Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-Finance Offer lowest bid therefore Provisional order issued | |
| 2 | L2₹20.5 L+₹97,350 (5.00%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹20.9 L+₹1.4 L (7.22%)Rejected-Finance | L3 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
28 Aug 2021, 1:00 pmClosed
EE KNHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
SITC of Air Conditioning system at NICU ward of Dr BC Roy PGIPS Phool Bagan Kol 54
2021_WBPWD_339787_1
WBPWD/EE/KNHED/NIQ-77/21-22
Open Tender
A/C ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹39,000
3 Sept 2021
11 Aug 2021
31 Aug 2021
13 Aug 2021
28 Aug 2021
13 Aug 2021
Amount
Supply of 8.5 TR Ductable type Split Air Conditioner of rated cooling capacity of 102000 BTU/hr. with Scroll compressor, 1 no. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 3400CFM. Refrigerant R410A ( Make: Hitachi/Daikine/O-General/Voltas) incl. sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages.
Erection ,testing,Commissioning Charges for 8.5 TR AC Machine
REFRIGERANT PIPING with Insulation Supply and installation of 20 gauge copper hard drawn Refrigerant piping complete with necessary fittings, GI bracket supports etc arrangements.(Make : Royku) with Supply & fixing of Nitrile Rubber tube insulation of 19 mm thick on copper pipe. Make Armacell / K Flex/ A Flex a) Liquid line(1 1/8")
b) Suction line (5/8')
AIR DISTRIBUTION SYSTEM Design, supply, fabrication and erection class VIII grade (120 GSM) GI sheet supply air duct along with necessary supports, flanges etc etc as required and as per IS 655 and IS 277 standards of followings gauges (Make SAIL/ TATA) a) 24 SWG thick
b) 22 SWG thick
PVC insulation flexible copper Cabling from Condensing Unit to control panel (Make: polycab/finolex/ KEI) a) 4 core 1.5 sq.mm communication cable
b) 3 core 2.5 sq.mm communication cable
AIR TERMINAL Supply ,fixing , testing & commisoning of extruded Aluminium Rectangular Grille with VCD for supply Air
Supply ,fixing , testing & commisoning extruded Aluminium Rectangular Grille without VCD for return Air
Supply , installation , testing and commissioning of opposed type GI Fresh air dampers
Supply , installation , testing and commissioning of opposed type GI Fire dampers
Supply , installation , testing and commissioning of opposed type GI volume Control dampers
Supply , installation , testing and commissioning of opposed type GI None Return dampers
CONDENSATE DRAIN PIPING Drain Water piping work out of PVC / HDPE hard pipes with Insulation, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors. a) 25 mm Dia
DUCT THERMAL INSULATION Supplying and fixing of 19 mm thick duly laminated aluminium foil of mat finish closed nitrile rubber (Class 0) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile tape insulation complete (make Armacell / K Flex/ Supreme / A Flex)
10 mm thik Acoustic insulation of duct with fire retardant, closed cell, tri-dimentional chemically crosslinked polyethylene foam insulation conforming to Class 0 fire propagation rating and having minimum density of 32 kg/cu.m. Insulation material shall be supplied with factory applied pressure sensitive adhesive and protective cover. (Make - Armacell / K Flex / Supreme)
MISCLLENEOUS Supplying, fabrication & fixing M.S U-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for installation of outdoor unit of 8.5 TR ductable incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. as per direction of EIC.
Charges for drop ceiling to cover the Indoor Units and other duct made of Aluminium Composite Panel Board
Charges for Trap Door made of Aluminium Composite Panel Board
Supply and fixing of Al powder coated continuous Grill
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
S.R. REFRIGERATION AND APPLIANCES
SOUMYA ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .