Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹44.5 L+₹8.5 L (23.8%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹44.6 L+₹8.7 L (24.2%)Rejected-Finance 02 SIDDHANT RESIDENCY NEAR AMBAD POLICE STATION SINHASTHA NAGAR CIDCO NASHIK MAHARASHTRA 422009 UDYAM MH 23 0069304 | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹44.7 L+₹8.8 L (24.4%)Rejected-Finance PI NO 13 S NO 81 82 BEHIND 132 33 KVA MSEB SUBSTATION MIDC AREA AMBAD NASHIK 422 010 | NASHIK | NASHIK | MAHARASHTRA | 422010 | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹47.8 L+₹11.8 L (32.8%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
WORK SERVICES FOR PROVN OF CERTAIN E M WORK FOR EXTENDING STAND BY POWER SUPPLY VARIOUS LOCATIONS AND PROVN OF THREE PHASE STABILISED AND STAND BY SUPPLY TO UPS NETWORK NODE AT AIRFORCE STATION OJHAR
2022_MES_526117_1
8873/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹60,000
Yes
12 Aug 2022
24 May 2022
22 Jun 2022
25 May 2022
20 Jun 2022
8 Jun 2022
60 days
Amount
Shifting of D G set 250 KVA ( Floor mounted ) from one place to another place (Distance not less1.0 KM) entire area of Technical area at 11 BRD. Note : The rate of T&P (Crane and other eqpt as reqd at site for shifting and loading/unloading are also included in the quoted rates.
M & L for cement concrete 1:3:6 Type C2 using 40 mm graded stone aggregate as foundation/plinth of 250 KVA DG Set and including all necessary form work , finishing the surface even and smooth without using extra cement .complete all as specified and as directed by Engineer-In-Charge for 250 KVA DG Set
Dismantling of existing LT Panel and Shifting of LT Panel from one place to another place ( Distance not less than 1.0 KM) entire area of Technical area at 11 BRD. Note : The rate of T&P (Crane and other eqpt as reqd at site for shifting and loading/unloading are also included in the quoted rates.
Fixing only old serviceable LT panel by obtained from items no-3 above and connecting all electrical connection as reqd at site including all earth work and PCC foundation work complete all as specified and as directed by Engr - in- charge.
Shifting of D G set 82.50 KVA Trolly mounted ) from one place to another place entire area of Technical area at 11 BRD. Note : The rate of T&P as reqd at site for shifting are also included in the quoted rates.
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable with aluminium conductor 1100V grade 3.5 core cross sectional area 240 sqmm all as spfd and directed laid in trench or passing through pipe.
All as per item No 6 above but 3 1/2 core 120 Sqmm
All as per item No 6 above but 3 1/2 core 95 Sqmm
All as per item No 6 above but 3 1/2 core 50 Sqmm
All as per item No 6 here-in-before above but 3 1/2 core 25 Sqmm
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. of size 38 mm inner dia
All as per item No 14 above but 75mm inner dia
Supply and fix 80mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
M&L for Boring of holes under Road, Pavements, Hard Standing by trench less technology at a depth 0.6 Mtr from top surface including supply & fix HDPE pipe of 80 mm dia suitable for 0.4 MPA working pressure complete all as specified and directed by Engineer-in- Charge.
S &F Change over switch in sheet metal enclosure with front handle 415 Volts 4 pole 3 Ph,63 Amp- 1 nos. Make L&T cat Pt CO10630OSOO or equivalent in Legrand/Havells
M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run on wall /floor on surface in PVC cassing and capping of suitable size as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
All as per item no 19 but for One 5amps switch socket point independent.
Supply & fix Ceiling rose surface type, PVC/ Polycarbonate isolated body size 50 x28 mm two or three terminals. Make : Anchor/Haveiis Rio, complete all as specified & as directed by Engineer-in-Charge.
Supply & Fix Socket outlet 6 Amps 2/3 pin combined 2 module Make : Anchor/ Roma/ Legrand, complete all as specified & as directed by Engineer-in-Charge.
Supply & fix Modular switch one way 6 Amp,1 Module , Make Anchor/ Legrand/ Crabetree, complete all as specified & as directed by Engineer-in-Charge.
Supply and fix in repair LED Tube light decorative ultra slim square profile linear Laser Ray lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 20W LED 6000K, complete all as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No. CCS-103-20--65-SL-DP-NWH or equivalent in Havells./Bajaj.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar , 4 way ,240 volts IP 43 glazed door. Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB SPN 6 to 32 Amps 240 volts 10 KA. Make- Legrand Cat. Nos 408617 Or equivalent Make :Siemens/ L&T,complete all as specified & as directed by Engineer-In-Charge
Supply and fix MCB SP 6 to 32 Amps 240 volts 10 KA C series. Make- Legrand Cat. Nos 408595 Or equivalent Make :Siemens/ L&T,complete all as specified & as directed by Engineer-In-Charge
S&F PVC insulated and weather proof 4 core copper conductor cable 16 sq mm multi stranded fixing on wall/floor with suitable size of clamp etc complete all as specified & as directed by Engr-in-Charge.
M&L wiring for circuit/ sub main wiring 2x4.0 Sqmm+1x4.0 Sqmm earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable on surface as required including in PVC cassing capping of suitable size complete all as specified and directed by Engineer-In-Charge.
M&L for earthing in repair and earthing complete with GI earth plate electrode 600x600x6 mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to GI strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & PCC cover of size (300mmx300mm) all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.Note:-(a).Earth resitance should be less than 5 Ohm up to Warranty period one year. (b).In case earth resitances not found satisfactorily contractor will redo the same earthing.
Supply, installing, commissioning and testing static Silent Diesel Engine driven generating set capable of delivering mimimum 75 KVA or next higher rating available in the market, 415 volts AC 3 Phase, 4 wire system of supply), 50 HZ at power factor 0.8 minimum, as per IS: 10001/10002 and alternator as per IS:13364 complete with relay panel for automatic starting on mains failure, control panel (AMF) having meters, sound proof canopy and The DG set shall consist of a diesel engine coupled directly to a matching alternator and mounted on Anti vibration pads of approved make on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardized by manufacturer, complete all as specified and directed and shall comprise of the following:-
(a) Engine (prime mover) : Directly coupled Diesel engine water cooled suitably de-rated of matching BHP for driving mimimum 75 KVA or next higher rating available in the market, capacity alternator electric start, four stroke confirming to latest IS 10001/10002 Part-II 19801 for continuous running and capable for taking 10% over load for 1 hour complete with following accessories :- (i) Fly wheel to suit flexible coupling (ii) Flexible coupling with guards (iii) Air cleaner with filters (iv) Lubricating oil filter (v) Anti-vibration pad as recommended by manufacturer’s (vi) Electronic governor of suitable capacity (vii) Self-starter 12 volts DC.
(viii) Necessary arrangement for charging battery (ix) Lead acid storage or dry type battery as recommended by manufacturer along with flexible copper battery lead and connector (x) Battery rack made out of MS angle ingle frame as recommended by manufacturer’s xi) standard safety device as recommended by manufacturer’s (xii) daily service fuel tank for full running capacity of DG set for min 08 hours enclosed within the canopy all as per CPCB with lever indicator inlet, fuel outlet drain pug, air vent and locking arrangement’s etc. (xiii) Exhaust system shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BS-4735 to prevent excess heat radiation on the engine and stage for operator.
(xiv) Engine display should have following:- (a) KW, KVA, KWH, KVAR, Power Factor, Phase to Phase & Phase to Neutral Voltage, Ampere etc., (aa) Lubrication oil temperature (ab) Lubrication oil pressure (ac) water temperature (ad) Battery voltage(af) Indicator lamp etc (ag) Safety measure :- (i) Low lubricant oil pressure trip (ii) High coolant temperature trip (iii) Engine over speed trip iv) Battery charging alternator (v) Emergency stop pressed.
(b) Alternator : mimimum 75 KVA or next higher rating available in the market, at 0.8 power factor, self-regulated 3 phase with neutral 415 Volts 50 Hz 1500 RPM as per IS 2613 / IS : 4722 complete with automatic voltage regulator and foot mounted regulator and foot mounted including making cable connection. The salient feature of alternator are as under:- (i) Voltage regulation under static condition + 1.5% (ii) Class 'H' insulation (iii) Permanently lubricating bearing (iv) Capable to make 10% over load for one hour for every 12 hours (c) AMF Panel in built suitable for DG set (d) Acoustic Enclosure : Floor mounted acoustic enclosure suitable for 75 KVA DG set as per CPCB norms of the make as that of DG set be provided.
Note1: DG set shall be composite type with AMF panel prime mover and alternator and allied accessories in one enclosure including PCC foundation as per OEM Make: Kirloskar /Cummins/ Greaves cotton Note2:Fuel for testing including all testing arrangements as per norms is deemed to be included in quoted rate.
Supply, installation, testing and commissioning of static voltage stabilizer75 KVA for automatic IGBT controlled (unbalanced load), microprocessor based digital 3 phase, 4 wire, Air cooled, Indoor type and designed for input variation between 360V to 468V with output voltage stabilized at 415V with accuracy ± 1% (P-P) complete all as specified and directed by Engr-in-Charge with following:- (1) Type – IGBT static voltage stabilizer indoor (2) Rated Freq 50HZ (3) Wave form distortion: Nil (4) Response time not to exceed 10 milliseconds (5) Duty cycle: Continuous 100% loading at lowest input voltage for indefinite time (6) Rate of correction: greater than 3000volts/sec, the said voltage regulator should sense as well as correct any voltage sag/fluctuation within 20 milliseconds, i.e. one wave form. (7) Overload capacity: 125%, it should be take startup load with high in rush currents. (8) Efficiency: greater than 96% at 100% and highest voltage input. (9) Type of load- Three phase unbalanced type. (10) Digital display voltmeter/Ampmeter. (11) Cooling type: Air cooled (12) Protections:- (i) MCCB/MCB for overload and short circuit protection (ii) Intelligent bypass and manual bypass arrangement (13) Voltage regulations shall be performed by IGBT driven PWM invertor operating at around 20KHZ switching frequency with typical voltage correction time of 20MS (one cycle for 50HZ supply) so that output voltage complies with the requirements of ITIC curve for regulated voltage supply to electronic machinery. (14) Voltage regulation should be achieved by superimposition of PWM wave on incoming wave, without and break in the power path. (16) Warranty 2 years Make: Vintek Electronics (Volina)/Automatic Electric(AE)/V Guard.
Supply and fixing for indoor panel Floor Mounted cubical, self supported, front & rear openable, double door ,hinged type with locking arrangement & sloping top canopy ,suitable ventilation on both side, with wire mesh,IP52 protection with Dust & Vermin proof etc. fabricated out of 2 mmC RCA sheet duly powder coated , mounted/fixed on MS Angle iron stand /frame 40cm height from FFL. Fabricated out of 50*50*6 mm thick MS Angle duly painted with black enamel synthetic paint over coat of red oxide zink chrome primer, duly grouted in PCC 1:3:6 Type C1 using foundation etc, complete all as directed, Main LT panel working on 440V 3-phase, 50 Hz, AC supply . including the following accessories . Incomer MCCB 1. MCCB 250 A with adjustable Thermal & magnatic protection 4 pole, 36KA - 01 No, Outgoing feeders 1. MCCB TP 200 Amp,25 KA with adjustable thermal & maganetc protection ( 80- 100 ) -01 Nos 2. MCCB TP 160 Amp,25 KA with adjustable thermal & maganetc protection ( 80- 100 ) -02 Nos 3. One Blank Chamber for future use 4. Digital Multifunction Meter for measure Voltage/Amp/Hz etc -01 no 5. Indicator Lamp neon type (RYB) -01 no
M&L for earthing in repair and earthing complete with copper earth plate electrode 600x600x3.15 mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to Copper strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & PCC cover of size (300mmx300mm) all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.Note:-(a).Earth resitance should be less than 5 Ohm up to Warranty period one year. (b).In case earth resitances not found satisfactorily contractor will redo the same earthing.
Supply, installation, commissioning and testing of storage type electric water heater of capacity 25 Ltrs, AC ,240 Volt, 50 Hz, 5 star rating vertical/ Horizental type duly fixed to existingposition where directed including suitable mounting bolts, nuts and washer duly grouted including necessary accessories such as saftey valve, thermostste, NRV, inlet / out water connection piece etc incl writing MES No, on Geyser with white synthetic enamelled paint , all as specified and as directed by Engr-in-Charge. Make - Cromption- ARNO NEO , Havells /Usha
S&F Exhaust fan 300 mm sweep ( Metallic type ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers including making suitable size hole in the existing wall, plastering, white washing or colour washing to the disturbed surface of wall complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector including writing MES No. on Exhaust fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Havells Ventil Air DB NEO or equivalent in crompton / usha
S&F Exhaust fan 225 mm sweep ( Metallic type ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers including making suitable size hole in the existing wall, plastering, white washing or colour washing to the disturbed surface of wall complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector including writing MES No. on Exhaust fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Havells Ventil Air DB NEO or equivalent in crompton / usha
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run on wall/floor in PVC cassing capping not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one geyser point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - the point wiring for geyser shall be independent from main DB of indls qtr to geyser power socket. The quoted rate deemed to be included in this item.
Supplying and fixing Modular switch , one way, 16 amps, one Module of Make:- Ancher Roma/Legrand/ Crabetree.
Supplying and fixing Modular socket 16 amps-6 pin multipin, 2 Module of Make:- Ancher Roma/Legrand/ Crabetree.
Supply and fix 15mm dia bore galvanized iron tubing, medium grade including cutting of existing pipe , making joint connection etc as reqd at site with all fitting as tee,socket joints etc fixed to Wall with Iron clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
Supply and fix 15mm dia bore plug type bib taps C P brass , screwed for iron pipe and fixed.etc all as specified and directed.Make- Jileto, Seiko etc
Supply and fix 15mm dia bore stop/angle valve , C P Brass, screwed for iron pipe and fixed.etc all as specified and directed.Make- Make- Jileto, Seiko etc
E M CONSTROL SYSTEM
SHRI SULAI ELECTRICALS
NARMARAJ ELECTRICALS
K R Electricals
MAHIMA CONSTRUCTION
metro electrical services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .