GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow -453441
SPECIAL REPAIR TO BLDG NO CB 337 AND ROOF TREATMENT IN BLDG NO CB 347 AND CB 331 IN DEMO BN AND PROVN OF PARKING SHED NEAR BLDG NO CB 348 350 351 IN DEMO BN UNDER GE MIS MHOW
2024_MES_672437_1
8687/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
180 days
GARRISON ENGINEER (MIS)
All as per Tender document
7 documents required · 7 mandatory
₹500
GE (MIS) Mhow
₹90,400
Yes
12 Dec 2024
6 Sept 2024
7 Oct 2024
6 Sept 2024
4 Oct 2024
20 Sept 2024
Amount
M&L for taking down/dismantling of existing roof treatment of any description such as old APP membrane roof treatment etc terracing including screed bed/plastering of any thickness and removing the debris outside MD land etc. and carrying out the following roof treatment complete all as specified and as per Manufacturer's instructions:- (a) Cleaning the existing roof surface and brushing with neat cement slurry @3 Kg per Sqm area complete. (b) Rendering average15mm thick in cement mortar 1:4 mixed with integral water proofing compound and finish the surface even and smooth without using extra cement complete. (c) Preparation of surfaces and applying bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete. (d) Cutting out cracks to V- section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed. (e) Applying two coats of tack coat of Industrial bitumen grade of 85/25 at the rate of 1.20 Kg per sqm including cleaning surfaces (1st coat as a bonding material below membrane and 2nd coat on top of membrane (f) APP based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as per Manufacturer's instructions complete. (9)Applying two coats of bitumen based aluminium paint @ 0.15 Kg/Sqm for each coat over APP membrane including preparation of surface complete all as specified and directed.
M&L for cement concrete 25mm thick type B-1, 1:2:4 (12.5mm graded stone aggregate) as in roof top without using extra cement etc complete all as specified and directed by Engr-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40mm brick aggregate) as in sub-base, to floor and foothpath etc complete all as specified and directed.
M&L for vitrified ceramic tiles of size 10 mm thick (light shade) (Square/rectangular) area of each tile not exceeding 0.36 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over and including 15mm screed in cement mortar 1:6 or with chemical cement to match complete all as specified and directed.
All as per item No 4.00 above but in skirting over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished and exposed visible edge moulding/rounding ) in steps, jambs, pillars, window cills, cooking platforms and like in over and including 15mm thick screed bed in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including a roughening,chipping sweeping and remove the dust after washing or cleaning of exisiting concrete surface complete all as specified and as directed by Engr-in-Charge.
M&L 20mm thick Granite (of any type)tiles mechine cut,in skitrting/dado laid over cement screed and jointed with gray cement slurry,and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 10mm thick back coat plastering of cement mortar 1:3, include a edge rounding and grooving or taking down of exisiting surface and complete all as specified and directed.
M&L for Non-skid ceramic tiles coloured, 7 to 8 mm thick (Square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, over & including 15mm thick screed bed in cement mortar (1:4) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles and including dismantling of old tiles as directed and specified.
M&L for glazed ceramic coloured tiles 450mm x 300 mm size 6 to 7mm thick in dados or skirting over & including rendering 10mm thick in cement mortar (1:4), jointed in neat grey cement slurry and pointed in white or colour cement to match the tiles including dismantling of old tiles as directed and specified.
M&L for rendering 15mm thick in cement mortar 1:4 mixed with integral water proofing compound while concrete surface is green and finish the surface even and smooth without using extra cement and including the taking down old cement plaster any description all as specified and directed. Note:- WPC shall be measured and paid separately under respective item.
M&L for rendering 10mm thick in cement mortar 1:6 on brick surface of walls finishing even & smooth without using extra cement and including taking down old cement plaster any description complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for providing and applying minimum 1.00mm to 1.50mm thick wall care putty over prepared surface to achive the surface even and smooth for painting.including complete removal of existing treatment any type of surface make surface clean,free from dust,loose pint etc complete all as specified and directed by Engr-in-Charge.
M&L for two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali and fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre /10sqm over new surface including preparation of new surfaces complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old surfaces of wall and applying two coat of oil bound distemper with roller on old treated surface of wall etc complete all as specified and directed.
M&L for preparation of old treated surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old treated steel surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old treated wood or wood based surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F 16mm outer dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including a taking down old 15mm dia pipe complete all as specified and directed.
S&F 25mm outer dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking down 25mm dia pipe complete all as specified and directed.
S&F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench and include the dismantling a old cast iron pipe and complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) bend with access door complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench and including as old cast iron pipe and complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) bend with access door complete all as specified and directed.
S&F in repairs of rotational moulded polythylene water storage tanks (double layer), 1000 Ltrs capacity, (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including providing and fixing PTMT ball valve high pressure with polythene float and fly nut, 20/25mm bore and including a dismantling of old water tank and complete all as specified and directed.
S&F in repairs of wash hand basins, vitreous china,of size 550x400mm (flat back, or angle back type) including cutting for and pinning in ends of brackets or erecting stand exclusive of fixing of supply and waste pipe etc complete all as specified and directed.
S&F in repairs of padestal pattern Vitreous china wash down water closet pan white colour, with 110mm PVC(SWR) 'P' Trap including joint run and lead front or back inlet,connection to drain (or out going pipe ) and to flushing pipe antisyphone pipe including S&F PVC cover sheet plastic water closet seat cover white closed pattern with flat bottom complete all as specified and directed.
S&F in repairs to mild steel chromium plated health fucet with 1.50m SS tube and hook all as complete specified and directed
S&F in repiars fancy chromium plated two way bib cock of 15mm bor two way bibcock screwed for iron pipe or brass feruulr etc complete all as specified and directed.
S&F in repairs 15mm bore pillar taps, cast copper alloy with capstan heads, chromium plated,fancy type screwed down high pressure with or without lettered “HOT” or “COLD” with long screwed shanks and fly nuts complete all as specified and directed.
S&F in repairs 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends complete all as specified and directed.
S&F in repairs CP Fancy type Angle cock one way, brass chromium plated, fixed to iron pipe or for unions 15mm bore complete all as specified and directed.
S&F in repairs to towel rail 600mm long 20mm dia brass chromium plated fixed with wooden guilties embedded in cement mortar (1:3) with MS screws etc, complete all as specified and directed.
S&Fin repairs of PVC valveless, syphonic action type flushing cistern,low/high level white with inlet ball valve float and handle including brackets complete fixrd in repair capacity of flush 10 ltrs (Cera/Parryware) complete all as specified and directed.
S&F in repairs to PVC waste pipe fixed to any type with coupling of not exceeding 1.50m length complete all as specified and directed.
S&F in repairs sheet glass shelf assembly, approved make, consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F PVC (SWR) multi floor trap 75mm dia meter of out let ,plain with grating including jointing with solvent cement complete all as specified and directed.
Taking down door shutter with frame exceeeding 1.50 Sqm but not exceeeding 4.00 Sqm each without taking of shutter from the frame complete all as specified and directed.
Taking down door shutter with frame not exceeeding 1.50 Sqm each without taking of shutter from the frame complete all as specified and directed.
S&F powder coated aluminium ventilator cross section conforming to IS 63.5x38.10x1.5mm consisting of two partions upper portion shall have louvers with 3mm thick pin headed glass and aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56m fixed with aluminium beads and securing on outer face of frame and lower portion of ventilation shall be fixed with 3mm thick pin headed glass with IDPE rubber gasket including aluminium beads, including preparation of jombs all around in cement mortar 1:3 finishing even and smooth complete all as specified and directed.
S&F PVC door frames of sizes 50 x 47 mm made out of 5 mm prelam PVC sheet reinforced with MS Square tube in opening of suitable size complete all as specified and directed.
S&F butt hinges 100mm extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 complete all as specified and directed.
S&F 150 mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm size aluminium anodized handle complete all as specified and directed.
S&F Factory made (Prelam on both sides) solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall covered with heat moulded prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and prelam PVC sheets for top rail, lock rail and bottom rail in either side and as gap insert for top rail and bottom rail pannelling of prelam PVC sheet to be filled in the MS welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together wiht solvent and fixing in the frame at site as per specification and drawing complete all as specified and directed.
S&F Powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters glazed and one shutter wire mesh) shall be two part as upper patr shall be three movable shutter and lower part consist three shutter (one openable in centre and both side fixed type shutter with frosted glass) with following specification and making good the adjacent side of jambs of windows by plastering in cement mortar 1:3 even and smooth complete etc . shifting of existing cooler stand where required complete all as specified and as directed by Engr-in-Charge. (i) Windows frame of cross section 101mm x 44mm x 1.5mm thick. (ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm x1.1mm thick. (iii) Sliding shutter frame of cross section 40 x 18 x 1mm thick. (iv) 4 mm thick glass superior quality. (v) IDPE Rubber guasket for fixing of glass. (vi) Locking cleats per shutter -01 Nos. (vii) Sliding rollers per shutter - 02 Nos. (viii) Stainless steel wire cloth 0.30mm nominal dia of wire and average width of aperture 1.40mm for shutters 01 Nos. (Ix) fixing screw for frame with wall per windows- 08 Nos.
S&F aluminium door ( Powder coated )frame of size 101.60 x 44.45 x 1.50 mm of approved manufacture fixed to floor, wall with real plug and screws and fixing shutter of door partly glazed and partly particle Board with frame of anodized aluminium is using with both side portion of door shutter in permanent fixing type and middle of part portion glazed and open shutter type door (including mort ice lock, hydraulic door spring ISI marked as approved) door handle tower bolt, hinges and glass pane not less than 5 mm thick fixed with rubber gasket and aluminium beading/glazing clip size 19.00 x 17.30 x 0.70mm (Weight 0.097 Kg/RM of both side) shutters with top, lock rail and vertical members of size 83.50 x 44.45 x 1.50mm and bottom members of size 114.30 x 44.45 x 1.50 mm complete all directed and as approved.
S&F framed work such as grills,grating etc with ends of bars shoulders and/or rivited/welded in guard bars and similer works confirming to FE.290,Gde-E-165 complete all as specified and directed.
M&L for painting with two coats of synthetic enamel paint to steel surfaces of any description over 10cm width or girth on untreated steel surfaces over a coat of red oxide primer after preparation of surfaces complete all as specified and directed.
Taking down shutters of any descrption exceeding 1 Sqm but not exceeding 2 Sqm each complete all as specified and directed.
S&F 35mm thick 2nd class HW glazed skeleton shutters open rebated and prepared to receive glass, gauze etc divided into squares. with sash bars (any numbers )edge of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass or gauge wire complete all as specified and directed.
S&F second class hard wood shutters 35mm thick, plain framed panelled shutter factory made (two panel) with lock rail & panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and directed.
S&F 100mm long butt hinges medium weight cold rolled mild steel complete all as specified
S&F 200 mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified.
S&F 150 mm size aluminium anodized handle complete all as specified
S&F mild steel ordinary rat tail rod pattern spring 300mm size including roller & roller plate complete all as specified and as directed
S&F aluminium floor door stoppers double legged length 140mm with hard drawn steel spring fitted in floor complete all as specified and directed.
S&F 200mm size Aluminium alloy aniodised sliding door bolt with hesp staple( bolt type) and fixing clips of sheetcast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium ally and fixed complete all as specified and directed.
M&L for brickwork with fly ash bricks,straight or curved on plan exc 6m mean radious,built in cement mortar 1:4 including demolition of old brick work at any description complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggragate) as in plinth protection and paving finishing concrete surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for providing stainless steel railing for stair case consisting of stainless steel pipes of different dia including socket,reducer,knobs balls and cups of matt finish,type and size complete all directed and approved.
S&F 25mm thick of insulated PVC wall lining consisting of PVC insulaed panels having expanded polystyrene (EPS) stuck to 2mm thick wood grain printed PVC sheet used instead of plain colour sheet duly fitted into the wall as per specification and drawing complete all as specified and directed.
M&L for chequered cement concrete tiles 40cm x 40cm x 25 to 30mm thick (Glosy finished) with grey cement and pigmentover and including 15mm thick screed in cement mortar 1:6, set jointed & pointed in neat cement slurry in floors and cut & polished complete all as specified and directed.
M&L for Non-skid ceramic tiles coloured, 7 to 8 mm thick (Square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, over & including 15mm thick screed bed in cement mortar (1:4) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles and including dismantling of old tiles as directed and specified.
S&F in repairs 110 mm bore PVC (SWR) bend complete all as specified and directed.
S&F in repairs 15 mm bib taps cast copper alloy, screwed down high pressure chromium plated screwed for iron pipe and fixed complete all as specified and directed.
S&F 25mm bore pipes steel tubing medium grade, galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in ceiling or in floors including cutting threading and making forged bends on pipes MS hooks etc including taking down old pipe in any position complete all as specified and directed.
All as per item No 71.00 above but 15mm bore complete all as specified and directed.
S&F in repairs of rotational moulded polythylene water storage tanks (double layer), 500 Ltrs capacity, (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including providing and fixing PTMT ball valve high pressure with polythene float and fly nut, 20mm bore and including a dismantling of old water tank and complete all as specified and directed.
Surface excavation not exceeding 30cm deep and avaraging 15cm deep and getting out in soft/loose complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.50m in depth for foundation etc for shaft wells cesspits,manholes,pierholes, laying of cable or pipe including trimming the sides and forming bottom surfaces to required levels not exceeding 1.50m in depth and getting out soft/Loose soil complete all as specified and directed.
M&L for PCC 1:2:4, type B-2 (using 40mm graded stone aggregate) as in embadding of fencing post complete all as specified and directed.
S&F framed brackets of angle or tees with web and flenges cut to shape,drilled and counter sunk for screw, including bending and welding angld as necessary gusset plates riviting etc N exc 10Kg each brackets,confirming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F pre-painted galvalume aluminuim zinc coating GI based corrugated steel sheet 0.50mm thick of sn colour having tensile strenght of 550Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed.
M&L for broken stone or boulder hardcore gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15mm thick, watered and rammed to true surface complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base for interlocking tiles complete all as specified and directed.
M&L for sand filling watering and consolidation spreading and levelling in layers not exceeding 25mm thick complete all specified and directed.
M&L for machine pressed precast concrete interlocking paver block using rubberised moulding any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 Grade with gray and no pigment over 30mm thick dry screened sand complete all as specified and directed.
M&L for brickwork with fly ash brick with using modular brick,straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch etc and making good to disturbed surface all as specified and directed at site.
M&L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC FRLS concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches and blank plates, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan /Exhaust Fan Point controlled by one, one way switch 5 Amps
(c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
All as per item No. 88.00 above but using 2.5 sqmm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sqmm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
All as per item No 88.00 above but using 4.0 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for geyser point/AC point connecting to metal plug and socket DB incl necessary running of 4.0 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC point)
S&F modular Switch , single pole, one way, and 5/6 Amp single module complete all as specified and directed
S&F modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module complete all as specified and directed
S&F modular Switch , single pole, one way, and 15/16 Amp single module complete all as specified and directed
S&F modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module complete all as specified and directed
S&F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S&F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed
S&F in repairs integrated LED tube light fitting 1x18/20 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square boxes including taking down the existing complete all as specified and directed. Make:- Havells Cat No. LHEXBLP7PN1W018 / Bajaj cat Pt No. BCLSB 18WH or equivalent in Wipro/Philips as approved by GE.
S&F in repairs LED light fitting 2 feet 10 watts, 6500K batten aluminium extruded with end caps complete all as specified and as directed. Make:- Cat No LHEXACP7IN1W010 of Havells or equivalent make in Wipro/Philips as approved by GE.
S&F in repairs energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe 40 mm dia medium grade bracket 1.50m long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make:- Cat No ENXT P 36L WH CR PC SD of Bajaj or equivalent make in Philips/Wipro/Havells as approved by GE.
M&L for sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq. mm nominal area and drawing into suitable size of PVC FRLSH non metallic rigid heavy duty conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 6 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of 6 Sqmm cable, two runs of 6 Sqmm cable for earth and one run of PVC conduit will be measured as one unit
S&F flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08, with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for TP/FP 100-125 amps G Frame MCCB as incomer and SP/TP MCBs as out going 8 way complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system, IP 43, IK 09 protection including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed.
S&F in repairs MCCB 4 pole, 415 volts, in the existing panel / location and connection with using aluminum lugs complete all as specified and directed for 125 Amps Adjustable type with breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB TPN 40 to 100 amps 10 KA, c-series including connection with suitable size aluminium/copper lugs complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB TP 25 to 63 amps 10 KA, c-series including connection with suitable size aluminium/copper lugs complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge.
S&F metal clad box suitable for 230 volt 50 Hz for AC connection three pin and socket with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed.
Labour only for refixing the celing fan/ Wall fan/ Exhaust fan obtained from item No 2 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250 mm including cutting of wall and duly connection with copper wire from ceiling rose etc complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cmx 6mm thick, buried directly in ground (earth pit not lessthan 2.25 m deep below ground level) with top edge of the plate otless'than 1.5 m below normal ground level, connected togalvanised earth lead wire 4.0mm dia by means of bolts, nuts, checknuts and washers of galvanised iron steel all as shown in electricalplate No. 3 connected to earthing testpoint all as specified or indicated including testing on completion complete all as specified and directed. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.50 m from earth plate is deemed to be included in rate quoted.
Taking down existing old existing unserviceable LT UG/ service cable of any description and size complete all as specified and directed.
Returning, filling in trenches in soft/loose soil in layers not exceeding 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding1.50 m high from the starting point complete all as specified and directed.
M&L for local sand cushioning with dry and clean sand over and under the under ground cable in trenches , ducts for cable protection complete all as specified and directed. Note:- Punned thickness will measured.
M&L for bricks slightly over burnt (kiln burnt) , modular bricks , best quality, locally available , laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection complete all as specified and directed.
Supply laying and jointing GI pipe 'light grade' 50 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed.
Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size 3.5 core x 35 Sqmm complete all as specified and directed
M/s Himgiri construction (BID ID -3116808)
M/S Sunshine Construction (BID ID -3116965)
Goyal Construction (BID ID -3128537)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .