| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹2.2 L+₹23,610 (12.3%)Accepted-Finance | 2 | Accepted-Finance L2 | |
| 3 | 3₹2.2 L+₹28,950 (15.1%)Accepted-Finance | 3 | Accepted-Finance L3 |
Tender Value
₹2.4 L
Closing Date
24 Nov 2021, 12:00 pmClosed
Executive Engineer
O/o The Executive Engineer, Construction Division, APWD, Campbell Bay
Supplying, installation, testing and commissioning of Air Conditioners at PS Campbell Bay and SDPO Campbell Bay Office. Re-call
2021_APWD_4303_1
51/EE/CD/CB/2021-22
Open Tender
Electrical Works
Item Rate
60 days
CD, APWD, Campbell Bay
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
30 Nov 2021
16 Nov 2021
25 Nov 2021
16 Nov 2021
24 Nov 2021
16 Nov 2021
16 Nov 2021 - 22 Nov 2021
Amount
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a)4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a)6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a)63 A
SITC of minimum 02 Ton 5 star(As per 2018 BEE star rating) Inverter High wall split type Air Conditioner (Twin/ dual rotary commpressor 1 phase 220 Volt) Make : BLUESTAR, Model IC524DATU or equivalent with minimum cooling capacity ranging from 2000 Watts to 7000 Watts (Condenser coil must be of copper material.) i/c cutting, drilling holes on the wall for passing gas pipes , fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish, wrapping PVC non adhessive white tape over insulation of gas pipe,fixing the outdoor unit on brackets etc as required and as per the direction of E-in-C.
Supplying and fixing of 4KVA Voltage Stabilizer Suitable for 2 ton Air Conditioner as required of Make V Guard Model VND 500 (Voltage Range 150V-285V,15Amps.) or equivalent.
M/s G K Construction
C. KUMAR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .