Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹20.8 L+₹1.2 L (6.15%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹21.8 L+₹2.2 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹24.5 L+₹4.9 L (25.0%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹29.7 L+₹10.1 L (51.8%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Sept 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/ REPLACEMENT OF OLD UNSERVICEABLE WIRING AND ELECTRICAL APPLIANCES AT SHANKAR VIHAR (P AND H TYPE) UNDER AGE E/M (S) OF GE (SOUTH) DELHI CANTT 10
2020_MES_367488_1
GE/DS-26/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹60,000
Yes
22 Oct 2020
7 Aug 2020
7 Sept 2020
7 Aug 2020
4 Sept 2020
21 Aug 2020
8 Aug 2020 - 19 Aug 2020
Amount
Taking down carefully the old u/s Aluminium/ Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, call bell etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engr-in-Charge.
M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including existing concealed PVC conduit medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet (ISI Marked) of required color with screwed and cup washer with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete for One light /fan/Bell point controlled by one way switch all as specified and directed by Engr-in-Charge Note:- New conduit of suitable size with connected fittings will be laid, if there is damage/ blockage in existing conduit and the rates are inclusive of quoted rates and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash/white wash.
All same as per item No 2 above but here-in-before One 3 pin socket outlet, 5/6 Amps, independent board.
All same as per item No 2 above but here-in-before 5 Amp socket outlet on same board.
All as Item No 2 above but here-in-before for one socket outlet 5/15 Amps on Independent board with cables 2.5 Sqmm size for phase and neutral and 2.5 Sqmm for earthing complete all as specified and directed by Engr-in-charge.
All as Item No 2 above but here-in-before for one socket outlet 5/15 Amps on Independent board with cables 4.0 sqmm size for phase and neutral and 4 Sqmm for earthing including sheet metal enclosure point for AC complete all as specified and directed by Engr-in-charge.
All as Item No 2 above but here-in-before for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing with through existing concealed PVC/MS conduit complete all as specified and directed by Engr-in-charge.
S&F switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engr-in-charge.
S&F switch piano flush type 5/6 Amps SP two way complete all as specified and directed by Engr-in-charge.
S&F bell push, flush type 5/6 Amps complete all as specified and directed by Engr-in-charge.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engr-in-charge.
S&F switch piano type 15/16 Amps SP one way complete all as specified and directed by Engr-in-charge.
S&F universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engr-in-charge.
S&F 4 step Socket type electronic regulators for ceiling fan 1200mm sweep, 240V complete all as specified and directed by Engr-in-charge.
S&F lamp holder Angle/Batten Type bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Engr-in-charge.
S&F electric bell (Buzzer) any type complete with including fliexble wire in complete all as specified and directed by Engr-in-charge.
S&F Electric bell ding dong any type complete with including fliexble wire in complete all as specified and directed by Engr-in-charge.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement of plug top 5/16 Amps for AC's etc complete all as specified and directed by Engr-in-charge.
S&F wal mounted LED Integrated batten T5 20Watt -4ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 36/40Watt FTL fitting any type, complete all as specified and directed by Engr-in-charge.
S&F wal mounted LED Integrated batten T5 10Watt -2ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 18/14 watt FTL fitting any type, complete all as specified and directed by Engr-in-charge.
S&F in replacement of Surface mounting Round/ Square shaped LED downlighter 6 Watt any type complete with including new fliexble wire as required on site complete all as specified and directed by Engr-in-charge.
S&F in replacement LED 10 watt white Bulk head fitting any type including new fliexble wire as required on site complete all as specified and directed by Engr-in-charge.
S&F in replacement of LED Building security light fitting 30 Watts and including bracket upto of size 50mm bore GI pipe light grade with suitable size of clamps, anchor, bolts, nuts and washers etc as per site requirement complete all as specified and directed by Engr-in-charge.
S&F in replacement of VTPN distribution board 4 way double door, vertical type for fixing MCCB up to 250 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as specified and directed by Engr-in-charge. Make :Legrand Cat No. 5077 47 or equivalent in L&T/Havells/Indoasian/ Siemens
S&F in replacement of VTPN distribution board 8 way double door, vertical type for fixing MCCB up to 250 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as specified and directed by Engr-in-charge. (Make :Legrand Cat No. 5077 47 or equivalent in L&T/Havells/ Indoasian/Siemens
S&F in replacement of MCCB 4 Pole 415V, 'C' series 160 Amps with breaking capacity 36 KA including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engr-in-charge.
S&F in replacement MCB TPN 4 Pole 100 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engr-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs, MCBs to be used SPN-2 Way, 240V without busbar complete all as specified and directed by Engr-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs, MCBs to be used SPN-8 Way, 240V with 200 Amp rated busbar complete all as specified and directed by Engr-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs, MCBs to be used SPN-12 Way, 240V with 200 Amp rated busbar complete all as specified and directed by Engr-in-charge.
S&F in replacement of MCB SPN 63 Amps 240 volts, 'C' Series 10 KA including new lugs & thimbles of required size complete all as specified and directed by Engr-in-charge.
S&F in replacement MCB SPN 40 AMPs C curve complete all as specified and directed by Engr-in-charge.
S&F in replacement MCB SP 6 to 32 AMPs C curve complete all as specified and directed by Engr-in-charge.
Taking down unserviceable sub main wiring twin core any size complete and making good the disturbed surface complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring PVC insulated FRLS single core multistranded copper conductor cable 2 Runs of 10 Sqmm for phase and neutral and 1 run of 10 Sqmm for earth wire drawn through existing concealed steel /PVC conduit wiring in wall not less than 25mm dia with all fittings like tees, bends, junction/terminal boxes etc as per site requirement complete all as specified and directed by Engr-in-charge Make:- Havells/Ploycab/Finolex (Note: Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. New conduit of suitable size with connected fittings will be laid, if there is damage/ blockage in existing conduit and the rates are inclusive of quoted rates and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash/white wash)
Taking down of ceiling fan/ exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation with required cable and testing complete all as specified and directed by Engr-in-charge. Note:- Rewinding will be measured and paid under respective item of this Schedule.
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush and Shaft where ever required complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Exhaust Fan upto 450 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush & shaft where ever required complete all as specified and directed by Engr-in-charge.
S&F in replacement ceiling fan/ Exhaust fan Ball bearing of suitable size & model (as per sample) complete all as specified and directed by Engr-in-charge. Make:- NBC/ SKF
S&F in replacement for fan condenser 2.5 Mfd complete all as specified and directed by Engr-in-charge. Make :- Epcos/Tibcon/Havells
S&F in replacement for fan condenser 3.15 Mfd complete all as specified and directed by Engr-in-charge. Make :- Epcos/Tibcon/Havells
M&L for painting of ceiling fans after cleaning all dust there after applying one coat of synthetic enamel white paint first quality by using mechnical spray including filling cavities with filler and marking of MES No. as per existing complete all as specified and directed by Engr-in-charge
M&L for replacement of exhaust fan blades for size upto 450 mm sweep as per sample complete all as specified and directed by Engr-in-charge.
M&L for replacement of MS louvers suitable for exhaust fan of sizeupto 450 mm sweep as per sample complete all as specified and directed by Engr-in-charge.
M& L for replacement of Ceiling fan blades (Set of 03) heavy duty suitable for 1200mm / 1400 mm sweep complete all as specified and directed by Engr-in-charge.
S&F PVC canopy for ceiling fan of size 1200/1400 mm as per sample complete all as specified and directed by Engr-in-charge.
Taking down geyser 25/35/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and directed by Engr-in-charge.
S&F in replacement for heating element 1.5 KW of geyser 25/35 litres capacity as per sample complete all as specified and directed by Engr-in-charge. Make Micronking/Theeta/Standard
S&F in replacement for heating element 2 KW of geyser 50 litres capacity as per sample complete all as specified and directed by Engr-in-charge. Make Micronking/Theeta/Standard
S&F in replacement thermostat ( 11 inch Long) for 25/35/50 ltrs capacity geysers complete all as specified and directed by Engr-in-charge. Make:- Micronking/Theeta/ Standard
S&F in replacement for indicating lamp round / flat type as required for geyser 25/35/ 50 litres capacity as per sample complete all as specified and directed by Engr-in-charge.
S&F in replacement safety valve ISI marked for geyser 25/35/50 litres capacity as per sample complete all as specified and directed by Engr-in-charge.
S&F in replacement safety plug for geyser 25/35/50 litres capacity complete all as specified and directed by Engr-in-charge.
S&F in replacement CP connection 15mm dia 450 mm long complete with 2 Nos brass/CP nuts and washers etc for geyser 25/35/50 ltrs capacity as per sample complete all as specified and directed by Engr-in-charge.
S&F in replacement PVC connection with brass nipple 15 mm dia 450 mm long for geyser 25/35/50 ltrs capacity as per sample complete all as specified and directed by Engr-in-charge.
S&F in replacement base plate syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket of geyser 25 litres capacity as per sample complete all as specified and directed by Engr-in-charge.
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket of geyser 35/50 litres capacity as per sample complete all as specified and directed by Engr-in-charge.
S&F in replacement of inner stainless tank suitable for 25 Ltr storage water heater complete all as specified and directed by Engr-in-charge.
S&F in replacement of inner stainless tank suitable for 35 / 50 Ltr storage water heater complete all as specified and directed by Engr-in-charge.
S&F in replacement of FR PVC insulated copper conductor cable 1100V confirming to IS: 694 of size 2.5 Sqmm 3 core for connecting Gyser complete all as specified and directed by Engr-in-Charge.
M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser 25/35/50 ltrs capacity of any make and make the shell water tight including testing complete all as specified and directed by Engr-in-charge. Note:-Taking down, de-scaling, replacement of rubber gasket will be measured and paid seperatly.
S&F in replacement of Rubber gasket for Water heater storage tank of any capacity as per the existing, complete all as specified and directed by Engr-in-charge.
S&F in repair for outer body suitable for 25 Ltrs Water storage heater made of MS Sheet complete as per site requirement complete all as specified and directed by Engr-in-charge.
S&F in repair for outer body suitable for 35/50 Ltrs Water storage heater made of MS Sheet complete as per site requirement complete all as specified and directed by Engr-in-charge.
S&F in repair for Top & Bottom cover body suitabel for 25 Ltrs Water storage heater made of MS Sheet as per site requirement complete all as specified and directed by Engr-in-charge.
S&F in repair for Top & Bottom cover body suitable for 35/50 Ltrs Water storage heater made of MS Sheet as per site requirement complete all as specified and directed by Engr-in-charge.
S&F in replacement MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and directed by Engr-in-charge.
S&F in replacement of Metal Clad Socket 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or blue cap colour complete all as specified and directed by Engr-in-charge. Make - Legrand / Havell's / C&S
S&F in replacement of Metal Clad Plug Top 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or Grey colour complete all as specified and directed by Engr-in-charge. Make - Legrand / Havell's / C&S
S&F in replacement Sheet metal plug & socket encosure with MCB SP 20Amps, 240 V complete all as specified and directed by Engr-in-charge. Make - Legrand / Havell's / C&S
M&L for sub main wiring PVC insulated FRLS single core multistranded copper conductor cable 2 Runs of 6 Sqmm for phase and neutral and 1 run of 6 Sqmm for earth wire drawn through existing concealed steel /PVC conduit wiring in wall not less than 25mm dia with all fittings like tees, bends, junction/terminal boxes etc as per site requirement complete all as specified and directed by Engr-in-charge Make:- Havells/Ploycab/Finolex (Note: Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. New conduit of suitable size with connected fittings will be laid, if there is damage/ blockage in existing conduit and the rates are inclusive of quoted rates and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash/white wash)
S&F in replacement MCCB TPN 125 Amps breaking capacity 36KA, 415 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc complete all as specified and directed by Engr-in-charge. Make - Legrand / Havell's / C&S
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
aggarwal engineers contractors
M/s KUNDU CONSTRUCTION
Microsys Controls India
Surjit and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .