| Sl No | Description | Qty | Unit | Sumit Gupta L2 | NEW HI TECH WORKS L3 | FALCON ENGINEERING PROJECTS PRIVATE LIMITED L3 | KAPAHI CONTRACTS PRIVATE LIMITED L4 | M/S CONSTRUCTION ENGINEERS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m | ||||||||
| 1.10 | All kinds of soil. | 6,676.07 | cum | 133 ₹8.9 L | 150 ₹10.0 L | 200 ₹13.4 L | 200 ₹13.4 L | 180 ₹12.0 L |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m | 4,005.64 | Cum | 133 ₹5.3 L | 131 ₹5.2 L | 115 ₹4.6 L | 150 ₹6.0 L | 100 ₹4.0 L |
| 3.00Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : | ||||||||
| 3.10 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) | 998.01 | cum | 3,333 ₹33.3 L | 3,950 ₹39.4 L | 3,000 ₹29.9 L | 2,919 ₹29.1 L | 3,000 ₹29.9 L |
| 3.20 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | 533.14 | cum | 3,933 ₹21.0 L | 4,250 ₹22.7 L | 4,100 ₹21.9 L | 3,500 ₹18.7 L | 4,000 ₹21.3 L |
| 4.00Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. | ||||||||
| 4.10 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 8.85 | cum | 9,333 ₹82,597.05 | 6,200 ₹54,870 | 7,000 ₹61,950 | 5,919 ₹52,383.15 | 7,000 ₹61,950 |
| 4.20 | 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size) | 561.68 | cum | 3,333 ₹18.7 L | 2,000 ₹11.2 L | 3,000 ₹16.9 L | 2,500 ₹14.0 L | 3,000 ₹16.9 L |
| 5.00 | Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projection. | 19,364.18 | meter | 3.33 ₹64,482.72 | 1.5 ₹29,046.27 | 30 ₹5.8 L | 19 ₹3.7 L | 10 ₹1.9 L |
Tender Value
₹23.8 Cr
EMD Value
₹47.7 L
Closing Date
15 Jan 2026, 4:00 pmClosed
Estates Officer, SKUAST-Jammu
Estates Division SKUAST-J Chatha
Construction of Faculty of Horticulture alongwith associated sanitary fittings and internal electrification at Main Campus Chatha, SKUAST-Jammu
2025_SKUST_299070_2
AU/Estates/2025-26/22 dated 19-12-2025
Open Tender
Civil Works
720 days
Main Campus, Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹3,000
Assistant Comptroller (Estates), SKUAST-Jammu
₹47.7 L
23 Jan 2026
24 Dec 2025
16 Jan 2026
26 Dec 2025
15 Jan 2026
26 Dec 2025
Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level :
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size)
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projection.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, walls, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Shelves (Cast in situ)
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Columns, Pillars, Piers, Abutments, Posts and Struts.
Suspended floors, roofs, landings, balconies and access platform.
Stairs (excluding landings) except spiral staircases.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
Cold twisted/TMT bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1: 6 (1 cement: 6 coarse sand)
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :
Cement mortar 1: 4 (1 cement: 4 coarse sand)
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer,
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Hot finished welded type tubes
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles ISI marked (powder coated) with necessary screws etc. complete :
Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles (Size 600x600 mm) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:3 (1cement :3 coarse sand) including grouting the joints with white cement and matching pigments etc. complete
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.
Size of tile 600x600 mm
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge.
With average thickness of 120mm and minimum thickness at khurra as 65 mm
Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design
In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
12 mm cement plaster of mix : (Inside)
1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix :
1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix :
1:3 (1 cement: 3 fine sand)
Washed stone grit plaster on exterior walls of height upto 10 m above ground level in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2kg of cement per m2, top layer 15mm cement plaster 1:1/2 :2 (1 cement: 1/2 coarse sand : 2 stone chippings 10mm nominal size), in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer-in -charge (payment for providing grooves shall be made separately).
Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :
15 mm wide and 15 mm deep groove
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Finishing walls with Acrylic exterior paint of required shade : :
New work (Two or more coat and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Providing and laying RBM (River Bed Material) including loading, carrying, unloading, spreading, compacting and watering complete item.
Providing and injecting chemical emulsion for pre/post constructional Anti-termite treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor,along the external perimeter of building,expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipe and conduits with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to 1% concentration, labour, HOM of equipments, complete as per specifications.(plinth area of building at ground floor only shall be measured).
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular tank
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete
Inside size
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (medium duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing following PVC pipes alongwith necessary assesories and fitting (such as tee, elbow, bends etc )complete items
PVC pipe (150 mm nominal dia)
PVC pipe (100 mm nominal dia)
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing viterous china wash basin (counter type) of approved make, size and colour, with 32 mm C.P. brass waste of standard pattern, including fittings and brackets, fasteners etc. complete in all respects as per the directions of Engineer in Charge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required
Kitchen sink without drain board
610x460mm bowl depth 200mm
Providing and fixing C.P. brass mixer /pillar cock of approved quality and make
15 mm nominal bore.
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 893
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing C.P. soap dish
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
32 mm dia
Providing and fixing 100 mm CP grating.
Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour
15 mm nominal bore with 30 cm length.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15 mm nominal bore.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
15 mm dia. nominal bore
20 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c trenching and refilling.
25 mm dia. nominal bore
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manholes 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m
with common burnt clay F.P.S. (non modular) brikcs of class designation
Providing M.S. foot rests including fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
With 20 mm diameter round bar
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
Providing and laying Plain Cement Concrete (PCC) of M10 grade (1 cement:3 coarse sand:6 graded stone aggregate 40 mm mm nominal size) as pipe bedding and haunching, surrounding the RCC pipe 450 mm diameter from the bottom upto the spring level, including the cost of materials, labour, mixing, conveying, laying compacting and cuing complete.
Dewatering (Bailing out water) from foundation trenches where subsoil water is encountered, by pump set/manual means. The lumpsum rate includes the cost of all equipment, fuel power, maintenance, labour (24x7 operation), testing and final disposal of pumped water for complete construction period.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)
With float glass panes of 4.0 mm thickness
Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
Providing and fixing wire gauge in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the Architectural drawings and the directions of the Engineer in charge. (Cost of aluminium snap beading shall be paid in basic item)
Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as epr requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment)
Providing and fixing 100 mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium lock handles for aluminium sliding shutters.
Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete :
Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness.
Providing and fixing 4.0 mm thick Fibre Cement False Ceiling (tiles of size 595x595 mm) conforming to IS 14862:2000, Type B Category 3, fixed on metal grid system comprising of hot-dipped galvanized interlocking metal T-section main runners, cross tees and wall angles, suspended from ceiling with dash fasteners, hangers, GI wire etc., complete as per manufacturer’s specifications and direction of Engineer-in-Charge
Providing and fixing 8 mm thick decorative PVC wall paneling of approved design, make, and color, including all matching uPVC accessories like corner trims, edge trims, and end caps, all complete as per the direction of the Engineer-in-Charge. The rate shall be for the finished area of the wall paneling
With float glass panes of 5.00 mm thickness
Providing design, supply, and erection commissioning and testing of 150 m3/Day Sewage Water Treatment (MBBR) Plant
Providing structural drawing duly vetted by competent authority (DICQ/NIT/IIT or equivalent alongwith soil testing report) All complete work as per direction of Engineer-in-charge.
Surface preparation including cleaning of expansion joint and then installation of Hypalon strip thickness 150 mm with epoxy adhesive on both edges.
Filling of Poly-urethane sealant with backup rod.
Fixing of aluminium strips, thickness would vary according to xize (150-300 mm) of shape of joint.
Providing and laying stone soling (hard stone/rubble of specified thickness) including hand packing and thoroughly filling the interstices/voids with coarse sand/moorum/stone chips, watering and compacting including consolidation with power roller/rammers, and all operations, complete as specified and directed by the Engineer-in-Charge.
Providing and fixing the following fire fighting items:-
Butterfly valve 1"
Non return valve 1"
Branch pipe with nozzle 1"
Fire brigade connection (63 mm)
Fire rated door complete accessories and fire rated 120 m
Hase real drum and accessories
Landing valve
Coupling ((M/F)
Union 3"
Reel hose pipe
Cabinet
Socket 3"
M.S. pipe
Supplying and laying of 35 x 3.5 core aluminium armoured PVC cable
M.S. flange
ABC type fire extinguishers 6 kg
CO2 Type fire extinguisher 2 kg
5 HP motor Kirloskar/Crompton Greaves
SUB-DISTRIBUTION BOARDS
Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B)
Single Pole
40 ampTriple Pole and neutral
63 amp Triple Pole neutral
Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required
40 amps SPN
63 amps SPN
EARTHING AND LIGHTNING PROTECTION
Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection.
Providing and fixing 25 mm x 5mm GI strip from earth electrode as required
DISTRIBUTION BOARD
Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized, cubicle indoor type fabricated with 16 SWG sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/ mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specifications and drawings.
Moulded case circuit Breakers shall be thermal magnetic trip type. Fault level for all MCCB and bus bar shall be 35 KA. ICU shall be equal to ICS=100%
All metering current transformers shall be Class 1, 15 VA.
MDB-1 (Indoor Type) Power Panel
Incomer
630 A 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
630 A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
125 amm MCCB 4 pole 36 ka -10 no
250 amp MCCB 4 pole 36 ka - 2no
Outgoing
40 Amp TPN - 2 No.
63 Amp TPN - 2 No.
40 Amp SPN - 2 No.
63 Amp SPN - 2 No.
MDB-1 (Indoor Type) A C Panel
Incomer
630 A 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
630 A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
125 amm MCCB 4 pole 36 ka -10 no
250 amp MCCB 4 pole 36 ka - 2no
Outgoing
40 Amp TPN - 2 No.
63 Amp TPN - 2 No.
40 Amp SPN - 2 No.
63 Amp SPN - 2 No.
MDB-1 (Indoor Type) Light Panel
Incomer
400 A 4P MCCB – 1No.
R,Y,B phase indicating lights with control fuses - 1 set
Bus Bar
400 A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
100 amp MCCB 4 pole 25 ka -2 no
63amp MCCB 4 pole 25 ka - 2no
Outgoing
40 Amp TPN - 2 No.
63 Amp TPN - 10 No.
40 Amp SPN - 2 No.
63 Amp SPN - 2 No.
Supply and laying of PVC Power cable 1.1 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required.
3.5C x 150 sq.mm
3.5C x 300 sq.mm
SUB-DISTRIBUTION BOARDS
Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required.
8 way TPN
4 way TPN
12 way TPN
Supply and fixing 1x20 watt with extruded alulminium tube light including connection testing etc. as reqd. (CCS-103-20-65-SL-DP-NWH) or equilent in Wipro,Philips
Supply and fixing of 18 Watt LED Panel surface mounted Alum. body including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL) or equilent in Wipro,Philips
Supply and fixing of 12 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-12-CDL) or equilent in Wipro,Philips
Supply and fixing of 18 Watt LED Panel Recess mounted Alum. body including connection testing etc as reqd.
Supply and fixing of 2x2 36 watt Recess mounted LED LIGHT including connection testing etc as reqd. (LCTLRNE-36-FO-CDL) or equilent in Wipro,Philips
Supply and fixing of 9 Watt LED mirror light 2' long including connection testing etc as reqd. (CAT No. LCTL-09-CDL) or equilent in Wipro,Philips
Supply and fixing of 70 Watt LED street light with GI pipe bracket with all accessories including connection testing.
Supply and fixing of 150 watt LED Flood light IP 66 with all accessories including connection testing.
Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit(2mm thick) including modular switch, modular plate suitable box and earthing the point with 1.5 sq mm FRLS pvc insulated copper conductor single core cable etc as requried
Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of modular switch, modular plate suitable box and earthing the point earth the as required with 01 No. PVIC insulated green colour wire.
Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required
Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required
Wiring for power plug with 2 x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required
Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring )
Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings.
2x6 sq mm with 1x6.0sqmm earth wire
2x10sq. mm with 1 x 6.0sq. mm earth wire
4x16 sq. mm with 2 x 6.0sq. mm earth wire
4x4sq. mm with 2 x 4.0sq. mm earth wire
Wiring for sub main wiring with4x10 sqmm alongwith 2x6sqmm earth wire sizes of PVC/ insulated copper conductor side core conductor in surface/recessed PVC conduit etc. as reqd.
Wiring for twin control light point with 2x1.5 sq. mm PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit with 2 way 6 Amp switch
Supplying and fixing suitable GI box with modular plate and cover in front on surface or in recess, including P/F 6 pin 15/16 amp and 5/6 amp modular socket outlet and 15/16 amp modular switch , connection testing etc as requried
Supply and fixing of 250 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supply and fixing of 200 mm x 300 mm x 100 mm deep size metal box with suitable size phenolic laminated sheet cover in the front including connection testing etc as reqd.
Supply and fixing 2 module step type electrinoc fan regulator on the existing modular platye switch box including but excluding modular plate etc
Supply and fixing of 1200 mm sweep ceiling fan BLDC 5 Star rating including connection testing etc. as required.
Supply and fixing of wall fan 16" including connection testing etc. as required.
Supplying and fixing of exhaust fan 300mm sweep heavy duty trans air with double ball bearing including connection, texting etc. as required.
Supplying and fixing of exhaust fan 450 mm sweep heavy duty with double ball bearing including connection, texting etc. as required.
Supply and fixing Call bell / buzzer DC / AC single phase 230 V complete
Supply and fixing 20 Amp Industrial socket with 32 Amp SPN including connection, testing, etc. as required
Supply and fixing of 63 Ampere TPN in the existing Distribution board including connection testing etc as reqd.
Supply and fixing 2 Hp single phase monoblock pump set covered with shed of suitable size made of 16 SWG MS sheet including its painting and with small outdoor panel with bus bar 32 TPN with single phase starter including testing commissioning etc. required
Supply and fixing of 25 mm dia PVC conduit alongwith accessories in surface/recess.
Supply and fixing of 32 mm dia PVC conduit alongwith accessories in surface/recess.
Supply and fixing of 9 m SST poles in cement concrete pedestal 1:3:6 including excavation foundation (1:4:8) centering and shuttering of poles by engaging skilled labour with long rope complete job including cost of cement and carriage of pole from store to site.
Supplying and fixing of Mukki Clamp complete with nut, bolt etc. as reqd.
Supplying and fixing of U-Clamp alongwith 4" in size Shekel insulator with 6" long G.I. nut bolt complete job.
Supplying, laying, stringing and binding of LT conductor (Rabbit)
Supplying and fixing of stray rod complete with all accessories including digging of pit and refilling it with cement concrete (1:3:6) complete job including cost of cement.
Supply and Laying of 2x10 sq mm alum cable complete connection testing etc
Supply, installation, testing and commissioning of 630 KVA Capacity transformer level 2 step up/down out door type complete copper wound Ac 3 phase 4 wire 50Hz 630 KVA capacity step down out door 11000/433 volt (at no load) as per IS-1180 part-1 : 2014 (level 2) copper wound oil cooled with external cooling tubes/ fans core type. The job includes platform of size ( 6'-0''X 6'-0'') 4feet height including HT/LT line 1.2 km approx with SST pole 11 meter along with 11 KV GO/DO set, link set, LA set, earthing (4Nos) complete with Distribution Transformer box including 1000 amp MCCB 50k 4 pole 1no fuse set 630 amp- 4 set complete job
Supply and fixing of bus bar 630 amp 3 phase with MS box 3ft X 2ft approx. Size including connection testing etc aas requried
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TermsandConditionsoftheContract.pdf
Tender Documents • 0.25 MB
BOQ_969925.xls
BOQ • 2.17 MB
Facultyofhorticulturedwg.pdf
Additional Documents • 4.52 MB
Download all tender documents and submit your bid