GE Utility Electric Supply
GE Utility Electric Supply Delhi Cantt
REPAIR AND MAINT OF BUS BAR PANEL LT PANEL ACBS MCCBS AND CONNECTED ITEMS AT TIGRIS TEA POINT CIRCLE ENGR MESS ARTY MESS OLD LOCATION 61 CAVALRY CMP UNIT 972 TPT COY 333 FD REGT GUN SHED MECH CAMP SIGNAL COY HB STADIUM
2026_MES_794330_1
GE ELECT/TOKEN-48/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Utility Electric Supply
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE Utility Electric Supply
₹96,000
16 Oct 2026
16 Oct 2026
9 Nov 2026
16 Oct 2026
6 Nov 2026
30 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/LT panel boards etc and supply and fixing new cold rolled medium weight mild steel hinges and door handles in position as per existing requirement with necessary spot welding, screwing etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by Engr in Charge. | 15 | Each Job | - | - |
| - | Material & Labour for replacement of existing unserviceable/damaged part/portion of the existing feeder pillar box/ panel boards with supply and fixing new part or portion fabricated out of 2 mm thick MS sheet in position including making necessary adjustments and alignments to make the existing feeder pillar box/panel board body to required shape and size(s) complete all as specified and directed by Engr in Charge.
Note :- (a) The panel board repaired shall be made totally enclosed, weather proof for installing incoming/out going MCCB/switch fuses/ cable etc. complete all as directed.
(b) The work is required to be executed in patch works and the rates quoted by the contractor are deemed to be with and including necessary cutting, welding, leveling, jointing and providing gasket for weather proof etc. as directed to match & accommodate with the existing feeder pillar box / panel board enclosures.
(c) The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer with necessary filler coating. | 20 | Sqm | - | - |
| - | Disconnecting and taking out old existing unserviceable voltmeter of any description and in any position and supply, fixing, connecting, testing and commissioning of 3 phase digital electronic voltmeter class I, any range matching with in built selector switch, suitable for LT 415 Volts 50 Hz AC supply, flush pattern, square type, with adopter complete all as specified and directed by Engr in Charge. | 8 | Each | - | - |
| - | Disconnecting and taking out old existing unserviceable Ammeter of any description and in any position and supply, fixing, connecting, testing and commissioning of 3 phase digital electronic Ammeter class I, any range suitable for matching with existing CT ratio and in built selector switch suitable for LT 415 Volts 50Hz AC supply flush pattern, square type, 96mm x 96 mm with adopter complete all as specified and directed by Engr in Charge. | 8 | Each | - | - |
| - | Disconnecting and taking out old existing unserviceable Phase indication lamps and supply, fixing, connecting and, testing of LED type Phase indication lamp with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using suitable size copper cables wires and lugs complete all as specified and directed by Engr in Charge. | 12 | set of three | - | - |
| - | M & L for preparation of old steel surfaces of steel/LT panel boards/feeder pillar boxes of any description & any position including removing disintegrated/detoriating part of paint and applying filler coat to obtain smooth surfaces and applying a coat of synthetic enamel paint using spray machine to obtain smooth finish complete all as specified and directed by Engr in Charge. | 90 | Sqm | - | - |
| - | Supply & fixing MCCB 415V AC, 4 pole should have reverse load and line termination, For 32-100 A:Should have breaking capacity of min.16 KA with thermal release adjustable from 80 to 100% & fixed magnetic release with Ics=Icu=100%
For 100-160 A:Should have breaking capacity of min.25 KA with thermal release adjustable from 80 to 100% & fixed magnetic release with Ics=Icu=100%
For 200-315 A:should have breaking capacity of min.25 KA with thermal release adjustable from 80 to 100 % and magnetic release adjustable from 5 to 10 In with Ics=Icu=100% . For 400-630 A:should have breaking capacity of 36 KA and thermal release adjustable from 80 to 100% and magnetic release adjustable from 5 to 10 In with Ics=Icu=100% with adjustable overload and adjustable short circuit protection in existing LT panel/provn of fixing arrangements by cutting and drilling busbar to exact size/provision of copper leads of suitable size at site to fix MCCB in existing panel including provision of thimbles and nut bolts of proper size and having following cap:- | - | - | - | - |
| - | (a) MCCB 630 Amp 4 pole. | 10 | Each | - | - |
| - | (b) MCCB 400 Amp 4 pole. | 15 | Each | - | - |
| - | (c) MCCB 250 Amp 4 pole. | 10 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TD48.pdf
Tender Documents • 0.75 MB
BOQ_890876.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .