch/Micro Switch/Potentiometer/LimitSitch/Level Switch. (j) Indicator Light (k) Servo Motor with RC (L) Dimmer (M) Carbon Bush Note: Necessary parts shall be measured and paid saperately.
Comprehensive Maint of Servo type voltage stabilizer oil cooled of capacity 8KVA -03 Nos ) complete including disconnection of electrical connection and reconnection after maint complete all as specified and as directed. (a) Servo control panel (b) Servo Circuit card(PCB) (c) Multifunctional Meter (type 1) (d) Multifunctional Meter (type 2) (e) PCb Holder (f) Voltmeter (g) Ammeter (h) Trigger Transformer (i) Push Button/Auto Manual Switch/Micro Switch/Potentiometer/LimitSitch/Level Switch. (j) Indicator Light (k) Servo Motor with RC (L) Dimmer (M) Carbon Bush Note: Necessary parts shall be measured and paid saperately.
Supply only oil for servo Voltage stabilizers any type suitable for site all as specified and directed.
Supply only servo control Panel complete suitable for site all as specified and directed by Engr in charge
Supply only Servo control Box complete suitable for site all as specified and directed by Engr in charge.
Supply only Circuit card (PCB) complte suitable for site all as specified and directed by Engr in charge.
Supply only Voltmeter complete suitable for site all as specified and directed by Engr in chrge
Supply only Ammeter complte suitable for site all as specified and directed by Engr in charge
Supply only Trigger Tranformer (9V/18V) complete suitable for site all as specified and directed by Engr in chrge
Supply only Push Button/Auto Manual switc/Micro Switch Lever Switch complete suitable for site all as specified and directed by Engr in charge
Supply only Servo Motor with RC complete all as specified and directed by Engr in chrge
Supply only Dimmer complete suitable for site all as specifed and directde by Engr in charge
Supply and installation Continuous suspended 8ft linear LED luminaire made of extruded aluminimum with White/Black Powder Coated finish, with Lenses and UGR reflector, with reflector color Gun-metal/black. UGR<16, The luminaire having Lumen Output of 3600lm with system efficacy of ≥100lm/w & system wattage option 36W (±5%) ,Optics: asymemtric wall washer, The luminaire shall have a width of not more than 40mm(± 2mm), height 77mm (± 2mm) and length 2120mm (± 2mm). The life shall be 50K Hrs. at L70B50. Operating temperature of the luminaire shall be 0°C to +45°C and driver shall comply to the minimum electronic paramtere like THD≤ 10%, PF ≥0.9, internal surge protection of 4KV, operating voltage range of 140V - 270V having Class - I protection & serviceability of Class B. The luminaire shall be IP20 & IK02 compliance.The driver shall be of the same make as that of LED luminaire and must be EMI/EMC compliant. The LEDs used shall have CCT option of 3000K/4000K, having CRI≥80, & SDCM≤5. Luminaire manufacturer must have IN-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT". The the successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer. The LED Luminaire & it's driver both should be BIS registered. The luminaire shall be supplied with adjustable suspension wires. The manufacturer shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer all as specified and directed by Engr in charge.
M/S ADHIKARI CONSTRUCTION CO. (BID ID -3408861)
M/S HARINDER SINGH (BID ID -3407651)
S.R. Constructions (BID ID -3408482)
S K ENGINEERS AND CONTRACTOR (BID ID -3408957)
J B ELECTRICALS (BID ID -3402438)
M/S Malik Construction Corporation (BID ID -3416638)
Vee em Traders (BID ID -3409688)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .