Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAdmitted-Finance BALLIA UTTAR PRADESH | BALLIA | UTTAR PRADESH | 221701 | ₹4.0 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CHANDEL CONSTRUCTION COMPANY L1 |
|---|---|---|---|---|
| 1.00 | Construction of Sewage Treatment Plant of 0.430 MLD capacity based on Biodigester and Rootzone Technology with constructed wetland (Rootzone system), including evolving of hydraulic & structural designs & drawings, planning, testing and commissioning of treatment facility. The Sewage Treatment Plant should be capable of treating domestic raw sewage having characteristics of BOD =350 mg/litre & suspended Solids =650 mg/litre and the characteristics of treated /disposable effluent should comply with the standards as per the norms of H.P. State Pollution Control Board i.e. PH = 6.5- 9, BOD ≤ 10 mg/litre, COD ≤ 50 mg/litre, TSS ≤ 50 mg /litre, Faecal Coliform (MPN /1000 ml) <100, N - Total N ≤ 10 mg/litre, NH4 - N ≤ 5 mg/litre. The scope of work includes construction of Inlet Chamber (1 No.), Screen Chamber (2 No.), Grit Channel (2 No.),oil and grease chamber 1no.,parshall flume, Distribution Box (1 No.), Biodigester system, Aerobic Treatment system, Sludge Drying Beds, constructed wet land (Rootzone), multi media filter, chlorine contact tank with required arrangement, walk ways, , Interconnectivity pipe of STP units & Effluent Pipe for disposal of treated waste, Boundary wall with Fencing Panel around the S.T.P Yard (P&F), Steel Gate (P&F), Interconnecting Path, Railing and Access Ladder, Plant Building/Chowkidhar Room and pump house (plinth area of all buildings 80.50 sq.m.), providing and installation of Electro - Mechanic Equipment’s, Generator set of required capacity,Providing and fixing of yard lighting around STP, with in all leads and lifts at site complete in all respect as per the entire satisfaction of Engineer-in-charge (as per chapter No. vi(a), vi(b), vi (c). 3 Months of successful trial run as per the provisions of Manual on Sewerage & Sewage Treatment published by CPHEEO Manual (Latest edition). | 1 | Job | 4,04,45,326 ₹4,04,45,326 Lowest |
Tender Value
₹3.9 Cr
EMD Value
₹4.3 L
Closing Date
12 Jun 2026, 5:00 pmClosed
EE JSD POOh
EXecutive Engineer Jal Shakti Division Pooh Distt. Kinnaur hp
Construction of 0430 MLD Sewage Treatment Plant based on Biodigester, Rootzone Technology
2026_HPIPH_135497_1
KNR-EE-JSDP-2026/3025-3125
Open Tender
Civil Works
Item Rate
EE JSD Pooh
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
Yes
₹4.3 L
Yes
JSD Pooh
2 Jul 2026
2 Jun 2026
15 Jun 2026
2 Jun 2026
12 Jun 2026
2 Jun 2026
4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of Sewage Treatment Plant of 0.430 MLD capacity based on Biodigester and Rootzone Technology with constructed wetland (Rootzone system), including evolving of hydraulic & structural designs & drawings, planning, testing and commissioning of treatment facility. The Sewage Treatment Plant should be capable of treating domestic raw sewage having characteristics of BOD =350 mg/litre & suspended Solids =650 mg/litre and the characteristics of treated /disposable effluent should comply with the standards as per the norms of H.P. State Pollution Control Board i.e. PH = 6.5- 9, BOD ≤ 10 mg/litre, COD ≤ 50 mg/litre, TSS ≤ 50 mg /litre, Faecal Coliform (MPN /1000 ml) <100, N - Total N ≤ 10 mg/litre, NH4 - N ≤ 5 mg/litre. The scope of work includes construction of Inlet Chamber (1 No.), Screen Chamber (2 No.), Grit Channel (2 No.),oil and grease chamber 1no.,parshall flume, Distribution Box (1 No.), Biodigester system, Aerobic Treatment system, Sludge Drying Beds, constructed wet land (Rootzone), multi media filter, chlorine contact tank with required arrangement, walk ways, , Interconnectivity pipe of STP units & Effluent Pipe for disposal of treated waste, Boundary wall with Fencing Panel around the S.T.P Yard (P&F), Steel Gate (P&F), Interconnecting Path, Railing and Access Ladder, Plant Building/Chowkidhar Room and pump house (plinth area of all buildings 80.50 sq.m.), providing and installation of Electro - Mechanic Equipment’s, Generator set of required capacity,Providing and fixing of yard lighting around STP, with in all leads and lifts at site complete in all respect as per the entire satisfaction of Engineer-in-charge (as per chapter No. vi(a), vi(b), vi (c). 3 Months of successful trial run as per the provisions of Manual on Sewerage & Sewage Treatment published by CPHEEO Manual (Latest edition). | - | Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.96 MB
Tendernotice_2.pdf
PDF • 0.90 MB
Tendernotice_3.pdf
PDF • 1.26 MB
Tendernotice_4.pdf
PDF • 0.21 MB
Tendernotice_5.pdf
PDF • 0.83 MB
Tendernotice_6.pdf
PDF • 0.22 MB
Tendernotice_7.pdf
PDF • 0.52 MB
Tendernotice_8.pdf
PDF • 0.42 MB
Tendernotice_9.pdf
PDF • 0.37 MB
BOQ_200673.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].