Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.5 LAccepted-AOC MYOREPUR ANPARA ANPARA ANPARA SONBHADRA UTTAR PRADESH 231225 | SONBHADRA | UTTAR PRADESH | 231225 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹66.9 L+₹5.6 L (9.18%)Rejected-AOC | L2 | Rejected-AOC L2 BIDDER | |
| 3 | L3₹67.7 L+₹6.4 L (10.5%)Rejected-AOC | L3 | Rejected-AOC L3 BIDDER |
Tender Value
₹68.5 L
EMD Value
₹1.4 L
Closing Date
10 Oct 2023, 6:00 pmClosed
SUPRINTENDING ENGINEER
OFFCE OF SE OMC 4 BTPS ANPARA
UPKEEP OF SWITCHYARD AND CABLE MAINTENANCE AND CLEANING OF CABLE TRAYS GALLERIES OF BTPS ANPARA
2023_RVUNL_836862_1
05/EMD-II/BTPS/2023-24
Open Tender
Electrical Works
Fixed-rate
730 days
BTPS ANPARA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
DY CAO CFA BO BTPS ANPARA
₹1.4 L
3 Nov 2023
11 Sept 2023
12 Oct 2023
11 Sept 2023
10 Oct 2023
12 Sept 2023
Amount
PART-A1: work in this part shall include upkeep of the following areas/locations of ‘A’ TPS switchyard
(a)Upkeep of MCB control room floor & panel/board. (b)Upkeep of Battery room in switchyard (c)Upkeep of MCC room & charger room including panels. (d)Upkeep of PLCC/ Carrier room & panel. (e)Upkeep of testing lab, AE’s office, storeroom, shift engineer room, staircases & galleries of MCB. (f)Upkeep of 4 No. bathrooms/latrines. (g)Upkeep of Compressor room in switchyard. (h) Upkeep of 11 KV switchgear room, panels, operator room, store room, external veranda around 11 KV switchgear room.
PART-A2: The works against this part shall include the following jobs pertaining to ‘A’ TPS switchyard. The quantities mentioned are maximum quantity & the quantity may vary widely. These works shall be done as & when required:
Upkeep of marshalling boxes, panels/cabinets of 400/132/33 KV switchyard .
Cleaning of oil pit (lxbxh)- 7x7x3.2 m
Cleaning of oil pit (lxbxh)- 4.5x4x5 m
Cleaning of oil pit (lxbxh)- 2.5x2x1.75 m
Cleaning of latrine pit
Cleaning of roads in 132/400 KV switchyard area
Cleaning of Cable gallery of MCB of 400/132 KV system including trenches of ATPS & BTPS.
PART-A3: The work in this part shall include upkeep of the following areas/locations of ‘B’ TPS switchyard:
Cleaning of site offices, stores, toilet, compressor room, etc
PART-A4 The work in this part shall include upkeep of the online ABT monitoring system:
Cleaning of online ABT monitoring system of ATPS & BTPS.
PART-A5: The works against this part shall include the following jobs pertaining to ‘B’ TPS switchyard. The quantities mentioned are maximum quantity & the quantity may vary widely. These works shall be done as & when required:
Cleaning of all roads within the BTPS switchyard once a month
Cutting of plants more than six inches in height adjacent to BTPS switchyard
PART-A6: The work in this part shall include Removal and disposal of grass, wild plants, shrubs, etc in 400KV Anpara ‘B’TPS switchyard including ICT-3, 33KV Reactor areas: including ICT-3, 33KV Reactor areas)
Removal & Disposal of grass, wild plants, shrubs, etc as per scope of work for approx. 55,000.00 M2 of ‘B’TPS switchyard including ICT-3, 33KV Reactor areas
Removal & Disposal of grass, wild plants, shrubs, etc as per scope of work for approx. 60,000.00 M2 of 400/132KV ‘A’TPS switchyard.
PART-B: The work shall include grass cutting and its removal & disposal to the suitable location as instructed by engineer in charge within the area of ‘A’ & ‘B’ TPS switchyard
PART-B1:(400/132/33/11KV Anpara ‘A’TPS, Switchyard.)
Cutting & Disposal of grass & wild plants, shrubs in surrounding periphery area of 400/132/33 KV switchyard and corridor of unit 1 to 5 transmission lines as per scope of work for approx. 1,80,000.00 M2
Removal & disposal of cows or any animals from A&B TPS Switchyard.
PART-B2: (132KV Overhead structure of CWT-1 & 2 from 132KV switchyard to CW transformers)
Cutting & Disposal of grass, wild plants, shrubs, etc as per scope of work for approx. 10000.00 M2
PART-B3:Trimming of trees under the live conductors of ‘A’ &’B’ TPS Trimming of trees (diameter 50mm, height above 2 meters ) up to a height of 500mmwhich grow under the live conductor starting from Turbine Hall to Switchyard and up to 10 meters on either side of the gantry .Diameter of trees shall be measured at 1000 mm from the ground.
50 to 100 mm dia- 70 nos
100 to 150 mm dia-20 nos
Above 150 mm dia-10 nos
PART-B4: (132 KV cable trench including LANCO area.)
Cutting & Disposal of grass, wild plants, shrubs, etc as per scope of work for approx. 7700.00 M2
PART-B5: (Maintenance of switchyard lawn area.)
Maintenance of grass lawns including cutting if grass with lawn mower or foot drive thresher including watering and removing weed etc. (Area of Lawn=1929 m2)
PART-C
Preparation & spray of anti weed solution in 400KV 'A'TPS switchyard area. (three times in a year- 3Job)
Preparation & spray of anti weed solution in 400KV 'B'TPS switchyard area. (three times in a year- 3Job)
Preparation & spray of anti weed solution in 132KV 'A'TPS switchyard area. (three times in a year- 3Job)
Preparation & spray of anti weed solution in adjacent area of A and B TPS 400/132KV switchyard area (three times in a year- 3Job)
PART-D
Cleaning of cable trays and cable risers of Power cables & Control cables of various cable galleries, boiler areas, mill areas (excluding 0 to 15 mtr), TG floor, DFA & ESP areas (Under scope of work of EMD-II, BTPS) of unit #4 & #5of 2X500MW, BTPS, Anpara
PART-E1
Routine maintenance of various cabling works which includes salvaging, laying and end termination, straight through jointing, repairing tracing of L.T. power /control cable of different sizes and No. of cores subjected to maximum size of 25 mm2 Maintenance of existing MS perforated and ladder type trays, junction boxes, conduit and tray covers of ‘B’TPS, Anpara (Except coal handling area).
PART-E2
H.T. power cable armoured XLPE aluminium conductor of following sizes.
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 150 to 300 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
Opening of cable terminal box & disconnection of power cable
Salvaging
Connection of power cable & cleaning of terminal box
Salvaging
L.T. power cable armoured PVC aluminium conductor of following sizes.
1C x 26 to 150 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
1C x 400 to 630 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
1C x 800 to 1000 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
2C x 26 to 70 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
2C x 71 to 185 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
2C x 240 to 400 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 26 to 70 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 71 to 120 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 150 to 240 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 300 to 400 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
4C x 26 to 95 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
4C x 120 to 240 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
4C x 300 to 400 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
L.T. power cable armoured PVC copper conductor of following sizes.
1C x 26 to 150 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
1C x 400 to 630 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
1C x 800 to 1000 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
2C x 26 to 70 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
2C x 71 to 185 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
2C x 240 to 400 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 26 to 70 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 71 to 120 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 160 to 240 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
3C x 300 to 400 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
4C x 26 to 95 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
4C x 120 to 240 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
4C x 300 to 400 mm2
Salvaging
Laying
End Termination (One End of Cable)
Straight Through Joint
Repairing/ Tapping of Cable
Laying of new L.T. Power / Control cable of different sizes and nos. of cores subjected to maximum size of 25 sq. mm as per site requirement additional except existing laid cables
Laying
PART-E3
Fabrication of cable racks and other steel structure. (Rate/M.T.)
Tray Erection
Erection of G.I. /M.S. perforated & ladder type tray of different sizes. (Rate in R.M.)
Fixing of new tray cover of different sizes. (Rate in R.M.)
Erection of junction boxes off size. (Rate/No.)
Erection of conduit pipe of following size. (Rate in R.M.)
Up to 75-mm. dia.
Above 75 mm. dia.
Erection of conduit pipe under concrete/cement floors. (Rate in R.M. )
Up to 75-mm. dia.
Above 75 mm. dia.
Digging of earth for laying removal of cable having size more than 77 mm. /control & instrumentation cable and refilling same. (Rate in R.M.)
Installation of welding sockets / MCCB. / D.B. etc (Rate/No.)
Cleaning of cable trench of 2X500MW, ‘B’TPS, Anpara. (Rate in R.M.)(Expect coal handling area)
M/S THERMAL INDIA
M/S PRAKASH ENGINEERING WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .